Airbus A320-212
Service difficulty reports · 8,184
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320212' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1018173249Battery Pack · dischargedDURING A NON ROUTINE CHECK, FOUND LEFT AFT EMERGENCY LIGHT INOPERATIVE. REPLACED AFT LEFT EPSU BATTERY PACK AND PERFORMED FUNCTIONAL CHECK. CHECK WAS NORMAL AND AIRCRAFT RETURNED TO SERVICE.SDR DALA1018073270Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM SUPPORT AT Y1292 BETWEEN FR67 AND FR 68. REPAIRED PER SRM 51-42-11, SRM 51-44-11.SDR DALA1018063270Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM SUPPORT AT +Y765 BETWEEN FR66 & FR70. REPAIRED PER SRM 51-42-11, SRM 51-44-11.SDR DALA1018053270Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM SUPPORT AT Y1292 BETWEEN FR68 & FR69. REPAIRED PER SRM 51-42-11, SRM 51-44-11.SDR DALA1018043270Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM SUPPORT AT Y765 BETWEEN FR66 & FR70. REPAIRED PER SRM 51-42-11, 51-44-11.SDR DALA1018033270Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM SUPPORT AT Y765 BETWEEN FR64 & FR66. REPAIRED PER SRM 51-42-11, SRM 51-44-11.SDR DALA1018023270Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT Y765 BETWEEN FR18 & FR20. REPAIRED PER SRM 51-42-11.SDR DALA1018013270Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT FOR FLOOR PANEL 232FF AT FR20. REPAIRED PER SRM 51-42-11, SRM 51-44-11.SDR DALA1018003270Structure · corrodedDURING M-CHECK FOUND CORROSION ON CABIN FLOOR STRUCTURE AT S23L & S24L BETWEEN FR69 & FR70. REPAIRED PER SRM 51-42-11, SRM 51-44-11.SDR DALA1017993270Fitting · corrodedDURING M-CHECK FOUND CORROSION ON R1 DOOR SILL SHAPER FITTING. REPLACED PER SRM 51-42-11.SDR DALA1017983270Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM SUPPORT AT +Y1292 BETWEEN FR68 & FR69. REPAIRED PER SRM 51-44-11, SRM 51-42-11.SDR DALA1017973270Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM SUPPORT AT +Y1292 BETWEEN FR64 & FR66. REPAIRED PER SRM 51-44-11, SRM 51-42-11.SDR DALA1017963270Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM SUPPORT AT +Y1292 BETWEEN FR66 & FR68. REPAIRED PER SRM 51-44-11, SRM 51-42-11.SDR DALA1017953270Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM SUPPORT AT Y254 BETWEEN FR66 & FR68. REPAIRED PER SRM 51-44-11, SRM 51-42-11.SDR DALA1017943270Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT & SPLICE ANGLE AT +Y254 BETWEEN FR66 & FR68. REPAIRED PER SRM 51-44-11, SRM 51-42-11.SDR DALA1017933270Shear Web · corrodedDURING M-CHECK FOUND CORROSION ON FLOOR SUPPORT SHEAR WEB AT +Y1292 BETWEEN FR68 & FR 69. REPAIRED PER SRM 51-44-11, SRM 51-42-11.SDR DALA1017923270Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT Y1292 BETWEEN FR20 & FR23. REPAIRED PER SRM 51-44-11, SRM 51-42-11.SDR DALA1017913270Support · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM SUPPORT AT +Y465 BETWEEN FR64 & FR67. REPAIRED PER SRM 51-42-11, SRM 51-44-11.SDR DALA1017753270Floorbeam · corrodedDURING M-CHECK FOUND CORROSION ON FLOORBEAM AT Y254, FR20. REPAIRED IAW SRM 53-11-14 FIGURE 203, SRM 51-42-11.SDR DALA1017743270Sill · corrodedDURING M-CHECK FOUND CORROSION ON R2 DOOR SILL AT FR68. REPAIRED IAW SRM 53-41-14, SRM 51-44-11.SDR DALA1017733270Sill · corrodedDURING M-CHECK FOUND CORROSION ON L2 DOOR SILL AT FR68. REPAIRED IAW SRM 51-42-11, SRM 51-44-14.SDR DALA1017673270Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON FORWARD UTILITY RAIL AT +Y503 AT FR16. REPAIRED PER SRM 51-42-11.SDR DALA1017663270Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT Y765 BETWEEN FR18 & FR 20. REPAIRED PER SRM 53-11-14, SRM 53-44-11. SUPPLEMENTAL RECORD, REFERENCE CONTROL NUMBER DALA1017653270 2ND ENTRY.SDR DALA1017653270Floor Support · corrodedDURING M-CHECK FOUND CORROSION ON AFT CABIN FLOOR SHEAR PLATE SUPPORT BETWEEN FR69-FR70 AT S23R. REPAIRED PER SRM 51-42-11, SRM 51-44-11.SDR