Airbus A320-232
Service difficulty reports · 32,653
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'A320232' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014041090796Sill · corrodedR2 DOOR SILL IS CORRODED ON FWD GIRT BAR PLATE & AT AFT AREA. DOOR SILL WAS WORN OUT OF LIMITS IAW SRM 53-41-11. R & R R2 DOOR SILL IAW SRM 51-42-11 PGS 1, 7 & 25.SDR YENA20140409075Control Unit · intermittentDECLARED AN EMERGENCY DUE TO BRAKE SYS 2 INOPERATIVE, NORMAL BRAKE INOPERATIVE. FAULT CLEARED DURING TAXI. PERFORMED SYSTEM RESET AND BITE TEST OF BSCU IAW AMM 32-46-00. NO FAULTS FOUND. SYS TEST NORMAL OK FOR SERVICE. P1 TSI 11706 WAS ALSO ASSIGNED TO REMSDR YENA20140409072Pressure Switch · failedDECLARED AN EMERGENCY AND ACFT RETURNED TO DEPARTURE, FOR A HYD GREEN RESERVOIR LOW AIR PRESSURE ECAM DURING CRUISE. GREEN, ENG 1, PUMP FAULT LIGHT & PTU FAULT LIGHT ON. COMPLIED WITH ECAM OR QRH PROCEDURES. ON DESCENT TURNED ENG 1 PUMP ON TO RESTORE GREEN SYSSDR GTIA2014040801256Slide · low pressureR2 PAX DOOR SLIDE LOW PRESSURE. R & R SLIDE IAW AMM 25-62-44-00-012-A & 25-62-44-400-007-A. OPS CHECKED GOOD IAW AMM 33-51-710-001-A.SDR YENA20140407073Tube · failedDURING TAKEOFF ROLL NR 1 ENGINE LOST APPROXIMATELY 15 TO 20 PERCENT POWER. CREW CONTINUED TAKEOFF, DECLARED AN EMERGENCY AND ACFT RETURNED TO DEPARTURE. FOUND RT P4.9 PRESSURE TUBE SEVERED. R & R IAW AMM 73-22-51.SDR CALA2014040890772Wire · damagedREF 2 SVC EMERGENCY LIGHTS OPERATIONAL TEST MSG DISPLAYED WHEN TEST FAILED. ATA 33-51-38 EXT LOADS FWD L. TESTED AT EPSU, STILL FAILED. ALSO FAILED WITH TESTER CONNECTED AT EACH FWD SLIDE. RANG WIRING FROM 2871VC ON DOOR 1L TO GND & NO GND FOUND. BETWEEN SDR GTIA2014040701255Handle · damagedL1 DOOR ASSIST HANDLE DAMAGED. R & R L-1 DOOR ASSIST HANDLE IAW AMM 25-23-46PB401. OPS CHECK GOOD.SDR GTIA2014040701254Knob · missingFWD MEGAPHONE MISSING VOLUME KNOB. R & R FWD MEGAPHONE IAW INTERIOR NK320-232-EQ.SDR USAA2014040800005Pin · brokenUPON REMOVAL FOR INSPECTION FOUND NLG TORQUE LINK PIN BROKEN. REPLACED NLG TORQUE LINK CTR PIN IAW JOB CARD 26C71032003.SDR YENA20140407070Proximity Sensor · failedAIR RETURN TO DEPARTURE DUE TO AFT CARGO DOOR INDICATOR OPEN IN FLIGHT. R & R AFT CARGO DOOR PROXIMITY SENSOR IAW TSM 52-32-00-810-801. ADJUSTED AS REQUIRED. OPS CHECKED OK. ALL INDICATIONS NORMAL.SDR CALA2014040890774Skin · saturatedLEFT ELEVATOR UPPER SKIN PANEL HAS TRAPPED WATER INDICATION 145 INCHES FROM INBD END & 14 INCHES FROM TE, 1 INCH DIAMETER. REPAIRED LT ELEVATOR UPPER SKIN AT AREA NOTED. DRILLED WITNESS HOLES & FOUND WATER. CUT OUT & REMOVED WATER, APPLIED REPAIR & RESTOREDSDR CALA2014040890773Skin · saturatedLEFT ELEVATOR UPPER SKIN HAS A TRAPPED WATER