Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014072291499Shear Tie · corrodedFORWARD CARGO COMPARTMENT SHEAR TIE CORRODED AT FRAME 33. REPLACED CLEAT AT FRAME 33 STRINGER 40 RT.SDR CALA2014072291498Shear Tie · corrodedFORWARD CARGO HAS CORRODED SHEAR TIE AT FRAME 32. REPLACED SHEAR TIE AT FRAME 32 STRINGER 42 RT.SDR CALA2014072291497Shear Tie · corrodedFORWARD PIT FRAME 30 SHEAR TIES CORRODED. REPLACED SHEAR TIES AT FRAME 30 STRINGER 44 LT & 44 RT IAW SRM 57-42-11 PG 29.SDR CALA2014072191480Battery · dischargedAFT EPSU FAIL EMER LIGHT TEST FOUND BATTERY WOULD NOT STAY CHARGED. REPLACED BATTERY AMM 33-51-38, GND CHECKED NORMAL.SDR CALA2014072191479Power Supply · inoperativeLEFT EPSU FAILED EMER LIGHT TEST. FOUND PSU INOPERATIVE. REPLACED IAW AMM 33-50-51, GND CHECKED NORMAL.SDR USAA2014072100006Warning System · false indicationAIRCRAFT RETURNED TO FIELD DUE TO LG WOULD NOT FULLY RETRACT AT 215KTAS. ECAM LG NOT UPLOCKED. OPERATED GEAR DOWN TO EXPEDITE FUEL BURN DOWN TO MAX LAND WEIGHT. PERFORMED TSM 32-31-00-810-808-A COMPLIED WITH LG FUNCTION TEST NORMAL, EXTRACTED & RETRACTED 10SDR USAA2014072100004Power Supply · inoperativeCABIN EMER LIGHT SYS FAILED OPERATIONS CHECK. REPLACED POWER SUPPLY UNIT 12WL IAW AMM 33-51-00.SDR CALA2014071591476Door Sill · corrodedR1 DOOR SILL SHOWS EVIDENCE OF CORROSION AT GIRT BAR FITTING HARD MOUNTS. FWD QTY 4 & AFT QTY 2. DAMAGE FOUND WITHIN ALLOWABLE RE-WORK LIMITS IAW SRM 53-11-14 PARA 3 TABLE 101. RE-WORK ACCOMPLISHED IAW SRM 53-11-14 PARA 4 E FIG 108 SHEETS 1 - 5. FIRST REQUSDR CALA2014071591475Door Sill · corrodedL1 DOOR SILL SHOWS EVIDENCE OF CORROSION AT FWD & AFT GIRT FITTING HARD MOUNTS. QTY 2 FWD & QTY 1 AFT. DAMAGE FOUND WITHIN ALLOWABLE REWORK LIMITS IAW SRM 53 -11-14 PARA 3 TABLE 101. REWORK ACCOMPLISHED IAW SRM 53-11-14 PARA 4 E FIG 108 SHEETS 1 - 5. FIRSTSDR CALA2014071591474Beam · corrodedDOOR 2L SILL BEAM CORRODED AT FASTENER HOLES FOR FWD GIRT BAR FITTING. REMOVED CORROSION & INSTALLED REPAIR IAW SRM 53-41-14 FIG 201. THIS IS A CATEGORY A REPAIR.SDR USAA2014071500008Computer · faultyAFTER TAKEOFF CREW RECEIVED A CAUTION FLIGHT CONTROL FLAPS LOCKED, WING TIP BRAKE ON SLAT SYS 1 FAULT. THE CAPTAIN ELECTED TO RETURN & THE FLIGHT DECLARED AN EMER LANDED WITHOUT FULL FLAPS & TAXIED TO THE GATE. CFR EQUIPMENT DID RESPOND. REPLACED SFCC NR 1SDR CALA2014071591467Spar · wornNUMBER 1 PYLON LOWER SPAR HAD WEAR SPOT FROM CONTACT WITH THE CNA AT RIB 5. THE BLEND OUT IS .019 INCHES DEEP & 0.400 INCHES WIDE. AN ANTI-CHAFE PLATE WAS INSTALLED IAW SRM 54-51-12 PARA 5 B FIG 202. REQUIRES RE-INSPECTION IAW SRI 54-51-12-2-001-00 PARA 3 ASDR CALA2014071591466Spar · wornNUMBER 2 PYLON LOWER SPAR HAD WEAR SPOT FROM CONTACT WITH THE CNA AT RIB 5. THE