SDR HALA20240820235Bypass Valve · malfunctionedATB - DUE TO ETOPS VERIICATION FLIGHT UNSATISFACTORY PLUS ISSUES WITH MULTIPLE ECAMS. PFR FAULT AIR PACK 2 REGUL FAULT ATA 21-61 CARRIED OUT TROUBLESHOOTING OF AIR PACK 2 IAW TSM 21-61-00-810-817-A. CARRIED OUT OPERATIONAL TEST OF PACK TEMP-CONTROL SYS IAW A32SDR HALA20240816228Sensor · faultedETOPS - CLASS 2 TEMP CONTROL MESSAGE FOUND ON STATUS PAGE. REMOVED AND REPLACED PACK 1 INLET SENSOR PER AMM 21-51-13-400-001-A. OPS CHECK GOOD, OK FOR SERVICESDR HALA20240816227Pump · faultedETOPS - FUEL L TK PUMP 2 LO PR ECAM IN CRUISE - NO CB POPPED. REMOVED AND REPLACED LEFT WING FUEL PUMP 2 PER AMM 28-21-51. OPS CHECK GOOD, OK TO CONTINUE.SDR HALA20240815226Filter · unknownETOPS - APU AUTO SHUTDOWN AT GATE. REMOVED AND REPLACED APU OIL FILTER AND GEN SCAVENGE FILTER PER AMM 49-91-41-200.OPS/LEAK CHECK GOOD. OK FOR SERVICE.SDR YENA2024081401118Starter · failedFLT#887, BOS-LAX. (ETOPS) 'APU AUTO SHUTDOWN. 2 ATTEMPTS. ( APU SYSTEM A321NEO ETOPS ); REMOVED AND REPLACED APU STARTER IAW AMM 49-40-00. OPS CHECK OK. RECRIMPED DAMAGED RING TERMINALS ON STARTER POSITIVE LEAD AND SENSE WIRE. THIS ACTION CLEARS MDDR 556967. MSDR HALA20240814224Pump · low pressureETOPS - MULTIPLE HYD Y ENG 2 PUMP LO PR SPURIOUS ALERTS. REMOVED AND REPLACED ENG2 PUMP PRESSURE SWITCH PER AMM 29-13-17. LEAK CK AND OPS CHECK GOOD OK FOR SVC.SDR HALA20240814223A/C Pack · faultedETOPS - AIR PACK 2 REGUL FAULT ON ECAM ON CLUMBOUT. REMOVED AND REPLACED #2 PACK COMP OUTLET TEMP SENSOR PER AMM 21-61-11. OPS,LEAK, SECURITY CHECK GOOD OK FOR SERVICE.SDR YENA2024081501119Warning Message · false activationFLT#424, LAX-JFK. 'ECAM AFTER TAKEOFF FUEL CTR R XFER FAULT; PERFORMED OPS TEST OF MAINT TRANSFER SYS AMM 28-26-00-710-001-A OPS OK COULD NOT DUPLICATE FAULT AT THIS TIME.'SDR YENA2024081401117Actuator · faultedFLT#424, LAX-JFK. (ETOPS) 'RIGHT HAND TRANSFER FAULT. ( CENTER TANK SYSTEMS 2) B) TRANSFER VALVES (WITH ACT(S)) ); REMOVED AND REPLACED RH CTR TK FUEL CONTROL-VALVE ACTUATOR 12QL PER AMM 28-26-51. ALSO REPLACED CTR TK NO. 2 AUTO CTL RELAY 8QL PER ESPM 20-46-50SDR YENA2024081201116Generator · false indicationFLT#615, JFK-SFO. (ETOPS) 'CLASS II AC GEN MESSAGE . ( CLASS II MX MSG - GPCU OR AC GEN ); SYSTEM TEST OF AC GEN GOOD, NO CLASS 2 FAULTS NOTED MDDR CLRD MX-4 UPDATED PER AMM 24-21-00.SDR HALA20240812219Exhaust Duct · cokedETOPS - AFTRER ENGINE RUN FOUND EXHAUST NOZZLE ON ENG 1 WET & WITH COKED OIL ON SURFACE. REPLACED #1 ENGINE W/ NEW REF TC 321-72-HWI-02 WO 308540. OK FOR SERVICE.SDR YENA2024081201107Unknown · odorFLT#2288, JFK-AMS. 