SDR HALA2021080900096Wire · damagedEMER EQ - PER LOG PG 794649 #1. 1R DOOR SLIDE FAULTY DUE TO WIRING, NEED TO REPLACE. // REMOVED AND REPLACED 1R ESCAPE SLIDE PER AMM 25-62-44-00 / 400-804 / 803-A. OPS AND SECURTY CHECK GOOD. OK FOR SVC.SDR HALA2021080900097Outflow Valve · defectiveETOPS - PRIOT TO DEPARTURE AVIONICS VENT OUTLET VALVE FAULT(STUCK IN HALF OPEN POSITION) MANUAL RELEASE HANDLE ALSO STUCK // REMOVE & REPLACED AVIONICS VENT OUTLET VALVE IAW AMM 21-26-53-000-002-A/400-001-A. OPS TEST GOOD PER AMM 21-26-00-710-001-A. O TO CONTISDR HALA2021080300093Fire Loop · faultedETOPS - ENG 2 FIRE LOOP B FAULT DISPLAYED NUMEROUS TIMES DURING CRUISE // PERFORMED TSM 26-12-00-810-806-A. MEASURE OHMS 1472 OHMS, VISUAL INSP TERMINAL BLOCK 2WD-D (450VT2). NO DEFECTS NOTED. REMOVED AND REPLACED FIRE LOOP B AT PYLON & REMOVED AND REPLACED FISDR HALA2021072900090Igniter · failedETOPS - WHILE TAXING IN AFTER LANDING APU ABORTED ITS START ECAM MESSAGE APU FAULT // REMOVED AND INSTALLED EGNITER PLUG IAW 49-11-41, REMOVED AND INSTALLED ELECTRICAL LEAD IAW 49-11-43 , REMOVED AND INSTALLED IGNITION UNIT 49-41-39 PERFORMED OPERATION TEST OSDR YENA2021080200492Idg · leakingETOPS: FLT 324, LAX-JFK. OIL LEAKING FROM # 2 ENG IDG VENT/BREATHER; R & R ENG 2 IDG. LEAK AND OPS TEST GOOD. ALL PARAMETERS OK. NO LEAKS NOTED. REF MM 24-21-51.SDR HALA2021072900091Wire Harness · malfunctionedETOPS - ENG 2 FIRE LOOP B FAULT CAME ON FOR 30 SECONDS. T/S PER A321 TSM 26-12-00-810-806-A. PERFORMED OP TEST ENG FIRE & OVERHEAT DET & SAME ALL TEST OK. PERFORMED GVI OF ENG 2 FIRE DET SYS IAW ESPM CH 20 & ENG 2. NEED HARNESS FIN 4166KS (DL304822). REMOSDR HALA2021072200087Fire Loop · malfunctionedETOPS - ENG2 FIRE LOOP A. PERFORMED TSM26-12-00-810-825-A & TSM 26-12-00-810-914-A. REPLACED ENG2 FIRE LOOP A PER AMM26-12-16-400-803-A AND INSTALLED PYLON FIRE DETECTOR IAW AMM 26-12-16-400-802-A. SECURITY CHECKED GOOD. RAMP ASSY.AMM26-12-00-710-001.SECURSDR HALA2021071800076Altimeter · stuckETOPS - F/O EFIS CONTROL PANEL ALTIMETER STUCK IN STANDARD// REMOVED AND REPLACED FCU PER AMM 22-81-12. OPS CHECK GOOD. PENDING LAND CAT 3 CAPABILITY TEST. AFS BITE TEST AND LAND CAT 3 CAPABILITY TEST PASSED.SDR YENA2021070900456Limiter · trippedFLT 2851, FLL-GYE. FLT CTRL SLAT FAULT ; AS PER FLIGHT CREW COMMENT RESET WAS GOOD IN FLIGHT ACCOMPLISHED TSM TASK 27-81-00-810-810-A RESET TORQUE LIMITER #7 RH AS PER AMM TASK 27-80-00 THE CHECK OF THE SLAT SYS AS PER AMM 27-84-00-710-001 TEST SATISFACTORY NSDR HALA2021061500072Gcu · faultedETOPS - ATB - ELECT GEN 2 FAULT//REMOVED AND REPLACED GCU 2 IAW AMM 24-22-34. BITE TEST OK. PERFORMED ENGINE 2 RUN UP. OPS TEST GEN 2 NORMAL. NO FAULLTS NOTED.SDR YENA2021061700370Unknown · odorFLT 1754, SJU-FLL. DURING FINAL APPROACH SMELL (METALIC ELECTRICAL) WAS OBSERVED BY FLT ATTENDANTS & PAX #1 FA TURNED ALL TV OSSAND WENT BACK TO CHECK FOR ANY HEAT FROM OUTLETS ROW 26 & 27; ACCOMPLISHED INSP OF ELECTRICAL SMELL IN CABIN PER AMM 24-00-810-823A.SDR HALA2021061400070Fire Loop · faultedETOPS - PASSING FLI 80 "ENG 2 FIRE LOOP B FAULT" MSG. MSG CLEARED AFTER APPROX 5 MINS. REPEAT WRITE UP. FOUND ENG 2 LOOP B INTERMITTENT. PERFORMED CONTINUITY CHECK PER TSM 26-12-00. NO FAULT NOTED. PRECAUTIONARY ACTION, REMOVED AND REPLACED FWD FIRE LOOP ASSY SDR HALA2021061400069Fdu · faultedETOPS - ENG 2 FIRE LOOP A ON CLIMB OUT. WENT AWAY AFTER ABOUT 5 MINUTES. REMOVED AND REPLACED FDU PER AMM 26-12-34-400-001-A OPS CHECK GOOD OK FOR SERVICE.SDR HALA2021060900065Detection Sys · malfunctionedETOPS - ENG 2 FIRE LOOP B FAULT INTERMITTENT ON CLIMB OUT. PER PFR SHOWS ENG 2 FIRE LOOP A + B AGC FAIL, PERFORMED 26-12-00-810-894-A. ALL WIRING CK INSULATION CK OK ON BOTH LOOP A AND B. RESISTANCE CK WITHIN LIMIT. VISUAL CK OK. REMOVED AND REPLACED #2 FDU PESDR HALA2021060800086Smoke Detector · faultedETOPS - WHILE ACCOMPLISHING TSI #1 002142 GROUND SCANNING SHOWS FAULT 261000 WRG: CAN BUS B/SMK DET FWD LDCC (4WH). REMOVED AND REPLACED SMOKE DET 4WH PER AMM 26-16-15. OPS CHECK GOOD. NO FAULTS NOTED. OK FOR SERVICE.SDR HALA2021060800085Drain · leakingETOPS - DURING SERVICE CHECK DISCOVERED FILTER CASE DRAIN TUBE ON #2 ENG LEAKING. REMOVED AND REPLACED #2 ENG FILTER CASE DRAIN TUBE PER AMM 23-13-49-400-805-A STEPS 4A (17), (18), (23-26). LEAK AND OPS CHECK GOOD. OK FOR SVC.SDR HALA2021060700084Fire Loop · faultedETOPS - ECAM ENG2 FIRE LOOP A FAULT, REMOVED AND REPLACED FIRE DETECTOR ENG 2 LOOP A PYLON IAW AMM 26-12-16 OPS CHECK OK NO FAULTS NOTED.SDR HALA2021060700083Fire Loop · faultedETOPS - BTB ENG 2 FIRE LOOP A FAULT ALERT ILLUMINATED ON TAXI OUT, REPLACED ENG 2 AGB LOOP A PER AMM 26-12-17-400-802-A. OPS TEST OK. OK FOR SVC.SDR HALA2021051100061Igniter · faultedETOPS - ENG START 2 FAULT. ENG 2 IGN A FAULT. SUCCESSFUL AUTOSTART AFTER SECOND ATTEMPT. BTB// REMOVED AND REPLACED IGN PER AMM 74-21-01-00-801-A ON #2 ENG. OPS CHECK GOOD. OK TO CONTINUESDR HALA2021050700058Pump · defectiveETOPS - FUEL L TK PUMP 2 LO PR DISPLAYED ON ECAM DURING CRUISE AT FL370 WITH 1HR15MINS REMAINING IN FLIGHT. FUEL