Boeing 737-3G7
Service difficulty reports · 5,850
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7373G7' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7373G7' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AWXA9500324Eel Power Supply · inoperativePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND L2 DOOR AFT EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY, OPS CHECK GOOD. (M)SDR AWXA9500311Door Warning · activatedIND-PHX - FLT 656 - DURING CLIMB AT 4,000 FEET, THE AFT CARGO DOOR OPEN LIGHT ILLUMINATED. AC EXPERIENCED NO PRESSURIZATION PROBLEMS AND RETURNED TO IND, LANDING WITHOUT INCIDENT. NO OVERWEIGHT LANDING REQUIRED. CONTRACT MX UNABLE TO DUPLICATE PROBLEM, INSPSDR AWXA9500309Eel Battery Pack · dischargedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND L2 DOOR EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY, OPS CHECK GOOD. (M)SDR SWAA960390Channel · crackedDURING SCHEDULED 1/4 D-CHECK, FOUND CHANNEL CRACKED ABOVE VHF ANTENNA, IN FWD CARGO BIN. REPLACED CHANNEL PER BOEING SRM.SDR AWXA9500284Eel Batt Charger · inoperativePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND SEAT MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE, ROWS 5 THROUGH 11. REMOVED AND REPLACED OVERHEAD BATTERY CHARGER AT ROW 13, OPS CHECK GOOD. (M)SDR AWXA9500282Web · crackedPHX - DURING C11 INSPECTION, FOUND INNER WEB CRACKED AT STA 947 STRINGER 10R. FABRICATED NEW WEB AND INSTALLED PER SRM 51-40-02. (W)SDR AWXA9500281Skin · crackedPHX - DURING C11 INSPECTION, FOUND A .5 INCH CRACK IN SKIN AT AFT GALLEY DOOR HINGE CUT OUT. REPAIRED PER ER 3-53-35-01. (W)SDR AWXA9500280Angle · crackedPHX - DURING C11 INSPECTION, FOUND NR 1 ENGINE PYLON TRAILING EDGE SUPPORT ANGLE CRACKED IN UPPER INBOARD CORNER. REPAIRED PER SRM 51-40-02 AND SRM 51-10-02. NEW ANGLE FABRICATED AND INSTALLED. (W)SDR AWXA9500279Web · damagedPHX - DURING C11 INSPECTION, FOUND WEB ON FRAME STATION 847 STRINGER 847 STR 25R DAMAGED. FABRICATED AND INSTALLED NEW WEB PER SRM 51-70-13. (W)SDR AWXA9500278Track · corrodedDURING C11 INSPECTION, FOUND SEAT TRACK CORRODED BEYOND LIMITS AT STATION 1016 RBL 45.5. FABRICATED NEW SECTION OF SEAT TRACK PER SRM 51-40-02. (W)SDR AWXA9500277Threshold · corrodedPHX - DURING C11 INSPECTION, FOUND R2 DOOR THRESHOLD CHORD CORRODED BEYOND LIMITS. REMOVED AND REPLACED CHORD PER SRM 51-10-02 AND SRM 51-40-02. (W)SDR AWXA9500276Floor Beam · corrodedPHX- DURING C11 INSPECTION, FOUND FLOOR BEAM TOP CAP CORRODED, BS 986.5 RBL 40. REPAIRED WITH ANGLE REPAIR PER SRM 53-00-51. (W)SDR AWXA9500275Floor Beam · corrodedPHX - DURING C11 INSPECTION, FOUND FLOOR BEAM TOP CAP CORRODED, BS 986.5 BL 0 TO RBL 16. REPAIRED WITH ANGLE REPAIR PER SRM 53-00-51. (W)SDR AWXA9500274Floor Beam · corrodedPHX - DURING C11 INSPECTION, FOUND CORROSION ON FLOOR BEAM TOP CAP, BS 986.5 LBL 38. INSTALLED ANGLE REPAIR PER ER 3-53-16-25. (W)SDR AWXA9500252Battery Pack · inoperativePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND MID-CABIN EMERGENCY EXIT LIGHTS INOPERATIVE. REMOVED AND REPLACED BATTERY PACK AT OVERWING POSITION, OPS CHECK GOOD. (X)SDR AWXA9500217Eel Assy · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND MID CABIN FLOOR