What was found
ETOPS - DURING SERVICE CHECK DISCOVERED FILTER CASE DRAIN TUBE ON #2 ENG LEAKING. REMOVED AND REPLACED #2 ENG FILTER CASE DRAIN TUBE PER AMM 23-13-49-400-805-A STEPS 4A (17), (18), (23-26). LEAK AND OPS CHECK GOOD. OK FOR SVC.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ETOPS - DURING SERVICE CHECK DISCOVERED FILTER CASE DRAIN TUBE ON #2 ENG LEAKING. REMOVED AND REPLACED #2 ENG FILTER CASE DRAIN TUBE PER AMM 23-13-49-400-805-A STEPS 4A (17), (18), (23-26). LEAK AND OPS CHECK GOOD. OK FOR SVC.