Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA20140808150Battery Pack · no testDURING MAINTENANCE, EMERGENCY LIGHT FAILED TEST. R & R BATTERY PACKS AT 12WL. EMERGENCY LIGHTS CHECKS GOOD IAW AMM 33-51-38.SDR YENA20140808149Battery · failedDURING MAINTENANCE CHECK, FOUND AFT LT EMERGENCY LIGHT BATTERY FAILED. R & R EMERGENCY BATTERY FIN 13WL IAW 33-51-38. OPS CHECKED GOOD.SDR CALA2014081391960Stringer Splice · corrodedFORWARD CARGO PIT STRINGER SPLICE ON STRINGER 41R BETWEEN FRAME 30 - 31 CORRODED. STRINGER SPLICE REPLACED IAW SRM 51-42-11 & 51-44-11.SDR USAA2014080800004Gust Lock · dirtyDOOR L1 GUST LOCK INOPERATIVE. CLEANED & LUBED DOOR L1 GUST LOCK ASSEMBLY. OPERATIONS CHECKED NORMAL.SDR CALA2014081191934Light · malfunctionedRIGHT SIDE FLIGHT DECK DOME LIGHT INOPERATIVE ON BATTERY POWER. CYCLED SIDES 1 & 2, ACP LIGHT TESTED OK.SDR CALA2014081191932Landing Gear · low pressureLANDING GEAR WOULD NOT RETRACT WHEN HANDLE SELECTED UP. FAULTING NLG EXTEND PROX SENSORS 24GA & 25GA. CHARGED NLG NITROGEN PRESS IAW AMM 12-14-614-004A.SDR YENA20140806148Outflow Valve · failedVENT SKIN VALVE EXTRACT AFFECTED, DIVERTED. ASSOCIATED WITH BLOWER FAULT. R & R AIR OUTLET SKIN VALVE IAM AMM 21-26-53. AVEC TEST OK AND FAULT CLEARED.SDR USAA2014080600016Battery · dischargedEMERGENCY FLASHLIGHT AT FWD FLIGHT ATTENDANTS JUMP SEAT INOPERATIVE. REPLACED BATTERY IN EMER FLASHLIGHT.SDR CALA2014080691739Warning System · false activationAT GATE WITH NO ENGS RUNNING. ENG 2 FAIL ECAM. ACCOMPLISHED TSM 73-00-00 -810-856-A NO HELP. CHECKED FDEC 2A & 2B GND REPORTS & SELF-TEST BOTH TESTS NORMAL WITH NO FAULTS. CYCLED NR 2 ENG FIRE SWITCH, NO HELP. DEPOWERED ACFT & REPOWERED, MSG CLEARED. RANSDR USAA2014080500003Damper · obstructedSHEAR PIN HOLE ON OTBD SIDE OF R2 DOOR DAMPER IS OBSTRUCTED. REPLACED R2 DOOR DAMPER CYLINDER IAW AMM 52-13-14.SDR CALA2014080691740Slide · faultedEPSU 10WL DOOR 1R FAILED WITH EXTERIOR LIGHTS FAULT. REPLACED SLIDE ASSEMBLY DUE TO EXTERNAL LOAD FAULT DOOR 1R IAW 25-62-44.SDR GTIA2014080101395Bottle · low pressureR2 DOOR ASSIST BOTTLE HAS LOW PRESSURE. R2 DOOR ASSIST BOTTLE SERVICED TO PROPER PRESSURE IAW AMM 52-10-00.SDR YENA20140731145Power Supply · failedDURING MAINTENANCE IT WAS DISCOVERED EPSU EXT LOAD EMERGENCY RT AND EPSU EXT LOAD LT FAILURE MESSAGES FOR EMERGENCY LIGHT SYS CHECK. R & R LT, 10WL, EPSU IAW AMM 33-51-38 . REMOVED AND INSTALLED EPSU AT 12WL. PERFORMED OPS TEST OF EMERGENCY LIGHTS IAW AMM 3SDR