Airbus A319-131
Service difficulty reports · 5,795
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319131' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A319131' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014081391976Door Sill · corrodedR2 DOOR SILL WAS FOUND CORRODED. SILL REPLACED IAW SRM 51-42-11.SDR CALA2014081391975Stringer · corrodedAFT PIT STRINGER 31R CORRODED BETWEEN FRAME 65 & 66. STRINGER SECTION WAS REPLACED FROM FRAME 65 - 69 IAW SRM 53-00-13.SDR CALA2014081391956Plate · damagedFOUND BURN MARK ON LOWER RT CORNER OF STATIC PORT AREA. STBY LT STATIC PORT. DISCONNECTED STBY STATIC PORT & REMOVED FROM INSIDE SURFACE. REMOVED STATIC PORT BLANKING PLATE IAW AMM 53-19-42. INSTALLED IAW AMM 53-19-42-400-001-A TO STEP 3F 7. VERIFIED ZONSDR CALA2014081391970Skin · corrodedLEFT WING LOWER FUEL TANK LANDING 540HB HOLE AE & 540KB HOLE H WERE FOUND CORRODED. HOLES WERE REAMED TO 0.391 & 0.406 & REPAIRED IAW ECRA 5721-01374.SDR CALA2014081391969Skin · corrodedLEFT WING LOWER FUEL TANK LANDING 540HB HOLE B & 540KB HOLE D WERE FOUND CORRODED. HOLES WERE REAMED TO 0.363 & REPAIRED IAW SRM 57-21-11 PARA 5 B FIG 202.7.SDR CALA2014081391968Skin · corrodedLEFT WING LOWER FUEL TANK LANDING 540HB HOLE AE & 540KB HOLE H WERE FOUND CORRODED. HOLES WERE REAMED TO 0.391 & 0.406 & REPAIRED IAW ECRA 5721-01374.SDR CALA2014081391967Skin · corrodedLEFT WING LOWER FUEL TANK LANDING 540HB HOLE B & 540KB HOLE D WERE FOUND CORRODED. HOLES WERE REAMED TO 0.363 & REPAIRED IAW SRM 57-21-11 PARA 5 B FIG 202.SDR CALA2014081391964Fitting · corrodedLEFT MLG UPPER SIDE STAY BUSHING SHOWS EVIDENCE OF ROTATION. SEALANT IS SPLIT. CORROSION FOUND. REMOVED CORROSION BY OVER SIZING SIDE STAY FITTING LUG & INSTALLING HIGH INTERFERENCE FIT BUSHINGS IAW SRM 57-26-13 PARAGRAPH 5 E FIG 206. ACID ETCH & FIP IAW 5SDR CALA2014081391963Fitting · corrodedRIGHT MLG UPPER SIDE STAY BUSHING HAS EVIDENCE OF ROTATION. SEALANT FOUND SPLIT. REMOVED CORROSION BY OVER SIZING SIDE STAY FITTING LUG & INSTALLING HIGH INTERFERENCE FIT BUSHINGS IAW SRM 57-26-13 PARAGRAPH 5 E FIG 206. ACID ETCHED & FPI IAW 57-00-0PR8 & NTSDR CALA2014081191931Chiller · overheatedAFT GALLEY CHILLER OVERHEATED IAW CREW VERBAL. CB'S PULLED THE CB PANEL AT GALLEY & COFFEE MAKERS WERE HOT & DID NOT COOL DOWN. EVENTUALLY CREW DESELECTED THE COMMERCIAL SWITCH & STILL DID NOT COOL. DEFERRED IAW MEL. DEACTIVATED CHILLER, PULLED & COLLARED SDR CALA2014081191928Door Sill · corrodedR2 DOOR SILL FRAME 66 - 68 CORROSION FOUND OUT OF LIMITS. REPAIRED IAW SRM53-41-14 PARA 5A FIG 201.SDR CALA2014081391958Light · malfunctionedOVERHEAD EMER LIGHTS INOPERATIVE. OVERWING EMER EXIT LIGHTS ON CONTINUOUSLY RESET. CIDS EMER LIGHTS IN CABIN, OPERATIONS CHECKED GOOD.SDR CALA2014081191949Door Frame · corrodedDETAILED INSPECTION, ROTO OF AFT PAX CREW DOOR CUT OUT. DOOR STOP FITTINGS HOLES, AT FRAME 68 WEB, LT & RT IAW AMM 53-41-00-220-813. CORROSION DMG NOTED AT R2 POS 1, 2, 3 & 6. L2 NR 2. CLEANED & RESCANNED, NO INDICATIONS.SDR CALA2014080691736Skin · dentedEXTERNAL FUSELAGE SKIN DENTED AT THREE EACH LOCATIONS FRAME 23 & 24, STRINGER 23L & 24L. FOUND DENTS TO BE OUT OF LIMITS IAW SRM 53-11-11 FIG 115. FABRICATED REPAIR DOUBLER & INSTALLED IAW SRM 53-00-11 FIG 232 PG 505 - 506.SDR CALA2014080691738Slide · faultedEPSU EXT LOAD FWD L FAULT WHEN EMER LIGHTS TEST PERFORMED. REPLACED SLIDE ASSEMBLY DUE TO EXTERNAL LOAD FAULT DOOR 1R IAW 25-62-44.SDR CALA2014080691735Skin · dentedSMALL DENT FOUND ON ARRIVAL ON RT FUSELAGE, 1 FT ABOVE UPPER WINDOW LINE & 7 WINDOWS FT OF OVERWING EXIT. DENT WAS OUT OF LIMITS IAW SRM 53-41-11. FABRICATED REPAIR DOUBLER 7 INSTALLED IAW SRM 53-00-11.SDR CALA2014080191589Door Sill · corrodedL2 DOOR SILL HAS CORROSION AT 7 E. LOCATIONS BETWEEN FRAME 66 & 68. REPAIRED THE AREA IAW SRM 53-41-14.SDR CALA2014080191588Door Sill · corrodedR2 DOOR SILL FRAME 66 - 68 CORROSION FOUND OUT OF LIMITS. REPAIRED IAW SRM 53-41-14 PARA 5A FIG 201.SDR CALA2014080191586Skin · damagedLEFT AIRFONE ANTENNA AREA NEEDS REPAIRED AT FRAME 63 - 64 STRINGER 41 - 42LT VARIANT 002. REPAIRED IAW SRM 53-00-11 PARAGRAPH 4S FIG 230.SDR CALA2014072891547Skin · dentedFUSELAGE SKIN RT DENT FOUND OUT OF LIMITS AT FRAME 1 - 28 + WL. INSTALLED A 7 X 7 REPAIR IAW SRM 53-00-11 4S-230 PRINCIPLE 2. FIRST INSPECTION REQUIRED AT 77452 PTC. R & R IAW SRM 53-00-11-PH4S FIG 230. REINSPECT IAW SRI53-00-11-2-017-00.SDR CALA2014072891546Shear Web · corrodedRIGHT FRAME SUPPORT FOR SHEAR WEB FOUND CORRODED FRAME 69 - 70R PN 5347112320300. R & R SHEAR WEB IAW SRM 51-42-11.SDR CALA2014072591512Door Sill · corrodedMAJOR REPAIR. R2 DOOR SILL HAS CORROSION AT GIRT BAR ATTACHMENT BETWEEN FRAME 66 & 68 AT STRINGER 43. AFTER REMOVING CORROSION, MATERIAL LOSS WAS FOUND TO BE OUT OF LIMITS IAW SRM 53-41-14 FIG 101. R & R RT 2 DOOR SILL.SDR CALA2014072291496Light · inoperativeEMERGENCY LIGHTS FAILED TEST IAW NR 2 SERVICE. FOUND OVERWING EMER SLIDE LIGHT INOPERATIVE. RELAMPED IAW MM 33-51-15 EMER LIGHT TEST DID NOT PASS.SDR CALA2014072991571Sensor · faultyAT CRUISE NOSE WHEEL STEERING & BRAKE SYS 2 FAULT. IAW FLIGHT MANUAL & QRH, RESET WAS ATTEMPTED WITH THE ANTI-SKID SWITCH & MALFUNCTION RETURNED EXCEPT BRAKE SYS FAULT WAS NOW THE NR 1 SYS. R & R SENSOR 3GC IAW AMM 32-51-19. OPERATIONS CHECKED OK.SDR CALA2014071591468Control Unit · malfunctionedSYSTEM 1 FAULT DISPLAYED ON UPPER ECAM SCREEN. INFLIGHT RESET NO HELP. BSCU REPLACEMENT. SYS 1 FAULT ON ECAM WENT AWAY UPON LANDING NO HISTORY.SDR CALA2014071191441Actuator · malfunctionedCOMPRESSOR VANE