TEMP 19C. // TROUBLESHOT FUEL L TK PUMP 2 LO PR PER A321 TSM 28-21-00-810-828-A. COMPLIED WITH STEPS (2) TRU (20). NO DEFECTS NOTED. (DL783821).SDR HALA2021042600051Oil System · contaminatedETOPS - ENG #1 OIL CHIP DETECT. PERFORMED TSM 79-35-00-810-808-A, FOUND NO CONTAMINATION ON CHIP DETECTORS. PER POWERPLANT ENGINEERING REPLACED OIL FILTER ELEMENT PER AMM 79-21-06-960-801-A AND REPLACED ENGINE NR1 OIL PER AMM 79-00-00-610-802-A. PERFORMED ENSDR HALA2021042600050Sensor · defectiveETOPS - ENG 2 OIL SYS FAULT ON ENGINE SHUTDOWN. PERFORM TSM JOSV 79-21-00-810-822-A. REMOVE AND REPLACED MAIN OIL PRESSURE SENSOR PER AMM 79-33-21-000/400-801-A, OPS CHECK OK. OK FOR SERVICESDR HALA2021041300047Life Raft · expiredEMER EQ - LIFE RAFT IN AFT CEILING CONTAINER EXPIRED PER HALENGINEERING AND HAL901. NEDDS REPLACEMENT // REPLACED LIFE RAFT IN AFT CEILING CONTAINER WITH SERVICEABLE PART PER AMM 25-66-41. SECURITY CHECK OK. HAL 901 INSTALLED PER GMM VOL.2. OK FOR SERVICE.SDR HALA2021040600044Battery · defectiveEMER EQ - EPSU BATTERIES 11WL AND 13WL FAULTING // REMOVED AND REPLACED EPSU BATTERIES AT 11WL AND 13WL PER AMM 33-51-38-400-002-A. OK FOR SVC.SDR HALA2021040500041Screw · failedETOPS - SCREW SNAPPED IN LH ENG OIL CONTROL MODULE // REMOVED STRIPPED FASTENER AND HELICOIL, REPLACED PER AIRBUS 321 AMM 70-24-00-910-803-ASDR HALA2021032800039Fire Loop · faultedETOPS - DURING CRZ, ECAM: " ENG1 FIRE LOOP A FAULT" ANNUNCIATED // REMOVED AND REPLACED PYLON FIRE DETECTOR ELEMENT LOOP A AND LOOP B ON # 1 ENG PER AMM 26-12-16. BITE TEST GOOD ON FDU 1. PERFORMED IDLE ENG RUN FOR FIVE MNUTES NO FAULT NOTED OK FOR SERVICE.SDR HALA2021032800038Fire Loop · brokenETOPS - #2 FIRE LOOP A FAULT // FOUND ENGINE 2 PYLON DETECTOR LOOP A (3WD2) BROKEN. REMOVED PYLON FIRE-DETECTOR RAMP ASSY PER A321 AMM 26-12-16-000-802-A. 21402. 3/29/21.SDR HALA2021031800037Power Supply · inoperativeEMER EQ - FOUND EMEREGENCY LIGHT SWITCH IN THE ARM POSIOTION WITH NO POWER TO AIRCRAFT. NUMERIOUS EMR LIGHTS THROUGHOUT CABIN INOP. // REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT (EPSU) BATTERIES PER AMM 33-51-38. BITE TESE PASSED. OPS CHK GOOD. OK FOR SESDR HALA2021031800036B-Nut · looseETOPS - ECAM:AIR ENG 1 BLEED FAULT DURING LANDING ROLLOUT. // FAULT CODE 361151, PERFORMED TSM 36-11-00-810-975-A. INSPECTED SENSE LINES, FOUND LOOSE B-NUT, TORQUED. PERFORMED LEAK CHECK PER AMM 36-22-00-790-802, AND TEST NO. 1- PNEUMATIC LEAK TEST PER AMM 71-SDR HALA2021021600017Control Unit · defectiveETOPS - WEATHER RADAR