Airbus A320-212
Service difficulty reports · 8,184
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA12016253248Connector · damagedDURING SERVICE CHECK, FOUND ESCAPE PATH LIGHT AT SEAT 13C, INOPERATIVE. FOUND BAD CONNECTOR AT FLOOR. SECURED AND FUNCTIONAL CHECK WAS GOOD.SDR DALA12016043270Power Supply · inoperativeDURING EMERGENCY ELECTRICAL TEST BOTH FWD EMERG EXIT LIGHTS, ROW 4, 5, 6 AND ROW 2,3 EVACUATION LIGHTS INOPERATIVE. REPLACED 10WL EPSU IAW TSM 33-51-00. TEST OK. OK FOR SERVICE.SDR DALA12016033270Battery Pack · malfunctionedDURING EMERGENCY LIGHT SYS TEST EPSU BATTERY EMERGENCY LIGHT MESSAGE. MX REPLACED EPSU BATTERY PACK 11WL AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12016023275Power Supply · inoperativeDURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHTS AT FORWARD GALLEY AND F/C INOPERATIVE. MX REPLACED EMERGENCY POWER SUPPLY UNIT AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12015443241Connector · damagedDURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHT AT ROW 18ABC INOPERATIVE. MX REPAIRED CONNECTION AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12013963269Battery · inoperativeDURING EMERGENCY LIGHTS TEST, FOUND EPSU BATTERY PACK RT MESSAGE. APPLIED TSM 33-51-00-810-802A. PERFORMED OPS TEST OF THE EMERGENCY LIGHT SYS. FAULT CONTINUES. PERFORMED OPS TEST OF THE BATTERY PSEU. BATTERY FAULT APPEARS. R & R BATTERY IAW AMM 33-51. TESDR DALA12012503253Wire · brokenDURING NON ROUTINE CHECK, FOUND EMERGENCY ESCAPE PATH LIGHT AT SEAT 3A-B INOPERATIVE. MX REPAIRED BROKEN WIRE AT SEAT 3A-B AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12012463263Connector · unsecureDURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHT TEST FAILS EPSU INT LOAD AFT LEFT. MX RESEATED CONNECTOR AT EPSU 13WL AND FUNCTIONAL CHECK WAS NORMAL..SDR DALA12011963271Battery Pack · inoperativeDURING NON ROUTINE CHECK, FOUND EMERGENCY ESCAPE LIGHTS AT 1L WILL NOT PASS TEST. MX REPLACED BATTERY PACK AT 1L AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12011953269Epsu · failedDURING SERVICE CHECK, FOUND LEFT ESPU BATTERY FAIL TEST. MX REPLACED LT ESPU AND FUNCTIONAL CHECKED NORMAL.SDR DALA12011613268Wire · brokenEMERGENCY EXIT ROW LIGHT'S OF ROW 3 SEAT B HAS A BROKEN WIRE CAUSING THE LIGHT TO BE INOPERATIVE. REPAIRED WIRING AT SEAT 3B, SECURED AND REPLACED LEN'S COVER. OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA1509763258Structure · damagedRT INBD FLAP DAMAGED. REPAIRED.SDR DALA12010763244Wire · disconnectedDURING NON ROUTINE CHECK, FOUND EMERGENCY FLOOR LIGHTING AT ROW 2AB INOPERATIVE. FOUND BLACK WIRE TO LIGHT SOCKET PULLED OUT. REPLACED AFT LIGHT SOCKET AT SEAT 2B FOR EMERGENCY PATH LIGHTING AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12010753271Power Supply · malfunctionedDURING NON ROUTINE CHECK, FOUND EPSU AT MID LT CAUSING BATTERY FAULTS. MX REPLACED MID LT EPSU AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12010623242Light · missingDURING NON ROUTINE CHECK, FOUND SEAT 23C EMERGENCY PATH LIGHT MISSING. MX REPLACED SEAT 23C ESCAPE PATH LIGHT AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12010743271Skin · dentedDURING INSPECTION, FOUND FWD LT SIDE OF EXTERNAL FUSELAGE BETWEEN FR 21 - FR 23, BTW STR 23 - 24L SKIN DENTED. DENT IS OUT OF NEARNESS/FORM CRITERION IAW SRM 53-11-11, DIAGRAM 103. PERFORMED VISUAL INSPECTION ON EXTERNAL SKIN AND FASTENERS, NO OTHER DAMAGE SDR DALA12010233276Wire · damagedF/A REPORTED EMERGENCY FLOOR LIGHT DAMAGED OR INOPERATIVE AT 26C. MX RESECURED WIRES AND OPS CHECKED NORMAL.SDR DALA12010223276Wire · unsecureF/A REPORTED EMERGENCY FLOOR LIGHT DAMAGED OR INOPERATIVE AT 25C. MX RESECURED WIRES AND OPS CHECKED WAS NORMAL.SDR DALA12010213271Sill · corrodedDURING INSPECTION, FOUND AFT UTILITY LT DOOR SILL HAS CORROSION, 4 AREAS AT FR 68 ON FLOOR SUPPORT SECTION. BLENDED AREAS IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-41-14, FIG 101. CUTOUT DAMAGE L=8.3" X W=.90". FABRICATED REPAIR ANGLE. ACCOMPLSDR DALA12009953271Sill · corrodedDURING INSPECTION, FOUND AFT UTILITY RT DOOR SILL HAS 4 AREAS OF CORROSION BETWEEN FR 66 AND FR 68 FLOOR SUPPORT SECTION AS MARKED. ACCOMPLISHED ANGLE REPAIRS AT BOTH FR 66 & FR 68 IAW SRM 53-41-14, FIG 201 & ER/A'S 506753-14 & 506756-14. REF LP 0608213 FOR SDR DALA12010563271Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151QF DAMAGED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010553271Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151QF DAMAGED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010543271Floor Panel · puncturedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151RF