Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017091803219Power Supply · inoperativeEPSU 13WL INOPERATIVE. REMOVED AND REPLACED THE EPSU IAW 33-51-38-000-001-A, AND 33-51-38-400-001-A. OPS CHECKED GOOD IAW AMM 33-51-38-400-001-A STEP 4.D.SDR AALA201709269034Box Beam · crackedCRACK INDICATION ON RIGHT SIDE BOX BEAM UPPER FLANGE AFT HOLE, -Y1622, FR 43. REPAIRED THE BOX BEAM IAW EO 5315Y066.SDR AALA201709269033Box Beam · crackedCRACK INDICATION ON THE LEFT SIDE BOX BEAM UPPER FLANGE, AFT HOLE AT Y1622, FRAME 43. REPAIRED THE BOX BEAM IAW EO 5315Y066.SDR YENA201709170774Unknown · odorDIRTY SOCK ODOR, FROM TOP OF DESCENT AT FL 360 TO MID TEENS. STRONGEST ODOR WAS IN THE 20'S WITH POWER IDLE, NR 1 ENGINE CHANGED LAST WEEK, NO HISTORY SINCE. ACFT IS OK FOR SERVICE. NO REPORT OF ODOR FROM INFLIGHT.SDR YENA201709170771Battery Pack · no testDURING A WEEKLY EMERGENCY LIGHT TEST, THE SYSTEM FAILED. FOUND THE EPSU BATTERY AT FAULT 10WL AND 13WL. R & R BOTH BATTERY PACKS IAW AMM 33-51-38. OPS TESTED OK.SDR YENA201709170770Battery Pack · no testDURING A WEEKLY EMERGENCY LIGHT TEST, THE SYSTEM FAILED. FOUND EPSU BATTERY AT FAULT 10WL AND 13WL. R & R BOTH BATTERY PACKS IAW AMM 33-51-38. OPS TESTED OK.SDR GTIA2017091702173Seal · leakingDIRTY SOCK ODOR STARTED AROUND 3000 FT IT WAS VERY FAINT IN THE COCKPIT BUT USED OXYGEN MASKS .THE F/A'S REPORTED A DIRTY SOCK ODOR ON THE GROUND AFTER. ODOR SEEMS WORSE IN CABIN. PERFORMED TSM 05-50-00-810-831A AND R & R NR 1 AND NR 2 ENGINE DEOILER SEALS ISDR YENA201709170765Strap · crackedDURING HEAVY MAINTENANCE, CRACK WAS DISCOVERED ON THE NR 4 LEFT ELEVATOR HINGE ARM STRAP END. REMOVED AND REPLACED THE STRAP IAW SRM 51-42-11.SDR YENA201709170764Strap · crackedDURING HEAVY MAINTENANCE, CRACKS WERE DISCOVERED ON THE RT NR 4 ELEVATOR HINGE ARM STRAP. REMOVED AND REPLACED THE STRAP IAW SRM 51-42-11.SDR YENA201709160769Unknown · odorSTRONG DIRTY SOCK ODOR AND FUMES DURING DESCENT THROUGH 8000 FT, THROUGHOUT LANDING. PERFORMED A VISUAL INSPECTION OF APU EXTERNAL COMPONENTS IAW TSM 49-00-81-810-874-A. REMOVED BLEED DUCT AND EXAMINED FOR OIL LEAK. NO LEAK NOTED. RAN APU, AND NO ODOR NOTED.SDR GTIA2017091602172Bottle · low pressureL2 DOOR ASSIST BOTTLES LOW. SERVICED L2 DOOR ASSIST BOTTLES IAW AMM 52-10-00.SDR YENA201709150773Battery Pack · no testEMERGENCY LIGHT BATTERY FAILED A CAPACITY TEST. R & R THE BATT IAW AMM 33-51-38, AND OPS CHECKED GOOD.SDR YENA201709150772Battery Pack · no testEMERGENCY LIGHT BATTERY FAILED A CAPACITY TEST. R & R THE BATTERY IAW AMM 33-51-38, OPS CHECKED GOOD.SDR YENA201709150768Unknown · odorRETURNED TO GATE. AFTER ENGINE START, A STRONG ODOR OF FUEL IN AFT CABIN, WORSE WITH TIME. REPOSITIONED THE ACFT INTO WIND TO TROUBLESHOOT. CABIN REPORTED ODOR AFTER ENGINE START, IN AFT & MID CABIN. ODOR WORSE OVER THE NEXT 10 MINUTES. RETURNED TO GATE. SDR GTIA2017091502170Cylinder · low pressureDURING RON CHECK FOUND L1 PAX DOOR ASSIST BOTTLE BELOW RON LIMITS. SERVICE L1 PAX DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR CALA2017091503209Bottle · low pressureL1 DOOR EMERGENCY BOTTLE