WILL NOT OPERATE ON GROUND PER STANDARD PRE-TAKE OFF OPS CHECK -BTB- // REPLACED WXR CONTROL UNIT PER AMM 34-41-12 CONDITION SAME (8054). RESECURED CONNECTOR ON WRX CONTROL PANEL. BITE TEST OF WRX #1 & #2. CHECKS OK PER AMM 34-41-00-740-0SDR HALA2021021600018Sensor · defectiveETOPS - PER TS LOG 002130 NEED TO PRERFORM TSM 79-33-00-810-841 DUE TO REPEAT WRITE UP OF # 1 ENGINE AUXILARY OIL PRESSURE SENSOR ELECTRICAL FAILURE. // PERFORMED TSM 79-33-00-810-841 NO FAULTS NOTED. REMOVED AND REPLACED #1 ENGINE AUXILLARY OIL PRESSURE SENSOSDR HALA2021020800013Balance Weight · out of balanceETOPS - #2 N1, HIGH VIBRATION DURING FUNCTION TEST. AMM 71-00-00-710-807-A // REMOVED AND INSTALLED FAN TRIM BALANCE (CA) WEIGHTS AT LOCATIONS 11,13,15 AND 19 AND C2 WEIGHT AT LOCATION 17 (5897) FUNCTION TEST (FAN TRIM BALANCE) PENDING. PERFORMED #2 ENG FUNCTSDR YENA2021012900079Engine · fireFLT 1710, PAP-FLL. RETUNRED TO FIELD. EMERGENCY DECLARED. ENGINE 2 FIRE, HI EGT TEMP, BOTH FIRE BOTTLES USED. ENGINE 2 WAS SHUTDOWN AND QRH S-4 WAS ACCOMPLISHED. SUPPLEMENTAL INFORMATION TO FOLLOW.SDR HALA2021012500010Gcu · defectiveETOPS ECAM MX STATUS "AC GEN". REMOVED & REPLACED NR 1 GCU, PER AMM 24-22-34. MX STATUS CLEARED, OK FOR SERVICE.SDR HALA2021011900006Flow Divider · looseETOPS, NR 2 ENGINE HAS FUEL LEAK. FOUND FUEL LINE FROM FLOW DIVIDER LOOSE, TIGHTENED LINE. GROUND RUN AND LEAK CHECK OK. OK FOR SERVICE.SDR HALA2021011200004Sensor · defectiveETOPS, AIR BLEED CLASS 2 ON ECAM PAGE. REMOVED & REPLACED DELTA PRESSURE SENSOR (18HA2), PER AMM 36-11-18.SDR HALA2020123100231Battery · defectiveEMERGENCY EQUIPMENT ON SERVICE CHECK CARD ITEM 10, OPERATIONAL CHECK OF EMERGENCY LIGHTS, TEST SHOWS FAULT MESSAGE: 256241- ESCAPE SLIDE LIGHT/ EPSU (13WL) AFT L- SCOURCE: CIDS 1-CLASS 1. REPLACED BATTERY IN FIN 13WL EPSU, PER AMM 33-51-38. CONDITION SAME. SDR HALA2020121500221Fire Loop · shortedETOPS, ON PDC FOUND "ENGINE 1 (LOOP A) FAULT." PERFORMED VISUAL CHECK OF ENGINE NR 1 FIRE LOOP "A", PER TSM 26-12-00-810-803-A. FOUND NO DAMAGE SH 17598. FOUND 4181KS HIGH TEMP WIRE FOR AGB LOOP A SHORTING TO GROUND. REMOVED AND REPLACED 4181KS. OPERATIONSDR YENA2020121700605Engine · warning messageFLT 262, SJU- BOS. RETURNED TO FIELD. EMERGENCY DECLARED. JUST AFTER LEAVING OFF AIR CRUISE ALTITUDE RECEIVING ECAM ENGINE 2 HEAT SYSTEM FAULT. THIS WAS IMMEDIATELY FOLLOWED BY MASTER WARNING LIGHTS AND ENGINE 2 OIL LO PR ECAM WARNING. THE NR 2 ENGINE WASSDR HALA2020113000214Anti-Ice Valve · defectiveETOPS-ANTI-ICE ENGINE 2 