PUNCTURED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010533271Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151MF DAMAGED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010523271Floor Panel · puncturedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151CF PUNCTURED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010513271Floor Panel · damagedDURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131GF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010503271Floor Panel · puncturedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151NF PUNCTURED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010493271Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151EF DAMAGED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010483271Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 152QF DAMAGED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010473271Floor Panel · delaminatedDURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131AF DELAMINATED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010463271Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161BF DAMAGED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010453271Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151DF DAMAGED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010443271Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 161CF DAMAGED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010433271Floor Panel · damagedDURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131HF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010423271Floor Panel · delaminatedDURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131EF DELAMINATED. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010413271Floor Panel · damagedDURING INSPECTION, FOUND FWD CARGO FLOOR PANEL 131JF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW DWG 3D25-37705.SDR DALA12010403271Panel · puncturedDURING INSPECTION, FOUND FWD CARGO BAY SLOPE PANEL 131BF PUNCTURED. FABRICATED FWD CARGO SLOPE PANEL IAW DWG 3D25-37705.SDR DALA12010393271Panel · damagedDURING INSPECTION, FOUND AFT CARGO SLOPE PANEL 151HF DAMAGED. FABRICATED AFT CARGO SLOPE PANEL IAW DWG 3D25-37705.SDR DALA12010383271Floor Panel · damagedDURING INSPECTION, FOUND AFT CARGO FLOOR PANEL 151 GF DAMAGED. FABRICATED AFT CARGO SLOPE PANEL IAW DWG 3D25-37705.SDR DALA12010373271Panel · damagedDURING INSPECTION, FOUND AFT CARGO SLOPE PANEL 151FF DAMAGED. FABRICATED AFT CARGO SLOPE PANEL IAW DWG 3D257705.SDR DALA12009943271Floor Panel · corrodedDURING INSPECTION, FOUND MAIN CABIN R1 DOOR ENTRY FLOOR PANEL 222FF CORRODED AROUND BOTTOM EDGES. REPLACED FLOOR PANEL IAW SRM 51-72-11. DAMAGED DIMENSION L=5.0"W=2.0"D=0.030".SDR DALA12009933271Floor Panel · corrodedDURING INSPECTION, FOUND MAIN CABIN L1 DOOR ENTRY FLOOR PANEL 221FF CORRODED AROUND BOTTOM EDGES. REPLACED FLOOR PANEL IAW SRM 51-72-11. DAMAGED DIMENSION L=6.0"W=2.0"D=0.025".SDR DALA12009823271Bracket · damagedDURING INSPECTION, FOUND RT OTBD FLAP CUSHION SEAL UPPER RETAINING SCREW HOLE MISDRILLED ON NR 1 FLAP RIB. R & R RIB 1 BRACKET IAW SRM 51-42-11.SDR DALA12009813271Floor Panel · damagedDURING INSPECTION, FOUND AFT CABIN FLOOR PANEL 261FF DAMAGED. REPLACED FLOOR PANEL IAW SRM 5172-11.SDR DALA12009803271Floor Panel · delaminatedDURING INSPECTION, FOUND FWD CABIN UTILITY FLOOR PANEL 232DF IS DELAMINATED. FABRICATED FLOOR PANEL IAW DWG 3D25-37498.SDR DALA12009793271Floor Panel · damagedDURING INSPECTION, FOUND FWD CABIN FLOOR PANEL 221DF HAS DAMAGED INSERT. FABRICATED FLOOR PANEL IAW DWG 3D25-37498.SDR DALA12009783271Floor Panel · damagedDURING INSPECTION, FOUND CTR CABIN FLOOR PANEL 242FF HAS EDGE DAMAGE. FABRICATED FLOOR PANEL IAW DWG 3D25-37498.SDR DALA12009743271Floor Support · corrodedDURING INSPECTION, FOUND AFT B UTILITY LT DOOR SILL HAS CORROSION ON FLOOR SUPPORT SECTION AT FR66. LT AFT DOOR SILL REPAIR AT FR66 HAS BEEN ACCOMPLISHED IAW ER/A 506755-14, REV ORIG SECTION I PERMANENT REPAIR & SRM 53-41-14 FIG 201 REPAIR PRINCIPLE 6. THIS SDR DALA12009593271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY -Y1292 FLOOR SUPPORT BETWEEN FR 66 AND 68 HAS CORROSION AROUND FASTENERS AND FASTENER HOLES. REMOVED CORROSION IAW SRM 51-74-00. ORIG MAT .087" DAMAGE " W=0.3" =.037" FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15, FIG 1. RSDR DALA12009583271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY -Y1292 FLOOR SUPPORT BETWEEN FR 64 AND 66 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00 AND WAS FOUND TO BE OUT OF LIMIT. REPLACED FLOOR SUPPORT IAW TO SRM 51-42-11.
Back to Airbus A320-212