'FA REPORT DIRTY SOCK POSSIBLE FUMES IN MID CABIN TO AFT GALLEY; COMPLIED WITH INFORMATION NOTICE 2019-T025SECTION A. ISOLATED FAULT TO TYPE 40 (40CR-A) AMBIENT AIR DOOR. BOTH ENGINE IDLE RUNS G/O LTP 50% N1, NO ODORS (SMELL NOTICED). PER TSSDR YENA2024080901105Apu · failedFLT#1908, CDG-JFK. (ETOPS) ' ( APU SYSTEM A321NEO ETOPS ); REF L/P 3321847, ITEM 2 (REMOVED AND REPLACED APU IAW AMM 49-11-11. OPS CHECK OK. ALL LEAK CHECKS OK. REF W/O 1351872 TASK CARD NUMBER:A320-49-11-11-400-004) FOR CORRECTIVE ACTION. MDDR CLOSED.'SDR HALA20240808218Wire Harness · damagedATB - AIR TURN BACK DUE TO ENG 1 SYS FAULT ON CLIMB OUT. REMOVED AND REPLACED WO3 HARNESS PER AMM 73-21-63 OPS CHECK GOOD. PENDING BIFFLE INSTALL. INSTALLED BIFFLE PER AMM 73-21-63. OK FOR SVC.SDR YENA2024080801102Warning Message · false activationFLT#1621, LHR-BOS. (ETOPS) 'AIR BLEED CLASS 2 MSG ( CLASS II MAINTENANCE MESSAGES DISPLAYED ON ECAM STATUS PAGE OF ECAM SYSTEM DISPLAY 1) FAULT(S) INDICATED BY AIR BLEED ); REF TSM TASK 36-00-00-810-804-A, PERFORMED BITE TEST OF EBAS REF AMM 36-11-00. OPS TESTSDR YENA2024080801103Actuator · failedFLT#2104, BOS-LGW. (ETOPS) 'FUEL ACT TRANSFER FAULT AT GATE APU ON ( CAUTION ON ECAM 5) ACT XFR FAULT (ACT) ); FOLLOWED TSM 25-25-00-710-150-A. CFDS SHOWS ACT VENT VALVE FAULT. REMOVED AND REPLACED ACT VENT VALVE ACTUATOR 91QH IAW AMM 28-28-72. OPS CHECK GOOD.SDR HALA20240807215Fadec · faultedETOPS - ENG 1 FADEC SYS FAULT. REMOVED AND REPLACED N2 SPEED TACHOMETER PER AMM 77-11-23-400-801-A PENDING OPS CHECK. REMOVED AND REPLACED ENG 1 ECC PER AMM 73-21-34 UP TO STEP 5(2)A. COMPLETED REMAINING STEPS OF 73-21-34. OPS CHECK GOOD. OK FOR SERVICE.SDR YENA2024080501070Gcu · failedFLT#43, JFK-LGW. (ETOPS) 'CLASS 2 MESSAGE: AC GEN ( CLASS II MX MSG - GPCU OR AC GEN ); REMOVED AND REPLACED GCU # 2 (1XU2) IAW AMM 24-22-34. OPS CHECK NORMAL. THIS CLEARS MDDR 555869. NO FAULTS OR MESSAGES NOTED AT THIS TIME. MX-4 UPDATED, PLACARD REMOVED.'SDR YENA2024080501071Fire Detector · failedFLT#20, LHR-JFK. (ETOPS) 'ENG 2 FIRE LOOP A FAULT IN FLIGHT; REMOVED AND REPLACED FIRE-OVERHEAT LOOP A IAW AMM 26-12-17. DURING ENGINE RUN FAULT DISAPPEARED. THIS CLEARS FAULT, OPS CHECK GOOD.
ENGINE: IAE, PW1133GAJM, SERIAL: P771891, TT: 4634, TC: 682SDR YENA2024080201067Fire Loop · faultedFLT#1107, JFK-LHR. (ETOPS) 'ECAM MESSAGE ENG 2 FIRE LOOP A FAULT . SPORADICALLY APPEARS . ON ON OCCASION IT WAS ON FOR SEVERAL SECOND; FOUND HI-TEMP HARNESS TOUCHING A/C FRAME + ONE ELEMENT PNCHED ON CLAMP . RE-ROUTED HI-TEMP HARNESS TO AVOID ELEMENT GROUNDINSDR YENA2024080101066Sensor · failedFLT#188, LAX-BOS. (ETOPS) 'APX 45 MINS INTO FLIGHT AT CRUISE EXPERIENCED AIR PACK 2 