BLEND OUT IS .003 INCHES DEEP & 0.100 INCHES WIDE. AN ANTI-CHAFE PLATE WAS INSTALLED IAW SRM 54-51-12 PARA 5 B FIG 202. REQUIRES RE-INSPECTION IAW SRI 54-51-12-2-001-00 PARA 3 ASDR CALA2014071591465Skin · damagedDOUBLER REPAIR ACCOMPLISHED ON EXTERNAL FUSELAGE SKIN JUST AFT OF FRAME 1 & AT Y-330 RT. ORIGINAL SKIN THICKNESS 0.055INCHES. REPAIR ACCOMPLISHED IAW SRM 53-00-11 TBL 203 PARA 4 W FIG 239. REPAIR REQUIRES INSPECTION IAW SRI 53-00-11-2-017-00 PARA 3 L TBL 22SDR YENA20140712131Battery · failedDURING MAINTENANCE CHECK, FOUND EMERGENCY LIGHTS TEST SHOWS INTERIOR AND EXTERIOR LOAD FAULT. REPLACED EPSU 13WL AND BATTERY IAW AMM 33-51-38. OPS CHECK GOOD.SDR YENA20140712130Power Supply · failedDURING MAINTENANCE CHECK, FOUND EMERGENCY LIGHTS TEST SHOWS INTERIOR AND EXTERIOR LOAD FAULT. REPLACED EPSU 13WL AND BATTERY IAW AMM 33-51-38. OPS CHECK GOOD.SDR CALA2014071591463Stringer · corrodedSTRINGER FOUND CORRODED BETWEEN FRAME 58 & 60. STRINGER SECTION REPLACED FROM FRAME 58 TO 64.SDR CALA2014071591462Stringer Splice · corrodedSTRINGER 41R SPLICE PLATE CORRODED AT FRAME 58. R & R STRINGER SPLICE PLATES.SDR USAA2014071400013Seat Back · brokenEMERGENCY EXIT SEAT 10C SEAT BACK BROKEN. REPLACED SEATBACK ASSEMBLY AT SEAT 10C.SDR CALA2014071191442Computer · malfunctionedFMGC NR 1 INOPERATIVE. R & R NR 1 FMGC IAW MM 22-83-34-000-001-A & 22-83-34-400-001-G. PERFORMED OPERATIONS TEST OF LAND CAT III CAPABILITIES IAW 22-97-00-710-001-A. LAND TEST PASSED, ACFT REMAINS FULLY CAT CAPABLE.SDR GTIA2014070901379Oxygen Mask · leakingCAPTAIN`S OXYGEN MASK HEAD BAND LEAKS. R & R OXYGEN MASK IAW AMM 35-12-41 PB 401. OPS CHECKED GOOD. NO FURTHER DEFECTS FOUND.SDR GTIA2014070901378Bottle · low pressureL2 DOOR ASSIST BOTTLE HAS LOW PRESSURE. SERVICED L2 DOOR ASSIST CYLINDER AMM -52-10-00.SDR CALA2014071191448Mechanism · lack of lubeON TAXI, ENG 1 EGT BEGAN PULSING AMBER THEN RED. EGT OBSERVED AT 642, SHUTDOWN ENG, DURATION WAS 10 SECONDS. FOLLOWED FAILURE MSG IAW AMM75-32-42. LUBRICATED THE VSV MECHANISM IAW AMM75-32-42-640 -010. ALSO REPLACED THE HP COMPRESSOR SOLENOID VLV 7A IAW 75SDR CALA2014071191446Control System · malfunctionedHOT AIR FAULT DISPLAYED ON UPPER ECAM SCREEN. RESET PACK CONTROL SYS 1 & 2 PACKS, FAULT CLEARED.SDR CALA2014071191445Structure · crackedRIGHT WW SIDE BOX FLANGE CRACKED AFT SIDE OF FASTENER JUST FWD OF FRAME 43. REPAIRED RT WW SIDE BOX FLANGE CRACK IAW ECRA 5330-04874. NO SRI INSPECTION IS REQUIRED IAW ECRA.SDR CALA2014071191444Beam · crackedLEFT MLG WW SIDE BOX BEAM FLANGE CRACKED AFT SIDE OF FASTENER, JUST FWD OF FRAME 43. REPAIRED THE CRACK ON LT WW SIDE BOX BEAM FLANGE JUST FWD OF FRAME 43 IAW ECRA 5330-04874. NO SRI INSPECTION REQUIRED IAW ECRA.SDR GTIA2014070801376Bottle · low