SDR HALA2017123100279Sensor · failedAIRCRAFT 388 DIV TO LAX DUE TO ECAM MESSAGE: AIR BLEED LOW TEMP ON BLEED 1. CORRECTIVE ACTION: REPLACED LEFT EXCHANGE OUTLET TEMP SENSOR 10HA1.SDR AALA201801029024Connector · disconnectedWHILE PERFORMING A FUNCTIONAL TEST OF THE SEAT MOUNTED EMERGENCY LIGHTING, THE LIGHT AT SEAT 33G INOPERATIVE. FOUND THE CONNECTOR AT SEAT 33G TO BE DISCONNECTED. CONNECTED THE CONNECTOR.SDR HALA2017123000331Display · failedNR 3 MCDU FAILED WITH ASSOCIATED BURNING ODOR. REMOVED AND REPLACED THE MCDU.SDR AALA201801029025Lens · detachedEMERGENCY EXIT SIGN LENS AT THE R3 DOOR DETACHED. THE LENS WAS SECURED.SDR HALA2017123000277Unknown · odorAIRCRAFT HAD A STRONG ODOR LIKE BURNING RUBBER IN THE CABIN DURING ENGINE START. DURING BOARDING THERE ALSO A STRONG BURNING RUBBER ODOR AROUND THE L1 DOOR, AND SEAT 2AB, BUT THE ODOR DISSIPATED. MAINTENANCE INSPECTED AREA, OPERATED THE APU AND ENGINE, INSPSDR AALA201801029023Bottle · low pressureL2 DOOR ASSIST BOTTLE HAD LOW PRESSURE. SERVICED THEBOTTLE.SDR HALA2017122700275Sign · detachedR3 DOOR EXIT SIGN DETACHED. REPLACED THE SIGN.SDR HALA2017122700327Fire Detector · shortedINTERMITTENT NR 2 ENGINE FIRE LOOP B FAULTED. REMOVED AND REPLACED FDU 2 IAW AMM 26-12-34, CONDITION SAME, ORIGINAL FDU REINSTALLED. FOUND PYLON DETECTOR 7WD2 READING 9.9 OHMS PIN C TO A OUT OF LIMITS AND SHORTED TO GROUND FROM STUD. REPLACED THE PYLON FIRESDR HALA2017122700324Sign · detachedEXIT SIGN AT THE R3 DOOR CEILING DETACHED. REPLACED THE SIGN. OK FOR SERVICE.SDR HALA2017122700326Frame · damagedOPEN - FOUND DAMAGE ON FRAME 24 BETWEEN STRINGER 28 & 29L. HFEC DAMAGED AREA. NO DEFECTS NOTED. INTERNAL DETAILED VISUAL CHECK OK. ACCOMPLISHED U.T.SDR HALA2018010400003Skin · damagedFOUND A GOUGE AND DENT DAMAGE TO THE LEFT SKIN BETWEEN FRAMES 21 - 26, STRINGERS 28 - 29L. INSPECTION REVEALED NO CRACKS. BLENDED IAW ERA 564572-14.SDR HALA2017122600276Lens · brokenEMERGENCY LIGHT LENS OVER THE R3 DOOR IS BROKEN. REPLACED THE LENS.SDR HALA2017122700325A/C Pack · overheatedAFTER ENGINE START, THE NR 2 AIR PACK OVERHEAT. ACCOMPLISHED ECAM ACTIONS. ECAM ILLUMINATED FOR PACK TEMP AT 144 DEGREES. PACK TEMP COOLED WHEN SELECTED OFF, TURNED ON NORMAL.SDR HALA2017122700323Transfer Sys · malfunctioned500 LBS OF FUEL IN CENTER TANK DID NOT FEED. ON PFR, FOUND MESSAGE FCMC 1, RESET AND SYSTEM TEST OF FCMC AND FUEL VALVES TEST PERFORMED IAW AMM 28-51-00-740-801A, AND 28-51-00-710-801A, BOTH TESTS PASSED. OK FOR SERVICE.SDR HALA2017122700322Lens · detachedEMERGENCY EXIT LIGHT LENS OVER THE R3 DOOR DETACHED. REPLACED THE LENS IAW AMM 33-51-17. OK FOR SERVICE.SDR HALA2017122700321Warning Message · false indicationNR 2 ENGINE BLEED NOT CLOSED, ECAM PROBLEM, RESET IAW QRH SUCCESSFUL. TROUBLESHOT IAW TSM 36-11. SYS CHECKED NORMAL. NO FAULTS. NO HISTORY, OK FOR SERVICE.SDR HALA2017122700320Pneumatic System · malfunctionedAIR NR 2 ENGINE BLEED NOT CLOSED ON THE NR 2 ENGINE SHUTDOWN. RESET THE NR 2 ENGINE BLEED SUCCESSFUL. PERFORMED TSM 36-11-81-810-837-A, NO DEFECTS NOTED. OK FOR SERVICE.SDR AALA201712249011Battery · dischargedAIRCRAFT WAS GROUNDED. EMERGENCY LIGHTS FAILED FUNCTIONAL CHECK PER