Airbus A320-212
Service difficulty reports · 8,184
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1122863269Connector · looseDURING EMERGENCY LIGHT TEST FOUND SEAT ROW 4B INOP. LOOSE CONNECTOR SECURED AND TESTS OK.SDR DALA1122853269Connector · looseDURING EMERGENCY LIGHT TEST FOUND SEAT ROW 6C INOP. LOOSE CONNECTOR SECURED AND TESTS OK.SDR DALA1122103251Floor Panel · delaminatedFWD PIT FLOOR PANEL 131AF IS DELAMINATED 6" X 6" AREA. REMOVED FLOOR PANEL 131AF IAW AMM 53-22-14. RECEIVED NEW PANEL 131AF; P/N DA-D5367200300000. INSTALLED IAW AMM 53-22-14. FABRICATED IAW STAM TRAVELER T11/876289 REF DWG 3D25-37705.SDR DALA1122873273Connector · looseDURING EMERGENCY LIGHT TEST FOUND SEAT ROW 5/6 INOP. SECURED CONNECTOR IN SIDE WALL AND TESTS OK.SDR DALA1122833251Skin · corrodedLOWER FUSELAGE SKIN BET FR 69 AND FR 70 AROUND WASTE TANK VACUUM VENT HOLE HAS CORROSION. REMOVED CORR IAW SRM 51-74-00. REMAINING FOUND TO BE OUT OF LIMITS IAW SRM 53-41-11, CUT OUT DAMAGED AREA IAW SRM 53-41-11, HFEC TRIMMED AREA IAW NTM 51-10-08, NO CRACKSDR DALA1121953248Wire · damagedDURING EMERGENCY LIGHT TEST FOUND AFT EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPAIRED A WIRE ON THE LIGHT ASSEMBLY AND TESTS OK.SDR DALA1122843245Light · brokenDURING EMERGENCY LIGHT TEST FOUND SEAT ROW 11 INOP. REPLACED BROKEN LIGHT ASSEMBLY AND TESTS OK.SDR DALA1119923271Connector · unsecureDURING EMERGENCY LIGHT TEST FOUND SEAT 7C PATH LIGHT INOP. SECURED CONNECTOR AND TESTS OK.SDR DALA1119913234Pin · brokenDURING EMERGENCY LIGHT TEST FOUND SEAT 5C PATH LIGHT INOP. REPAIRED BROKEN CONTACT PIN AND TESTS OK.SDR DALA1119893234Pin · brokenDURING EMERGENCY LIGHT TEST FOUND SEAT 22C PATH LIGHT INOP. REPAIRED BROKEN CONTACT PIN AND TESTS OK.SDR DALA1119883234Pin · brokenDURING EMERGENCY LIGHT TEST FOUND SEAT 23C PATH LIGHT INOP. REPAIRED BROKEN CONTACT PIN AND TESTS OK.SDR DALA1118863272Epsu · failedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY LIGHT EPSU UNIT FORWARD LEFT FAILED. MAINTENANCE REPLACED THE EMERGENCY LIGHT EPSU UNIT AND FUNCTIONAL CHECK WAS NORMAL.SDR DALA1118873255Wire · damagedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT ROW 17ABC INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE AND PERFORMED FUNCTIONAL CHECK. CHECK WAS NORMAL. A/C RETURNED TO SERVICE.SDR DALA1119903253Wire · brokenDURING EMERGENCY LIGHT TEST FOUND PATH LIGHT FWD OF LEFT LAV DOOR INOP. REPAIRED BROKEN WIRES IN LAVATORY WALL AND TESTS OK.SDR DALA1115473257Epsu · faultedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY LIGHT SYS TEST FAULTS ESPU INTERNAL LOAD FOR SIGN 53L. MX REPLACED ESPU AND FUNCTIONAL TEST WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1116523272Wire · brokenCREW REPORTED EMERGENCY PATH LIGHT AT 1, 2, 7, 8 AND 10 ABC ARE INOPERATIVE. MAINTENANCE REPAIRED BROKEN WIRE, RE-LAMPED AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1115183263Wire Harness · inoperativeDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY ESCAPE PATH LIGHT AY AT ROW 22C INOPERATIVE. MAINTENANCE REPLACED HARNESS AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1109863274Dummy Rail · corrodedFWD DUMMY RAIL +Y503.2 IS CORRODED AT FRAME. BLENDED OUT CORRODED AREA IAW SRM 51-74-00, L=2.2" W=2.1" MAX DEPTH=0.079", ORIGINAL MATERIAL THICKNESS =0.079", FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 103. R & R DUMMY RAIL IAW SRM 51-42-11. INSTALLED