pressureR1 DOOR ASSIST CYLINDER HAS LOW PRESSURE. SERVICED R1 DOOR ASSIST CYLINDER AMM-52-10-00.SDR USAA2014070900004Power Supply · failed2S CHECK ESPU 12WL AT RT OVERWING EXITS FAILS SELF-TEST. REMOVE, REPLACE & ACCOMPLISHED A SATISFACTORY TEST OF ESPU 12WL IAW AMM 33-51-38.SDR CALA2014071191447Stringer · corrodedAFT CARGO COMPARTMENT BILGE AREA FRAME 60 - 64 RT HAS CORROSION. AFT CARGO STRINGER 42R CORRODED BEYOND LIMITS. FRAME 60 - 64 REPAIRED BY SPLICING IN NEW STRINGER SECTION SRM 53-00-13 FIG 202. THIS SRM REFERS TO SRI 53-00-13 TBL 205 PG 205. RE-INSP AT 6000SDR CALA2014071191443Bonding Strap · damagedBOTH LT & RT WING FUEL TANKS ALL ELEC BONDING CABLES SHOWS SIGNS OF AGEING & BRITTLENESS. ACCOMPLISHED LT WING FUEL TANK ALL BONDING WIRE REPLACEMENT.SDR GTIA2014070701375Oxygen Mask · unwanted deployOXYGEN MASK DEPLOYED AFTER PARKING ROW 18 ABC. ACCOMPLISHED PACKING OF THE OXYGEN MASK ASSY IAW AMM TASK 35-21-43-550-801-A, ACCOMPLISHED OPS CHECK OF MANUAL MASK RELEASE IAW AMM TASK 35-23-00-710-001-A. ACFT OK FOR SERVICE.SDR GTIA2014070701374Flashlight · inoperativeFWD F/A FLASHLIGHT INOPERATIVE. R & R FWD OTBD EMERGENCY FLASHLIGHT IAW CMM 25-60-13.SDR USAA2014070900005Lens · broken2S CHECK RED EMER EVACUATION SYS FLOOR LEVEL EXIT MARKER WAS BROKEN AT LAVATORY D ON AFT BULKHEAD. REPLACED RED EMER EVACUATION SYS FLOOR LEVEL EXIT MARKER AT LAVATORY D ON AFT BULKHEAD IAW AMM 33-51-18-400-001-A.SDR USAA2014070800005Slide · worn2S CHECK RT OVERWING ESCAPE SLIDE CTR DOOR LOCK MECHANISM, WORN & NOT HOLDING DOOR FLUSH AGAINST SLIDE ENCLOSURE. REPLACED SLIDE IAW JOB CARD 26C19053012.SDR YENA20140707128Seal · leakingAIRCRAFT DIVERTED, THE CREW RECEIVED AN ADVISORY ECAM ON PRESS PAGE, STOP CLIMB A FEW SECONDS LATER. CABIN PRESSURE CLIMB TO 11,000, EMERGENCY DESCENT INITIATED AT 15,000 CAB PRESSURE NORMAL. R & R AFT CARGO DOOR SEAL IAW AMM 52-32-18 PRESSURIZED ACFT NO LEASDR CALA2014071191426Warning Light · illuminatedCOCKPIT DOOR FAULT LIGHT & DOOR CONTROLLER TOP STRIKE OR LOWER STRIKE LIGHT IS ON. LOWER STRIKE LIGHT ON RESET COCKPIT DOOR CB & PERFORMED OPERATIONAL TEST IAW AMM 52-51-00. OPERATIONS CHECKED OK.SDR CALA2014071191424Stringer · corrodedAFT CARGO STRINGER 39 RT CORROSION ON OUTER FLANGE BETWEEN FRAME 62 - 63 & STRINGER 39. REMOVED CORROSION STRINGER 39 AFT CARGO FRAME 62 - 63 IAW SRM 53-00-13 FIG 202. HFEC ACCOMPLISHED NO CRACKS NOTED IAW NTM 51-10-04. INSTALLED REPAIR IAW SRM53-00-13 FIG SDR CALA2014071191423Stringer · corrodedAFT CARGO COMPARTMENT BILGE AREA STRINGER FRAME 61 - 64 STRINGER 40 RT HAS CORROSION. OUT OF LIMITS REPAIR EXTENDS PASSED 2 BAYS IAW SRM 53 -41-13 & 53-00-13 FIG 202 SHEET 2. REMOVED DAMAGED STRINGER 40 FRAME 61 - 64 APPROX 51.25 INCHES SRM53-00-13 FIG 