SDR USAA2014091700014Battery · dischargedC11 CHECK EMER LIGHTS FAIL SYS TEST ON CIDS PANEL SYS FAULTS LT FWD EPSU. REPLACED LT FWD EPSU DUE TO PIN BEING PUSHED BACK IN THE ELEC CONNECTOR, ALSO REPLACED BATTERY PACK FOR SAME EPSU DUE TO LOW VOLTS IAW AMM 33-51-38.SDR USAA2014091700009Slide · delaminatedS2 CHECK LT OVERWING SLIDE HAS DELAMINATION. REPLACED IAW JOB CARD 26C19053012.SDR USAA2014091700006Attach Bracket · crackedC11 CHECK BOTH LOWER ATTACH BRACKETS ON R1 DOOR SLIDE ARE CRACKED. REPLACED R1 DOOR SLIDE ASSEMBLY IAW JOB CARD 26L00025010.SDR USAA2014091700005Power Supply · damagedC11 CHECK EMER LIGHTS FAIL SYS TEST ON CIDS PANEL SYS FAULTS LT FWD EPSU. REPLACED LT FWD EPSU DUE TO PIN BEING PUSHED BACK IN THE ELEC CONNECTOR, ALSO REPLACED BATTERY PACK FOR SAME EPSU DUE TO LOW VOLTS IAW AMM 33-51-38.SDR CALA2014111092671Spar · mechanic errorNUMBER 2 PYLON LOWER SPAR WEB MIS-DRILLED DURING ACCOMPLISHMENT OF SRM 54-51-12. INTERIM REPAIR ACCOMPLISHED IAW ECRA 5450-02258. REPAIR HAS BEEN APPROVED AS INTERIM FOR 1 MONTH IAW RDAS 80003171-003-2014 DATED 9-10-14. A NEW RDAS THAT PROVIDES THE INSPECTSDR USAA2014091600004Controller · faultedRETURN TO FIELD FOR CABIN PRESSURIZATION SYS NR 2 FAULT. REPLACED CABIN PRESS CONTROLLER IAW AMM 21-31-34 BITE TEST GOOD. REPLACED OUTFLOW VLV AS PRECAUTIONARY IAW AMM 21-31-51.SDR CALA2014091892238Slide · deployedDOOR 1R SLIDE DEPLOYED. REPLACED 1R DOOR SLIDE IAW AMM 25-62-44-000-002, CHECKED OK.SDR CALA2014091892237Slide · defectiveDURING EMER LIGHT TEST, GOT EPSU EXT LOAD FWD LT MSG. REPLACED DOOR SLIDES L1 & R1 IAW AMM 25-62-44-400. EMER LIGHT TEST PASSED.SDR USAA2014091500008Fastener · looseAIRFRAME VIBRATION, LIGHT TO MODERATE INTENSITY. FOUND LOOSE & WORN HARDWARE ON NLG DOOR ASSEMBLY AFT RT. REPLACED LOWER BOY PIVOT POINT & HARDWARE, DIDN'T DISTURB ADJUSTMENT IAW AMM 32-22-13-410-001A.SDR CALA2014091892231Stringer · corrodedSTRINGER 40L HAS CORROSION BETWEEN FRAME 63 & 64. FOUND NO ALLOWABLE LIMITS FOR STRINGER DAMAGE IN SRM 53-41-13 PG 101. REMOVED STRINGER 40L BETWEEN FRAME 60 & 64. REPLACED IT IAW SRM 51-42-11 PG 24 SRI INSPECTION NOT REQUIRED.SDR CALA2014091892229Stringer · corrodedSTRINGER 41R HAS CORROSION BETWEEN FRAME 63 & 64. FOUND NO ALLOWABLE LIMITS FOR STRINGER DAMAGE IN SRM 53-41-13 PG ,101. REMOVED STRINGER 41R FROM FRAME 58 TO 64 & SPLICE AT FRAME 58. REPLACED WITH NEW STRINGER & FACTORY SPLICE BETWEEN FRAME 58 & 64.SDR CALA2014091892227Spar · mechanic errorNUMBER 2 PYLON LOWER SPAR WEB MIS-DRILLED DURING ACCOMPLISHMENT OF SRM 54-51-12. INTERIM REPAIR ACCOMPLISHED IAW ECRA 5450-02258. REPAIR APPROVED FOR 1 MONTH IAW RDAS 80003171-003-2014 DATED 9-10-14. A NEW RDAS THAT PROVIDES THE INSPECTION & THRESHOLD MUSTSDR YENA20140912196Wire Harness · damagedDURING MAINTENANCE CHECK, FOUND 23C EMERGENCY LIGHT IN SEAT INOPERATIVE. REPAIRED SEAT