Airbus A319-131
Service difficulty reports · 5,795
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319131' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319131' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014123092870Oxygen Mask · unwanted deployO2 MASKS DROPPED ROW 32ABC. INSPECTED PAX O2 PANEL IAW MT 35-003, NO DAMAGE NOTED. REPACKED O2 COMPARTMENT & SECURED PANEL DOOR. MANUAL MASK RELEASE OPERATIONAL CHECK IAW AMM 35-23-00- 710-001 WITHIN 3 DAYS.SDR CALA2014122392863Oxygen Mask · unwanted deployO2 MASKS DROPPED ROW 32ABC. INSPECTED PAX O2 PANEL IAW MT 35-003, NO DAMAGE NOTED. REPACKED O2 COMPARTMENT & SECURED PANEL DOOR. MANUAL MASK RELEASE OPERATIONAL CHECK IAW AMM 35-23-00- 710-001 WITHIN 3 DAYS.SDR CALA2014122392862Slide · defectiveEPSU EXT LOAD FWD LIGHT MSG APPEARS ON PTP PANEL AFTER EMER LIGHT TEST. REPLACED DOOR 1L SLIDE IAW AMM 25-62-44-400-006A. EMER LIGHT TESTED GOOD, NO MSGS.SDR CALA2014122692867O-Ring · blownSYSTEM Y HYD QTY LOST IN FLIGHT. RESERVOIR QTY DROPPED WITH NO SYS PRESS. DIVERTED & FOUND PTU O RINGS BLOWN OUT. REPLACED CHECK VLV ASSEMBLY & O RINGS FOR PTU. OPERATIONS CHECKED & LEAK GOOD. SERVICED SYS TO NORMAL.SDR CALA2014122392861Hydraulic Line · leakingHYD Y ENG 2 PUMP LOW PRESS ECAM & YELLOW HYD LOW PRESS ECAM WARNINGS. OBSERVED YELLOW HYD QTY LOW. FOLLOWED QRH, SELECTED NR 2 ENG HYD PUMP OFF, PRESS & QTY STABILIZED. PERFORMED ENG RUNS, NO FAULTS ON ECAM FOUND HYD LINE IN RIGHT WW LEAKING. REPLACED LINESDR CALA2014122392860Battery · failedEMERGENCY BATTERY PACKS 11WL & 12WL FAIL TEST. REPLACED EPSU BATTERIES IAW AMM 33-51-38-400-002-A.SDR CALA2014122392857Fan · faultyFLIGHT ATTENDANT`S REPORTED SMOKE & BURNING SMELL. ACCOMPLISHED AMM TASK 05- 51-10-S00-801C1. DETERMINED THAT NR 2 CABIN RECIRC FAN 14HG IS AT FAULT IAW SEQ 1032003 FOR PART CHANGE.SDR CALA2014122392851Skin · damagedLEFT WING FUEL TANK ACCESS PANEL 540K B HAS 3 EACH ELONGATED HOLES AT 4:00, 7:00 &11:00 POSITIONS. REWORKED & REPAIRED LANDING IAW ECRA 5720-02626. ACCOMPLISH INITIAL REQUIREMENTS IAW PART 2 OF ECRA BEFORE ACFT REACHES 85800T OR 4290 0C WHICHEVER COMES FIRSTSDR CALA2014122392850Skin · damagedRIGHT ELEVATOR UPPER SURFACE HAS A TRAPPED WATER INDICATION. 113 INCHES FROM INBD, 12 INCHES FROM TE & 6 INCHES IN DIAMETER & THE LOWER SURFACE 80 INCHES FROM INBD, 5 INCHES FROM TE & 2 INCHES IN DIAMETER. CUT OUT TRAPPED WATER & APPLIED REPAIR CONFIG 1 & RESDR CALA2014122392846Door Frame · corrodedAFT FUSE R2 DOOR CUT OUT FRAME 68 AT STRINGER 23R FRAME HAS CORROSION. CUT OUT DAMAGE & INSTALLED REPAIR IAW SRM 53-41-12 FIG 202. CATEGORY B REPAIR SRI 53-41-12-2-002-00 REQUIRES FIRST INSPECTION AT 64000C AFTER ACFT DELIVERY. CURRENT 22528C, FIRST INSPECTSDR CALA2014122392845Shear Plate · corrodedRIGHT AFT SHEAR PLATE HAS CORROSION. REMOVED & INSTALLED NEW SHEAR PLATE & FRAME SUPPORT IAW SRM 51-42-11 PG 7, 23, 24 & 30 - 32 & 46 - 48.SDR CALA2014122392844Door Sill · corrodedR2 DOOR SILL HAS CORROSION FRAME 66 - 68. R & R NEW DOOR SILL IAW SRM 51-42-11 PARA 5, 6, & 8.SDR CALA2014122392843Skin Panel · damagedLEFT ELEVATOR UPPER SKIN PANEL HAS TRAPPED WATER INDICATIONS IN 5 LOCATIONS. 