SDR DALA1026273235Wire · damagedDURING NON ROUTINE CHECK, FOUND EMERGENCY PATH LIGHT AT SEAT ROW 22L AND 25L INOPERATIVE. MX REPLACED BLACK WIRE AT JIFFY AND PERFORMED SUCCESSFUL TEST. ACFT RETURNED TO SERVICE.SDR DALA1025613245Power Supply · inoperativeDURING A NON ROUTINE CHECK, MX FOUND THE EMERGENCY PATH LIGHT AT ROW 1, 2, 3, 6, 7, AND 8 INOPERATIVE. REPLACED POWER SUPPLY UNIT AND OPERATIONAL TEST WAS NORMAL.SDR DALA1025153265Wire · damagedDURING A NON ROUTINE CHECK, MAINT FOUND ROW 10 ABC EMERGENCY PATH LIGHT INOPERATIVE. MAINT SPLICED IN NEW WIRES UNDER SEAT AND PERFORMED FUNCTIONAL CHECK. CHECK WAS NORMAL.SDR DALA1024493268Skin · damagedDURING LINE CHECK FOUND DAMAGE TO AFT CORNER OF AFT CARGO DOOR SKIN. REPAIRED IAW SRM 52-52-30-00.SDR DALA1516483264Skin · damagedFUSELAGE SKIN BETWEEN FRAMES 66-68, MISDRILLED HOLES BELOW R2 DOOR. REPAIRED IAW ERA 480602-14.SDR DALA1023613238Hose · leakingFLIGHT CREW NOTED A SUBSTANTIAL DIFFERENCE IN FUEL FLOW/FUEL USED BETWEEN ENGINE NR 1 AND NR 2. FLIGHT CREW LANDED ACFT AT DESTINATION AND ENGINE NR2 AUTO SHUTDOWN AS ACFT TURNED OFF OF THE RUNWAY. MX FOUND A FUEL LEAK AT THE MAIN FUEL SUPPLY LINE TO FUEL FILSDR DALA1023393244Wire · damagedDURING A NON ROUTINE CHECK, FOUND THE SEAT ESCAPE PATH EMERGENCY LIGHT AT ROW 22 INOPERATIVE. MX SPLICED A PULLED APART WIRE TOGETHER AND OPS CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA2014121606552Skin · dentedDENT ON L2 DOOR SKIN. CUTOUT THE DAMAGED AREA IAW SRM 52-10-00, FIG 209, SHEET 3. FABRICATED A REPAIR DOUBLER IAW SRM 52-10-00, FIG 209 SRM 51-44-11 AND SRM 52-10-00 FIG 209. INSTALLED THE REPAIR IAW SRM 52-10-00, FIG 209 AND SRM 51-42-11.SDR DALA1022483250Battery Pack · inoperativeDURING A NON ROUTINE CHECK, FOUND THE RT OVERWING EMERGENCY LIGHT TO BE INOPERATIVE. MX REPLACED EPSU AND BATTERY PACK. FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1022023269Connector · disconnectedPILOT REPORTED EMERGENCY PATH LIGHT AT SEAT 5C INOP, SECURED CONNECTOR AND CHECKS OK.SDR DALA1022033259Connector · looseEMERGENCY LIGHT TEST FAILED EPSU AFT LT, CONNECTOR RESEATED AND TESTS OK.SDR DALA1021193274Floor Panel · damagedDURING LINE CHECK FOUND FWD CARGO FLOOR PANEL 131EF WITH SEVERAL SCREWS PULLED THROUGH. REPLACED FLOOR PANEL IAW SRM 53-22-14, PAGE 401.SDR DALA1021183274Floor Panel · damagedDURING LINE CHECK FOUND FWD CARGO FLOOR PANEL 131AF WITH SEVERAL SCREWS PULLED THROUGH. REPLACED FLOOR PANEL IAW SRM 53-22-14 PAGE 401.SDR DALA1020673234Wire · brokenDURING OVERNIGHT CHECK, FOUND EMERGENCY LIGHT SEAT ROW 19 INOP, REPAIRED BROKEN WIRE AND TESTS OK.SDR DALA1020653263Connector · looseF/A REPORTED BOTH EMERGENCY ESCAPE PATH LIGHTS ROW NR 1 WERE INOP, FOUND CONNECTOR LOOSE AND SECURED AND TESTS OK.SDR DALA1020553263Light · missingREPORTED BY CREW OFF FLIGHT 1568 SEAT 5ABC EMERGENCY PATH LIGHT MISSING, REPLACED LIGHT AND TESTED OK.SDR DALA1019833236Light · inoperativeDURING A NON ROUTINE CHECK, FOUND THE EMERGENCY ESCAPE LIGHT AT SEAT ROW 10L, 11L AND 12L INOPERATIVE. REPLACED EPSU AND BATTERY PACK. PERFORMED FUNCTIONAL CHECK AND CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1019813245Battery Pack · inoperativeDURING A NON ROUTINE CHECK, FOUND ROW 