Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA2018120730814Skin · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON EXTERNAL SKIN LOCATED BTWN RIB 8-9 UPPER SURFACE ON LH WING; PERFORMED PERMANENT REPAIR LOC EXTERNAL SKIN BTWN RIB 8-9 UPPER SURFACE ON LH WING IAW EA 57-0384-18 REV.0 PART 1 & 2 / EC A18-990-01. REF. AEROMSDR YENA2018120730813Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM -Y1162 LOCATED BTW FR 68 TO FR 70 AT AFT GALLEY AREA; REF BP NR # 2018-395184 REPLACED FLOOR BEAM -Y1162 LOCATED BTW FR 68 TO FR 70 AFT GALLEY AREA IAW SRM A320 51-42-11 & 51-72-11 AND DRAWING D5SDR GTIA2018120632989Flashlight Assy · no testFWD OUTBOARD FA SEAT FLASHLIGHT WILL NOT TEST. ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) )-R/R FLASHLIGHT ASSY IAW AMM 25-60-00. NEXT INSPECTION DUE 12-5-2019. THIS CLEARS DMI 2394357-1. PLACARD REMOVED. MOC NOTIFIED.SDR YENA201812020812A/C Pack · odorFT 861, BOS-SJU. FUME/ODOR (SOCK ODOR) REPORTED BY CABIN CREW DURING DESCENT OUT OF 15000' ENG BLEED USED (APU OFF). C/W INFORMATION NOTICE 2017 SECTION A. A/C OK FOR SERVICE. RVR PACK 1 & 2 NO ODOR DETECTED PERFORMED EXTERIOR INSPECTION NO DEFECTS FOUND AS PSDR GTIA2018120322986Unknown · odorFUME EVENT AFT CABIN TURNED OFF PACK 2 SMELL DISSIPATED-PERFORMED IDENT OF COS REF TSM 05-50-00-810-831-A NO ODARS PRESENT AT THIS TIME APU CHECKED REF AMM 29-00-00 ENG RUN W/ FLT CREW & OPS CHECKED REF AMM 71-00-00SDR CALA2018120702497Stop Fitting · not reportedR1 DOOR FR16 NO.7 STOP FITTING BOTH INBD BOLT HOLES PRODUCE REJE CTABLE INDICATIONS DURING RFHEC INSPECTION A3NB-53-4-6304 GENERA TED BY V061690 ON HAECO LCQ NR 9294675 REMOVED AND REPLACED #7 INTERCOASTAL @ R1 DOOR FR16 IAW A320 SRM 51-72-11 BY MECH V913402 ISDR CALA2018120702496Plate · corroded(SPEC A3NB-53-3-6185 A-41 L-46 DOT 042) REINFORCEMENT PLATE U NDER STRGR 39R FROM FR 65-FR66 CORRODED IN MULTIPLE AREAS AAR N ONROUTINE 9019926 REMOVED AND REPLACED REINFORCEMENT PLAT UNDER STR 39R IAW A320 S RM 51-72-11-911-001. INSTALLED FASTENERS COMMONSDR CALA2018120702495Doubler · not reportedA3NB-53-3-6179(A33-124) AFT CARGO BAY FUSELAGE INTERNAL REINFOR EMENT DOUBLER IAW A320 SRM 51-72-11-911-001, INSTALLED FASTENERS COMMON TO LAV SERVICE CAP IAW ECRA 5341-01140 AAR NONROUTINE 9019887 REMOVED AND REPLACED INTERNAL REINFORCMENT DOUBLER IAW A320SDR CALA2018120702494Stringer · corroded(A3NB-533-6185)(L-69-003) CORROSION FOUND ON STR 39R AFT OF FR66 AAR NONROUTINE 9020117 REPAIRED STR 39 AFT OF FR66 IAW A320 SRM 53-00-13-300-001 AAR N ONROUTINE 9020117 ADD EMP:V918822SDR CALA2018120702492Frame · crackedLH FRAME 35 FORWARD AT LEVEL OF STRINGER 30 HOLE 2 IS