REGUOL FAULT. LEFT PACK ON PER QRH; PER TSM 21-61-00-810-825-A REPLACED PACK 2 OUTLET TEMP SENSOR REF AMM 26-61-11. FIN: 32HH. ER GROUND VERIFICATION PASSED.SDR YENA2024080101065Fire Detector · failedFLT#115, JFK-SFO. (ETOPS) 'ENG 2 FIRE LOOP B FAULT ECAM MSG DURING FINAL APPROACH; ACCOMPLISHED T/S PER TSM: 26-12-00-810-861-A AND L/P 4079748-1 AS PRECAUTIONARY, REPLACED ENG 2 LOOP B HARNESS 4166KS. DURING OPS TEST WHILE SHAKING LOOP B AGB DETECTOR, LOOPSDR YENA2024073001064Outlet · fumesFLT#733, BOS-SFO. 'BURNT RUBBER ODOR NOTICE BY INFLIGHT CREWMEMBERS AROUND ROW 19-26. INSEAT POWER SUPPLY SYSTEM TURNED OFF. ODOR DISSIPATED AND NEVER RETURNED FOR REMAINDER OF FLIGHT. ( IN SEAT POWER SYSTEM - INDIVIDUAL SEATS OR ENTIRE SYSTEM ); REMOVED AND RSDR YENA2024072701052Fan · failedFLT#1408, CDG-JFK. (ETOPS) 'VENT BLOWER FAULT; REMOVED AND REPLACED BLOWER FAN 20HQ PER AMM 21-26-51. ALL OPS GOOD.SDR YENA2024072701051A/C Pack · faultedFLT#1908, CDG-JFK. (ETOPS) 'AIR PACK 1 REG FAULT ( ECAM INDICATION ON BLEED PAGE PACK COMPRESSOR OUTLET TEMPERATURE ); FROM TSM 21-61-00-801-824-A OPS TEST OF PAC SYS PASSED ,AS PRECAUTION CLEANED TEMP SENSOR IAW 21-61-00-100-801,RE RAN TEST AND TEST PASSED. MSDR YENA2024072701050Unknown · unknownFLT#2223, JFK-LAX. (ETOPS) ( CLASS II MX MSG - GPCU OR AC GEN ); PERFORMED OPERATION TEST OF ALL SYSTEM (EPGS) IAW AMM 24-41-00. TEST PASSED. MX-4 UPDATED AND PLACARD REMOVED.SDR YENA2024072601048Fire Loop · faultedFLT # 2288 JFK-AMS. (ETOPS) "ECAM ENG 2 FIRE LOOP A FAULT CAME ON ONCE DURING CLIMB FOR 3 MINUTES IN TURBULENCE CLEARED ITSELF DID NOT COME ON AGAIN ( ENGINE FIRE DETECTION SYSTEMS 1) LOOP A ); REMOVED AND REPLACED GREEN, WHITE, RED, BLUE HIGH TEMP HARNESS (41SDR HALA20240726199Rod · brokenETOPS - BTB: AIR ENG 1 BLEED FAULT RESET UNSUCCESSFUL. PERFORMED TSM 36-11-00-810-988-A. FOUND FAV ACTUATOR ROD BROKEN. REMOVED AND REPLACED ACTUATOR ROD PER AMM 36-11-54. IDLE RAN AND OPS CHECK GOOD. OK FOR SVC.SDR YENA2024072701049Cids · faultedFLT#72, EDI-JFK. (ETOPS) 'CIDS 2 MESSAGE ON MTC PAGE OF ECAM ( CLASS II MX MSG DISPLAYED - CIDS ); PER TSM 23-73-00-810-920(921)A RESET CIDS. NO FAULTS SINCE DEFERRED. MX-4 UPDATED, PLACARD REMOVED.SDR HALA20240725197Filter · faultedETOPS - APU AUTO SHUTDOWN TWICE DURING PREFLIGHT. PERFORMED BITE TEST, FAULTED GEN SCAV AND LUBE FILTERS. REMOVED AND REPLACED BOTH FILTERS IN REF W/ AMM 49-91-41-200-002-A. APU OPS CHECK GOOD. LEAK CHECK GOOD. NO LEAK NOTED. OK FOR SVC.SDR YENA2024072401033Cids · faultedFLT#72, EDI-JFK. (ETOPS) 'CIDS 2 MESSAGE ON MTC PAGE OF ECAM ( CLASS II MX MSG DISPLAYED - CIDS ); PER TSM 23-73-00-810-920(921)A RESET