HARNESS IAW STANDARD PRACTICES. OPS CHECK GOOD.SDR YENA20140912192Power Supply · failedCREW REPORTED THAT EMERGENCY EXIT LIGHTS AT AFT GALLEY DID NOT COME ON WHEN GEAR WAS DOWN. R & R 13WL EPSU IAW AMM 33-51-38 ALL EMERGENCY LIGHTS, OPS CHECKED GOOD.SDR YENA20140911194Connector · burnedCREW DECLARED AN EMERGENCY DUE TO F/A REPORT OF ELECTRICAL ODOR. PERFORMED ELECTRICAL ODOR SYS INTEGRITY CHECK, FOUND DISCOLORED PINS AT 25 RT XEB J1 CONNECTOR & NO POWER TO ZONE 2. R & R XEB AT 25RT, SEAT TO SEAT CABLE AT 24-25RT, VDU'S AT 25D & 25F, AND ZOSDR USAA2014091100011Cylinder · lowDOOR 1L ASSIST CYLINDER PRESS IS LOW. SERVICED DOOR 1L ASSIST CYLINDER TO PROPER PRESS IAW AMM 52-10-00-614-001-A. NO LEAKS NOTED.SDR YENA20140910187Reservoir · lowDURING DESCENT ECAM HYD LOW LEVEL GREEN INDICATOR BOTTOM OF ECAM ACTION COMPLETED. LANDING GEAR GRAVITY EXTENSION PROCEDURES APPLIED. LANDING GEAR EXTENSION RESET WAS ACCOMPLISHED IAW AMM 32-33-00, IAW TSM 29-11-810-803, CLEANED GREEN HYD QTY SENSOR. FOUND GRSDR YENA20140910186Flap System · malfunctionedDURING FINAL APPROACH, SELECTED FLAPS 2 AND RECEIVED A F/CTRL FLAPS LOCKED WING TIP BRAKE ON ECAM. ACCOMPLISHED FLAPS/SLATS SYS RESET IAW AMM 27-50-00. NO FAULTS NOTED ON FLAP/SLATS, OPS CHECK NORMAL.SDR CALA2014091292106Battery · dischargedEPSU BATTERY EMER LIGHT MSG ON PTP PANEL AFTER EMER LIGHT OPERATIONAL TEST. REPLACED BATTERY IAW AMM 33-51-38. OPERATIONS CHECKED OK.SDR USAA2014091000006Valve · inoperativeRETURN TO FIELD DUE TO NR 2 ENG BEARING 4 OIL SYS HIGH PRESS INDICATION DURING CRUISE. SWAPPED NR 4 BEARING SCAVENGE VLV TO ENG NR 1, NO HELP. REPLACED NR 4 BEARING SCAVENGE VLV ON ENG NR 1.SDR USAA2014091000005Connector · disconnectedROW 7 LT EMER LIGHT INOPERATIVE. REINSTALLED CONNECTOR ON EMER LIGHT AT ROW 7 LT. OPERATIONS CHECKED GOOD IAW AMM 33-51-19.SDR USAA2014090900007Actuator · malfunctionedRETURNED TO FIELD FOR ENG NR 2 COMPRESSOR VANE FAULT ON TAKEOFF ROLL. REPLACED ENG 22 VSV ACTUATOR IAW JOB CARD 26T40075005. LEAK CHECKED GOOD.SDR USAA2014091100013Floor Panel · delaminatedS2 CHECK DELAMINATION ON CABIN FLOOR PANEL 251RF BETWEEN FRAME 58 TO 62, Z-500, -Y254. REPLACED CABIN FLOOR PANEL 251RF IAW IRM 9701 REVISION G.SDR USAA2014091100012Floor Panel · delaminatedS2 CHECK DELAMINATION ON CABIN FLOOR PANEL 232WF BETWEEN FRAME 32 TO 35, Z-500, -Y254. REPLACED CABIN FLOOR PANEL 232WF IAW IRM 9701 REVISION G.SDR YENA20140908188Battery Pack · failedDURING MAINTENANCE, RT EMERGENCY LIGHT BATTERY FAILED CAPACITY TEST. R & R RT EMERGENCY LIGHT BATTERY IAW AMM 33-51-00 BITE TEST OK AND OPS CHECK GOOD, REF TASK A320-33-51-00-710-003.SDR YENA20140908189Battery Pack · no testDURING MAINTENANCE, LEFT EMERGENCY LIGHT BATTERY FAILED CAPACITY TEST. R & R LT EMERGENCY LIGHT BATTERY IAW AMM 33-51-00, BITE TEST OK AND OPS CHECK GOOD, REF TASK A320-33-51-00-710-003.SDR