NESDR DALA1109843274Stringer · corrodedNEED TO REMOVE FLOOR PANEL 221FF TO ACCESS STRINGER REPAIR. REMOVED FLOOR PANEL 221FF IAW AMM 53-12-12. UPON REMOVAL OF FLOOR PANEL 221FF FOUND CORROSION ON BOTTOM OF PANEL. NO ALLOWABLE LIMITS FOR PANEL. INSTALLED NEW FLOOR PANEL IAW AMM 53-12-12.SDR DALA1109833274Floorbeam · corrodedFWD CABIN FLOORBEAM -254 IS CORRODED AT FR 18. ORIGINALTHICKNESS .079" FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. REMOVED FLOORBEAM AND SPLICE IAW SRM 51-42-11. RECEIVED NEW FLOORBEAM AND MACHINED BEAM AFT END TO FIT SPLICE IAW ER/A 489275-14. LOCATED AND DSDR DALA1109453274Floorbeam · corrodedFWD CABIN FLOORBEAM +Y1292 IS CORRODED AT FR 16 BLENDED OUT CORRODED AREA IAW SRM 51-74-00, L=7.0" W=1.5" D=0.045", ORIGINAL MATERIAL THICKNESS 0.079", FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 105. REMOVED FLOORBEAM IAW SRM 51-42-11. INSTALLED NEW FLSDR DALA1109443274Dummy Rail · corrodedFWD CABIN DUMMY RAIL, Y-189 IS CORRODED AT FRAME 20. BLENDED OUT CORRODED AREA IAW SRM 51-74-00, L=2.0" W=1.0", D=0.051". ORIGINAL MATERIAL THICKNESS 0.080", FOUND TO BE OUTOF LIMITS IAW SRM 53-11-14, FIG 105. REMOVED DAMAGED DUMMY RAIL IAW SRM 51-42-11, INSDR DALA1109433274Floorbeam · corrodedFWD CABIN FLOORBEAM -1292 IS CORRODED BETWEEN FR 16 ANDFR 20. BLENDED OUT CORRODED AREA IAW SRM 51-74-00, L=3.0" W=1.0 D=0.070" ORIGINAL MATERIAL THICKNESS 0.079", FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14, FIG 105. REMOVED FLOORBEAM IAW SRM 51-42-11, INSTSDR DALA1108533243Light · missingDURING EMERGENCY LIGHT TEST FOUND PATH LIGHT AT ROW 22 MODULE MISSING, NEW MODULE INSTALLED AND TESTS OK. (2011-00083)SDR DALA1108963235Seat Track · corrodedCORROSION AT SEAT TRACK FLANGE, RBL "60" INBD OF FRAME 20 RT CORROSION REMOVED & CONTAINED, CUTOUT DAMAGE, FABRICATED,REPAIR ANGLE FROM .080 7075-0 HEAT TREATED. DRILLED, TRIMMED & DEBURRED. TREATED & PRIMED & INSTALLED IAW 53-11-15. REQUIRED INSP COMPLETE.SDR DALA1104903242Floor Panel · damagedAFT CARGO COMPARTMENT FLOOR PANEL 151EF HAS DAMAGE ON UPPER SURFACE. REMOVED, FABRICATED & INSTALLED NEW PANEL IAW AMM 53-42-14-400-001 AND AMM 53-42-14-420-050-A.SDR DALA1104423242Floor Panel · damagedFWD CARGO COMPARTMENT, FLOOR PANEL 131AF HAS DAMAGE. REMOVED FWD CARGO COMPARTMENT FLOOR PANEL 131AF IAW AMM 53-22-14 PB401. REPLACED PANEL IAW AMM 53-22-14 PB401. FABRICATED PANEL ON STAM TRAVELER IAW DWG 3D25-37705. RETAIN FOR RECORDS.SDR DALA1103513235Connector · brokenDURING EMERGENCY LIGHT TEST FOUND ROW 5C PATH LIGHT INOPERATIVE, REPLACED BROKEN CONNECTOR AND TESTS OK.SDR DALA1103573269Power Supply · inoperativeDURING NON A ROUTINE CHECK, FOUND THE EMERGENCY LIGHT AT L2 DOOR INOPERATIVE. MX REPLACED THE POWER SUPPLY AND LIGHT ASSY. FUNCTIONAL CHECK WAS NORMAL AND ACFT WAS RETURNED TO SERVICE.SDR DALA1103103250Wire · damagedDURING EMERGENCY LIGHT TEST SEAT ROW 16ABC WAS FOUND INOP, REPAIRED WIRE CONNECTION AND TESTS OK.SDR DALA1102293250Wire · damagedDURING EMERGENCY LIGHT TEST FOUND PATH LIGHTS AT SEAT ROW 5ABC AND BOTH AT ROW 10ABC INOPERATIVE. BULB AND LENS WERE REPLACED AND THE WIRE WAS REPAIRED. ALL TESTS OK.SDR DALA1102393257Wire · brokenDURING A NON ROUTINE CHECK, MX FOUND SEAT ROW 6C EMERGENCY PATH LIGHT INOPERATIVE. REPAIRED A BROKEN WIRE UNDER SEAT AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1100573257Power Supply · faultedDURING NON-ROUTINE CHECK, FOUND