GTIA2014073101392Oxygen Mask · damagedOBSERVER`S OXYGEN MASK IS MISSING A RETAINING CLIP. R & R OBSERVER OXYGEN MASK IAW AMM 35-12-41-000-002-A/400-001-A, OPS CHECKED GOOD.SDR USAA2014080100009Battery · dischargedAFT EMER FLASHLIGHT INOPERATIVE. REPLACED BATTERY IN AFT EMER FLASHLIGHT.SDR USAA2014080100008Lens · missingEMERGENCY AISLE LIGHT LENS COVER IS MISSING. REPLACED EMER AISLE LIGHT LENS COVER.SDR USAA2014073100005Cover · missingDOOR 2L EMER EXIT SIGN COVER MISSING. REPLACED DOOR 2L EMER EXIT SIGN COVER.SDR CALA2014080191585Engine · making metalMETAL FOUND IN TAIL PIPE AFTER ENG 2 HAD 3 SELF-RECOVERING STALLS IN CRUISE. REPLACED NR 2 ENG IAW MT 71-017. ENG RUNS & OPERATIONS CHECKED.SDR USAA2014073000007Bottle · low pressureR1 DOOR ASSIST BOTTLE NEEDS SERVICING. SERVICED NITROGEN PRESS ON R1 DOOR ASSIST BOTTLE AS REQUIRED.SDR YENA20140729143Fmu · failedCREW DECLARED AN EMERGENCY AND ACFT RETURN TO DEPARTURE. ENG 1 STALL, ECAM & LOSS OF THRUST CLIMBING 12000/300KTS. ENG 1 DECREASED TO IDLE THRUST: EGT 440 N2-59 PERCENT, EPPR .927 EF 700 N1-25 PERCENT THRUST DID NOT INCREASE WITH THROTTLE ADVANCEMENT, GEN 1 SDR USAA2014072900003Flashlight · inoperativeINBOARD FWD EMER FLASHLIGHT INOPERATIVE. REPLACED FWD INBD EMER FLASHLIGHT IAW AMM 25-65-52-00-400-001-A.SDR CALA2014072891554Door Frame · corrodedRIGHT FWD EMER EXIT FOUND CORROSION OUT OF LIMITS INTERNAL DOOR FRAME LOWER BAYS. R & R PN D5227902820600, D5227905420400 & D5227902820451 IAW SRM 51-4 2-11. NO FURTHER INSPECTIONS REQUIRED AT THIS TIME.SDR USAA2014072800010Girt Bar · out of adjustARMED HANDLE R2 WOULD MOVE TOWARD OPEN DURING FLIGHT CAUSING A DOOR ECAM MSG. CLEANED & ADJUSTED GIRT BAR.SDR CALA2014072891553Stringer · corrodedCORROSION FOUND INTERNAL BILGE FRAME 31 - 32 STRINGER 41R. MORE THAN 50% MATERIAL LOSS. CORROSION REMOVED & INSTALLED REPAIR IAW SRM 53-21-13 TABLE 202 PARAGRAPH 5 A FIG 202 SHEETS 2-4. REINSPECT AT 60000 PTC IAW SRI 53-21-13-2-002-00. REPAIR APPLIED TO STSDR CALA2014072891552Skin · corrodedADF ANTENNA CUT OUT FOUND CORRODED FUSELAGE FRAME 44 - 45 STRINGER 1L - 1R. REMOVED CORROSION FROM UPPER SKIN SURFACE NEAR ADF CUT OUT.