Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA2020080300410Hinge · brokenDURING HEAVY MAINTENANCE, BROKEN HINGE ARM 4 ELEVATOR TAB ON RH HORIZONTAL STAB; (REF ARM W/O 2020-230/1 N/R 2020-211634) REPAIRED TAB IAW SRM A320 55-26-41-300-002 FIG 001. THIS REPAIR IS CONSIDERED CAT A, AND NO FURTHER INSPECTION REQUIRED.SDR YENA2020080300409Beam · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION ON BEAM FRAME 43 (2 EACH) IN AFT FASTENER HOLE AND MIDDLE HOLE SIDE BOX BEAM AREA LH SIDE; (REF ARM W/O 2020-230/1 N/R 2020-211471) PERFORMED PERMANENT REPAIR ON BEAM FR 43 LH SIDE IAW EC A320-1251.SDR YENA2020080300408Beam · crackedDURING HEAVY MAINTENANCE, CRACK INDICATION ON BEAM FRAME 43RH SIDE (2EACH) IN AFT FASTENER HOLE AND MIDDLE HOLE SIDE BOX BEAM AREA; (REF ARM W/O 2020-230/1 N/R 2020-211473) PERFORMED PERMANENT REPAIR ON BEAM FR 43 RH SIDE IAW EC A320-1251.SDR GTIA2020072735283Flashlight · inoperativeFLIGHT ATTENDANT "C" FLASHLIGHT INOP ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) )-REMOVED AND REPLACED F/A SEAT C FLASHLIGHT IAW EMERGENCY EQUIPMENT LAYOUT DRAWING EQ.SDR GTIA2020072735282Bottle · low pressureL2 DOOR ASSIT BOTTLE PRESS LOW -SERVICED L2 DOOR IAW AMM 52-10-00SDR YENA2020073000405Servo Control · failedFLT 1485, AIRFRAME VIBRATION IN FLIGHT, R & R THE RIGHT INBOARD SERVO CONTROL FOR THE ELEVATOR IAW AMM 27-34-51.SDR YENA2020073000404Servo Control · failedFLT 1485, AIRFRAME VIBRATION IN FLIGHT. R & R THE RIGHT INBOARD SERVO CONTROL FOR THE ELEVATOR IAW AMM 27-34-51.SDR AALA202007279005Lamp · inoperativeAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT LIGHT OVER R1 DOOR INOPERATIVE. RELAMPED EXIT LIGHT OVER R1 DOOR PERFORMED OPS CHECK PER AMM 33-51-00.SDR AALA202007279004Lamp · inoperativeAIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT LIGHT OVER L1 DOOR INOPERATIVE. RELAMPED EXIT LIGHT OVER L1 DOOR PER AMM 33-51-00SDR GTIA2020072735277A/C Pack · odorFUME EVENT DURING CRUISE OIL AND EXAUST SMELL ISOL PACK 1 OFF-ACCOMPLISHED TSM 05-50-00-810-831 FOR CABIN ODOR RAN PACK 1 ON APU BLEED ISOLATED PACKS NO SIGN OF CONTAMINATION RAN ENG 1 BLEED NO SIGN OF CONTAM INSPECTED PACKS AND APU AREAS NO SIGN OF POSSIBLE CSDR GTIA2020072735275A/C Pack · contaminatedDURING DESCENT AT 8000 FT, FUMES ODOR BOTH PACKS AND BLEEDS ON. REF TSM 05-50-00-810-831 RAN BOTH PACKS ON ENG'S & APU BLEED IAW AMM 71-00-00 AND AMM 49-00-00. ISLOATED TO NR 1 PACK CONTAMINATION. NO OIL LEAKS FOUND.SDR GTIA2020072735274Bottle · low pressureL1 DOOR ASSIT REQUIRES SERVICE-SERVICED L1 DOOR IAW AMM 52-10-00SDR YENA2020072700403Blower · failedFLT 739, EMERGENCY DECLARED. LOUD NOISE AND VIBRATION UNDER OUR FEET ON BOTH SIDES WHEN SMOKE AND FUMES INITIATED BLOWER MOTOT, SWITCHED OFF, VIBRATION STOPPED AND FUMES DISSIPATED AFTER A FEW MINUTES . AT TOP OF DESCENT FUMES CAME BACK