1. 73 INCHES FROM INBD, 8 INCHES FROM TE & 3 INCHES IN DIAMETER. 2. 101 INCHES FROM INBD, 5 INCHES FROM TE & 5 INCHES IN DIAMETER. 3. 204 INCHES FROM INBD, 5.5 INCHES FROM TE & SDR CALA2014120992799Door Sill · corrodedL2 DOOR SILL HAS CORROSION AT FRAME 68. INSTALLED REPAIR IAW SRM 53-41-14 FIG 201 SHEET 3 PRINCIPLE 4.SDR CALA2014120992813Light · inoperativeEMERGENCY LIGHTS FAIL MSG FOUND DURING 2 SVC CHECK. MSG READS, EPSU EXT LOAD RT. REPLACED EPSU & BATTERY FOR 12WL, NO HELP. REPLACED ALL FOUR LAMPS AT LIGHTS 60WL & 62WL. OPERATIONS CHECKED GOOD IAW AMM 33-51-15-400-0.SDR CALA2014120292758Unknown · odorDURING FLIGHT, ACFT HAS A SMELL SIMILAR TO PLASTIC MELTING IN OVEN. SEEMS TO WORSEN WITH POWER INCREASE. PERFORMED NR 2 ENG WASH. REPLACED LT & RT RECIRCULATION FILTERS. PERFORMED HIGH POWER ENG RUN TO BURN OUT SMELL IAW JRH-2-40-35. NO ODOR AT THIS TIME.SDR CALA2014120292754Battery · dischargedEMERGENCY LIGHT TEST FAILED ON 2 SVC. REPLACED FWD BATTERY. OPERATIONS CHECKED GOOD IAW MM 33-51-00.SDR CALA2014111492700Connector · not seatedEMERGENCY LIGHT TEST FAILED IAW NR 2 SVC. EPSU BATTERY EMER LT. RESEATED CONNECTOR ON LT MID EMER POWER SUPPLY IAW AMM 33-51-11 TEST PASSED.SDR CALA2014111092675Contact · dirtyEMERGENCY LIGHT TEST FAILED ON 2 SVC. REMOVED & CLEANED BATTERY CONTACTS IAW MM 33-51-00. OPERATIONS CHECKED GOOD.SDR CALA2014102992625Chiller · malfunctionedREPORT OF EXHAUST SMELL NEAR FWD AFT LAVATORY, AFT GALLEY AREA. FOUND AFT GALLEY FWD CHILLER BLUE POWER LIGHT FLASHING, WITH LITTLE OR NO AIRFLOW FROM CHILLER. UNIT SHUTS OFF & RESTARTS. REPLACED AFT GALLEY FWD CHILLER, CLEANED FILTER. NO SMELL AFTER REPLASDR CALA2014102992624Mount · corrodedRIGHT PYLON ENG MOUNT HAS SURFACE CORROSION. PERFORMED ECRA 5450-02273 NO DEFAULTS FOUND. OK TO CONTINUE.SDR CALA2014102392556Fairing · looseAIRFRAME VIBRATION ONCE AIRBORNE, EMER DECLARED, RETURNED. SECURED & APPLIED TAPE TO FILLET FAIRING ON LT SIDE OF FUSELAGE. COMPLETED INSPECTION OF FUSELAGE, NO DEFECTS FOUND.SDR CALA2014121692830Oxygen Bottle · unserviceableAFT CABIN LT SIDE BEHIND LAST ROW OF SEATS HAVE BOTH PORTABLE O2 BOTTLE CANNULA TIGHTLY TIE WRAPPED TO BOTTLES RENDERING BOTTLES USELESS. REMOVED TIE WRAPS FROM BOTH BOTTLES & REPLACED UPPER BOTTLE.SDR CALA2014101692456Battery · dischargedEMERGENCY LIGHT OPERATIONAL TEST FAILED. EPSU BATTERY AFT LT DISPLAYED AFTER TEST. RESET AFT LT EPSU BATTERY. TESTED GOOD.SDR