\O-T\0.087. DEPTH OF REMOVED MATERIAL =.077\W=2.5\ SRM 53-31-11 PARAGRAPH 3 TABLE 101 PARAGRAPH 4 A NOTE 1 DIAGRAM 101. ACSDR CALA2014072891551Structure · corrodedLEFT FWD EMER OVERWING DOOR STRUCTURE FOUND CORROSION IN BOTTOM 3 BAYS. R & R PN`S D52279028206, D52279028204, D52279054202 & D52279055200 IAW SRM 51-42-11. NO FURTHER ACTION NECESSARY.SDR CALA2014072891550Structure · corrodedLEFT AFT EMER EXIT OVERWING DOOR FOUND CORROSION ON STRUCTURE LOWER BAYS. R & R PN`S D52279055203, D5227905204 & D52279055202 IAW SRM 51-42-11. NO FURTHER ACTION NECESSARY.SDR CALA2014072891549Door · corrodedRIGHT AFT EMER EXIT OVERWING DOOR CORROSION FOUND ON STRUCTURE LOWER 3 BAYS. R & R PN D5227902820451, D5227902820600 & D5227905420400. NO FURTHER ACTION NECESSARY.SDR CALA2014072891548Skin · damagedMLG DOOR HINGE FITTINGS LT & RT WERE REMOVED TO FIND SEVERAL ELONGATED HOLES AT MATING SURFACE OF HINGE FITTING & KEEL BEAM BOTTOM SKIN. REPAIRED BOTH LT & RT BOTTOM KEEL BEAM SKINS AT HINGE FITTING SURFACES IAW ECRA 5336-01 017. NO DEVIATIONS, NO FURTHER ACSDR USAA2014072800013Cylinder · low pressureR2 DOOR ASSIST LOW PRESS INDICATION. SERVICED R2 DOOR ASSIST TO PROPER PRESS.SDR USAA2014072800012Cover · brokenEMERGENCY EXIT SIGN COVER AT ROW 26C BROKEN. REPLACED EMER EXIT SIGN COVER AT ROW 26C.SDR USAA2014072800008Slide · crackedLEFT OVERWING SLIDE AFT LOWER CORNER IS CRACKED. REPLACED LT OVERWING SLIDE IAW AMM 25-62-42-400-001.SDR YENA20140724191Slide · misrepairedDISCREPANCY ON THE OVERWING SLIDE. DURING THE SCHEDULED RESTORATION OF OVERWING SLIDE, IT WAS FOUND THAT A VACUUM ADAPTER TOOL WAS STILL ATTACHED TO THE SLIDE ASPIRATOR. TOOL SHOULD HAVE BEEN REMOVED DURING THE FOLDING/PACKING PROCESS.SDR USAA2014072500007Control Servo · defectiveMODERATE VIBRATION FELT ALL THROUGH THE ACFT THAT LASTED 20 SECONDS DURING CLIMB THROUGH 29000. REPLACED THE GREEN SYS ELEVATOR SERVO CONTROL ACTUATOR IAW AMM 27-34-51-000.SDR USAA2014072500006Lens · missingEMERGENCY LIGHT LENS IS MISSING AT SEAT 9D. REPLACED EMER LIGHT LENS AT SEAT 9D.SDR USAA2014072400003Lens · looseSEAT 1C EXIT LIGHT LENS LOOSE. REPLACED LENS.SDR USAA2014072400002Light · crackedAFT DOOR EMERGENCY EXIT LIGHT IN AISLE CRACKED. REPLACED EMERGENCY LIGHT HOUSING ASSEMBLY 52WL IAW AMM 33-51-17-0401.SDR YENA20140722139Probe · failedCLIMBING THRU 3000' RECEIVED AN ECAM CAUTION ANTI-ICE CAPT LT STAT WITH AN ASSOICIATED ELECTRICAL OVERHEAT ODOR. SWITCHED TO ADR CAPT 3 IAW ECAM & ODOR QUICKLY DISSIPATED. FOUND ON PFR PHC NR 1 FAULTING, ON GROUND SCAN PH1 POWER SUPPLY. R & R PHC 1 IAW AMM 3SDR USAA2014072300004Power Supply · inoperativeCEILING EMER LIGHTS AT ROWS 1 & 8 INOPERATIVE. REPLACED EMER POWER SUPPLY UNIT 10WL IAW AMM 33-51-38.SDR USAA2014072300003Lens · brokenL2 DOOR AFT BOTTOM EXIT SIGN