J/C 33C20033002 DURING A 4 CHECK. REPLACED 8 EMERGENCY POWER SUPPLY UNIT BATTERIES PER AMM 33-51-38.SDR AALA201712249010Power Supply · no testEMERGENCY LIGHTS FAILED FUNCTIONAL CHECK IAW J/C 33C20033002. REPLACED THE POWER SUPPLY IAW MM 33-57-38. AIRCRAFT WAS GROUNDEDSDR HALA2017122100274Lens · detachedEXIT SIGN LENS FELL OFF. SECURED THE LENS.SDR AALA201712229014Oven · odorEMERGENCY DECLARED, DIVERTED DUE TO ELECTRICAL ODOR IN AFT GALLEY. OVEN OVERTEMPERATURE ACCOMPANIED BY SMOKE/FUMES (ACRID SMELL) WITH ELECTRICAL SMELL 6-11. OVER TIME, SMELL WENT AWAY. AIRCRAFT LANDED OVERWEIGHT WITHOUT INCIDENT. MAINTENANCE PERFORMED OVERWEISDR HALA2017122200314Warning Message · illuminatedDURING APPROACH, FUEL AFT TRANSFER ECAM MESSAGE. FAULT CLEARED AFTER LANDING. RESET FCMC 1 & 2. OK FOR SERVICE.SDR HALA2017122200313Warning Message · illuminatedECAM FAULT, FUEL FCMC 2 FAULT. RESET FCMC 2, AND MESSGAE CLEARED. PERFORMED SYSTEM TEST IAW AMM 28-51-00-740-801-A. TEST PASSED, OK FOR SERVICE.SDR HALA201712210031OLight · failedDURING TAXI, THE LEFT NOSE TAXI LIGHT CIRCUIT BREAKER TRIPPED. REMOVED AND REPLACED THE RIGHT TAXI LIGHT ASSY IAW AMM 33-46. OPS CHECKED GOOD.SDR HALA2017122000273Unknown · odorRETURNED TO DEPARTURE DUE TO ELECTRICAL FIRE ODOR IN THE COCKPIT. PERFORMED TROUBLESHOOTING IAW TSM 24-00-00-810-947-A, RAN PACKS INDIVIDUALLY, PERFORMED ECS AND AVEC SYSTEM TEST, PERFORMED HIGH POWER RUN, ALL TESTS WERE GOOD.SDR HALA2017122100311Warning Light · false activationAT 9000 FT DURING DESCENT, AUTO FLT FCU FAULT ILLUMINATED. BAROS WERE SET PROPERLY. RECEIVED MESSAGE 228112, FOLLOWED TSM 22-81-00-810-801A. TESTED THE AFS, NO FAULT FOUND. ACFT OK FOR SERVICE.SDR AALA201712219023Lens · not reportedEMERGENCY LIGHT LENS ADJACENT TO THE L3 DOOR. REPLACED EMERGENCY LIGHT COVER.SDR HALA2017122100310Light · malfunctionedDURING TAXI, THE LEFT NOSE TAXI LIGHT CIRCUIT BREAKER TRIPPED. OPS CHECKED THE LEFT TAXI LIGHT GOOD. FOUND THE CIRCUIT BREAKER IS FOR RIGHT NOSE TAXI TAKE OFF LIGHT. SUSPECT THE ASSEMBLY WAS BAD. SMELLED ELECTRICAL BURNING ODOR FROM ASSEMBLY.SDR AALA201712229012Battery · no testWHILE ACCOMPLISHING JOBCARD 33C22033002, EMERGENCY POWER SUPPLY UNIT BATTERY AT 2L FAILED TEST. REPLACED THE BATTERY IAW AMM 33-51-38.SDR AALA201712229011Battery · no testAIRCRAFT WAS NOT GROUNDED. WHILE ACCOMPLISHING JOBCARD 33C22033002, EMERGENCY POWER SUPPLY UNIT BATTERY AT 4L FAILED TEST. REPLACED BATTERY PER AMM 33-51-38.SDR HALA2017122000309Unknown · odorATB - ELEC FIRE SMELL IN COCKPIT AS ROTATED ON TAKEOFF. PERFORMED 24-00-00-810-947-A TSM. NO FAULTS NOTED. OPS CHECKED PACK 1 AND 2 INDIVIDUALLY. NO SMELL NOTED. INSPECTED AVIONICS BAY. NO SMELL/FAULTS NOTED. RAN ALL COCKPIT LIGHTS. NO FAULTS NOTED/SMELLSDR HALA2017121908762Power Supply · no testR4 DOOR SLIDE LIGHT EPSU FAILED SELF TEST WITH EXTERIOR LED RED LIGHT ILLUMINATED. REPLACED THE SLIDE IAW 2561-9403.SDR AALA201712219039Seat Track · corrodedCORROSION FOUND ON THE SEAT TRACK, Y450 AT FRAME 71. THE SEAT TRACK WAS REPLACED IAW SRM 51-72-11.SDR AALA201712199020Lens · brokenAIRCRAFT WAS GROUNDED. EXIT SIGN LENS ABOVE R2 DOOR IS BROKEN. REPLACED EMERGENCY EXIT OVERHEAD