CRACKED IN THE SIDE SHELL AT 7:00 INBOARD LOOKING OUTBOARD AN IN THE FRAME LAYER AT 6:00 AND 2:00 PER HAECO LCQ NON ROUTINE 9296424 GENERA TED BY V061633 REPAIRED LH FR35 FORWARD AT LEVEL OF STR30 HOLE#2 INSDR YENA2018120610810Power Supply · no testFT # 225, JFK-TPA. EMERG LIGHT TEST FAILED; REMOVED & REPLACED ESPU AT 11WL PER AMM 33-51-38.SDR YENA2018120610809Battery Pack · no testFT # 225, JFK-TPA. FAILED EMERG LIGHT TEST; REMOVED & REPLACED EMERGENCY LIGHT BATTERIES AT 11WL, 12WL & 13WL PER AMM 33-51-38. P/N OFF/ON 3214-31 S/N OFF094878 ON 831693. P/N OFF/ON 3214-31 S/N OFF 094867 ON 805202. P/N OFF/ON 3214-31 S/N OFF 094868 ON 9SDR YENA2018120610808Battery Pack · no testFT # 225, JFK-TPA. FAILED EMERG LIGHT TEST; REMOVED & REPLACED EMERGENCY LIGHT BATTERIES AT 11WL, 12WL & 13WL PER AMM 33-51-38. P/N OFF/ON 3214-31 S/N OFF094878 ON 831693. P/N OFF/ON 3214-31 S/N OFF 094867 ON 805202. P/N OFF/ON 3214-31 S/N OFF 094868 ON 9SDR YENA2018120610807Battery Pack · no testFT # 225, JFK-TPA. FAILED EMERG LIGHT TEST; REMOVED & REPLACED EMERGENCY LIGHT BATTERIES AT 11WL, 12WL & 13WL PER AMM 33-51-38. P/N OFF/ON 3214-31 S/N OFF094878 ON 831693. P/N OFF/ON 3214-31 S/N OFF 094867 ON 805202. P/N OFF/ON 3214-31 S/N OFF 094868 ON 9SDR AALA201812049036Cover · brokenEMERGENCY LIGHT COVER WAS BROKEN AT THE L1 DOOR. MAINTENANCE REPLACED THE LIGHT COVER AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.SDR AALA201812039011Pressure Panel · crackedCRACKED PRESSURE PANEL, AT FRAME 36, STRINGER 28, LBL Y2192. REPLACED THE PRESSURE PANEL IAW EO 5316Y209-001, AND EA 287487.SDR GTIA2018120312984A/C Pack · odorON DECENT THROUGH APPROXIMATELY FL 250, FLIGHT ATTENDANTS AND PILOTS NOTICED FUME EVENT PACK 2 WAS SHUT OFF AND FUMES SEEMED TO DISSIPATE-PER TSM 05-50-00-810-831A PACK 2 WAS FOUND TO BE SOURCE OF ODOR TRANSFERRED TO DMI 247045002 IAW MEL 21-52-01-14 CAT C DATSDR CALA2018120702491Stop Fitting · crackedL1 DOOR FR16 NO.7 STOP FITTING BOTH UPPER BOLT HOLES AND THE LOW ER INBD BOLT HOLE PRODUCES REJECTABLE INDICATIONS DURING RFHEC I NSPECTION AD 2017-22-03 A3NB-53-4-6304 GENERATED BY V061690 ON H AECO LCQ NR 9294683 REMOVED AND REPLACED LH FR 16 NO.7 INTERCOASTSDR AALA201812039015Floorboard · damagedFLOORBOARD 231AF WAS SPONGY. MAINTENANCE REPLACED THE FLOORBOARD IAW AMM 53-00-00-400-801-A, AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR CALA2018120202488Skin · crackedREFERENCE AAR LOG ITEM 9019374, ROTO PROBE INSEPCTION SHOWS CRAC K INDICATION IN MULTIPLE LAYERS @ FR35, STR 30L LOWER AFT HOLE AAR ACCOMPLISHED INTERIM REPAIR, PART 1 STEPS 1-23 OF ECRA 5331- 02304. NEED TO ACCOMPLISH A PERMANENT REPAIR PER PART 