SDR DALA12009573271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY -Y1292 FLOOR SUPPORT BETWEEN FR 69 AND 69 IS CORRODED AROUND FASTENERS. REMOVED CORROSION IAW SRM 51-74-00. ORIG MAT .157" DAMAGE DIM L=1.9" W=0.7" D=.051" FOUND TO BE OUT OF LIMITS IAW TRM53-41-15, FIG 1. REPLACED FLOOR SDR DALA12009473271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY Y1292 FLOOR SUPPORT HAS EXFOLIATION AROUND HARD POINT MOUNT HOLE BETWEEN FR 64 AND FR 66. REPLACED FLOOR SUPPORT AT FR 64- FR 66 Y1292 IAW SRM 51-42-11. ORG MAT. .087" MAT LOSS L=4.0" W=1.5" D=.087" FOUND TO BE OUT OF LIMISDR DALA12009463271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY Y1292 FLOOR SUPPORT HAS CORROSION AROUND FASTENER HOLES AND UPPER SURFACE BETWEEN FRAME 66 AND 68. REPLACED FLOOR SUPPORT AT FR 66 - FR 68 Y1292 IAW SRM 51-42-11, ORG MAT .087" MAT. LOSS L=1.0" W=1.0" D=.036". FOUND TO BESDR DALA12009453271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY Y1292 FLOOR SUPPORT HAS CORROSION AROUND FASTENERS AND FASTENER HOLES BETWEEN FR 68 AND 70. SSI 534147.NR 260-83. REPLACED FLOOR SUPPORT AT FR 68 AND 70 Y1292 SRM 51-42-11, ORG MAT .157" MAT.LOSS L=1.0 W=1.0 .064 FOUND TO SDR DALA12009433271Web · corrodedDURING INSPECTION, FOUND AFT UTILITY RT SIDE WEB BETWEEN FR 68 AND FR 69 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. L=0.5", W=0.5", D=0.020". NO ALLOWABLE LIMITS FOUND IN SRM. REPLACED SHEAR TRAY IAW SRM 51-42-11.SDR DALA12009563271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY -Y465 FLOOR SUPPORT HAS 4 AREAS WITH HEAVY CORROSION BETWEEN FR 64 AND 67. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS AFTER REWORK. ORIG MAT. .149" DAMAGE DIM. L=1.1" W=1.0" D=.040" IAW SRM 53-00-14, SDR DALA12009293271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY -Y765 FLOOR SUPPORT HAS 4 LARGE AREAS OF EXFOLIATION BETWEEN FR66 AND 70. BLENDED AREA IAW SRM 51-74-00, DIM OF BLENDOUT AREA, ORIGINAL MAT. 0.157" L=1.25" W=1.1" D=0.065 FOUND TO BE OUT OF LIMITS IAW SRM 53-41-15, FIG 1SDR DALA12009283271Sill · corrodedDURING INSPECTION, FOUND R2 DOOR CUT OUT CENTER SHAPE SILL CORRODED. REMOVED CORROSION IAW SRM 51-74-00. DIMENSION OF REWORKED AREA ORIGINAL MAT. 0.100 L=1.65" W=0.600" D=0.030" NO ALLOWABLE DAMAGE FOUND IN THE SRM. REPLACED SHAPE SILL IAW SRM 51-42-11.SDR DALA12009303271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FR 20 FLOOR SUPPORT -Y765 HAS CORROSION. BLENDED CORROSION IAW SRM 51-74-00.L=2.0 W=1.060 D=0.079. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14 REPLACED FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12009203271Shear Plate · corrodedDURING INSPECTION, FOUND AFT UTILITY RT SHEAR PLATE SUPPORT BETWEEN FR69 AND FR70 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00, DIM OF BLENDED OUT ARE: L= 1.5" W=1.0" D=0.020" NO ALLOWABLE LIMITS FOUND IN SRM. REMOVED DAMAGED SHEAR PLATE SUPPORT IAW SRM 51-SDR DALA12009193271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FR20 FLOOR SUPPORT WEB -Y1732 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. BLEND SIZE:L=3.0" W=1.5" D=.035".NO LIMIT ON SRM. REPLACED FLOOR SUPPORT (WEB) PN D5311278520301 IAW SRM 51-42-11, SRM 51-SDR DALA12009183271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA BTW FR16 - FR21 FLOOR SUPPORT -Y254 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00(6PLS) BLEND SIZE 2"W X 6 "L X .025"D, 2.5"L X 2"W X .028"D, 3"L X 1.4"W X .012"D, 2.8"L X 1.2"W X .013"D, 1.3" X .8"X .0SDR DALA12009153271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FR16 -FR20 FLOOR SUPPORT Y1292 HAS CORROSION. BLENDED AREA IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. LOCATED & DRILLED NEW FLOOR SUPPORT IAW SRSDR DALA12009073271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FR16 