HAD LOW PRESSURE. REMOVED AND REPLACED L1 DOOR DAMPER AND EMERGENCY OPERATION CYLINDER. LEAK CHECKED GOOD.SDR CALA2017091503208Slide · low pressureR1 DOOR SLIDE PRESSURE GAUGE ON GREEN LINE. REPLACED THE SLIDE IAW AMM 25-62-44.SDR CALA2017091503207Light · missingSEAT 29C EMERGENCY LIGHT MISSING. INSTALLED THE EMERGENCY LIGHT. OPS CHECKED GOOD.SDR CALA2017091503180Oven · odorIN AFT GALLEY OVEN AT POS 407 PRESENTD SLIGHT ELECTRICAL ACRID ODOR. OVEN SHUTOFF. NO CIRCUIT BREAKERS TRIPPED. R & R, OPS CHECKED OK, IAW AMM 25-35-98.SDR YENA201709150763Unknown · odorAFTER DESCENT WITH POWER AT IDLE, ON LEVEL OFF WITH POWER UP, DIRTY ODOR IN COCKPIT. ODOR STRONG AT FLIGHT POWER UP, BUT DISAPPEARS FAIRLY QUICKLY WITH CONSISTENT POWER. HAPPENED TWICE ONCE ON EACH DESCENT. COMPLIED WITH INFORMATION NOTICE 2017-T015B SECTIOSDR CALA2017091503159Pin · damagedEMERGENCY LIGHTS TEST FAILED FOR AFT LT EXTERIOR LOADS. R & R THE EPSU 13WL. R & R THE BATTERY 13WL. R & R THE AFT R2 DOOR SLIDE. REPAIRED THEWIRING AT LAVATORY D, AFT EMERGENCY LIGHTS PIN E ON CONNECTOR 7202VC & FLOOR LIGHT EQNVR1, WIRE 4106-A20. EPSU & BSDR YENA201709130762Structure · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER STRUCTURE, FRAME 68 STRINGER 23L. REPAIRED IAW SRM 53-41-14-300-001.SDR YENA201709110761Window · failedDURING APPROACH, A LOUD CLICKING SOUND WAS HEARD FROM THE AREA OF THE CAPTAIN`S AFT WINDOW AND STORAGE BIN. SHORTLY AFTER THE CLICKING SOUND, BOTH PILOTS NOTED A SIGNIFICANT ELECTRICAL ODOR.THE SOUND STOPPED AFTER ABOUT 90 SECONDS THE ODOR CONTINUED . NO SMOKESDR AALA201709129026Cover · missingSLIDE ARMED COVER MISSING ON L4 DOOR. INSTALLED SLIDE ARMED COVER IAW AMM.SDR AALA201709129024Lens · missingEXIT LIGHT LENS AFT OF R4 DOOR MISSING. REPLACED SIDEWALL MOUNTED EXIT LIGHT IAW AMM.SDR CALA2017091103156Retainer · brokenL1 DOOR SLIDE HAS BROKEN RETAINING CLIP FOR THE DECORATIVE COVER. REMOVED AND REPLACED TH EL1 DOOR SLIDE IAW AMM 52-62-44-40 0-007-A, AND 52-62-44-000-007-A.SDR CALA2017091103155Power Supply · failedEMERGENCY LIGHT POWER SUPPLY UNIT FAILED AT THE L1 DOOR. REPLACED THE EPSU IAW AMM 33-51-38-00-0-001.SDR CALA2017091103154Safety Wire · brokenLEFT AFT PAX DOOR EVACUATION SLIDE RELEASE BAR MECHANISM SAFETY WIRE BROKEN. REPLACED LH AFT SLIDE ASSY PER AMM 25-62-44/401SDR CALA2017091103153Battery · no testRIGHT OVERWING EMERGENCY LIGHT BATTERY DID NOT PASS A BITE CHECK. REPLACED THE BATTERY AND PERFORMED BITE CHECK IAW AMM 33-51-00-710.SDR CALA2017091003124Slide · debondedLT OVERWING SLIDE EXIT DOOR T/E IS DISBONDED. REPLACED SLIDE, RAMP-OFFWING LT REF MM 25-62-46/401.SDR CALA2017091003123Battery · dischargedAFT FA EMERG FLASHLIGHT NOT FLASHING RED ON PREFLIGHT. REPLACED FLASHLIGHT BATTERY, FLASHING RED LIGHT OPS CHK NORMAL.SDR CALA2017090903113Lens · damagedRIGHT FORWARD SLIDE INDICATION INOP. FROSTED AND EXTREMELY HARD TO READ. REPLACED DAMAGED LENS IAW EC/RA 2523-01203 PART 3 PERMANENT REPAIR.SDR CALA2017090903112Battery · dischargedEMERGENCY LIGHT TEST FAILED AT PTP PANEL. REPLACED BATTERY AT EPSU 11WL NOW OP TEST OK FOR SERVICE REF AMM 