HAS BROKEN LENS. REPLACED EXIT SIGN LENS AT LOWER AFT L2 DOOR.SDR CALA2014072591515Stringer · corrodedMAJOR REPAIR. STRINGER 42L CORROSION REPAIR ACCOMPLISHED BETWEEN FRAME 57 - 59. STRINGER SPLICE REPAIR REQUIRES INSPECTION AT 60,000 FLIGHT CYCLES AFTER REPAIR EMBODIMENT. DAMAGE WAS REMOVED & NDT ACCOMPLISHED IAW NTM51 -10-08. NO CRACKS FOUND. THE REPAISDR CALA2014072591513Door Sill · corrodedMAJOR REPAIR. R2 DOOR SILL AFT END CORRODED. BLENDED CORROSION ON AFT END OF DOOR SILL. AFTER BLENDING AFT SECTION MEASURED 0.030 & FWD SECTION MEASURED 0.042. ORIGINAL THICKNESS = 0.070. MAX MATERIAL LOSS ALLOWED =0.017. R & R RT 2 DOOR SILL.SDR USAA2014072200007Battery · dischargedFORWARD OTBD FLASHLIGHT INOPERATIVE. REPLACED BATTERY IN FWD OTBD FLASHLIGHT.SDR YENA20140721136Battery Pack · failedDURING MAINTENANCE CHECK, FOUND EMERGENCY LIGHT POWER SUPPLY TO FAIL TEST. R & R BATTERY PACK IAW AMM 33-51-00, OPS CHECKED GOOD.SDR CALA2014072291505Door · gougedMAJOR REPAIR. RT LATERAL AVIONICS COMPARTMENT DOOR GOUGED AT HANDLE CUT OUT ADJACENT TO RELEASE PUSH BUTTON. BLENDED MINOR DAMAGE. DIMENSIONS AFTER BLENDING ARE AS FOLLOWS E=.4 D=.159 E BY D= 2.515 >1.5. WITHIN LIMITS IAW SRM 52-41-00 FIG 101 SH 2. THIS RSDR CALA2014072291504Door · gougedMAJOR REPAIR. LEFT LATERAL AVIONICS COMPARTMENT DOOR HANDLE CUT OUT GOUGED ADJACENT TO HANDLE RELEASE PUSH BUTTON. REPAIRED MINOR GOUGE. AFTER BLENDING DIMENSIONS ARE AS FOLLOWS. E=.4 D = .159 E BY D = 2.515 > 1.5. WITHIN LIMITS IAW SRM 52-41-00 FIG 101 SHSDR CALA2014072291503Door · gougedMAJOR REPAIR. AFT AVIONICS COMPARTMENT DOOR HANDLE CUT OUT GOUGED ADJACENT TO HANDLE RELEASE PUSH BUTTON. BLENDED MINOR DAMAGE. DIMENSIONS AFTER BLENDING ARE AS FOLLOWS. E=.3 D=.159 E BY D =1.886 > 1.5. WITHIN LIMITS IAW SRM 52-41-00 FIG 101 SH 2. THIS RESDR CALA2014072291502Cleat · corrodedFORWARD PIT CLEAT CORRODED AT BETWEEN FRAMES 27 & 28 AT STRINGER 38L. REPLACED CLEAT IAW SRM 51-42-11 PAGE 23 & 24.SDR CALA2014072291501Door · gougedMAJOR REPAIR. FWD AVIONICS COMPARTMENT DOOR HAS GOUGE AT HANDLE CUT OUT ADJACENT TO PUSH RELEASE BUTTON. REWORKED DAMAGED AREA & REMOVED DAMAGE IAW SRM 52-41-00 PG 107 FIG 101 SH 2. REWORKED AREA IS IN ZONE 1 E BY D =2.51 > 1.5. HFEC REVEALED NO CRACKS. MASDR CALA2014072291500Stringer Splice · corrodedFORWARD CARGO HAS CORRODED STRINGER SPLICES AT FRAME 31 - 30 STRINGER 41L - 42R. REPLACED STRINGER SPLICES AT FRAME 30 - 31 STRINGER 41 LT - 42 RT.
Back to Airbus A320-232