OXYGEN MASKS DONNED AGSDR AALA202007249005Accumulator · low pressureAIRCRAFT WAS NOT GROUNDED: CABIN R1 DOOR NEEDS TO BE SERVICED. FILLED CABIN R1 DOOR ACCUMULATOR WITH NITROGEN IAW AMM 52-10-00. OK FOR SERVICESDR YENA2020072700402Battery · failedFLT 6250,REF TASK CARD 335100-03-1 (BATTERY CAPACITY); R & R FWD ESPU BATTERY PER AMM 33-51-00. OPS CHK.SDR YENA2020072700401Battery · failedFT # 6250, MZJ-JFK. REF TASK CARD 335100-03-01 (BATTERY CAPACITY CH); R & R AFT ESPU BATTERY PER AMM 33-51-00. OPS CHK OKSDR YENA2020072700400Power Supply · failedFLT 6250, AFTER REPLACEMENT OF L2 DOOR SLIDE EMERGENCY LIGHT, OPERATIONAL CHECK FAILED. R & R LT & RT ESPU BATTERIES IAW AMM 33-51-00. OPS TESTED OK. R & R R ESPU IAW AMM 33-51-11. OPS CHECKED OK.SDR YENA2020072700399Battery · failedFLT 6250, AFTER REPLACEMENT OF L2 DOOR SLIDE EMERGENCY LIGHT, OPERATIONAL CHECK FAILED. R & R L & R ESPU BATTERIES IAW AMM 33-51-00. OPS TEST OK. R & R R ESPU IAW AMM 33-51-11. OPS CHECKED OK.SDR YENA2020072700398Battery · failedFLT 6250, AFTER REPLACEMENT OF L2 DOOR SLIDE EMERGENCY LIGHT, OPERATIONAL CHECK FAILED. R & R THE LT & RT ESPU BATTERIES IAW AMM 33-51-00. OPS TEST OK. R & R R ESPU IAW AMM 33-51-11. OPS CHECKED OK.SDR AALA2020072439002Intercostal · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION IN INTERCOSTAL AT UPPER INBD HOLE OF DOOR STOP #7 ATTACHMENT, MEASURING L=0.080 IN. REPLACED INTERCOSTAL WITH MODIFIED PART IAW SRM 51-72-11 AND EA 307247.SDR AALA2020072329010Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION AT UPPER IB HOLE IN INTERCOSTAL FITTING AT DOOR STOP #7 ATTACHMENT, FR16 BETWEEN STR10R AND STR11R, MEASURING 0.080 IN. REMOVED AND REPLACED FITTING WITH MODIFIED PART IAW SRM 51-72-11, EA 307245, AND DRAWING D531SDR AALA2020072319013Flap · crackedAIRCRAFT IN BASE MAINTENANCE, RIGHT WING OUTBOARD FLAP FOUND CRACKED. REMOVED AND REPLACED RIGHT WING OUTBOARD FLAP IAW AMM 27-54-62. ADJUSTED FORWARD ECCENTRIC BEARING, OKAY. CHECKED SPOILER DIMENSION IAW AMM 27-64-00-820-001-C, WITHIN LIMITS. PERFORMED SDR AALA2020072219014Engine · slowAIRCRAFT WAS NOT GROUNDED, REJECTED TAKEOFF FOR SLOW LEFT ENGINE ACCELERATION BETWEEN 1.05 EPR AND FLEX POWER SETTING. IT WAS PROBABLY DUE TO HIGH AIRPORT ELEVATION. REJECTED WELL BELOW 80KTS. PERFORMED NR 1 ENG HIGH POWER ASSURANCE TEST IAW JOB CARD 26L0007SDR YENA2020072200396Valve · failedFLT 2137, AFTER TAKEOFF ECAM NR 1 AIR BLEED FAULT. RETURNED TO FIELD. EMERGENCY DECLARED. R & R BOTH HP VALVE & PRESSURE REGULATING VALVE. PERFORMED A BLEED HEALTH MONITERING CHECK IAW MCC REQUEST. OPS CHECKED GOOD IAW AMM 36-11-00.SDR YENA2020072200395Valve · failedFLT 2137, AFTER TAKEOFF, ECAM NR 1 AIR BLEED FAULT. RETURNED TO FIELD. EMERGENCY DECLARED. R & R BOTH THE HP VALVE, & PRESSURE REGULATING VALVE. PERFORMED BLEED HEALTH MONITERING CHECK IAW MCC