202. SDR CALA2014071191422Access Panel · gougedLEFT WING FUEL PANEL 540MB HAS TWO EACH GOUGED FASTENER S HOLES. REAMED TWO EACH HOLES ON PANEL 540MB, COLD WORKED HOLES & REAMED. FABRICATED TWO BUSHINGS & INSTALLED ON PANEL. BRIDGE PLATE INSTALLED WET IAW SRM 57-21-11 PARA 5 B FIG 202. PANEL REQUIRES RESDR GTIA2014070601373Bottle · low pressureR2 DOOR BOTTLE HAS LOW PRESSURE. SERVICED R2 DOOR ASSIST BOTTLE IAW AMM 52-12-14 LEAK CHECKED GOOD.SDR USAA2014070700022Panel · crackedSPEED BREAK SURFACE PANEL CRACKED. R & R SPEED BREAK SURFACE PANEL, OPEN. PN, SN & LOCATION INFORMATION TO FOLLOW.SDR CALA2014071191429Skin · scratchedEXTERIOR FUSELAGE SKIN HAS SCRATCH JUST BELOW AOA VANE MOUNT PLATE. BLENDED SCRATCH ON LT FUSELAGE SKIN, 6.5 INCHES FWD OF FRAME 24 ABOVE SKIN LAP AT STRINGER 28 IAW SRM 51-73-00 PARA F PG 5. HFEC REVEALED NO CRACK INDICATION.SDR CALA2014071191425Control Unit · malfunctionedNUMBER 2 GENERATOR WILL NOT COME ON LINE, LOW VOLTS. ACCOMPLISHED NR 2 IDG CONTROL UNIT RESET IAW TSM -24-22-00-810-818. RAN BOTH ENGS PERFORMED LOAD SHED ON AC BUS, NR 2 ENG IDG OPERATIONS CHECKED NORMAL.SDR CALA2014071191421Door Sill · corrodedR2 DOOR SILL HAS CORROSION FRAME 66 & STRINGER 23R. BLENDED CORROSION ON R2 DOOR SILL BEAM OUT OF LIMITS IAW SRM51-41-14 FIG 101. R & R BEAM IAW SRM 51-42-11 PAGES 6 - 7.SDR CALA2014071191420Fitting · crackedFRAME 43 WING BAY CORD, TORSION BOX & MLG FREE FALL BRACKET AFT HOLE HAS A CRACK RT SIDE. R & R LT & RT REINFORCEMENT FITTINGS TORSION BOX LOWER SIDE SHELL.SDR CALA2014071191419Stringer · corrodedSTRINGER 42L CORRODED IN AFT PIT AFT OF FRAME 56. REMOVED CORRODED SECTION OF STRINGER & REPLACED WITH A NEW STRINGER. FABRICATED NEW STRINGER SPLICE & INSTALLED. REPAIR REQUIRES SRI INSPECTION. FIRST INSPECTION DUE AT 60000FC & 75000FH AFTER REPAIR EMBODIMSDR CALA2014071191418Stringer · corrodedSTRINGERS 41L & 42L CORRODED IN AFT CARGO COMPARTMENT BETWEEN FRAME 63 & 64. REMOVED CORRODED SECTIONS OF STRINGERS & REPLACED WITH NEW STRINGERS. FABRICATED NEW STRINGER SPLICES & INSTALLED. REPAIR REQUIRES RE-INSPECTION. FIRST INSPECTION DUE AT 60000FC ASDR CALA2014071191417Stringer · corrodedAFT CARGO JUST AFT OF FRAME 56 STRINGER 40 CORROSION STRINGER. REMOVED DAMAGED SECTION OF STRINGER 40L & FRAME 56. FABRICATED & INSTALLED STRINGER SPLICE REPAIR. REPAIR HAS SRI AT 60000 FC & 7500 WITH SUBSEQUENT INSP & METHOD TBD.SDR CALA2014071191413Ils System · faultedILS 2 FAULT DISPLAYED ON UPPER ECAM SCREEN. ACCOMPLISHED CHRONIC REVIEW. ACCOMPLISHED MT 34-001. OPERATIONS CHECKED GOOD.SDR YENA20140705125Wire Harness · damagedDURING A MAINTENANCE CHECK, FOUND ROW 15ABC EMERGENCY LIGHT INOPERATIVE. REPLACED WIRE HARNESS IAW CMM 25-25-15. CHECKED NORMAL.
Back to Airbus A320-232