Airbus A320-211
Service difficulty reports · 5,271
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320211' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320211' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2021010800131Psu · no testDURING TEST PSU OXY PANEL 26DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OK FOR SERVICE.SDR DALA2021010800130Psu · no testDURING TEST FOUND PSU PANEL 24ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OK FOR SERVICE.SDR DALA2021010600071Oxygen Mask · no testDURING TEST PSU OXY PANEL AT 27 DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OPERATIONS CHECK OK.SDR DALA2021010600070Oxygen Mask · no testDURING TEST PSU OXY PANEL AT 26 ABC DID NOT OPEN, REPACKED PSU. OK FOR SERVICE.SDR DALA2021010600069Oxygen Mask · no testDURING TEST PSU OXY PANEL AT 24 ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OK FOR SERVICE.SDR DALA2021010500045Probe · malfunctionedDURING DESCENT, ABOUT FL300, LEFT FUEL QUANTITY WAS ABOUT 1,000 LBS LOW, GOT LEFT FUEL QTY LOW ECAM. THE LEFT TANK WAS LOW AND WAS SLOW TO TRANSFER FROM OUTER TANK TO INNER TANK. REQUESTED PRIORITY HANDLING BY ATC. CORRECTIVE ACTION: NEEDS PROBE MFG P/N 021SDR DALA2020122904334Pin · out of positionDOOR PIN 1L NOT STOPPING ARMING LEVER FROM GOING DOWN. CORRECTIVE ACTION: RESEAT PIN AT 1L. OPERATIONS CHECK GOOD AT THIS TIME. OK FOR SERVICE.SDR DALA2020122904333Bottle · low pressure1L DOOR ASSIST BOTTLE LOW. CORRECTIVE ACTION: SERVICED PER A320 AMM 52-10-00. SAFETY PIN REMOVED RII. REQUIRED RII INSPECTION ITEM COMPLETED.SDR DALA2020122404255Oxygen Box · no testDURING TEST FOUND PSU OXY PANEL 32ABC WOULD NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OPERATIONS CHECK GOOD.SDR DALA2020122404254Oxygen Box · no testDURING TEST PSU OXY PANEL FOR SEAT 23 DEF WOULD NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OPERATIONS CHECK GOOD.SDR DALA2020122404253Oxygen Box · no testDURING TEST PSU OXY PANEL 28ABC WOULD NOT OPEN. CORRECTIVE ACTION: REPACKED PSU. OPERATIONS CHECK GOOD.SDR DALA2020122104167Psu · no testMULTIPLE PSU'S FAIL DROP, PER WC 2527-01041-02. CORRECTIVE ACTION: RESET AND REPACKED PSU'S THAT DID NOT FALL, OPERAITONS CHECK GOOD.SDR DALA2020122104166Psu · no testDURING TEST FOUND PSU DID NOT OPEN AT SEAT 32ABC. CORRECTIVE ACTION: REPACK PSU OPERATIONS CHECK GOOD.SDR DALA2020122104165Psu · no testFOUND SEAT 30 DEF PSU OXYGEN PANEL DID NOT OPEN DURING TEST. CORRECTIVE ACTION: REPACKED PSU, OPERATIONS CHECK GOOD.SDR DALA2020122104164Psu · no testDURING TEST FOUND PSU DID NOT OPEN AT SEAT 29DEF. CORRECTIVE ACTION: REPACK PSU OPERATIONS CHECK GOOD.SDR DALA2020122104163Psu · no testDURING TEST PSU OXYGEN PANEL SEAT 25DEF DID NOT OPEN. CORRECTIVE ACTION: REPACK PSU, OPERATIONS CHECK GOOD.SDR DALA2020122104162Psu · no testDURING TEST FOUND PSU AT SEAT 24DEF DID NOT OPEN. CORRECTIVE ACTION: REPACK PSU OPERATIONS CHECK GOOD.SDR DALA2020122104161Psu · no testDURING TEST FOUND PSU AT SEAT 23DEF DID NOT OPEN. CORRECTIVE ACTION: REPACK PSU OPERATIONS CHECK GOOD.SDR DALA2020122104160Psu · no testDURING TEST FOUND PSU AT SEAT 20DEF DID NOT OPEN. CORRECTIVE ACTION: REPACK PSU OPERATIONS CHECK GOOD.SDR DALA2020122104159Psu · no testDURING TEST FOUND PSU DID NOT