REQUEST, OPS CHECKED GOOD IAW AMM 36-11-00.SDR YENA2020072200394Valve · failedFLT 2137, AFTER TAKEOFF, ECAM NR 1 AIR BLEED FAULT. RETURNED TO FIELD. EMERGENCY DECLARED. R & R BOTH THE HP VALVE & PRESSURE REGULATING VALVE. PERFORMED BLEED HEALTH MONITERING CHECK IAW MCC REQUEST. OPS CHECKED GOOD IAW AMM 36-11-00.SDR AALA202007219008Window · crackedAIRCRAFT NOT GROUNDED - FIRST OFFICER'S R3 WINDOW CRACKED. REMOVED AND REPLACED R3 (FIXED) WINDOW PER AMM 56-11-12.SDR AALA202007209002Feeder Cable · wornAIRCRAFT IN BASE MAINTENANCE, RT PYLON, WORN WIRES, IDG FEEDER CABLE, UNDER ACCESS PANEL 424ER. REPAIRED THE IDG FEEDER CABLE WIRES IAW ESPM 20-53-21.SDR AALA202007209005Bolt · no testAIRCRAFT IN BASE MAINTENANCE, NR 2 ENGINE FORWARD MOUNT BOLTS FAILED TORQUE CHECK. REPLACED FIVE MOUNT BOLTS AND NUTS IAW AMM 71-21-12-400-010.SDR YENA2020072200393Proximity Switch · failedFLT 1454, LEFT OVERWING SLIDE NOT ARMED, R & R LEFT AFT EMERGENCY EXIT ESCAPE SLIDE PROXIMITY SWITCH 6WN1 IAW AMM 52-73-11, & TSM 52-21-00-810-808-A. LEFT AFT ESCAPE HATCH INDICATING CORRECTLY. OPS CHECKED OK.SDR CALA2020072001066Skin · dentedUPPER FUSELAGE FWD OF THE L1 DOOR WAS DENTED AT FRAME 15. EVALUATED DENT IAW SRM 53-00-11-283-005. DENT MEASURES 1.1"X1.1" X .020" DEEP. DENT IS IN RIVETED STIFFENED AREA AND IS CATEGORY C. DENT MUST BE REPAIRED WITHIN 200 FLIGHT CYCLES IAW PARAGRAPH 2.A.(1) SDR CALA2020072001065Battery Pack · dischargedEMER EXIT LIGHT TEST GIVES MESSAGE OF ESPU BATTERY EMERGENCY LIGHT &ESPU BATTERY . RESET BOTH ESPUS, NO HELP. REPLACED THE BATTERY PACK FOR ESPU 11WL & 12WL IAW AMM 33-51-38-000-002-A & 33-51-38-400-002-A, OPS CHECKED OK. ACCOMPLISHED THE INSPECTION OF THESDR YENA2020072000391Battery Pack · failedFLT 391, EMERGENCY LIGHT TEST FAILED BATTERIES AT 10WL,11WL, 13WL. REMOVED & REPLACED EMERGENCY LIGHT BATTERIES IAW AMM 33-51-38.SDR YENA2020072000390Battery · no testFLT 391, EMERGENCY LIGHT TEST FAILED BATTERIES AT 10WL,11WL, 13WL. REMOVED & REPLACED EMERGENCY LIGHT BATTERIES L IAW AMM 33-51-38.SDR YENA2020072000389Battery Pack · no testFLT 391, EMERGENCY LIGHT TEST FAILED BATTERIES AT 10WL,11WL, 13WL. REMOVED & REPLACED EMERGENCY LIGHT BATTERIES IAW AMM 33-51-38.SDR YENA2020072000388Transfer Sys · malfunctionedFLT 1334, DIVERTED. DURING DESCENT WHEN OUTER TANK FUEL TRANSFER VALVES OPENED, FUEL FROM RIGHT TANK OUTER CELL DID NOT TRANSFER TO THE INNER CELL EVEN THOUGH THE VALVE SHOWED OPEN ON ECAM. POSSIBLE MOMENTARY ECAM FOR FUEL R WING TK LO LVL. TOO BRIEF TO KNOWSDR GTIA2020072035266Accumulator · low pressureR4 DOOR ASSIST ACCUMULATOR LOW-SERVICED R4 DOOR ASSIST ACCUMULATOR TO PROPER PRESSURE IAW AMM 52-10-00SDR GTIA2020072035265Unknown · odorFUMES REPORTED BY LEAD FA ON DESCENT ALTITUDE APPROX 8000FT-FLT CREW COULDNT CONFIRM DEFECT. PERFORMED TSM 05-50-00-810-831, NO ODOR NOTED AT