PROXIMITY EMERGENCY EXIT LIGHTS INOPERATIVE. RESECURED LIGHTS, OPS CHECK GOOD. (Z)SDR AWXA9500153Fuel Control · out of adjustLAS-IND - FLT 280 - DURING CRUISE, THE NR 1 ENGINE THROTTLE HAD A THREE KNOB SPLIT. ACFT RETURNED TO LAS AND LANDED WITHOUT FURTHER PROBLEMS. MX PERFORMED OVERWEIGHT LANDING INSPECTION PER BMM 05 51 74 PG 201, NO FAULTS NOTED. MX TROUBLESHOOTING FOUND THE NSDR AWXA9500189Eel Wiring · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND LAST TWO FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE. RECONNECTED WIRING, OPS CHECK GOOD. (Z)SDR AWXA9500176Fuel System · malfunctionedPHX - FLT 2172 - LAS-IAH - DURING CRUISE, THE CENTER FUEL TANK SEEMED TO CONSUME FUEL AT AN EXCESSIVE RATE, 3600 LBS TO LESS THAN 900 LBS IN APPROXIMATELY 20 MINUTES. DUE TO A POSSIBLE FUEL LEAK, CREW DIVERTED AIRCRAFT TO PHX AND LANDED WITHOUT FURTHER PROBLESDR AWXA9500146Grommets · damagedFLT 720 - LAS-ABQ - ENROUTE TO ABQ, CAPTAINS WINDOW WAS ARCING AND IGNITED RUBBER GROMMET, CAUSING FIRE AND SMOKE IN COCKPIT. FIRE WAS EXTINGUISHED, AND AIRCRAFT LANDED UNEVENTFULLY IN ABQ. CONTRACT MAINTENANCE FOUND THE CAPTAINS WINDOW THAT WAS ARCING, IN TSDR AWXA9500145O-Ring · damagedFLT 510 - PHX-OMA - DURING CRUISE, AIRCRAFT LOST 'A' SYSTEM HYDRAULICS. AIRCRAFT CONTINUED TO OMA AND LANDED WITHOUT FURTHER PROBLEMS. CONTRACT MAINTENANCE FOUND O-RINGS SEAL LEAKING AT LT WHEEL WELL HYDRAULIC PRESSURE MODULE. MAINTENANCE REPLACED O-RING, SDR AWXA9500151Wire · disconnectedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE ROWS 12 TO 14. RECONNECTED WIRING, OPS CHECK GOOD. (W)SDR AWXA9500148Jackscrew · corrodedSTATION ORD - FLT 692 - LAS-MDW - FLAPS LOCKED AT 15 DEGREES, CREW UNABLE TO OBTAIN FLAP SELECTION GREATER THAN 15 DEGREES. FLAPS WERE RECYCLED WITH NO CHANGE. CIRCUIT BREAKERS CHECKED AND FOUND OK. AIRCRAFT DIVERTED TO ORD AND LANDED WITHOUT FURTHER PROBLESDR AWXA9500140Connector · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED EMERGENCY EXIT LIGHTS INOPERATIVE, ROWS 7 THROUGH 11. REATTACHED LOOSE CONNECTOR, OPS CHECK GOOD. (W)SDR AWXA9500136Eel Wire · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOPERATIVE, ROWS 7 THROUGH 10. RECONNECTED LOOSE WIRES AT ROW 10, OPS CHECK GOOD. (W)SDR AWXA9500133Eel · inoperativePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOPERATIVE, ROWS 21 THROUGH 23. REPINNED AT ROW 21, OPS CHECK GOOD. (Z)SDR AWXA9500124Bracket · crackedPHX - FLT 1267 - DURING C6 INSPECTION, FOUND A 1 INCH CRACK IN RAM AIR INLET SUPPORT STRUCTURE 'L' ANGLE JUST BELOW DRAG ANGLE IN RADIUS. REPAIRED PER ER 1 53 20 02 AND ER 1 53 20 02B. TOTAL CYCLES 12211. (W)SDR AWXA9500123Bracket · crackedPHX - FLT 1267 - DURING C6 INSPECTION, FOUND AFT CARGO BAY FRAME ATTACH BRACKET CRACKED AT FLOOR SUPPORT ON RT SIDE, STA 787. REMOVED, FABRICATED AND INSTALLED NEW BRACKET PER SRM 51-10-02 AND SRM 51-40-02. TOTAL CYCLES 12211. (W)SDR AWXA9500131Eel Wire · loosePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR MOUNTED MID CABIN EMERGENCY EXIT LIGHTS INOPERATIVE. RECONNECTED WIRES, OPS CHECK GOOD. (Z)SDR AWXA9500114Heat Exchanger · crackedPHX - FLT 1530 - DURING C7 INSPECTION, FOUND CRACK IN RT PACK BAY PRIMARY HEAT EXCHANGER AT