VALVE CLOSED. ECAM AND OVERHEAD AMBER FAULT. FAULT DID NOT CLEAR. REMOVED AND REPLACED ENGINE 2 UPPER ANTI-ICE VALVE, PER AMM 30-21-51. OPERATIONS CHECK GOOD. SECURITY AND CONDITION CHECK OK. MESSAGE CLEARED, NO FAULTS NOTED. A/CSDR HALA2020112000211Pin · detachedEMERGENCY EQUIPMENT, 2R DOOR STRING/SAFETY PIN NOT ATTACHED TO DOOR. RESECURED 2R SAFETY PIN. SECURITY CHECK OK.SDR HALA2020112000210Exciter · defectiveETOPS DMI NR 202688 BTB. ENGINE 2 IGNITION A FAULT (IGNITION SYSTEMS PW ENGINES SYSTEM A (EXCEPT FOR ER OPERATIONS, MAY BE INOPERATIVE ON ONE ENGINE ONLY)). PERF TSM 74-00-00-810-931-A. REMOVED AND REPLACED IGNITION EXCITER, PER AMM 74-11-01. OPERATIONSS CSDR HALA2020112000208Light · missingEMERGENCY EQUIPMENT, STRIP OF PATHWAY LIGHTING MISSING NEAR AFT OF A/C. REMOVED & REPLACED PHOTOLUMINESENT STRIP-FLOOR-PROXIMITY EMERGENCY ESCAPE PATH-MARKING REFERENCING AMM 33-51-21. OK FOR SERVICE.SDR HALA2020111600206Lanyard · inoperativeEMER EQUIPMENT 2L DOOR SAFETY PIN TETHER IS INOPERABLE. REATTACHED TETHER, OK FOR SERVICE.SDR HALA2020111600205Strap · brokenEMERGENCY EQUIPMENT, EMERGENCY EXIT DOORS SAFETY STRAP FOR PIN BROKE AT POSITION 2. RESECURED SAFETY STRAP. OPERATIONS CHECK, OK FOR SERVICE.SDR HALA2020101900192Fire Detector · defectiveETOPS-ENGINE 2 FIRE LOOP A FAULT. REMOVED AND REPLACED FIRE DETECTION UNIT, PER AMM 26-12-34-000-001-A AND AMM 26-12-34-400-001-A. OPERATIONS TEST OK.SDR HALA2020092430186Control Panel · malfunctionedATB, BOTH HF RADIOS ARE INOP, NO TRANSMISSION ON TRANSMIT OR RECEIVING. PERFORMED RESET AND BITE TEST OF BOTH HF SYS, IAW AMM 23-13-00. OPS TEST GOOD. PRECAUTIONALLY REMOVED AND REPLACED NR 3 RMP, PER AMM 23-13-13. OPS GOOD. NO FAULTS NOTED. OK FOR SVC.SDR HALA2020091430181Blade · damagedNR 4 FAN BLADE ON NR 2 ENGINE S/N JB1AEA4305 MISSING POLYURETHANE COAT. REMOVED AND REPLACED NR 4 FAN BLADE, PER AMM 72-11-03-400-801-A. FUNCTIONAL TEST FAN TRIM BALANCE AMM TASK 71-00-00-710-807-A PENDING. PERFORMED FUNCTION TEST (FAN TRIM BALANCE), PER AMSDR HALA2020090800178Power Supply · no testWHILE PERFORMING EMERGENCY LIGHTING SYSTEM TEST PER AMM 25-62-47-400-001A STEP 4.B.(1) GOT EPSU SYS TEST FAIL - BATT/EPSU 10WL FWD L.SDR HALA2020081100171Priority Valve · not reportedETOPS SIGNIFICANT SYSTEM. ENG 1 BLEED ABN PR RESET CB'S PER MAINTENANCE "AIR PACK 1 REGUL FAULT" ISSUE PERSISTED. PFR INDICATED PRV 1 FAULTING. INSPECTED VALVE & FOUND DIFFICULT TO OPERATE BY HAND. REMOVED & REPLACED PRV 1 PER AMM 36-11-52. LEAK CHE3CK OK. O
Back to Airbus A321-271N