3 ON OR BE FOSDR CALA2018120202475Cleat · corrodedFWD CARGO COMPARTMENT FR31 STRINGER 39R-40R CLEAT HAS CORROSION. REMOVED AND REPLACED CLEAT ON FWD CARGO FR31 STRINGER 39R-40R. REMOVED CORROSION ORIGINAL MAT. .055", MATERIAL LOSS .031", MATERIAL REMAINING .029", MAX ALLOWED THICKNESS .004", FOUND OUT LIMITS SDR CALA2018120202474Cleat · damagedAFT CARGO CLEAT FR62 STR 41R-40R HAS ELONGATED HOLES. REMOVED AND REPLACED AFT CARGO CLEAT AT FR 62 STR 41R-40R IAW SRM 51-72-11-911-001.SDR CALA2018120202473Cleat · damagedAFT CARGO FRAME CLEAT HAS 2EA OUT OF ROUND HOLES FR63 ST41-42R. REMOVED AND REPLACED AFT CARGO CLEAT AT FR63 STR 41R-42R IAW SRM 51-72-11-911-001.SDR CALA2018120202472Cleat · corrodedFWD CARGO COMPARTMENT FR30 STRINGER 43R-43L CLEAT HAS CORROSION. REMOVED AND REPLACED 01 CLEAT (FABRICATED) ON FWD CARGO COMPARTMENT FR30 STRINGER 43R-43L IAW SRM 51-42-11-001, TREATED, PRIMED AND TOP COAT AREA IAW SRM 51-75-12-001.SDR CALA2018120202471Cleat · corrodedFWD CARGO COMPARTMENT FR32 STRINGER 42L-43L CLEAT HAS CORROSION FCD 5300-01440. REMOVED CORR AND REPLACED CLEAT ON FWD CARGO COMPARTMENT FR 32 STRINGER 42L-43L. ORIGINAL MAT .055",MATERIAL LOSS .011" MAT REMAINING .044" FOUND OUT LIMITS IAW SRM 51-74-00, SRM 5SDR YENA2018120490803Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM -Y450 AT AFT GALLEY AREA ON FRAME 65 (1 E/A); REF BP NR # 2018-374657 REPLACED FLOOR BEAM -Y450 .8 BTW FR 64 TO FR 67 AT AFT GALLEY AREA AS PER SRM A320 51-72-11 AND DRAWING # D53472816SDR YENA2018120490802Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM -Y450 AT AFT GALLEY AREA ON FRAME 65 (1 E/A); REF BP NR # 2018-374657 REPLACED FLOOR BEAM -Y464.8 BTW FR 64 TO FR 67 AT AFT GALLEY AREA AS PER SRM A320 51-72-11 AND DRAWING # D53472816.SDR YENA2018120490801Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM - Y450 AT AFT GALLEY AREA ON FRAME 65 (1 E/A); REF BP NR # 2018-374657 REPLACED FLOOR BEAM - Y464.8 BTW FR 64 TO FR 67 AT AFT GALLEY AREA AS PER SRM A320 51-72-11 AN DRAWING # D53472816SDR YENA2018120490800Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM +Y1162.5 BTW FR 66 TO FR 68 AT AFT GALLEY AREA; REF BP NR # 2018-374614 REPLACED FLOOR BEAM + Y1162.5 BTW FR 66 TO FR 68 AT AFT GALLEY AREA IAW SRM A320 51-72-11 AND DRAWING D53472780SDR YENA2018120490799Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM +Y1162.5 BTW FR 68 TO FR 69 AT AFT GALLEY AREA; REF BP NR # 2018-374616 REPLACED FLOOR BEAM +Y1162.5 BTW FR 68 TO FR 69 AT AFT GALLEY AREA IAW SRM A320 51-72-11 AND DRAWING D53472780SDR YENA2018120490798Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM - Y 1162.5 BTW FR 68 TO FR 69 AT