OPEN AT SEAT 14DEF. CORRECTIVE ACTION: REPACK PSU OPERATIONS CHECK GOOD.SDR DALA2020122104158Psu · no testDURING TEST FOUND PSU DID NOT OPEN AT SEAT 12ABC. CORRECTIVE ACTION: REPACK PSU, OPERATIONS CHECK GOOD.SDR DALA2021070703765Fitting · crackedSHIP 3232 ER/A 588785-14AD IS GENERATED FOR THE RH AFT SPAR TO PINTLE FITTING JOINT AT HOLE 16R. (CRACK) : CORRECTIVE ACTION: PER ER/A #588785-14AD REV.ORIGINAL. OK TO CONTINUE ON MONITOR. REPETITIVE INSPECTION IS REQUIRED 25,200 FLIGHT CYCLES OR 41,400 FLIGHTSDR DALA2020121804146Bottle · low pressure1R DOOR ASSIST BOTTLE LOW. CORRECTIVE ACTION: REPLACED DOOR ASSIST BOTTLE PER 52-15. OK FOR SERVICE.SDR DALA2020120904032Bulb · inoperativeEMERGENCY EXIT LIGHT OFF, ON OVERHEAD PANEL INOPERABLE. CORRECTIVE ACTION: TRIED BULB REPLACEMENT DID NOT WORK. FAULTING DEU-A 200RH02, REPLACED DEU. OPERATIONS CHECKED OK AFTER REPLACEMENT OF DEU.SDR DALA2020120803997Housing · damagedEMERGENCY ESCAPE PATH LIGHT AT SEAT 19DEF DAMAGED. CORRECTIVE ACTION: R & R EMERGENCY LIGHT HOUSING AND TESTED LIGHTING SYSTEM. OK FOR SERVICE.SDR DALA2020112503880Bushing · migratedMIGRATED BUSHING ELEVATOR HINGE FITTING 6 LT ELEVATOR ON LT HORIZONTAL STABILIZER (2 EA). CORRECTIVE ACTION: COMPLIED WITH ER/A 537985-14 REV A AND PRI 537985-14 REV 0.SDR DALA2020112503879Hinge Fitting · migratedMIGRATED BUSH HINGE FITTING NR 5 OUTBOARD SIDE RT ELEVATOR ON RT HORIZONTAL STABILIZER (1 EA). CORRECTIVE ACTION: COMPLIED WITH ER/A 537373-14 REV A AND PRI 537373-14 REV 0.SDR DALA2020112503878Hinge Fitting · migratedMIGRATED BUSHING ELEVATOR HINGE FITTING 3 LT ELEVATOR ON LT HORIZONTAL STABILIZER (2 EA). CORRECTIVE ACTION: COMPLIED WITH ER/A 537985-14 REV A AND PRI 537985-14 REV 0.SDR DALA2020112303830Bushing · migratedCORROSION ON BUSH HINGE FITTING NR 4 OUTBOARD SIDE RT ELEVATOR ON RT HORIZONTAL STABILIZER 1 EA. CORRECTIVE ACTION: COMPLIED WITH ER/A 00-537373. OK FOR SERVICE.SDR DALA2020112303829Bushing · migratedMIGRATED BUSH HINGE FITTING NR 3 RT ELEVATOR ON RT HORIZONTAL STABILIZER 2 EA. CORRECTIVE ACTION: COMPLIED WITH ER/A 537373-14 REV A. OK FOR SERVICE.SDR DALA2020112303828Bushing · migratedMIGRATED BUSH HINGE FITTING NR 1 RT ELEVATOR ON RT HORIZONTAL STABILIZER 2 EA. CORRECTIVE ACTION: COMPLIED WITH ER/A 00-537373. OK FOR SERVICE.SDR DALA2020112303827Bushing · migratedMIGRATED BUSH HINGE FITTING NR 6 RT ELEVATOR ON RT HORIZONTAL STABILIZER 2 EA. CORRECTIVE ACTION: COMPLIED WITH ER/A 00-577373. OK FOR SERVICE.SDR DALA2020112303826Bushing · migratedMIGRATED BUSHING ELEVATOR HINGE FITTING 1 LT ELEVATOR ON LT HORIZONTAL STABILIZER 2 EA. CORRECTIVE ACTION: COMPLIED WITH ER/A 00-537985. OK FOR SERVICE.SDR DALA2020112303825Bushing · migratedMIGRATED BUSHING ELEVATOR HINGE FITTING 5 LT ELEVATOR ON LT HORIZONTAL STABILIZER 2 EA. CORRECTIVE ACTION: COMPLIED WITH ER/A 00-537985. OK FOR SERVICE.SDR DALA2021080404406Bushing · corrodedSHIP 3233 RH ELEVATOR HINGE BORE BUSHINGS FOUND CORRODED AND OUT OF TOLERANCE. CORRECTIVE ACTION: COMPLIED WITH 537373-14, REV A. ACCOMPLISH SECTION IV REPETITIVE INSPECTION WITHIN EVERY 6 YEARS. (1659976)SDR DALA2020112303823Door Frame · crackedCRACK INDICATION ON PASSENGER CREW DOOR FRAME 16 RT STOP FITTING. CORRECTIVE ACTION: REPLACED INTERCOSTAL