FLOOR SUPPORT Y940 HAS CORROSION. BLENDED FLOOR SUPPORT IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 106, REPLACED WITH NEW FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12009063271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FR 20 FLOOR SUPPORT Y765 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14. R & R FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12009053271Floorbeam · corrodedDURING INSPECTIONS, FOUND AFT UTILITY Y765 HAS CORROSION AROUND HARD POINT MOUNT HOLE ABOVE FR66. REMOVED CORROSION IAW SRM 51-74-00 FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15 FIG 1. REPLACED FLOORBEAM IAW SRM 51-42-11.SDR DALA12009043271Floor Support · corrodedDURING INSPECTIONS, FOUND MAIN CABIN FWD UTILITY AREA, FR 16-21 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. FOUND OUT OF LIMITS IAW SRM 53-11-14, FIG 106. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12009033271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA BETWEEN FR 16-21 FLOOR SUPPORT HAS SEVERAL CORROSION. BLENDED DAMAGED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 102, REMOVED DAMAGED FLOOR SUPPORT IAW SRM 51-42-11, INSTALLED NSDR DALA12009143271Floor Support · corrodedDURING INSPECTION, FOUND MAIN CABIN FWD UTILITY AREA FLOOR SUPPORT CORRODED. BLENDED CORROSION IAW SRM 51-74-00. FOUND OUT OF LIMITS IAW SRM 51-11-14 FIG 103. REPLACED FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12008923263Wire · brokenDURING NON ROUTINE CHECK, FOUND SEAT 26C EMERGENCY PATH LIGHT INOPERATIVE. MX REPAIRED BROKEN WIRE UNDER SEAT AND FUNCTIONAL CHECKED NORMAL.SDR DALA12009133271Floor Support · corrodedDURING INSPECTION, FOUND AFT UTILITY FLOOR SUPPORT HAS CORROSION. BLENDED AREAS IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15 FIG 1. REMOVED DAMAGED FLOOR SUPPORT IAW SRM 51-42-11. INSTALLED NEW FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12008913271Floor Support · corrodedDURING INSPECTIONS, FOUND MAIN CABIN UTILITY AREA BTW FR 20-21 FLOOR SUPPORT -Y189 HAS CORROSION. BLENDED AREA L=2.0"W=1.0"& 0.150" FOUND OUT OF LIMITS IAW SRM 53-11-14. R & R FLOOR SUPPORT IAW SRM 51-42-11.SDR DALA12008903209Epsu · inoperativeDURING NON-ROUTINE CHECK, FOUND AFT LT EPSU INOPERATIVE. MX REPLACED AFT LT EPSU AND BATTERY PACK. FUNCTIONAL CHECKED NORMAL.SDR DALA12008893270Connector · looseDURING NON ROUTINE CHECK, FOUND SEAT MOUNTED EMERGENCY ESCAPE PATH LIGHTS AT 03B AND 12C INOPERATIVE. MX SPLICE, CONNECTED LOOSE CONNECTOR AND FUNCTIONAL CHECKED NORMAL.SDR DALA12008473249Battery Pack · inoperativeFLT 1156, CREW REPORTED EMERGENCY LIGHTS INOPERATIVE. MX REPLACED BATTERY PACK AND FUNCTIONAL CHECKED NORMAL.SDR DALA12008463237Wire · looseDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT 26C INOPERATIVE. MX REPAIRED LOOSE WIRE, LAMPED AND FUNCIONAL CHECKED NORMAL.SDR DALA12008273253Light · disconnectedDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT 20 INOPERATIVE. MX RECONNECTED AND FUNCTIONAL TEST WAS NORMAL.SDR DALA12008453249Lamp · inoperativeDURING NON-ROUTINE CHECK, FOUND EMERGENCY LIGHTS AT ROWS 9 AND 22 INOPERATIVE. MX REPAIRED AND LAMPED EMERGENCY LIGHTS AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12007603238Skin · dentedGROUND CREW REPORTED LOWER FUSELAGE NOSE DENTED. EXTENDS FROM RT SKIN AIR VALVE TO 4 FT FORWARD. TRIMMED OUT DAMAGE, INSPECTED, FABRICATED FILLERS AND INSTALLED .090" DOUBLER IAW ER/A 507020-14 SECT 1 REV ORIGINAL.SDR DALA12006973272Wire · brokenDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT 1AB AND 2AB INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA1502823254Skin · buckledFUSELAGE SKIN BUCKLED, FR63-64. REPAIRED IAW SRM 53-41-11.SDR DALA12006473250Battery Pack · inoperativeDURING NON ROUTINE CHECK, FOUND EMERGENCY LIGHT SYSTEM FAILED EPSU TEST AT FWD LT. MAINTENANCE REPLACED BATTERY PACK AND OPERATIONAL CHECK WAS NORMAL.SDR DALA12006453266Battery Pack · inoperativeDURING NON ROUTINE CHECK, FOUND THE EMERGENCY EPSU BATTERY FAILED TEST. MAINTENANCE REPLACED BATTERY PACK AND FUNCTION TESTED NORMAL.SDR DALA12006443269Light · looseDURING NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT 1B INOPERATIVE. MAINTENACE SECURED LIGHT ASSEMBLY AND FUNCTIONAL CHECKED NORMAL.SDR DALA12005783257Connector · disconnectedDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT 19ABC INOPERATIVE. MAINTENANCE RECONNECTED ELECTRICAL CONNECTOR AND FUNCTIONAL TEST WAS NORMAL.SDR DALA12005743235Wire · looseDURING NON ROUTINE CHECK, FOUND THE EMERGENCY FLOOR PATH LIGHT AT ROW 24C INOPERATIVE. MAINTENANCE SECURED LOOSE WIRE AT ROW 24C AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12005693261Battery · faultyDURING NON ROUTINE CHECK, FOUND EPSU AFT L EMERGENCY BATTERY FAULT. MAINTENANCE REPLACED BATTERY AT AFT L AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12005683261Battery · faultyDURING NON ROUTINE CHECK, FOUND EPSU L EMERGENCY BATTERY FAULT. MAINTENANCE REPLACED BATTERY AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12005633235Light · inoperativeDURING NON ROUTINE CHECK, FOUND EMERGENCY EXIT LIGHT HAS MANY BURNT LAMPS. MAINTENANCE REPLACED LAMPS AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12005623235Light · inoperativeDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT 23C INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12005393245Wire · brokenDURING NON ROUTINE CHECK, FOUND THE EMERGENCY LIGHT AT SEAT 24C INOPERATIVE. MAINTENANCE REPAIRED A BROKEN WIRE AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12005383243Battery · faultyDURING NON ROUTINE CHECK, FOUND THE EPSU BATTERY AT FWD LEFT OF 10WL FAULT. MAINTENANCE REPLACED BATTERY AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA12005243235Battery Pack · inoperativeDURING NON ROUTINE CHECK, EMERGENCY LIGHT AT 1C FAILED TEST. MAINTENANCE REPLACED BATTERY PACK AND FUNCTIONAL TEST WAS NORNAL.SDR DALA12002383269Battery Pack · inoperativeEMERGENCY LIGHT TEST FAULTS EPSU BATTERY FORWARD LEFT. REMOVED AND REPLACED BATTERY PACK AT 10WL L-1 DOOR PER AMM 33-51-58. NOW TESTED GOOD.SDR DALA12001893269Lamp · inoperativeDURING NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT 1B INOPERATIVE. MAINTENANCE REPAIRED ASSEMBLY AND RELAMPED. OPERATIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA12001793269Structure · dentedNR 2 LEFT MAIN ENTRY DOOR DENTED AT LOWER AFT CORNER. MAINTENANCE REMOVED DAMAGE AND FABRICATED REPAIR PARTS PER ERA 504635-14 REV O. PERFORMED DETAILED VISUAL INSPECTION. NO FURTHER DAMAGE NOTED. INSTALLED REPAIR AND RESTORED ACCESS PER SECT 2 PERM REPAIRSDR DALA12001583241Lamp · inoperativeEMERGENCY LIGHT BULBS IN THE CABIN EXIT SIGNS INOPERATIVE. MAINTENANCE RELAMPED AND FUNCTIONAL CHECKED NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA12001283234Wire · brokenDURING NON ROUTINE CHECK, FOUND EMERGENCY ESCAPE PATH LIGHT AT ROW 20 INOPERATIVE. MAINTENANCE REPLACED BROKEN WIRE AT SOCKET ASSEMBLY AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA12000673252Light · inoperativeDURING NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT 15 INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AND OPS CHECKED NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA12000313270Connector · brokenDURING NON ROUTINE CHECK, FOUND SEAT ROWS 1AB AND 15ABC EMERGENCY PATH LIGHTS INOPERATIVE. MAINTENANCE INSTALLED A NEW CONNECTORS TO REPLACE BROKEN CONNECTORS AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.
Back to Airbus A320-212