AFT GALLEY AREA; REF BP NR # 2018-374620 REPLACED FLOOR BEAM - Y1162.5 BTW FR 68 TO FR 69 AT AFT GALLEY AREA IAW SRM A320 51-72-11 AND DRAWING D53472780SDR YENA2018120490797Web · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON SUPPORT WEB AT STR 23R AT AFT GALLEY AREA; REF BP NR # 2018-374680 REPLACED SUPPORT WEB AT STR 23R BTW FR 69 TO FR 70 AT AFT GALLEY AREA AS PER SRM A320-51-72-11 AND DRAWING # D53474180.SDR YENA2018120490796Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM -Y1162.5 BETWEEN FR 66-FR 68 AT AFT GALLEY AREA; REPLACED FLOOR BEAM-Y1162.5 BETWEEN FR 66-FR 68 AY AFT GALLEY AREA IAW SRM A320-51-72-11 AND DRWG D53472780. REF AEROMAN NR 2018-374619.SDR YENA2018120490795Stringer · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON STRINGER 43L LOCATED BTW FR 62 TO FR 63 IN AFT CARGO COMPARTMENT; REF BP NR # 2018-374610 REPLACED STRINGER 43L BTW FR 60 60 FR 64 IN AFT CARGO COMPARTMENT AS PER SRM A320 51-72-11 AND DRAWING # E 53470342.SDR YENA2018120490794Dummy Rail · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON RAIL DUMMY Y503.2 LOC BTW FR 12 TO FR 16 AT FWD GALLEY AREA; REF BP NR # 2018-374621 REPLACED RAIL DUMMY Y503.2 LOC BTW FR 12 TO FR 16 AT FWD GALLEY AREA AS PER SRM 51-72-11 AND DRAWING # 53112825SDR YENA2018120490793Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM +Y1292 LOC. BTW FR 12 TO FR 24 IN PASSENGER CABIN; REF BP NR # 2018-374613 REPLACED FLOOR BEAM LOC +Y1292 BTW FR 12 TO FR 24 IN PASSENGER CABIN AS PER SRM A32051-72-11 AND DRAWING # D53112812.SDR YENA2018120490792Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM -Y 1292 LOC BTW FR 12 TO FR 24 AT FWD GALLEY AREA; REPLACED FLOOR BEAM LOCATION -Y1292 BTW FR 12 TO 24 AT FWD GALLEY AREA AS PER SRM A320-51-72-11 AND DWG D53112812. ALL WORK ACCOMPLISHED ON AEROSDR YENA201812049791Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR BEAM +Y254 LOC. BTW FR 12 TO FR 24 AT FWD GALLEY AREA; REF BP NR # 2018-374617 REPLACED FLOOR BEAM LOC +Y254 LOC. BTW FR 12 TO FR 24 AT FWD GALLEY AREA AS PER SRM A320-51-72-11 AND DRAWING # D53110 9SDR YENA201812049790Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED FLOORBEAM -Y 254LOC BTW FR 12 TO FR 24 AT FWD GALLEY AREA; REPLACED FLOOR BEAM LOC -Y 254 BTW FR12 TO 24 AT FWD GALLEY AREA AS PER SRM A320-51-72-11 AND DRWG # D53110920,D53112816. ALL WORK ACCOMPLISHED ON AERSDR YENA201812049789Warning Message · illuminatedFT # 714, DFW-BOS. EMERGENCY DECLARED. AT CRUISE ALT, F/CTL ALTN LAW, F/CTL ELEV SERVO FAULT. ELAC 1 PITCH FAULT. F/CTL STABALIZER JAM; SUPPLEMENTAL INFORMATION TO FOLLOW.SDR GTIA201812032983Unknown · odorDIRTY SOCK SMELL FROM TOP OF