THIS TIME. PERFORMED ENG RUNS PER 71-00-00-810-847-A, NO FUMES OR ODOR NOTED.SDR GTIA2020071635259Bottle · low pressureL2 ASSIT BOTTLE LOW. SERVICED L2 DOOR ASSIST BOTTLE TO PROPER PRESSURE IAW AMM 52-22-00.SDR GTIA2020071635257Duct · unknownFUME EVENT AFT CABIN. PERFORMED ID OF THE CABIN CAUSE OF CABIN ODOR IAW TSM 05-50-00-810-831-A FOUND BLEED DUCT PCK TO CAUSE OF ODOR.SDR GTIA2020071335255Skin · dentedDURING WALK AROUND FOUND DENT ON LH ELEVATOR LOWER SURFACE. RAF 2542682-2 CREATED ITEM TRANSFERRED TO LTPR NRI 5001005810-0010-PERFORMED REPAIR OF DAMAGE AREA OF L/H ELEVATOR LOWER SKIN IAW SRM 55-21-11-300-032 REV.133.SDR YENA2020071600387Slide · defectiveDURING HEAVY MAINTENANCE, L1 DOOR REQUIRES CONTROL DEPLOYMENT DUE TO SAFETY PIN UNABLE TO BE INSTALLED; (REF NR 2020-172014) REMOVED AND INSTALLED SERVICABLE ESCAPE SLIDE AT DOOR 831 IAW AMM 25-62-44-000-012 AND 25-62-44-400-007-A.SDR YENA2020071600386Slide Raft · deformedDURING HEAVY MAINTENANCE, (REF NR 2020-172247) DEFORMATION SLIDE RAFT DOOR 841 AT FWD GALLEY AREA; (REF NR 2020-172247) R & R ESCAPE SLIDE RAFT DOOR 841 IAW AMM 25-62-44-400-803-A. OPS TEST OK.SDR YENA2020071600385Epsu · inoperativeDURING HEAVY MAINTENANCE, INOP EPSU EMERGENCY POWER SUPPLY UNIT EMERGENCY EXIT LT IN PASSENGER CABIN; (REF N/R 2020-172008) R & R EMERGENCY POWER SUPPLY UNIT (EPSU 11WL) ON EMERGENCY LT IN PASSENGER CABIN IAW AMM 33-51-38-400-001-A ITEM 1 THRU 4E AND AMM 33-51SDR GTIA2020071335249Cylinder · low pressureL2 DOOR ASSIST REQUIRES SERVICING. SERVICED THE L2 DOOR IAW AMM 52-10-00.SDR GTIA2020071335248Filter · odorMUSTY HUMID SMELL ON DESCENT SUSPECT PACK 1. FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED. R&R RECIRCULATION FILTERS IAW AMM 21-21-41 OPS CHECK GOOD AND DID CHECK OF PACK NO ODORS NOTIFIED.SDR YENA2020071300384Fan · failedFLT 1044, DIVERTED. CLIMBING FL 240-270, ODOR OF BURNING SUBSTANCE ACCOMPANIED BY LOUD WHINNING NOISE ON LT SIDE. AGAIN AT CRUISE ON FL 340 ODOR BECAME WORSE FOLLOWED NOISE SUBSIDING & VENT BLOWER ECAM STATUS. INSPECTED THE ACFT AND FOUND THE SOURCE OF THESDR AALA2020070989015Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE - AFT GALLEY WET AREA, DELAMINATED FLOOR PANEL, 261DF. REMOVED AND REPLACED FLOOR PANEL 261DF PER JOB CARD 26C26053014.SDR CALA2020071201045Battery · faultedEMERGENCY EXIT LIGHT SYSTEM HAS FAULT OF ESPU BATTERY EMER R. REPLACED EPSU BATTERY PACK IAW AMM 33-51-38-000-002-A & 33-51-38-400-002-A. OPS CHECKED OK. ACCOMPLISHED IDT INSPECTION OF REPLACED BATTERY IAW GMM 09-10-05.SDR GTIA2020070635235Unknown · odorFUME EVENT IN CRUISE, ISOLATED PACK 2, SMELL WENT AWAY. AT FL 180 SMELL CAME BACK. (PACKS A320 WITH MOD 31283/MP P7125 (FWC H2-F1 STND) AND WITH MOD 30626/MP K6443 (ENHANCED ECS) - FAULT CAUTIONS ASSOCIATED WITH OPERATIVE SIDE NOT DISPLAYED.
Back to Airbus A320-232