Airbus A320-212
Service difficulty reports · 8,184
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2016052404125Seat Track · corrodedCORROSION ON SEAT TRACK +765 LOCATED BETWEEN FRAME 47 TO FRAME 64 EVALUATED AND FOUND OUT LIMITS, REPLACED SEAT TRACK 765 LOCATED BETWEEN FRAME 47 TO FRAME 64 AS IAW SRM 51-72-11 AND DWG D53472770.SDR DALA2016052304124Dummy Rail · corrodedCORROSION ON RAIL DUMMY -81 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 16, REPLACED RAIL DUMMY -81 LOCATED BETWEEN FRAME 12 TO FRAME 16 AT FWD GALLEY AREA AS IAW SRM 51-72-11 AND DWG D53112828.SDR DALA2016052304123Floor Support · corrodedCORROSION ON FLOORBEAM +1292 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 24, REPLACED FLOORBEAM +1292 LOCATED BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112812, D53112758.SDR DALA2016052304122Floor Support · corrodedCORROSION ON FLOORBEAM -1292 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 24, REPLACED FLOORBEAM -1292 LOCATED BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA AS IAW SRM 51-72-11 AND DWG D53112812, D53110984.SDR DALA2016052304121Seat Track · corrodedCORROSION ON SEAT TRACK +765 FRAME 41 TO 47 EVALUATED AND FOUND OUT LIMITS ON JOB CARD N2500-2031, MEASURES, L=2.382, W=0.393, D=0.041, IN PASSENGER CABIN ON FRAME 41+9, REPLACED SEAT TRACK Y765 LOCATED BETWEEN FRAME 41 TO FRAME 47 IAW SRM A320 51-72-11 AND DWSDR DALA2016052304120Floor Support · corrodedCORROSION ON FLOORBEAM -765 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 24, REPLACED FLOORBEAM -765 LOCATED BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA AS IAW SRM 51-72-11 AND DWG D53112812, D53111462.SDR DALA2016052304119Floor Support · corrodedCORROSION ON FLOORBEAM -254 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 24, REPLACED FLOORBEAM -254 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 24 IAW SRM 51-72-11 AND DWG D53111462.SDR DALA2016052204100Floor Support · corrodedCORROSION ON FLOORBEAM -1162 AT AFT GALLEY AREA BETWEEN FRAME 67+15 TO FRAME 69, REPLACED FLOORBEAM -1162 AND FASTENERS LOCAT4ED BETWEEN FRAME 67+15" TO FRAME 69 IAW SRM 51-72-11 AND DWG D53472780 MEASURES OF CORROSION ARE: L= 1.990", W= 0.987, D= 0.065".SDR DALA2016052204099Floor Support · corrodedCORROSION ON FLOORBEAM -Y1225 AT AFT GALLEY AREA BETWEEN FRAME 66+5" TO FRAME 67+15", REPLACED FLOORBEAM -1225 AND FASTENERS LOCATED BETWEEN FRAME 66+5 TO FRAME 67+15 IAW SRM 51-72-11 AND DWG D53472832 MEASURE OF CORROSION ARE: L=1.490", W=0.880", D=0.068".SDR DALA2016052204098Stringer · corrodedCORROSION ON CENTER FITTING AT FWD GALLEY AREA ON STR 23L BETWEEN FRAME 16 TO FRAME 20, REPLACED CENTER FITTING AT FWD GALLEY AREA ON STRINGER 23L BETWEEN FRAME 16 TO FRAME 20 IAW SRM 51-72-11 AND DWG D53112109, MEASURES OF CORROSION ARE L=1.102", W=0.520", D=SDR DALA2016052204097Seat Track · corrodedCORROSION ON SEAT TRACK 765, FRAMES 41 - 47 FOUND OUT LIMITS, REPLACED THE SEAT TRACK IAW SRM 51-72-11 AND DWGS D53371000, D53370500.SDR DALA2016052204096Profile · crackedCRACK ON LOAD TRANSMITTING PROFILE EMERGENCY EXIT DOOR 844 IN PASSENG ER CABIN. LH PROFILE, REPLACED LOAD TRANSMITTING PROFILE EMERGENCY