CIDS. NO FAULTS SINCE DEFERRED. MX-4 UPDATED, PLACARD REMOVED.SDR YENA2024072701053Transceiver · failedFLT#44, LGW-JFK. (ETOPS) 'RADAR #2 SHOWS MUCH WEAKER RETURNS THAN RADAR #1; REMOVED AND REPLACED WX RADAR TRANSCEIVER #2 IAW AMM 34-41-33. OPS CHECK OK. A/C OK FOR CONT. SVC.'SDR YENA2024072401032Fire Detector · failedFLT#43, JFK-LGW. (ETOPS) 'ENG 2 LOOP A ( ENGINE FIRE DETECTION SYSTEMS 1) LOOP A ); REF T/S ON LP 4089779, ITEM #1. REMOVED AND REPLACED LOOP A ON #2 ENGINE ANGLED GEAR BOX IAW AMM 26-12-17. ALL CHECKS GOOD NO FAULT CURRENTLY PRESENT. THIS CLEARS MDDR 554847.MSDR YENA2024072401034Pump · failedFLT#534, SFO-BOS. (ETOPS) 'APU FUEL LO PR ( APU SYSTEM A321NEO ETOPS ); REMOVED AND REPLACED APU FUEL PUMP IAW AMM 28-22-51 OPS / LEAK TEST GOOD. THIS CLEARS MDDR 554682. MX-4 UPDATED. PLACARDS REMOVED.'SDR YENA2024072201024Pressure Switch · failedFLT#534, SFO-BOS. (ETOPS) 'REF LOG PAGE 3977251-2 (APU FUEL LO PR ( APU SYSTEM A321NEO ETOPS )) APU LOW FUEL PR; REMOVED AND REPLACED APU FUEL PRESSURE SWITCH IAW AMM 28-22-15.'SDR YENA2024072201023Warning Message · false indicationFLT#72, EDI-JFK. (ETOPS) '. ( CLASS II MAINTENANCE MESSAGES DISPLAYED ); OPS CHECK APU IAW AMM 49-00-00. RAN APU FOR OVER AN HOUR. NO CLASS II MESSAGE. OPS CHECK GOOD. MDDR CLOSED. MX-4 UPDATED. PLACARD REMOVED.SDR YENA2024072201022Valve · failedFLT#1908, CDG-JFK. (ETOPS) .'AFTER PUSH BACK ECAM COND TRIM AIR SYSTEM FAULT AFT CAB TRIM VALVE XX ( COCKPIT/CABIN TRIM AIR VALVES ); REMOVED AND INSTALLED TRIM AIR VALVE 13HK REF AMM 21-63-51. OPS TEST OK. THIS CLEARS MDDR 554491. MX-4 UPDATED & PLACARD REMOVSDR YENA2024072201021Fan · failedFLT#20, LHR-JFK. (ETOPS) 'VENT EXTRACT FAULT IN FLIGHT FOLLOWED QRH PROCEDURE; REMOVED AND REPLACED VENT EXTRACT (18HQ) IAW AMM 21-26-51. PERFORMED OPS TEST IAW AMM 21-26-00-710-001, TEST OK.'SDR YENA2024072201020Controller · failedFLT#20, LHR-JFK. (ETOPS) 'UPON LANDING ENG 1 HEAT SYS DEGRADED ( HEAT SYS DEGRAD CAUTIONS ON ECAM E/WD ); REMOVED AND REPLACED ENG #1 IFPC IAW AMM 73-11-01 OPS CHECK AND LEAK CHECK GOOD THIS CLEARS THE MDDR PLACARD REMOVED MX-4 UPDATED.'SDR HALA20240722195Clamp · leakingETOPS - DURING TAXI IN, APU BLEED SELECTED ON TO CONFIRM PACKS 10 MINS AFTER SELECTING ON, OBSERVED AN INTENSE BURING ASPHALT/CHEMICAL ODOR IDENTICAL TO PREVIOUS TEST FLIGHTS. REMOVED #2 RT OZONE FILTER IAW AMM 21-51-41 TO FOM FOUND CONTAMINATED. INSTALLED #2SDR YENA2024071901011Probe · failedFLT#8448, DUB-JFK. (ETOPS) 'RT TANK HI TEMP; REMOVED AND REPLACED PROBE 54QT2 IAW AMM 28-42-15. OPS CHECK GOOD IAW AMM 28-42-00-740-001.'SDR YENA2024071901010Blower · faultedFLT#1407, JFK-CDG. (ETOPS) 