CALA2014101692434Slide · defectiveEMERGENCY LIGHTS TEST FAILS WITH MSG EPSU EXT LOAD FWD L. R & R DOOR 1R ESCAPE SLIDE PACK IAW AMM 25-62-44. EMER LIGHTS TESTED OK.SDR CALA2014101392396Flap · dentedDENT IN RT INBD FLAP NEAR FUSELAGE. DAMAGE WITHIN ALLOWABLE LIMITS IAW SRM 57-52-00 PAR 8. AREA FREE FROM CRACKS IAW NDT IAW NT M51-10-08.SDR CALA2014101392394Slat · dentedNUMBER 2 LT SLAT HAS DENT AT INBD END THAT IS OUT OF LIMITS. DAMAGE REMOVED & DOUBLER REPAIR INSTALLED IAW SRM 57-40-00. HFEC IAW NTM 51-10-08 PB6.SDR CALA2014100792375Door Sill · corrodedR2 DOOR SILL HAS CORROSION, AFT SIDE FRAME 68 STRINGER 23R. AFTER BLENDING FOUND BEYOND SRM ALLOWABLE LIMITS. R & R FILLER IAW SRM 51-41-14 FIG 201 PARA 5 A PRINCIPLE 5.SDR CALA2014100792374Door Sill · corrodedR2 DOOR SILL HAS CORROSION AT NUTPLATE HOLES AT AFT INBD END. REMOVED CORROSION & FOUND BEYOND SRM ALLOWABLE LIMITS. REPAIR AT R2 DOOR SILL IAW SRM 53-41-14 FIG 201 SHEET 3, REPAIR PRINCIPLE 4.SDR CALA2014100792367Battery · not seatedEMERGENCY LIGHT TEST FAILED ON 2 SVC. RESEATED EPSU BATTERY IN AFT CABIN IAW AMM 33-51-38. EMER LIGHT TEST PASSED.SDR CALA2014092992321Actuator · failedNR 1 ENGINE EGT OVERLIMIT DURING TAKEOFF. FAULTED 2.5 BLEED ACTUATOR. EXCEEDANCE RECORDED WAS 640 FOR 8 SECONDS. REPLACED 2.5 BLEED ACTUATOR IAW AMM 75-31-42-400-010-B13SDR CALA2014091892245Skin · saturatedLEFT ELEVATOR UPPER SURFACE HAS WATER INGRESS AT THREE EACH LOCATIONS IN ZONE 3. REMOVED DAMAGE & REPAIRED IAW SRM 55-21-11 PARA 5 E FIG 205. REPAIR REQUIRES SRI INSPECTIONS IAW SRI 55-21-11-2-002-00 PARA 3 - B TABLE 203. FIRST INSPECTION DUE AT 48000FC & 6SDR CALA2014091892235Attach Fitting · corrodedFORWARD CARGO BILGE BELLY FAIRING ATTACH HAS CORROSION AROUND RIVETS ON SKIN FRAME 30 - 31 STRINGER 42L. CORROSION REMOVED IAW SRM 53-21-11DIAGRAM 105 PARA 4 E.SDR CALA2014091892234Door Sill · corrodedL2 DOOR SILL CORRODED BETWEEN STRINGER 22L & 23L AT FRAME 68. BLENDED CORROSION AT FRAME 68 ON L2 DOOR SILL BEAM IAW SRM 51-41-14 FIG 101. AFTER REMOVAL FOUND OUT OF LIMITS IAW SRM. R & R L2 DOOR SILL BEAM IAW SRM 51-72--11 PG 6 D & SRM 51-42-11 PARA 6 & 7.SDR CALA2014091292110Battery · dischargedRIGHT EMER BATTERY MSG ON PTT PANEL DURING EMER SYS LIGHT TEST. REPLACED EMER BATTERY, RESET CIDS & LIGHT TESTED OK.SDR CALA2014091292107Door Sill · corrodedR2 DOOR SILL HAS CORROSION FRAME 66 - 68 STRINGER 22R - 23R. DOOR SILL REPLACED IAW SRM 51- 42-11.SDR CALA2014090992094Battery · not seatedEMERGENCY LIGHT TEST FAILED ON 2 SVC. RESEATED EPSU BATTERY AT AFT LT IAW AMM 33-51-38, EMER LIGHT TEST NOW PASSES.SDR CALA2014090392053Epsu · faultyEMERGENCY LIGHTS TEST FAILS NO GREEN LIGHT & MSG EPSU UNIT FWD L. REPLACED EPSU & BATTERY IAW MM 33-51-38. SYS BITE TESTS GOOD & EMER LIGHT TEST PASSED.SDR