DALA1017573261Power Supply · inoperativeTHE RIGHT EMERGENCY EXIT LIGHT FAILED TEST DURING A NON ROUTINE CHECK. MAINTENANCE REPLACED EPSU AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1017623270Floor Panel · damagedDURING M-CHECK FOUND CORROSION AND DELAMINATION ON FLOOR PANEL 221FF. REPLACED FLOOR PANEL PER SRM 51-72-00.SDR DALA1017613269Skin · dentedDURING M-CHECK FOUND RIGHT FUSELAGE SKIN DENTED AT FR3. REPAIRED PER ERA 483384-14 & SRM 51-42-11.SDR DALA1017593269Support · corrodedDURING M-CHECK FOUND CORROSION ON AFT CABIN RT FRAME SUPPORT BETWEEN FR69 & FR70. REPAIRED PER SRM 51-42-11 & SRM 51-44-11.SDR DALA1017583269Sill · corrodedDURING M-CHECK FOUND CORROSION ON R2 DOOR SILL AT FR 66. REPAIRED PER ERA 483379-14.SDR DALA1017603269Fitting · corrodedDURING M-CHECK FOUND CLEAT CORRODED AT FR33 BETWEEN S41L & S42L. REPAIRED PER SRM 51-42-11 & SRM 51-44-11.SDR DALA1017173269Support · corrodedDURING M-CHECK FOUND CORROSION ON AFT CABIN LT FRAME SUPPORT AT +Y1732 BETWEEN FR69 & FR70. REPAIRED PER SRM 51-42-11.SDR DALA1016993269Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 131AF. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1016983269Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 131EF. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1016973269Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 131HF. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1016963269Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 151GF. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1016953269Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 151AF. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1016943269Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 151DF. REPLACED FLOOR PANEL PER DWG 3D25-37705.SDR DALA1016263269Floor Panel · damagedDURING M-CHECK FOUND DAMAGE TO FLOOR PANEL 261PF. FABRICATED AND REPLACED FLOOR PANEL PER DWG 3D25-37498.SDR DALA1016243269Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT +Y1292 BETWEEN FR68 & FR69. REPAIRED PER SRM 51-42-11.SDR DALA1016233269Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT +Y1292 BETWEEN FR66 & FR68. REPAIRED PER SRM 51-42-11.SDR DALA1016603243Light · inoperativeDURING TEST FOUND EXIT LIGHT AT SEAT 24C INOP. REPLACED LIGHT ASSEMBLY AND TESTS OK.SDR DALA1016183249Socket · defectiveDURING A NON ROUTINE CHECK, FOUND EMERGENCY LIGHT AT SEAT 24 C INOPERATIVE. REPLACED LIGHT SOCKET AND PERFORMED SUCCESSFUL TEST. A/C RETURNED TO SERVICE.SDR DALA1016163260Battery · failedDURING A NON ROUTINE CHECK, FOUND THE RIGHT EMERGENCY LIGHTS FAULTING TEST. REPLACED THE BATTERY AND PERFORMED SUCCESSFUL TEST. A/C RETURNED TO SERVICE.SDR DALA1016143259Connector · looseDURING A NON ROUTINE CHECK, MAINTENANCE FOUND SEAT ROW 23 EMERGENCY PATH LIGHT INOPERATIVE. RE-SECURED A LOOSE CONNECTOR AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1016133244Wire · brokenDURING A NON ROUTINE CHECK, FOUND SEAT 23 EMERGENCY PATH LIGHT INOPERATIVE. MAINTENANCE REPAIRED A BROKEN WIRE AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1015883269Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT Y765 BETWEEN FR64 & FR66. REPAIRED PER SRM 51-44-11, SRM 51-42-11.SDR DALA1015873221Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT Y765 BETWEEN FR66 & FR70. REPAIRED PER SRM 51-42-11, SRM 51-44-11.SDR DALA1015943261Light · inoperativeDURING A NON ROUTINE CHECK, MAINTENANCE FOUND SEAT 4B EMERGENCY PATH LIGHT INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1015933261Light · inoperativeDURING A NON ROUTINE CHECK, MAINTENANCE FOUND SEAT 23C EMERGENCY PATH LIGHT INOPERATIVE. MAINTENANCE REPLACED LIGHT ASSEMBLY AND FUNCTIONAL CHECK WAS NORMAL. AIRCRAFT RETURNED TO SERVICE.SDR DALA1015683269Seat Track · corrodedDURING M-CHECK FOUND CORROSION ON SEAT TRACK AT Y1292 BETWEEN FR66 & FR68. REPAIRED PER SRM 51-42-11 & SRM 51-44-11.
Back to Airbus A320-212