'IN CRUISE AT FL330 WE RECEIVED A VENT EXTRACT FAULT WE COMPLIED WITH QRH ANDCONTACTED MCC. A MUTUAL DECISION TO CONTINUE WAS MADE AS THE BLOWER WAS ON MEL; AEVC OPERATIONAL TEST CARRIED OUT IAW AMM 21-26-00 TEST SHOWS BLOWER FAN FAUSDR YENA2024071901009Warning Message · illuminatedFLT#1407, JFK-CDG. (ETOPS) 'ACT XFER FAULT ( CAUTION ON ECAM 5) ACT XFR FAULT (ACT) ); REF TSM 28-28-00-810-874-A. ACCOMPLISHED FUEL TRANSFER BETWEEN ALL TANKS IAW AMM 28-25-00. OPS CHECK GOOD. NO FAULTS/MSGS NOTED. THIS CLEARS MDDR. ALL CONFIGU'S NORMAL. PLACSDR YENA2024071901007Probe · failedFLT#44, LGW-JFK. (AIRCRAFT PERFORMED AN AIR TURN BACK TO LGW) (ETOPS) .' FUEL (R) OUTER TK HI TEMP .ECAM- FUEL NOTED TO 47C DISCUSSED W/MTC & AIR RETURN PREVIOUSLY WRITTEN WO AND MEL; ITEM ALREADY ON MEL 28-40-09C SEE MDDR 553964 (FUEL TEMP PROBE 54QT2 FAULTISDR YENA202407160105Probe · failedFLT#8442, DUB-JFK. (ETOPS) 'R TANK HI TEMP ( CAUTION ON ECAM 2) TK HI TEMP (LEFT, RIGHT WING TANK) ); FUEL TEMP PROBE 54QT2 FAULTING. REMOVED AND REPLACED 54QT2 IAW AMM 28-42-15. OPS CHECK GOOD IAW AMM 28-42-00-740-001. CLEARS MEL. (TANK TIGERS WO TT00166-A LASDR HALA20240716193Duct · contaminatedATB - AFTER TAKEOFF PRIOR TO THRUST REDUCTION, BURNING ELECTRICAL AND CHEMICAL SMELL OBSERVED IN THE COCKPIT. TAKEOFF THRUST WAS TOGA. PERFORMED DECONTAINATION OF THE BLEED AIR DUCTS LEVEL C AMM 36-10-00-615-806-A. NO BURNING SMELL WHEN PACKS 1 AND 2 ON AND OFSDR YENA2024071601005Probe · failedFLT#8442, DUB-JFK. (ETOPS) 'R TANK HI TEMP ( CAUTION ON ECAM 2) TK HI TEMP (LEFT, RIGHT WING TANK) ); FUEL TEMP PROBE 54QT2 FAULTING. REMOVED AND REPLACED 54QT2 IAW AMM 28-42-15. OPS CHECK GOOD IAW AMM 28-42-00-740-001. CLEARS MEL. (TANK TIGERS WO TT00166-A LASDR YENA2024071601004Fan · failedFLT#7, JFK-LHR. (ETOPS) 'BLOWER VENT FAULT ( BLOWER FAN - NO AVNCS SYS FAULT ECAM CAUTION ); REMOVED AND REPLACED BLOWER VENT FAN ( 20HQ) IAW AMM 21-26-51, PERFORMED OPS TEST IAW AMM 21-26-00-710-001. TEST OK, THIS CLEARS MDDR 553979, MX-4 UPDATED, PLACARD REMSDR YENA2024071500995Fire Loop · warning messageFLT#2104, BOS-LGW. (ETOPS) 'ENG 2 FIRE LOOP A FAULT MESSAGE APPEARED SHORTLY AFTER CLIMBING PAST 10000 FEET INTO THE FLIGHT AT 33000 FT THE MESSAGE DID NOT APPEAR AT ANY POINT DURING THE FLIGHT THEREAFTER ( ENGINE FIRE DETECTION SYSTEMS 1) LOOP A ); REPLACED RSDR YENA2024071901013Probe · failedFLT#8042, DUB-JFK. (ETOPS) 'FUEL (R) OUTER TANK HI TEMP. TEMP WENT UP TO 61 C AND WE SHUT OFF GENERATOR. TEMPERATURE DROPPED TO 49 - -3 C. REPEAT GRIPE. ( CAUTION ON ECAM 2) TK HI TEMP (LEFT, RIGHT WING TANK) ); FUEL TEMP PROBE 54QT2 FAULTING. REMOVED AND REPL