INDICATION 143 INCHES FROM INBD END & 17 INCHES FROM TE, 1 INCH DIAMETER. REPAIRED LT ELEVATOR UPPER SKIN AT AREA NOTED. DRILLED WITNESS HOLES & FOUND WATER. CUT OUT & REMOVED WATER, APPLIED REPAIR & RESTORED FINISDR GTIA2014040601253Bottle · low pressureL1 DOOR ASSIST BOTTLE HAS LOW PRESSURE. ASSIST BOTTLE SERVICED IAW AMM 52-10-00-614-001.SDR USAA2014040700018Light · inoperativeEMERGENCY EXIT LIGHT AT ROW 10 LT INOPERATIVE. REPLACED LIGHT ASSEMBLY EMERGENCY EXIT LIGHT AT ROW 10 LT.SDR CALA2014040890784Epsu · failedPER 2 SVC EMERGENCY LIGHT TEST FAILS AFT 2L. REPLACED EPSU 13WL & BATTERY PACK IAW AMM 33-51-38-000-001-A.SDR CALA2014040890783Oxygen Mask · unsecureCREW REPORTS 02 MASKS FELL AT ROW 12ABC. REPACK MASK ON ROW 12ABC IAW AMM 35-21-43 & CHECK 02 GEN AMM 35-21-42 DROP TEST ACP ON TASK CARD 4R3590171 SEQ 546.SDR CALA2014040890782Skin · saturatedRIGHT ELEVATOR UPPER SKIN SURFACE HAS A WATER INGRESS INDICATION 39 INCHES FROM INBD END, 3 INCHES FROM TE, 3.5 INCHES DIAMETER. REPAIRED RT ELEVATOR UPPER SKIN AT LOCATION NOTED. DRILLED WITNESS HOLES & FOUND WATER. CUT OUT, SANDED AREA & REMOVED WATER. APSDR CALA2014040890781Skin · saturatedLEFT ELEVATOR UPPER SKIN SURFACE AREA HAS A WATER INGRESS INDICATION 35 - 43 FROM INBD END, 6 INCHES FROM TE, 7.75 X 5 INCHES DIAMETER. REPAIRED LT ELEVATOR UPPER SKIN AT LOCATION NOTED. DRILLED WITNESS HOLES & FOUND NO EVIDENCE OF WATER. APPLIED REPAIR IAWSDR CALA2014040890780Seal · wornNUMBER 1 PYLON BOTTOM METAL SEAL WORN. REMOVED STRAP & CHAFE PLATE ON LOWER SPAR. MATERIAL LOSS ON LOWER SPAR .005 INCHES. BLENDED CHAFE MARK SMOOTH. HFEC IAW NTM 51-10-20 PB6 NO CRACKS. FABRICATED EXTENDED ANTI-CHAFING PLATE IAW SRM 54-51-12 FIG 202. INSTSDR CALA2014040890779Stringer · corrodedCORROSION IN AFT PIT BILGE AREA ON STRINGER 41L FROM FRAME 63 - 64. REPLACED SECTION OF STRINGER 41L BETWEEN FRAME 62 - 63L TO FRAME 64, NEW SPLICE BETWEEN FRAME 61 - 63 & CLEAT FRAME 63 STRINGER 61 IAW SRM 53-00-13 FIG 201 & SRM 51-42-11 PG 25-27. REPAIR ATSDR CALA2014040890778Stringer · corrodedCORROSION IN AFT PIT BILGE AREA ON LT SKIN STRINGERS & FASTENERS BETWEEN FRAMES 53 - 55 & STRINGER 41 - 44L. REMOVED FACTORY SPLICE AT FRAME 53. REMOVED STRINGER 41L FROM FRAME 53 TO FRAME 59. INSTALLED NEW STRINGER 41L FROM FRAME 53 TO FRAME 59 & FACTORY SSDR CALA2014040890777Stringer · corrodedCORROSION IN AFT PIT BILGE AREA ON STRINGER 42R FROM FRAME 63 - 64. REPAIR REQUIRES SRI INSP AT DEFINED INTERVALS. REMOVED SECTION OF STRINGER 42R BETWEEN FRAME 62 - 63. INSTALLED FABRIC REPAIR STRINGER 42 BETWEEN 62 - 64 & INSTALLED FABRICATED SPLICE STRINGSDR CALA2014040890776Seal · wornNUMBER 2 PYLON BOTTOM METAL SEAL WORN. REMOVED WORN CHAFE STRIP & STRAP. MATERIAL LOSS <.002 INCHES ON LOWER SPAR. HFEC OF WORKED AREA IAW NTM 51-10-20 PB6 NO CRACKS FOUND. FABRICATED EXTENDED ANTI-CHAFING PLATE IAW SRM 54-51-12 FIG 202. INSTALLED EXTENDESDR CALA2014040890775Skin · saturatedLEFT ELEVATOR UPPER SKIN SURFACE HAS A WATER INGRESS INDICATION AT 67 INCHES FROM INBD END & 5 INCHES FROM TE 3 INCH DIAMETER. DRILLED WITNESS HOLES, NO EVIDENCE OF WATER. APPLIED REPAIR IAW TC 4R5517310 PAR 3.5 & 3.6 & SRM 51-75-12 PAR 3 P3. LT ELEVATOR RESDR GTIA2014040501250Bottle · low pressureL1 AND R2 DOOR ASSIST PRESSURE LOW. L1 AND R2 DOOR ASSIST BOTTLES SERVICED IAW AMM 52-10-00-614-001.SDR USAA2014040700017Wire Harness · faultyEMERGENCY EXIT LIGHTS ON SEATS ROW 19 LT ARE INOPERATIVE. REPLACED WALL HARNESS TO SEAT 19 LT EMERGENCY EXIT LIGHT IAW AWM 33-51-07. OPERATIONS CHECKED GOOD IAW AMM 33-51-00-710-001-A.SDR YENA20140403069Fitting · leakingAIRCRAFT RETURNED TO DEPARTURE DUE TO Y RESERVOIR LOW LEVEL. DURING INITIAL INSPECTION, FOUND LEAK COMING FROM FITTING ON DUAL DISTRIBUTION BRAKE VALVE BRAKE PRESSURE LINE. FOUND DETERIORATED O-RING R & R O-RING IAW MM 32-43-14. SERVICED YELLOW SYSTEM IAWSDR CALA2014040390750Potable Water · leakingPOTABLE WATER LEAKING FROM BELLY OF ACFT NEXT TO HYD RESERVOIR FILLING PANEL.SDR GTIA2014040301243Control Panel · defectiveNR 2 ENGINE FIRE TEST FAILED, AGENT 1 DISCHARGE ANNUNCIATOR LIGHT WILL NOT ILLUMINATE FOLLOWING TSM 26-21-00-810-813-A. FOUND ENGINE AND APU FIRE PANEL 1, 1W DEFECTIVE. R & R 1WD, IAW AMM 26-12-12. CHECKED GOOD.SDR CALA2014040390755Strut · faultyLANDING GEAR WOULD NOT RETRACT AFTER TAKEOFF. CREW REPORTED HEARING THUMP, THEN GEAR RETRACTED. ACFT DOWN LINKED CFDS FAULT MAG LT LG EXT PROXIMITY SENSOR 23 GA & LT LG EXT SENSOR 21GA. REPACKED LT MLG STRUT, PERFORMED ADJUSTMENT TEST, OPERATIONS CHECKED GOSDR USAA2014040300004Girt Bar · lack of lubeREPORTED DOOR 2L SLIDE HARD TO ARM & DISARM. LUBRICATED BOTH L2 DOOR SLIDE GIRT BARS, OPERATIONS CHECKED GOOD.SDR USAA2014040200001Cover · missingEXIT ROW RED INDICATION LIGHT ON SEAT MISSING. INSTALLED MISSING LIGHT COVER AT EXIT ROW RED INDICATION LIGHT.SDR CALA2014040390752Stringer · corrodedCORROSION IN AFT PIT BILGE AREA ON STRINGERS & FASTENERS AT DOUBLER CUT OUTS FROM FRAME 63 - 64 & STRINGER 41R. R & R STRINGER 41R FROM FRAME 58 - 64 IAW SRM 51-42-11.SDR CALA2014040390751Stringer · corrodedCORROSION IN AFT PIT BILGE AREA STRINGER 43LT BETWEEN FRAME 55 - 56. R & R STRINGER 43LT FROM FRAME 53 - 60 IAW SRM 51-42-11.SDR CALA2014040390754Strut · defectiveON ARRIVAL, FOUND NLG STRUT TO BE OVER EXTENDED, 20 MINUTES LATER, STRUT WAS FLAT. ATTEMPTED NITROGEN SERVICE, NLG WILL NOT HOLD PRESS.SDR USAA2014040100002Lens · missingEMERGENCY LIGHT COVER MISSING AT RT REAR CABIN DOOR. INSTALLED EMERGENCY LIGHT COVER AT RT REAR CABIN DOOR.SDR CALA2014033190727Power Supply · faultyLT EMERGENCY LIGHTS PSU FAULTED. REPLACED PSU IAW AMM 33- 51-38-000-001-A, OPERATIONS NORMAL.SDR CALA2014033190726Seal · damagedNLG LEAKING AFT SIDE BELOW COLLAR. REPLACED SEALS ON FWD & AFT STEERING RACK PISTONS IAW CMM 32-27-20, 32-27-19.SDR CALA2014033190729Deu · defectiveSTATIC IN CABIN SPEAKERS WITH CIDS CAUTION LIGHT ON. PERFORMED TROUBLESHOOTING 23-73-00-81 0-835A. FOUND BAD DEU A 200RH06. REPLACED & PERFORMED CIDS CHECK, ALL NORMAL.SDR USAA2014033100006Floor Panel · peelingRON VISIT, PEALED SKIN ON EDGE OF FLOOR PANEL 131HF BETWEEN FRAME 31 TO FRAME 34 & STRINGER 38L TO STRINGER 38R & Y=0. REPLACED FLOOR PANEL 131HF IAW AMM 53-22-14, PB 401.SDR USAA2014033100020Power Supply · faultyFOUND LT EMERGENCY POWER SUPPLY UNIT FAULTY. REPLACED EPSU IAW AMM 33-51-38 PB 401.SDR YENA20140328066Display · odorDURING MAINTENANCE, IT WAS NOTED THERE IS A POSSIBLE ODOR OF SMOKE OR BURNING IN THE CABIN. PERFORMED ELECTRIC ODOR INTEGRITY CHECK IAW AMM 23-39-00, SECTION 5000, STEP 10 ON ROWS 1-6 LT & RT, FOUND POSSIBLE ODOR AT 3A AND 3C. R & R VDU 3A AND 3C AS PRECAUTISDR YENA20140328065Battery Pack · faultedDURING MAINTENANCE IT WAS DISCOVERED THE EPSU BATTERY FAULTED AT 12WL. ACCOMPLISHED TSM 33-51-00-810-A. R & R EPSU AT FIN 12WL. OPS CHECKED OK.SDR CALA2014033190728Door · leakingEXTREMELY LOUD PRESS SQUEAL ROW 20. PRESSURIZED ACFT FOUND LEAK AT BOTTOM AFT CORNER ON FWD EMERGENCY EXIT HATCH. SMOOTHED REN IN SUSPECT AREA RE PRESSURIZED ACFT, CHECKED OK.SDR CALA2014032790702Skin · damagedLEFT WING FUEL TANK LANDING 540PB OTBD OF RIB 19 HAS DAMAGE AT HOLE N & F. REAMED BOTH HOLES TO 0.297 IAW SRM 57-21-11 PGS 201 - 220, FIG 202. FABRICATED NEW BUSHINGS & INSTALLED IN HOLES N & F IAW SRM 51-72-12 PGS 1-8, FIG 2. TSDR CALA2014032890714Control Unit · faultedON CLIMB OUT, ACFT ENCOUNTERED A NOSE WHEEL SENSOR FAULT, BRAKE STEERING CONTROL UNIT FAULT. FLIGHT CONTINUED, EMERGENCY DECLARED.SDR CALA2014032790704Oxygen Mask · unsecureCREW REPORTS 02 MASKS FELL AT ROW 12ABC. STOWED MASKS IAW MT 35- 003, DROP TEST TO BE COMPLIED WITH WITHIN 3 DAYS.SDR CALA2014032790701Stringer · corrodedCORROSION AFT CARGO PIT STRINGER 42R, FRAME 62 TO FRAME 63. R & R STRINGER 42R, FRAME 60 TO FRAME 64 IAW SRM 51-42-11 PG 7 & 23.SDR CALA2014032790700Stringer · corrodedCORROSION AFT CARGO PIT STRINGER 41R, FRAME 62 TO FRAME 63, NO CORROSION ALLOWABLE. R & R STRINGER 41R FROM FRAME 58 TO FRAME 64 IAW SRM 51-4 2-11 PAGE 23.SDR CALA2014032690696Autopilot Sys · malfunctionedDIVERT TO LAX DUE TO AUTO FLIGHT CONTROL ISSUE.
Back to Airbus A320-232