WEB LOCATED BETWEEN FR 15 TO FR 16 AT LEVEL OF DOOR RT SIDE IN PASSENGER CABIN COMPLYING WITH ER/A 588369-14AD. OK FOR SERVICE.SDR DALA2020112303822Frame · crackedCRACK INDICATION ON FRAME 16 LT SIDE DOOR UPPER INBOARD HOLE. CORRECTIVE ACTION: COMPLIED WITH ER/A 588370-14AD. OK FOR SERVICE.SDR DALA2020112303824Stringer · corrodedCORROSION ON STRINGER 41L LOCATED BETWEEN FR 56 TO FR 57 IN AFT CARGO COMPARTMENT. CORRECTIVE ACTION: COMPLIED WITH ER/A 588505-14 REV ORIGINAL. OK FOR SERVICE.SDR DALA2020112403840Door · out of adjustPASSENGER CREW DOOR OUT OF ADJUSTMENT. CORRECTIVE ACTION: PERFORMED ADJUSTMENT OF PASSENGER CREW DOOR. OK FOR SERVICE.SDR DALA2020111903795Oxygen Box · no testFOUND PSU 02 PANEL AT 11ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXYGEN PANEL 11ABC. OPERATIONS CHECKED GOOD.SDR DALA2020111903794Oxygen Box · no testFOUND PSU 02 PANEL AT 13ABC DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXYGEN PANEL 13ABC. OK FOR SERVICE.SDR DALA2020111903793Oxygen Box · no testFOUND PSU 02 PANEL 17DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXYGEN PANEL 17DEF. OPERATIONS CHECKED GOOD.SDR DALA2020111903792Oxygen Box · no testFOUND PSU 02 PANEL 10DEF DID NOT OPEN. CORRECTIVE ACTION: REPACKED PSU OXYGEN PANEL 10DEF. OPERATIONS CHECKED GOOD.SDR DALA2020111603724Stringer · corrodedCORROSION STRINGER 42L LOCATED BETWEEN FR 56 TO FR 58 IN AFT CARGO COMPARTMENT. CORRECTIVE ACTION: PERFORMED PERMANENT REPAIR ON STRINGER LOCATED BETWEEN FR 56 TO FR 58 STR 42L IN AFT CARGO COMPARTMENT, AS PER A320 SRM 51-72-11 AND 53-00- 13-300.SDR DALA2020111603723Stringer · corrodedCORROSION STRINGER 43L LOCATED BETWEEN FR 55 TO FR 58 IN AFT CARGO COMPARTMENT. REPLACED STRINGER 43L LOCATED BETWEEN FR 53 TO FR 60 IN AFT CARGO COMPARTMENT, AS PER A320 SRM 51-72-11 AND DWG NR D53470342 RELEASE DATE 09-JUL- 20, ISSUE AZ.SDR DALA2020111103681Bearing · migratedMIGRATED PASSENGER CREW DOOR 831 UPPER BEARING FR 16 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED FOR NEW PASSENGER CREW DOOR 831 UPPER BEARING FR 16 AT FWD GALLEY AREA, AS PER A320 FAM AMM 52-11.SDR DALA2020111103680Floor Support · corrodedCORROSION FLOOR BEAM +Y1227 LOCATED FR 66 TO FR 68 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM +Y1227 LOCATED FRAME 66 TO FRAME 68 AT AFT GALLEY AREA, AS PER A320 SRM 51-72-11 AND DWG D53472780 ISSUE K RELEASE DATE 26APR18.SDR DALA2020111103679Channel · brokenBROKEN GANG CHANNEL FUEL TANK LOCATE BETWEEN RIB 15 AND 16 ON LT WING. CORRECTIVE ACTION: REPLACED GANG CHANNEL FUEL TANK LOCATED BETWEEN RIB 15 AND RIB 16, AS PER A320 SRM 51-72-11 AND DRAWING D57252451 ISSUE: S RELEASE DATE: 07-NOV -08.SDR DALA2020111103678Seat Track · corrodedCORROSION SEAT TRACK -Y1292 LOCATED BETWEEN FR 12 TO FR 24 AT FWD GALLEY AREA. CORRECTIVE ACTION: REPLACED BY NEW SEAT TRACK -Y1292 LOCATED FR 12 TO FR 24 AT FWD GALLEY AREA, AS PER A320 SRM 51-72-11 AND DWG D53112812, RELEASE DATE 08-JAN- 97, ISSUE: E00 AND SDR DALA2021070203675Frame · crackedSHIP 3277 CRACK FRAME 35 LH THAT DOES NOT EXCEED THE AUTHORIZED REPAIR AREA WAS FOUND AT THE PRESSURE PLATE AREA BETWEEN FR35LH AND FR36LH. CORRECTIVE ACTION: REPAIRED PER DELTA WORKCARD AMDS 5311-01171-04A. (1649874)
Back to Airbus A320-211