33-51-38 PB401.SDR CALA2017090903095Fan · failedAIR RETURN DUE TO SMOKE EVENT. CREW ISOLATED TO VENT EXTRACT FAN PER SMOKE EVENT FORM. EMERGENCY DECLARED. FOUND EXTRACT FAN 18HQ FAULT IN MCDU.ALSO CB AE2 POPPED. REMOVED AND REPLACED EXTRACTOR FAN 18HQ IAW AMM 21-26-51-000-001 -A AND 21-26-51-400-001A. PEFORSDR CALA2017090903100Epsu · faultyEPSU 11WL FAULTED. R & R THE EPSU.SDR AALA201709119005Light · inoperativeEMERGENCY LIGHT SEAT MOUNTED ROW 7L INOPERATIVE. REPLACED LIGHT ASSY PER AMM.SDR YENA201709080758Battery · no testDURING T/C A320-33-51-00-710-003 BATTERY 10WL FAILED CAP TEST. EMERGENCY POWER SUPPLY UNIT & BATTERY FAILED TEST AT LOC 11WL. DURING T/C A320-33-51-00-710-003 BATT 12WL FAILED CAP TEST. EMERGENCY POWER SUPPLY UNIT AT 13WL FAILED SYSTEM TEST; R & R BATT 10WL IASDR YENA201709080757Battery Pack · no testBATTERY 12WL FAILED A CAPACITY TEST. R & R THE BATTERY IAW 33-51-38 TESTED NORMAL. OPS CHECKED GOOD.SDR YENA201709080756Power Supply · no testEMERGENCY POWER SUPPLY UNIT & BATTERY FAILED TEST AT LOC 11WL. R & R THE EPSU & BATTERY AT 11WL IAW AMM 33-51-38. OPS CHECKED GOOD.SDR YENA201709080755Battery Pack · no testDURING T/C A320-33-51-00-710-003 BATTERY 10WL FAILED A CAPACITY TEST. R & R THE BATTERY IAW 33-51-38. TESTED NORMAL.SDR YENA201709080754Battery · failedDURING T/C A320-33-51-00-710-003, BATTERY 10WL FAILED A CAPACITY TEST. R & R THE BATTERY IAW 33-51-38. TESTED NORMAL.SDR YENA201709080753Battery Pack · failedDURING T/C A320-33-51-00-710-003 BATTERY 10WL FAILED A CAPACITY TEST. EMERGENCY POWER SUPPLY UNIT & BATTERY FAILED TEST AT LOC 11WL. R & R THE BATTERY 10WL IAW 33-51-38. TESTED NORMAL. R & R EPSU & BATTERY AT 11WL IAW AMM 33-51-38, OPS CHECKED GOOD. R & R SDR CALA2017090803094Buckle · brokenL1 DOOR SLIDE HAS A BROKEN BUCKLE. REPLACED THE DOOR SLIDE ASSY.SDR CALA2017090803077Post · crackedLEFT AFT EMERGENCY EXIT DOOR VERTICAL SUPPORT CRACKED. REMOVED AND REPLACED THE VERTICAL SUPPORT IAW SRM 51-72-11-911-001, AND ER 5100R01017 REV D.SDR GTIA2017090702169Bottle · low pressureL1 DOOR ASSIST BOTTLE LOW. SERVICED L1 DOOR ASSIST BOTTLE IAW AMM 52-10-00SDR YENA201709070752Dummy Rail · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE DUMMY RAIL Y503.2, FRAMES 12 TO 16. REPLACED THE DUMMY RAIL IAW SRM 51-41-11 AND SRM 51-72-11.SDR YENA201709070751Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON THE FLOOR SUPPORT +Y512, FRAME 64 TO 67+10. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11 AND DRAWING D53472815.SDR YENA201709070750Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LOWER SUPPORT AT STRINGER 23L AT AFT GALLEY AREA FROM FRAMES 66 - 68. REPLACED THE SUPPORT IAW A320 SRM 51-42-11.SDR YENA201709070749Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR SUPPORT, -Y1292, FRAMES 64 - 66+5. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DRAWING D53472831.SDR YENA201709070748Floor Support · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON FLOOR SUPPORT, +Y512, FRAMES 64 - 67+10. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11, AND DRAWING D53472815.
Back to Airbus A320-232