EXIT DOOR 844 IN PASSENGER CABIN LT PROFILE IAW SRM 51-72-11 AND DWG D52279010 AND D52279040.SDR DALA2016052204095Fitting · corrodedCORROSION ON CORNER FITTING FRAME 20 AT FWD GALLEY AREA ON STR 23L, REPLACED CORNER FITTING FRAME 20 AT FWD GALLEY AREA ON STRINGER 23L IAW SRM 51-72-11 AND DWG D53112109.SDR DALA2016052204094Floor Support · corrodedCORROSION ON FLOORBEAM +254 AT FWD GALLEY AREA BETWEEN FRAME 12 TO FRAME 24, REPLACED FLOORBEAM +254 LOCATED BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA ASPER SRM 51-72-11 AND DWG D53110984, DD53112816 MEASURE OF CORROSION AREA L=1.768", W=0.913", D=0.030"SDR DALA2016052004090Web · corrodedCORROSION ON WEB FRAME 20 AT FWD GALLEY AREA AND STR 23R, REPLACED WEB FRAME 20 AT FWD GALLEY AREA AND STR 23R IAW SRM 51-72-11 AND DWG D53114392.SDR DALA2016052004089Floor Support · corrodedCORROSION ON FLOORBEAM +1162 AT AFT GALLEY AREA BETWEEN FRAME 67+15" TO FRAME 69 MEASURE L=2.250" ; W=0.850"; D=0.003", REPLACED FLOORBEAM Y1162 AND FASTENERS LOCATED BETWEEN FRAME 67+15" TO FRAME 69" IAW SRM 51-72-11 AND DWG D53472780;SDR DALA2016052004088Floor Support · corrodedCORROSION ON FLOORBEAM +1225 AT AFT GALLEY AREA BETWEEN FRAME 66+5" TO FRAME 67+15" MEASURE L=1.895", W=0.250", D=0.003", REPLACED FLOORBEAM 1225 LOCATED BETWEEN FRAME 66+5" TO FRAME 67+15" IAW SRM 51-72-11 AND DWG 53472780;SDR DALA2016052004087Fitting · corrodedCORROSION ON CORNER FITTING FRAME 20 AT FWD GALLEY AREA ON STR 23R MEASURE L=0.975", W=0.285", D=0.003", REPLACED CORNER FITTING FRAME 20 AT FWD GALLEY AREA ON STR 23R IAW 51-72-11 AND DWG D53112109.SDR DALA2016051904084Floor Support · corrodedCORROSION ON FLOORBEAM +Y765 AT AFT GALLEY AREA BETWEEN FRAME 66+5" TO FRAME 70 MEASURE L=2.230, W=0.195", D=0.003". REPLACED FLOORBEAM +765 AT AFT GALLEY AREA BETWEEN FRAME 66+5" TO FRAME 70 IAW SRM 51-72-11 AND DWG D53472000.SDR DALA2016051904083Fitting · corrodedCORROSION ON CORNER FITTING FRAME 68 AT AFT GALLEY AREA AND STR 23L, REPLACED CORNER FITTING FRAME 68 AT AFT GALLEY AREA AND STR 23L IAW SRM 51-72-11 AND DWG D53480019.SDR DALA2016051904082Web · crackedCRACK SUPPORT WEB ON DOOR EMERGENCY EXIT 833 AT LOWER FUSELAGE, REPLACED SUPPORT WEB ON DOOR EMERGENCY EXIT 833 AT LOWER FUSELAGE IAW SRM 51-72-11 AND DWG D52279040, D52279010.SDR DALA2016051804081Dummy Rail · corrodedCORROSION ON RAIL DUMMY Y503.2 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 16 MEASURE ARE L=2.950", W=0.250", D=0.003", REPLACED RAIL DUMMY Y503.2 AT FWD GALLEY AREA FROM FRAME 12 TO FRAME 16 IAW SRM 51-72-11 AND DWGS 53110984, 53112825 AND 53112758.SDR DALA2016051603977Wire · misinstalled2R DOOR EMERGENCY EXIT SIGN INOPERATIVE, FOUND WIRES 3351-1305 AND 3351-1221 IN WRONG POSITION AT CONNECTOR 7244VC CORRECTED, OPS NORMAL, ALSO REPLACED 13WL EPSN AS PRECAUTIONARY .SDR DALA2016051503975Skin · damagedCORROSION FOUND ON WING CENTER TANK TOP SKIN EXTERNAL SURFACE BETWEEN FRAME 42 AND STR 16, RIB 1 DATUM AND 1292. PERMANENT REPAIR ON UPPER SKIN BETWEEN FRAME 41 TO FRAME 42 AND 1292 TO 1732 PASSENGER CABIN ON CENTER WING BOX IAW ERA 546005-14AD REVISION ORIGISDR DALA2016051503974Floor Support · corrodedCORROSION ON