DESCENT DOWN TO ABOUT 10,000FT. -PERF. ENG. RUN IAW AMM 71-00-00 TO MATCH A/C CONFIG. UPON EVENT & COULD NOT DUPLICATE. PERF. VISUAL INSP. OF APU & NO DEFECT. NO DIRTY SMELL NOTED IN CABIN OR CKPT W/ ENG. OR APU BLEED.SDR CALA2018120202462Idg · faultedGEN 1 FAULT REF TSM TASK 24-20-00-810-803-A, STEP 4 A . INSPECTED POWER FEEDER CONNECTOR AT FIREWALL. NO BURNING/ARCING DAMAGE OR CORROSION. RECONNECTED POWER FEEDER CONNECTOR. VERIFIED NO BURNING/ARCING OR SIGNS OF CORROSION ON POWER FEEDER CONNECTOR AT PYLONSDR CALA2018120202461Door Frame · crackedL1 DOOR FRAME 16 STOP FITTING NR 1 LOWER INBOARD HOLE IS CRACKED IN FRAME LAYER AT 7:00 ON REF 9296599 SPEC A3NB-53- 4-6304 AD 2017-22-03. REPAIR ACCOMPLISHED IAW ECRA 5311-02046 PER ECRA 5311-02046PATR 1 STEP 2.SDR CALA2018120202455Stringer · corrodedSTR 40R TO STR 41R BETWEEN FR 67-FR 68 HAS MULTIPLE CORRODED FASTENERS. REMOVED AND REPLACED FASTENERS AT STR 40R BETWEEN FR 67-FR 68. BLENDED CORROSION AT STR 41R BETWEEN FR 67-FR 68. FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED STR 41R AT FR 64-FR 69. RESDR YENA201812037788Filter · failedFT # 878, LAS-BOS. FA#2 REPORTS DIRTY SOCK ODOR ROW 11-14. PERFORMED ODOR RECOGNITION ISOLATION PRPROCEDURE. ODOR GONE WITH PACK 1 OFF. ( PACKS - SINGLE (SPEEDBRAKES OK) (N503-N665) ); REMOVED AND REPLACED OZONE FILTER PACK IAW AMM 21-51-41. RUN PACK 1 NO SMWESDR GTIA2018112972981Panel · looseDURING CLIMB VERY STRONG VIBERATION WERE FELT. CLIMB SPEED WAS 332/.79. REDUCED SPEED TO 300/.78 VIBERATION DISAPPEARED, F/A REPORTED ALO THE SAME-T/S VIBERATION IAW TSM 05-5000-810-801-A FOUND PANEL 192BT LOOSE. TIGHTENED IAW 53-35-00SDR AALA201811299016Unknown · odorTHE AIRCRAFT WAS GROUNDED. CABIN ODOR OCCURRED DURING DECENT. A SUPPLEMENTAL REPORT TO BE SUBMITTED TO INCLUDE AIRCRAFT TOTAL TIME, CORRECTIVE ACTION AND PART INFORMATION. (OPEN)SDR CALA2018120102442Stringer · corrodedAFT CARGO BAY STR 39R AT FR58-64 IS CORRODED. AFTER EVALUATION OF STR 39R AT FR58-64 FOUND CORROSION NEXT TO PRODUCTION SPLICE, PROXIMITY OF MINIMUM REPAIR DISTANCE NOT MEET, FOUND TO BE OUT OF LIMITS. PREFORMED REPAIR IAW SRM 53-00-13-300-001 AND SRI 53-00-13SDR CALA2018120102441Stringer · corrodedAFT CARGO BAY STR 40R AT FR58-64IS CORRODED. AFTER EVALUATION OF STR40R AT FR58-FR64 FOUND CORROSION UNDER FR 59. FOUND TO BE OUT OF LIMITS DUE TO LOCATION OF CORROSION. PERFORMED REPAIR IAW SRM 53-00-13-300-001 AND SRI 53-00-13-205-001.SDR CALA2018120202447Check Valve · brokenY RSVR LO LVL DISPLAYED ON UPPER ECAM SCREEN. HYD FOUND CHECK VALVE ON YELLOW SYSTEM MANIFOLD TO BE BROKEN. REPLACING CHECK VALVE AND THEN WILL LEAK CHECK.
Back to Airbus A320-232