DISPLAYED ON UPPER ECAM SCREEN. ENG PARAMETERS NORMAL. R & R VSV ACTUATOR IAW AMM 75-32-41. LEAK & OPERATIONS CHECK WERE GOOD OK TO CONTINUE.SDR CALA2014071191440Hydraulic System · lowFLIGHT DIVERTED DUE TO LOSS OF YELLOW HYDS. SERVICED HYDS TO FULL LEVEL.SDR CALA2014071191412Panel · damagedON ARRIVAL PANEL 192MB FOUND OPENED & DAMAGED. ALSO DAMAGED PANEL 192FB AC BAY RT. TWO PUNCTURES DIRECTLY BELOW PANEL 192MB. REPLACED PANEL 192MB.SDR CALA2014070191392Computer · malfunctionedFLIGHT CONTROL FLAP 1 FAULT. REPLACED NR 1 SFCC IAW AMM 27-51-34. TESTED OK ALSO CLEANED CONNECTOR ON FLAP PCU VLV BLOCK NR 1 & 2. OPERATIONS CHECK FLAPS RAN UP & DOWN 4 TIMES NO MSG NOTED.SDR CALA2014063091365Warning System · false indicationCREW REPORTS WHILE ATTEMPTING NR 1 ENG START RECEIVED ENG 1 START FAULT WITH EGT OVER LIMIT. CHECKED EXCEEDANCE PAGE & NO OVERTEMP OCCURRED. CHECKED INLET & EXHAUST, NO DEFECTS NOTED. APU BLEED SYS INOPERATIVE.SDR CALA2014062091307Power Supply · faultedEMERGENCY LIGHTS TEST FAULTS EPSU INT LOAD EMER RT. REPLACED EPSU POWER SUPPLY AT BELOW RT EMER EXIT DOOR 12WL.SDR CALA2014062091310Door Sill · corrodedCORROSION ON L2 DOOR SILL AT FRAME 66 - 68 IN AFT WET AREA. A 1 SECTION OF THE FLANGE WAS CUT OUT & A REPAIR INSTALLED IAW SRM 53-41-14 PARA 5 A FIG 201, REPAIR PRINCIPAL 5.SDR CALA2014062091306Slide · defectiveEMERGENCY LIGHT TEST FAILS WITH EPSU EXT LOAD FWD LT IAW TSM 33-51-00-810-808. FOUND 1R SLIDE BAD.SDR CALA2014062091309Door Sill · corrodedR2 DOOR SILL INBD FLANGE WAS FOUND CORRODED AT FRAME 68. A 1 SECTION OF THE FLANGE WAS CUT OUT & A REPAIR INSTALLED. REPAIR REQUIRES INSPECTION IAW SRI53-41-14-2-001-00 PARA 3 A TBL 202.SDR CALA2014062091308Spar · chafedNUMBER 2 PYLON LOWER SPAR FOUND CHAFED AT LOWER SPAR RIB 5. REPAIR ACCOMPLISHED. THIS IS A CAT B REPAIR & REQUIRES SUBSEQUENT INSPECTIONS.SDR CALA2014062091305Warning System · false activationCOMPRESSOR VANE DISPLAYED ON UPPER ECAM SCREEN, ENG PARAMETERS NORMAL. OCCURRED DURING CLIMB OUT WAS JUST MOMENTARY. THEN REOCCURRED DURING TAXI-IN & REMAINED DISPLAYED. WORKED WITH LOCAL MAINTENANCE & FOUND FAULT ACRONYM B25TK IN FADEC. TROUBLESHOOTING ONSDR CALA2014061791298Warning System · faultyRIGHT WING OVERWING EXIT NOT SHOWING ARMED. PLACED ON MEL, DDP COMPLIED WITH.SDR CALA2014061791297Spar · chafedNUMBER 2 PYLON SHOWS SIGNS OF CHAFING AT FIREWALL SEAL LOWER SPAR RIB 5. ACCOMPLISHED REPAIR TO NR 5 RIB SPAR ON NR 2 PYLON IAW SRM54-51-12 FIG 202. SRI INSPECTIONS WILL BE ACCOMPLISHED AS REQUIRED.SDR CALA2014061691278Wire · damagedFORWARD CABIN EWIS RED & BLACK WIRES DAMAGED AT SEAT TRACK ROW 12 LT. REPAIRED RED & BLACK EMER LIGHT WIRES DAMAGED AT SEAT ROW 12 LT IAW ESPM 20- 53-21. INSULATION WAS DAMAGED ON WIRES FROM CONNECTOR 7260VC5-A 3330-0872-1673-18N & 3330-08702-1673-18.SDR CALA2014061691281Slat · lockedFLIGHT CONTROL SLATS LOCKED. WING TIP BREAKER ON SLAT SYS 2 FAULT CYCLED CB & PERFORMED BITE CHECK. NO FAULTS FOUND, NO MSGS. OPERATIONS CHECKED WITH CREW PRESENT. OPERATIONS CHECKED GOOD IAW AMM 27-51-00.SDR CALA2014061691284Mmr · faultedGPWS GLIDESLOPE DEVIATION, MODE 5, HAS BEEN DEFERRED IAW MEL CARD 34335. TROUBLE SHOT IAW TSM34-48- 00-810-815-A. ACCOMPLISHED OPERATIONAL TEST OF THE ENHANCED GPWS GND SELF-TEST FUNCTION, OPERATIONS CHECKED GOOD. NO FAULTS DURING EPGWS FAULT REVIEW, NR 1 MSDR CALA2014061391256Hydraulic Line · chafedFOUND HYD LEAK COMING FROM RT LG UPPER FWD BEHIND BEAM FOUND YELLOW SYS PRESS LINE LEAKING CHAFED ON SUCTION LINE IAW IPC 29-13-05-04C ITEM 23 & 24. ALL LINE CLAMPS REMOVED STOWED IN PART BAGS AT POSITIONS REMOVED YELLOW SYS HEAD PRESS REMOVED. INSTALLED & SSDR CALA2014061391268Anti-Ice System · failedFLIGHT HAD WINDOW HEAT FAIL EN-ROUTE.SDR CALA2014060991240Stringer · corrodedSTRINGER 44 BETWEEN FRAME 64 - 65 HAS CORROSION. REMOVED CORROSION & INSTALLED REPAIR ANGLE IAW SRM 53-00-13 FIGURE 202 SHEET 2. NO SRI REQUIRED.SDR CALA2014060991230Stringer · corrodedSTRINGER 33R BETWEEN FRAME 59 & 60 HAS LIGHT CORROSION. REMOVED CORROSION IAW SRM 51-73-11. THICKNESS OF THE FLANGE IS 0.063. LOW READING AFTER BLENDING IS 0.037. MAX LOSS ALLOWED IS 0.0315, 0.5 X TC. WITHIN LIMITS IAW SRM 53-00- 13 FIG 202 SH 4 PG 231. SDR CALA2014060991229Angle · crackedNR 2 PYLON HAS A CRACKED ANGLE OTBD SIDE NEAR RIB 6. CUT OUT CRACKED SPAR OTBD SIDE NEAR RIB 6 IAW SRM 54-52-12 FIG 211 SH 2. FABRICATED REPAIR SPLICE & INSTALLED SPLICE REPAIR IAW SRM 54-52-12. THIS REPAIR DOES NOT REQUIRE SRI INSPECTIONS IAW ABOVE SRM.SDR CALA2014060591212Sensor · faultyUNABLE TO RETRACT LG AFTER TAKEOFF. INSTALLED RT MLG EXTEND SENSOR 20GA IAW MM 32-31-73-400-001-A. FIRST SENSOR FROM STOCK WAS NO HELP. TRIED SECOND SENSOR & ALL WAS GOOD. SHOOK OUT WIRING FROM 20GA TO THE JUNCTION BOX ON TOP OF THE GEAR. RAN ENGS FOR 5 MSDR CALA2014060591210Circuit Board · burnedAT CRUISE 38000' FLIGHT ATTENDANT`S ADVISED OF BURNING SMELL IN THE AFT CABIN. AFTER INVESTIGATING FOUND BURNING, RUBBER SMELL BETWEEN FWD LAVATORY & LAST TWO ROWS OF SEATS. WORK TSM 24-00-00-810-823-A & 05-50-00-810-831-A. FOUND OVEN TRAY WITH BURNED FOOD SDR CALA2014060291184Stringer · corrodedAFT PIT HAS CORROSION LOCATED AT FRAME 61 - 64 STRINGER 41. R & R STRINGER LOCATED AT FRAME 61 - 64 STRINGER 41R PN D53476433200 IAW SRM 51-72-11. NO FURTHER ACTION REQUIRED.SDR CALA2014060291183Door Sill · corrodedAFT CABIN R2 DOOR SILL HAS CORROSION FRAME 66 - 68, STRINGER 23R - 23R. R & R R2 DOOR SILL PN 5348004320701 & PN D5348004220701 IAW SRM 51-72-11. NO ADDITIONAL ACTIONS REQUIRED.
Back to Airbus A319-131