3 FIRST CLASS AND ROW 3 COACH CLASS PATH LIGHT INOPERATIVE. MX REPLACED BATTERY PACK AND FUNCTIONAL CHECK WAS NORMAL. ACFT RETURNED TO SERVICE.SDR DALA1019523270Support · gougedDURING M-CHECK, WHILE PERFORMING LT INBD FLAP AND TRUNNION INSP, FOUND GOUGE DAMAGE ON LT INBD FLAP TRUNNION SUPPORT ASSY. REPLACED TRUNNION SUPPORT ASSY IAW SRM 57-51-21 & ERA 484244-14.SDR DALA1019363270Mount · gougedDURING M-CHECK, FOUND NR 2 AFT PYLON ENGINE MOUNT INBD AFT SIDE GOUGED ADJACENT TO BOLT LOCK WIRE HOLE. REPAIRED SECTION I LIMITED TO SIX MONTHS. SECTION II CALLS FINAL REPAIR APPROVAL WITHIN 6 MONTHS OR 182 DAYS FROM 12 AUG 2010.SDR DALA1019353270Sill · corrodedDURING M-CHECK, FOUND CORROSION ON RT DOOR SILL BETWEEN FR66 & FR68. REPAIRED IAW SRM 51-42-11, SRM 53-41-14, ERA 484229-14.SDR DALA1019343270Structure · corrodedDURING M-CHECK, FOUND CORROSION ON STRINGER COUPLINGS BETWEEN S41L TO S43L FROM FRAME 30 TO FRAME 31. REPAIRED IAW SRM 51-42-11, SRM 51-44-11, SRM 51-75-12 AND DWG 53231516.SDR DALA1019213270Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM AT +Y254 BETWEEN FR 16 & FR 21. REPAIRED IAW SRM 51-44-11, SRM 51-42-11, ERA 484240-14.SDR DALA1019023236Skin · corrodedDURING L-CHECK, FOUND CORROSION ON FUSELAGE SKIN BETWEEN FR 69 & FR 70 ABOVE STINGER 34R. REPAIRED IAW SRM 53-41-11, SRM 51-44-11, SRM 51-52-11, FIG 205.SDR DALA1018983236Skin · gougedDURING "L" CHECK FOUND GOUGE ON FUSELAGE SKIN BETWEEN FR24 & FR25, STRINGER 42L & STRINGER 43L. REPAIRED IAW SRM 53-21-11, SRM 51-42-11.SDR DALA12004243236Skin · damagedDURING INSPECTIONS, FOUND LIGHTNING STRIKE AT FR60 BET STR 22L AND 23L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11. COMPLIED WITH NDT INSPECTION PER NTM 51-10-01, NO CRACKS FOUND. INSTALLED FASTENER PER SRM 53-41-11.SDR DALA1018553270Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT BEAM AT Y1732 BETWEEN FR 65 & FR 66. REPAIRED PER SRM 51-44-11, SRM 51-42-11.SDR DALA12004233236Skin · damagedDURING INSPECTIONS, FOUND LIGHTNING STRIKE AT FR 55 BET STR 22L AND 23L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11. COMPLIED WITH NDT INSPECTION PER NTM 51-10-01, NO CRACKS FOUND. INSTALLED FASTENER PER SRM 53-41-11.SDR DALA12004223236Skin · damagedDURING INSPECTIONS, FOUND LIGHTNING STRIKE AT FR50 BET STR 20L AND 21L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11. PERFORMED INSPECTION NTM 51-10-01, NO CRACKS FOUND. REPLACED FASTENER PER SRM 53-41-11.SDR DALA12004213236Skin · damagedDURING INSPECTIONS, FOUND LIGHTNING STRIKE BET FR48 & 49 AT STR 21L BOTH RIVET AND ADJACENT SKIN. REMOVED FASTENER IAW SRM 51-42-11/53-00-11. HFEC IAW NTM 51-10-08, NO DEFECTS. REMOVED PAINT, NO DAMAGE FOUND ON SKIN IAW SRM 51-75-11. TREATED AND PRIMED ARESDR DALA12004203236Skin · damagedDURING INSPECTIONS, FOUND LIGHTNING STRIKE AT 5TH RIVET FWD OF FR 69, STR 21L BOTH RIVET AND ADJACENT SKIN. REMOVED FASTENER PER SRM 53-41-11. PERFORMED BHEC PER NTM 51-10-11, NO CRACKS FOUND. REPLACED FASTENER PER SRM 53-41-11.SDR DALA12004293236Skin · damagedDURING INSPECTION, FOUND LIGHTNING STRIKE BET FR 51 AND 52 AT STR 22L BOTH RIVET AND ADJACENT SKIN. REMOVE BLIND FASTENER PER SRM 53-41-11. COMPLIED WITH NDT INSPECTION PER NTM 51-10-01. NO CRACKS