LOWER SILL AT STR 23L LEVEL AT AFT GALLEY AREA BETWEEN FRAME 67 TO FRAME 68, REPLACED LOWER SILL LOC BTW FRAME 66 TO FRAME 68 AT LEVEL STR 23L AFT GALLEY AREA FLOOR STRUCTURE IAW SRM 51-72-11 AND DWG D53480020.SDR DALA2016051703976Web · corrodedCORROSION FOUND ON CENTER FUSELAGE LT SIDEBOX SHELL UPPER PLATE WEB PANEL BETWEEN FRAME 42-43, PERMANENT REPAIR ON SIDE BOX UPPER SURFACE BETWEEN FRAME 42 AND FRAME 43 LT SIDE IN PASSENGER CABIN IAW PRI 546001-14, REV 0 AND ER/A 546001-14, REV B.SDR DALA2016051103871Seat Track · corrodedCORROSION ON SEAT TRACK -765 FOUND OUT LIMITS IN PASSENGER CABIN FROM FRAMES 12 - 24, REPLACED THE SEAT TRACK IAW SRM 51-72-11 AND DWG D53110900 AND D53110984.SDR DALA2016051003870Shear Tie · corrodedCORROSION ON SHEAR TIE FRAME 31 BETWEEN STR 40 - 42R IN FWD CARGO BAY. REPLACED THE SHEAR TIE IAW SRM 51-72-11 AND DWG NR D53231712 AND D53231586.SDR DALA2016050703768Floor Support · corrodedCORROSION ON FLOORBEAM 1292 LOCATED BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA, REPLACED FLOORBEAM 1292 LOCATED BETWEEN FRAME 12 TO FRAME 24 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWGS D53112812 AND D53110900.SDR DALA2016050603767Web · corrodedCORROSION ON WEB ON FLOOR STRUCTURE AT LEVEL STR 23L, FRAME 20 AT FWD GALLEY AREA, REPLACED WEB ON FLOOR STRUCTURE AT LEVEL STR 23L, FRAME 20 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112784.SDR DALA2016050603766Web · corrodedCORROSION ON WEB ON FLOOR STRUCTURE AT LEVEL STR 23R AND FRAME 20 AT FWD GALLEY AREA REPLACED WEB ON FLOOR STRUCTURE AT LEVEL STR 23R AND FRAME 20 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53112784.SDR DALA2016050503765Floor Support · corrodedCORROSION ON LOWER SILL LOCATION FRAME 66 TO FRAME 68 RT SIDE AT AFT GALLEY AREA . REPLACED LOWER SILL LOCATED FRAME 66 TO FRAME 68RT SIDE AT AFT GALLY AREA IAW SRM 51-72-11 AND DWG D53480019.SDR DALA2016050503764Floor Support · corrodedCORROSION ON FLOORBEAM 1162 BETWEEN FRAME 68 TO FRAME 69 AT AFT GALLEY AREA. REPLACED FLOOR BEAM 1162 BETWEEN FRAME 68 TO FRAME 69 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472780.SDR DALA2016050503763Floor Support · corrodedCORROSION ON LOWER SILL LOCATION FRAME 66 TO 68 LT SIDE AT AFT GALLEY AREA, REPLACED FLOOR SILL LOCATION FRAME 66 TO 68 LT SIDE AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480019.SDR DALA2016050503762Floor Support · corrodedCORROSION ON FLOORBEAM 1162 BETWEEN FRAME 68 TO FRAME 69 AT AFT GALLEY AREA. REPLACED FLOORBEAM 1162 BETWEEN FRAME 68 TO FRAME 69 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472780 MEASURES OF REWORKED AREA: L=5.054", W=2.132", D=0.041".SDR DALA2016050503761Floor Support · corrodedCORROSION ON FLOOR SUPPORT 1589, FRAMES 65 TO 66 IN AFT GALLEY. REWORKED AND EVALUATED OUT OF LIMITS IAW SRM 53-00-14, TABLE 101, PARA 4.B, FIG 102, SHEET 1. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53474250.SDR DALA2016050503760Floor Support · corrodedCORROSION ON FLOOR SUPPORT 1589 BETWEEN FRAMES 65 TO 66 AT AFT GALLEY AREA. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DWG D53474250.SDR DALA2016050503759Floor Support · corrodedCORROSION ON FLOORBEAM 1225 BETWEEN FRAME 66 TO FRAME 68 AT AFT GALLEY AREA L=1.256", W=0.978", D=0.004". REPLACED FLOORBEAM 1225 BETWEEN FRAME 66 TO FRAME 68 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472780, MEASURES OF REWORKED AREA: L=1.790", W=1.18SDR DALA2016050403758Floor Support · corrodedCORROSION ON FLOORBEAM 465, FRAME 64 TO FRAME 66 AT AFT GALLEY AREA L= 1.300", W=0.786", D=0.005". REPLACED FLOORBEAM 465 LOCATED, FRAME 64 TO FRAME 67+10 AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53472816; MEASURES OF CORROSION ARE L=1.315", W=1.000", D=SDR DALA2016050403757Fitting · corrodedCORROSION ON CORNER FITTING FRAME 68 LT SIDE AT AFT GALLEY AREA. REPLACED CORNER FITTING FRAME 68 LT SIDE AT AFT GALLEY AREA IAW SRM 51-72-11 AND DWG D53480019.SDR DALA2016050303592Rail · crackedCRACK ON UPPER RAIL ON SLIDING WINDOW LT IN COCKPIT, PERFORMED PERMANENT REPAIR ON UPPER RAIL ON SLIDING WINDOW IAW SRM 53-11-12, PARA 5.C, FIG 203, SHEET 1.SDR DALA2016050303591Skin · damagedSEVERAL SCRATCHES FOUND ON EXTERNAL SKIN BETWEEN FRAME 44-FRAME 45 AT THE ADF ANTENNA. PERFORMED TIME LIMITED REPAIR ON EXTERNAL SKIN BTE FRAME 44 TO FRAME 45 AND BETWEEN STR 1L TO STR 1R ON UPPER FUSELAGE IAW PRI 545992-14, SECTION I, REV 0 AND ERA 545992-14SDR DALA2016050303593Floor Support · corrodedCORROSION ON FLOORBEAM +1292 LOCATION BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA, REPLACED FLOORBEAM +1292 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53110920.SDR DALA2016050103589Rail · crackedCRACK ON UPPER RAIL ON SLIDING WINDOW RT IN COCKPIT, PERFORMED PERMANENT REPAIR ON UPPER RAIL ON SLIDING WINDOW IAW SRM 53-11-12, PARAGRAPH 5C, FIG 203, SHEET 1.SDR DALA2016050103588Panel · corrodedCORROSION REINFORCING PLATE ON POTABLE WATER PANEL 171AL IN AFT CARGO COMPARTMENT FROM FRAME 65 TO FRAME 66 BETWEEN STR 41L TO STR 37L, REPLACED REINFORCEMENT, PLATE, LOCATED BETWEEN FRAME 65 TO FRAME 66 AND AND STR 41L TO STR 37L ON POTABLE WATER PANEL 171AL SDR DALA2016050103587Seat Track · corrodedCORROSION ON SEAT TRACK -Y1292, FRAME 47 TO 64 EVALUATED AND FOUND OUT LIMITS MEASURES OF CORROSION ARE: L=4.111", W=0.231", D=0.057". REPLACED SEAT TRACK 1292 FRAME 47 TO FRAME 64 IN PASSENGER CABIN IAW SRM 51-72-11 AND DWG D53470080.SDR DALA2016050203590Power Supply · faultedFOUND FWD LT EPSU FAULT, REPLACED EPSU.SDR DALA2016043003586Frame · crackedCRACK SECTION FRAME 68 AND STR 23L ON CROSSBEAM AT AFT GALLEY AREA, REPLACED SECTION FRAME 68 LOCATED AT STR 23L ON CROSSBEAM AT AFT GALLEY AREAS IAW SRM 51-72-11, SRM 51-42-11, D53474250, MEASURES OF CRACK IS L=0.350".SDR DALA2016043003585Floor Support · corrodedCORROSION ON FLOORBEAM -Y765, LOC FR 66 TO FR 70 AT AFT GALLEY AREA, L=2.500", W=1.500", D=0.005, REPLACED FLOORBEAM 765 LOCATED BETWEEN FRAME 66 TO FRAME 70 AT AFT GALLEY AREA SRM 51-72-11, DWS D53472093 AND D53472780, REWORKED AREA MEASURES L=1.931", W=1.33SDR DALA2016042903453Floor Support · corrodedCORROSION ON FLOORBEAM 254 LOCATED BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA, REPLACED FLOORBEAM 254 LOCATED BETWEEN FRAME 16 TO FRAME 20 AT FWD GALLEY AREA IAW SRM 51-72-11 AND DWG D53110984.
Back to Airbus A320-212