SIGN.SDR HALA2017121900306Power Supply · no testR4 DOOR EPSU FAIL TO SELF TEST WITH EXTERIOR LED RED LIGHT ON. REPLACED THE SLIDE IAW AMDS WORK CARD 2561-9403. CHECKED OK.SDR HALA2017121800301Unknown · odorDURING PRE FLIGHT F/A NOTED A FAINT BURNING ODOR IN THE LDCRM. INSPECTED LDCRM FOR THE ODOR. NO SMOKE ODOR DETECTED. OK FOR SERVICE.SDR AALA201712189003Bottle · low pressureL2 DOOR ASSIST BOTTLE CHARGE PRESSURE IN YELLOW BAND. SERVICED THE ASSIST BOTTLE.SDR AALA201712189002Bottle · low pressureR2 DOOR ASSIST BOTTLE CHARGE PRESSURE IN YELLOW BAND. SERVICED THE R2 DOOR ASSIST BOTTLE.SDR AALA201712189001Bottle · reads lowL3 DOOR ASSIST BOTTLE CHARGE PRESSURE IN YELLOW BAND. SERVICED THE L3 DOOR ASSIST BOTTLE.SDR HALA2017121900303Warning Light · false activationAPPROXIMATELY 15 MILES FROM LANDING, THE FUEL AFT TRANSMITTER ECAM ILLUMINATED. CLEARED ITSELF AFTER ENGINE SHUTDOWN. NO ECAM MESSAGE. PERFORMED BITE IAW AMM 28-51-00. NO TROUBLE FOUND.SDR HALA2017121500272Cover · crackedFLOOR EMERGENCY LIGHT COVER IN FROM OF FIRST CLASS LAVATORY CRACKED. REPLACED EMERGENCY THE LIGHT COVER.SDR HALA2017121900302Light · crackedEMERGENCY LIGHT AT FLOOR TRIM IN FRONT OF LAVATORY CRACKED. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-51-21. OK FOR SERVICE.SDR HALA20171800293Transfer Sys · malfunctionedDURING FINAL APPROACH, FUEL TANK TRANSFER FAULT. CHECKED CMC & CORRELATE FAULT MESSAGE FOUND. TROUBLESHOT IAW TSM 28-27-00. PERFORMED FCMC BITE TEST & TEST OK. OK FOR SERVICE.SDR HALA2017121900304Fire Loop · faultyETOPS SIGNIFICANT SYSTEM - ECAM:ENG1 LOOP B INOP. PERFORMED BITE TEST OF THE FDU1 PER AMM 26-12-00.FOUND CLASS 1 MESSAGE 261215 ENG 1 FIRE LOOP B/FDU1(1WD1). FOUND PYLON LP (6WD1) GAS LEAK. REPLACED PYLON LP DETECTOR (6WD1) PER AMM 26-12-16-400-808-A - CONTINUSDR HALA2017121800300Transfer Sys · malfunctionedFUEL T TANK XFER FAULT ECAM FOR 2 MIN FUEL 15880 0 FUEL IN T TANK. ACCOMPLISHED TSM 28-27-00-810-829-A.FCMS FUEL VALVES TEST OK IAW AMM 28-51-00-710-801.FCMS BITE TEST OK, IAW AMM 28-51-00-740-801. ACFT OK FOR SERVICE.SDR HALA20171800294Transfer Sys · malfunctionedFUEL T TANK TRANSFER FAULT ECAM FOR 2 MIN FUEL 15880 0 FUEL IN T TANK. ACCOMPLISHED TSM 28-27-00-810-829-A.FCMS FUEL VALVES TEST OK IAW AMM 28-51-00-710-801.FCMS BITE TEST OK, IAW AMM 28-51-00-740-801. ACFT OK FOR SERVICE.SDR HALA20171800292Unknown · odorAFT GALLEY A, PRODUCED SMOKE, CAUSE UNKNOWN. PULLED THE CIRCUIT BREAKER. PERFORMED AN OPERATIONAL CHECK IAW AMM 25-34 ABOUT 20 MIN. FOUND NORMAL, OK FOR SERVICE.SDR AALA201712159001Actuator · malfunctionedAIRCRAFT WAS GROUNDED. DOOR L3 DAMPER DUE DAMPING EFFECT DOES NOT OCCUR IN PASSENGER CABIN (1 EA). REPLACED L3 DOOR DAMPER.SDR HALA2017121500296Unknown · unknownETOPS SIGNIFICANT SYSTEM - ENG 2 START FAULT NO LIGHT OFF. // PERFORMED START VALVE DUTY CYCLE. PERFORMED PROCEDURES OF ENGINE
STARTING PER AMM 74-00-00-704-806-A. A/C STARTED OK.SDR HALA2017121500295Bleed Valve · faultedETOPS SIGNIFICANT SYSTEM - AIR ENGINE 1 BLEED FAULT.// REMOVED AND REPLACED #1 ENG PRESS - REG VALVE PER AMM 3
6-11-52-400-804-A PERFORMED ENG #1 RUN. VALVE OPERATES AS NORMAL. NO FAULTS NOTED OK FOR SVC.