FOUND. INSTALLED FASTENER PER SRM 53-41-11.SDR DALA12004283236Skin · damagedDURING INSPECTION, FOUND LIGHTNING STRIKE AT FR 52 BET STR 21L AND 22L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11. PERFORMED HOLE INSPECTION, NO CRACKS FOUND PER NTM 51-10-01. INSTALLED FASTENER PER SRM 53-41-11.SDR DALA12004273236Skin · damagedDURING INSPECTION, FOUND LIGHTNING STRIKE AT FR53 STR 22L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11. C/W NDT INSPECTION PER NTM 51-10-01 NO ITEMS. INSTALLED FASTENER PER SRM 53-41-11.SDR DALA12004263236Skin · damagedDURING INSPECTIONS, FOUND LIGHTNING STRIKE BET FR52 AND 53 AT STR 22L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11. PERFORMED HOLE INSPECTION, NO CRACKS FOUND PER NTM 51-10-01. REPLACED FASTENER PER SRM 53-41-11.SDR DALA12004253236Skin · damagedDURING INSPECTIONS, FOUND LIGHTNING STRIKE AT FR48 BET STR 22L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11. PERFORMED HOLE INSPECTION, NO CRACKS FOUND PER NTM 51-10-01. REPLACED FASTENER PER SRM 53-41-11.SDR DALA12004303236Skin · damagedDURING INSPECTION, FOUND LIGHTNING STRIKE AT FR 54 BET STR 22L AND 23L BOTH RIVET AND ADJACENT SKIN. REMOVED BLIND FASTENER PER SRM 53-41-11 (ID201079). PERFORMED HOLE INSPECTION, NO CRACKS FOUND PER NTM 51-10-01. INSTALLED FASTENER PER SRM 53-41-11.SDR DALA1018393270Support · crackedDURING M-CHECK FOUND CRACK IN COCKPIT FLOORBEAM SUPPORT WEB BETWEEN FR8 & FR11. REPAIRED PER SRM 51-44-11, SRM 51-42-11.SDR DALA1018473270Floor Panel · delaminatedDURING M-CHECK FOUND FLOOR PANEL 151GF DELAMINATED. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1018463270Floor Panel · delaminatedDURING M-CHECK FOUND FLOOR PANEL 131AF DELAMINATED. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1018453270Floor Panel · delaminatedDURING M-CHECK FOUND FLOOR PANEL 151DF DELAMINATED. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1018443270Floor Panel · delaminatedDURING M-CHECK FOUND FLOOR PANEL 151AF DELAMINATED. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1018433270Floor Panel · damagedDURING M-CHECK FOUND CARGO FLOOR PANEL 151LF MISSING UPPER SKIN. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1018423270Floor Panel · delaminatedDURING M-CHECK FOUND FLOOR PANEL 161AF DELAMINATED. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1018413270Floor Panel · delaminatedDURING M-CHECK FOUND FLOOR PANEL 131EF DELAMINATED. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1018373270Frame · corrodedDURING M-CHECK FOUND CORROSION ON FRAME AT FR 20 STRINGER 23R. REPAIRED PER SRM 51-23-11, SRM 51-21-00, ERA484233-14.SDR DALA1018403270Floor Panel · delaminatedDURING M-CHECK FOUND FLOOR PANEL 232DF DELAMINATED. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D2537498.SDR DALA1018383270Floor Panel · delaminatedDURING M-CHECK FOUND FLOOR PANEL 261PF DELAMINATED. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D2537498.SDR DALA1018233270Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT Y765 BETWEEN FR18 & FR20. REPAIRED PER SRM 51-42-11.SDR DALA1018223270Support · crackedDURING M-CHECK FOUND CRACK IN FLOORBEAM SUPPORT WEB BETWEEN FR8 TO FR11. REPAIRED PER SRM 51-42-11.
Back to Airbus A320-212