THE EMERGENCY POWER SUPPLY UNIT FAULTED AT 10WL. MX REPLACED POWER SUPPLY UNIT AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1053163258Connector · disconnectedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT ROW 11L INOPERATIVE. MX RECONNECTED HARNESS TO CONNECTOR AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1053133258Connector · unsecureDURING A NON ROUTINE, THE EMERGENCY LIGHT INTEROR LOAD TEST OF EPSU FAULTS THE FWD LT. MX RESEATED THE CONNECTOR PLUG AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1051913259Battery Pack · inoperativeDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY LIGHT AT 10WL INOPERATIVE. MX REPLACED THE BATTERY PACK AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURN TO SERVICE.SDR DALA1051893269Connector · unsecureDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT 5C AND 8C INOPERATIVE. MX RESECURED WIRING CONNECTORS AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED SERVICE.SDR DALA1050753250Connector · unsecureDURING EMERGENCY LIGHT TEST EPSU FWD LT SHOWED LOAD FAULT, SECURED CONNECTOR AND TEST OK.SDR DALA1035013252Bottle · emptyDURING LINE CHECK FOUND DOOR 1R, DOOR ASSIST BOTTLE IS DEPRESSURIZED FRANGIBLE DISK IS RUPTURED. R & R 1R DOOR DAMPER EMERGENCY OPERATING CYLINDER IAW AMM 52-11-14.SDR DALA1034623241Floorboard · damagedDURING LINE CHECK FOUND AFT CARGO FLOORBOARD 151GF DAMAGED. R & R AFT CARGO FLOORBOARD 151GF IAW MM. OK FOR SERVICE.SDR DALA1034643270Wire · damagedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT ROW 1 INOPERATIVE. REPAIRED PULLED WIRE AT CONNECTOR UNDER SEAT AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1034633266Hinge Fitting · chafedDURING M-CHECK FOUND CHAFE DAMAGE ON RT & LT MLG FWD DOOR HINGE FITTINGS, FWD LUG, FWD FACE. IAW ERA 482533-14AD, FOLLOW UP INSP IS REQUIRED ON THE LT & RT MLG DOOR FWD HINGE FITTING. ACCOMPLISH SECTION II INSP NTE 3500 CYCLE INTERVALS FROM 03JUN10.SDR DALA1032403250Wire · damagedDURING EMERGENCY LIGHT TEST, SEAT 9C PATH LIGHT WAS INOP. REPAIRED WIRING AND CHECKED OK. (2010-00855)SDR DALA1031003254Door · damagedDURING GROUND OPERATIONS THE L2 DOOR WAS DAMAGED IN THE LOWER AFT CORNER. REMOVED AND REPLACED DOOR PER MM 52-13-11.SDR DALA1030043240Wire · disconnectedDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY PATH LIGHT AT SEAT 7C AND 25C INOPERATIVE. MAINTENANCE RECONNECTED WIRES AT BOTH SEAT AND FUNCTIONAL CHECK WAS NORMAL. (2010-00829)SDR DALA1029073241Seat Track · corrodedDURING L-CHECK FOUND CORROSION ON SEAT TRACK AT BS Y254 BETWEEN FR 18 - FR 20. REPAIRED PER SRM 51-42-11, SRM 51-74-00 & 53-11-15.SDR DALA1029063241Floorbeam · crackedFWD CABIN FLOORBEAM +Y254 BET FR 24 AND FR 25 CRACKED. TRIMMED OUT CRACKED AREA DIM: W=1" X L=3.470" IAW SRM 53-00-14 FIG 204. FABRICATED DOUBLER FROM 7075T6.063 BATCH 1502238. FABRICATED FILLER REPAIR FROM 7075T6.063 BATCH 1766127 IAW SRM 53-00-14 FIG 204.SDR DALA1028603241Panel · damagedDURING L-CHECK FOUND DAMAGE TO CARGO PANEL 131AF. REPLACED PER SRM 53-02-00 FIGURE 205.SDR DALA1028593241Floor Support · corrodedDURING L-CHECK FOUND CORROSION ON FLOOR SUPPORT AT Y765 FR 18- FR 21. REPAIRED PER SRM 51-42-11 & SRM 51-44-11.SDR DALA1027963241Strap · corrodedDURING L CHECK FOUND CORROSION ON FLOORBOARD STRAP AT BETWEEN Y254 & Y254 FR 20. REPAIRED PER SRM 51-42-11, SRM 53-11-27 FIGURE 16, SRM 51-21-10 & SRM 51-75-12.
Back to Airbus A320-212