USAA2014090900009Floor Panel · delaminatedS2 CHECK DELAMINATION ON UPPER SURFACE OF FLOOR PANEL 231VF BETWEEN FRAME 32 TO 35, Z-500, Y0. REPLACED FLOOR PANEL 231VF IAW IRM 9701 REVISION G.SDR USAA2014090900008Floor Panel · damagedS2 CHECK AREA OF SURFACE DAMAGE ON UPPER SURFACE OF FLOOR PANEL 231QF BETWEEN FRAME 28 TO 32, Z-500, -Y254. REPLACED FLOOR PANEL 231QF IAW IRM 9701 REVISION G.SDR CALA2014090992105Slide · damagedRIGHT OVERWING SLIDE PACK SKIN PEELING OFF. HONEYCOMB STRUCTURE VISIBLE. AREA APPROX 6 INCHES X 6 INCHES, SIGNS OF CORROSION. REPLACED RT OVERWING ESCAPE SLIDE IAW AMM 25-62-42. TESTED OK.SDR YENA20140907185Pressure Switch · faultedFLIGHT DIVERTED DUE TO BLUE HYDRAULIC PUMP HAD A LOSS OF PRESSURE. PERFORMED TSM TASK 29-12-00-810A AND FOUND BLUE ELECTRIC PUMP PRESSURE SWITCH FIN 2074GJ AT FAULT. R & R PRESSURE SWITCH IAW AMM 29-12-17. OPS CHECK AND LEAK CHECK OK. FAULT NO LONER IN VIESDR CALA2014090992098Skin · damagedRIGHT ELEVATOR UPPER SURFACE HAD A 1.5 INCH X 1.5 INCH AREA OF WATER INGRESS, 26 INCHES FROM THE INBD END OF THE ELEVATOR & 26 INCHES FWD OF THE TE ZONE 1. DAMAGE WAS R & R ACP IAW SRM 55-21-11 PARA 5 E FIG 205 CONFIG 1. REPAIR REQUIRES INSPECTION IAW SRI55-SDR CALA2014090992097Skin · damagedLEFT ELEVATOR UPPER SURFACE HAD A 2.0 INCH BY 1.5 INCH AREA OF WATER INGRESS, 30 INCHES FROM THE OTBD END OF THE ELEVATOR & 13 INCHES FWD OF THE TE, ZONE 1. DAMAGE WAS R & R ACP IAW SRM 55-21-11 PARA 5 E FIG 205 CONFIG 1. REPAIR REQUIRES INSPECTION IAW SRI55SDR YENA20140906180Controller · failedAIR RETURN, DURING CLIMB CABIN PRESSURE SYS 1 & 2 FAULTED AT 7000 FEET. PERFORMED TSM 21-31-00. R & R CONTROLLERS 1 AND 2 IAW AMM 21-31-34. OPS CHECKED GOOD. FUNCTIONAL CHECKED, PRESSURIZED ACFT IAW AMM 05-53-00, NO FAULTS FOUND.SDR YENA20140906179Controller · failedAIR RETURN, DURING CLIMB CABIN PRESSURE SYS 1 & 2 FAULTED AT 7000 FT. PERFORMED TSM 21-31-00. R & R CONTROLLERS 1 AND 2 IAW AMM 21-31-34. OPS CHECKED GOOD. FUNCTIONAL CHECKED, PRESSURIZED ACFT IAW AMM 05-53-00, NO FAULTS FOUND.SDR USAA2014090400009Fuel Door · corrodedS2 CHECK LEVEL 2 FRETTING CORROSION ON RT WING LOWER FUEL DOOR 640PB BETWEEN RIB 19 - 20 & ALSO BETWEEN STRINGER 8R TO 11R. REPLACED RT WING LOWER FUEL DOOR 640PB IAW SRM 57-27-11 & 51-23-11.SDR YENA20140902177Power Supply · no testR2 & L2 DOOR EXIT SIGNS DID NOT ILLUMINATE DURING EMERGENCY LIGHT TEST. REPLACED EPSU 13WL IAW AMM 33-51-38. OPS CHECKED NORMAL.SDR USAA2014090400006Hinge Pin · corrodedNLG TORQUE LINK CTR HINGE PIN BOLT HAS PITTING UNDER HEAD & SHOWS DEFECT WITH PENETRANT INSPECTION. REPLACED IAW JOB CARD 26C71032003.SDR USAA2014090200025Hook And Loop · wornTHE FWD GALLEY MEGA PHONE COVER WILL NOT STAY IN POSITION, HOOK & LOOP IS WORN. REPLACED HOOK & LOOP ON FWD MEGA PHONE COVER AS REQUIRED.SDR YENA20140901175Wire · brokenFWD BULKHEAD EMERGENCY