CALA2014090392052Epsu · malfunctionedEMERGENCY LIGHTS TEST FAILS NO GREEN LIGHT & MSG EPSU BATTERY EMER R. RESET EPSU & SYS BITE CHECKED GOOD IAW MM 33-51-38 & EMER LIGHT TEST PASSED.SDR CALA2014090392050Battery · dischargedDURING SERVICE CHECK OF EMER LIGHTS FOUND EPSU FWD L DISPLAYED ON FWD FLIGHT ATTENDANT PANEL. REPLACED THE EPSU & BATTERY ON 10WL IAW MM 33-51-38-401.SDR CALA2014082692029Door Sill · corrodedL1 DOOR SILL BEAM WAS CORRODED AROUND THE FWD GIRT BAR FITTING AFT INBD ATTACH HOLE & THE AFT FITTING AFT INBD & OTBD ATTACH HOLES. HOLES WERE SPOT FACED & REPAIR WASHERS INSTALLED IAW SRM 53-11-14 PARA 4 E FIG 108. MINIMUM MATERIAL THICKNESS AT SPOT FACES ISDR CALA2014082692028Door Sill · corrodedR1 DOOR SILL BEAM WAS CORRODED AROUND THE FWD & AFT GIRT BAR FITTING HOLES & AROUND THE FWD DRAIN HOLE. CORROSION WAS REMOVED & AREA BLENDED AROUND THE DRAIN HOLE. FWD GIRT BAR FITTING AFT OTBD HOLE & ALL 4 HOLES AT THE AFT GIRT BAR FITTING WERE SPOT FACED & SDR CALA2014082692025Door Sill · corroded2R DOOR SILL CORRODED UNDER THE GIRT BAR PLATES. DOOR SILL REPLACED IAW SRM 51-42-11 & SRM 51-44-11.SDR CALA2014082592014Door Sill · corrodedR2 DOOR SILL & AFT CORNER FITTING CORRODED BETWEEN FRAME 66 & 68. DOOR SILL & AFT CORNER FITTING R & R IAW SRM 51-42-11.SDR CALA2014082192005Epsu · inoperativeNUMEROUS EMER ESCAPE PATH LIGHTS INOPERATIVE THROUGHOUT CABIN DURING HMV TEST. R & R EPSU 10WL IAW AMM 33-5 1-38-000-001-A & 33-51-38-400-001-A. R & R BATTERY PACK 13WL IAW AMM 33-51-38-000-002-A & 33-51-38-400-002-A, EEPL LIGHTS OPERATIONS CHECKED GOOD IAW SDR CALA2014082192002Skin · dentedDENT REPORTED BY FLIGHT CREW & CATERING AFT OF DOOR 2L. FUSELAGE DENTED BETWEEN FRAME 69 & 70 AT STRINGER 21. DENT ABOVE STRINGER IS .040 INCHES DEEP, .23 INCHES FROM NEAREST RIVET ROW, 2.66 INCHES X 1.24 TOTAL AREA. DENT BELOW STRINGER IS 3 X 1.25, .010 ISDR CALA2014081891999Battery · dischargedFAILED EMER LIGHT TEST FWD FLIGHT ATTENDANT PANEL. EPSU BATTERY EMER LIGHT REPLACED BOTH LT & AFT LT BATTERIES AMM 33-51. TEST NOW OK.SDR CALA2014081891997Door Sill · corrodedL2 DOOR SILL HAS SPOTS OF CORROSION BETWEEN FRAME 66 & 68. BLENDED CORROSION, AFTER BLENDING ALL AREAS WERE WITHIN LIMITS EXCEPT FOR NUTPLATE AT INBD FLANGE ON FRAME 68 IAW SRM 53-41-14 FIG 101.SDR CALA2014081891995Stringer · corrodedCORROSION FOUND ON STRINGER 42R AT FRAME 60 IN AFT PIT. UPON FURTHER EVALUATION FOUND STRINGER 42R CORRODED BEYOND LIMITS. REMOVED CORRODED SECTION OF STRINGER & SPLICED IN NEW SECTION OF STRINGER BETWEEN FRAME 59.5 & 60.5 IAW SRM 53-00-13 FIG 201.SDR CALA2014081391982Door Sill · corrodedL2 DOOR SILL FWD & AFT HAS CORROSION FRAME 68 - 68, STRINGER 22L - 23L. FABRICATED & INSTALLED REPAIR IAW SRM 53-41-14 REPAIR PRINCIPLE 5 FIG 201 SHEET 3 AREA K.
Back to Airbus A319-131