LIGHT INOPERATIVE, FOUND TO HAVE A BROKEN WIRE. PERFORMED WIRE SPLICE REPAIRS IAW 3351-1960 & 3351-1961 GOING TO 7441VS, 361WL1. OPS CHECKED GOOD. ACFT OK FOR SERVICE, IAW ESPM 20-53-21 FIG 010, REPAIR 1-D.SDR YENA20140901174Fcu · odorCREW DECLARED AN EMERGENCY AND ACFT DIVERTED. SMOKE & STRONG ACRID FUMES FROM FCU DURING CRUISE. ACCOMPLISHED TSM TASK 24-00-00 810-823-A INSPECTED REPORTED SUSPECT AREAS AND FOUND FCU TO HAVE ELECTRICAL BURNING ODOR INTERNALLY. R & R FCU IAW AMM 22-81-12. SDR CALA2014090392057Threshold · corrodedR2 DOOR THRESHOLD BEAM CORRODED AT FRAME 68 IN AFT CABIN. MATERIAL LOSS WAS 100% AT FRAME 68 NUTPLATE. OUT OF LIMITS IAW SRM 53-41-14 FIG 101. FABRICATED REPAIR ANGLE & FILLER & INSTALLED IAW SRM 53- 41-14 FIG 201 & MT.SDR YENA20140831173Seal · leakingDIVERTED, PACK NR 2 UNABLE TO MAINTAIN CABIN TEMPERATURE IN FLIGHT AND ON THE GROUND. TROUBLESHOT AND FOUND SLEEVE AND SEALS DISLODGED ON NR 2 ACM. REPLACED SEALS AND REINSTALLED SLEEVE IAW AMM 21-52-21. NR 2 PACK LEAKS CHECK GOOD IAW AMM 21-52-00.SDR CALA2014091892239Stringer · corrodedSTRINGER 41L IS CORRODED BETWEEN FRAME 63 - 64 IN AFT CARGO PIT. REMOVED DAMAGED SECTION. FABRICATED & INSTALLED STRINGER & REPAIR SPLICE IAW SRM 53-00-13 FIG 201. REPAIR REQUIRES SRI INSPECTIONS IAW SRI 53-00-13-2-001-00 TABLE 205. 1ST INSPECTION DUE AT 6SDR CALA2014090392056Stringer · corrodedSTRINGER 41L IS CORRODED BETWEEN FRAME 63 - 64 IN AFT CARGO PIT. REMOVED DAMAGED SECTION. FABRICATED & INSTALLED STRINGER & REPAIR SPLICE IAW SRM 53-00-13 FIG 201. REPAIR REQUIRES SRI INSPECTIONS IAW SRI 53-00-13-2-001-00 TABLE 205. 1ST INSPECTION DUE AT 6SDR CALA2014090392055Stringer · corrodedSTRINGER 42L IS CORRODED BETWEEN FRAME 63 - 64 IN AFT CARGO PIT. REMOVED DAMAGED PART. FABRICATED & INSTALLED NEW STRINGER & REPAIR SPLICE IAW SRM 53-00-13 FIG 201.SDR CALA2014090392054Threshold · corrodedL2 DOOR THRESHOLD BEAM CORRODED AT FRAME 68 IN AFT CABIN. CORROSION AROUND 2 NUTPLATES WAS EXFOLIATED. CUT OUT DAMAGED PART & INSTALLED REPAIR PARTS IAW SRM 53-11-14 PG 203 PARA 5 FIG 201.SDR CALA2014090392049Battery · dischargedEMERGENCY LIGHT FAIL LT EPSM. REPLACED LT ESPM BATTERY, CHECKED OK.SDR YENA20140830172Wire · brokenDURING MAINTENANCE EMERGENCY EXIT LIGHT AT SEAT 11C FOUND INOPERATIVE. TROUBLESHOT TO A BROKEN WIRE ALONG THE BULKHEAD ON THE FLOOR AT THAT ROW. REPLACED HARNESS AT 11C IAW 33-51-00, OPERATION NORMAL. HARNESS WAS TAKEN FROM POSITION 15C WHICH WAS DEFERRED USDR USAA2014090300007Fuel Door · corrodedS2 CHECK LEVEL 2 FRETTING CORROSION ON LT WING LOWER FUEL DOOR 540AB BETWEEN WING RIBS 2 & 3, ALSO BETWEEN STRINGERS 8L TO 11L. REPLACED LT WING LOWER FUEL DOOR 540AB IAW SRM 57-27-11.SDR USAA2014090200028Cover · missingENTRY DOOR L1 LOWER LEVEL EXIT LIGHT COVER MISSING. INSTALLED EMER EXIT LIGHT COVER AT L1 DOOR.
Back to Airbus A320-232