LOWER FORWARD END ON WELD. REMOVED AND REPLACED RT HEAT EXCHANGER PER AWA TASK CARD R2C21004. (Z)SDR AWXA9500117Eel Connnector · brokenPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR EMERGENCY EXIT LIGHTS INOPERATIVE ROWS 18 THROUGH 20. REPAIRED CONNECTOR AT ROW 20, OPS CHECK NORMAL. (Z)SDR AWXA9500102Floorbeam · corrodedPHX - FLT 1530 - DURING C7 INSPECTION, FOUND FLOOR BEAM SCREW HOLES CORRODED, STATION 986 FROM L2 TO R2. INSTALLED REPLACEMENT UPPER T-CAP AND REPAIR SPLICE PER ER 3-53-16-22. (Z)SDR AWXA9500101Floor Beam · corrodedPHX - FLT 1530 - DURING C7 INSPECTION, FOUND TOP CAP OF FLOOR BEAM CORRODED AROUND SCREW HOLES, STATION 947 LBL 12 TO RBL 8. REPAIRED DAMAGED AREA PER ER-53-16-24. (Z)SDR AWXA9500100Chord · corrodedPHX - FLT 1530 - DURING C7 INSPECTION, FOUND CORROSION ON INNER CHORD AT RT AFT LAV FORWARD BULKHEAD R2 DOOR AREA. REMOVED AND REPLACED CHORD PER SRM 51-10-02 AND 51-40-02. (Z)SDR AWXA9500099Intercostal · corrodedPHX - FLT 1530 - DURING C7 INSPECTION, FOUND INTERCOSTAL BETWEEN BS 967 AND 986 RBL 20 CORRODED BEYOND CLEAN UP LIMITS AROUND SCREW HOLES. REMOVED AND REPLACED INTERCOSTAL PER SRM 51-10-1 AND SRM 51-30-02. (Z)SDR AWXA9500098Intercostal · corrodedPHX - FLT 1530 - DURING C7 INSPECTION, FOUND ANGLE INTERCOSTAL CORRODED BEYOND LIMITS AT SCREW HOLES, BS 986 TO 1006 LBL 18. FABRICATED AND INSTALLED INTERCOSTAL PER ER 53-10-01B. (Z)SDR AWXA9500097Floorbeam · corrodedPHX - FLT 1530 - DURING C7 INSPECTION, FOUND FLOORBEAM CORRODED BEYOND LIMITS AROUND SCREW HOLES, STATION 967 LBL 48. REPAIRED DAMAGED AREA PER ER 3-53-16-23. (Z)SDR AWXA9500096Former · crackedPHX - FLT 1530 - DURING C7 INSPECTION, FOUND NR 2 ENGINE PYLON FAIRING FORMER CRACKED AT UPPER END IN RADIUS. REMOVED AND REPLACED CRACKED FORMER PER SRM 51-10-02 AND SRM 51-40-02. (Z)SDR AWXA9500095Angle · crackedPHX - FLT 1530 - DURING C7 INSPECTION, FOUND SUPPORT BRACKET CRACKED ON AFT FLANGE, STATION 540 BETWEEN BL 0 AND LBL 24. REPAIRED ANGLE PER SRM 51-70-11. (Z)SDR SWAA950174Skin · crackedDURING SCHEDULED 1/2 D CHECK, FOUND CRACK IN UPPER CORNER OF LOWER HINGE SKIN CUTOUT AT FWD SERVICE DOOR. REPAIRED PER SWA ACO 3189-52.SDR AWXA9500083Eel Batt Charger · inoperativePHX - DURING ROUTINE MAINTENANCE CHECK, FOUND R2 DOOR EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED LT BATTERY CHARGER ASSEMBLY, OPS CHECK NORMAL. (W)SDR AWXA9500054Actuator · inoperativePHX - FLT 460 - OAK-LAS - A VIBRATION WAS FELT DURING CLIMB, CRUISE AND DESCENT. THE VIBRATION SEEMED LIKE AIRFRAME, CREW TRIED INCREASING AND DECREASING ACFT AND ENGINE SPEED, BUT UNABLE TO DETERMINE. ACFT LANDED WITHOUT FURTHER PROBLEMS. MX REPLACED NR 6 SDR AWXA9500056Strut Assy · brokenRNO-PHX - FLT 460 - ON TAKEOFF AND INITIAL CLIMB, ACFT EXPERIENCED ROLL TO RT TENDENCY, 20 DEGREES LT AILERON WAS REQUIRED TO COUNTER UNTIL APPROXIMATELY 170/180 KIAS. ACFT CONTINUED TO PHX WITHOUT FURTHER PROBLEMS. MX FOUND STRUT ASSEMBLY FOR RT WING UPPER SDR AWXA9500055Actuator · failedLAS - FLT 959 - AT TAKEOFF, CREW ENCOUNTERED A MODERATE ROLL TO THE RT. APPROXIMATELY 50 PERCENT YOKE DEFLECTION WAS REQUIRED TO MAINTAIN THE WINGS LEVEL. ACFT CONTINUED TO LAS WITHOUT FURTHER PROBLEMS. MX REMOVED AND REPLACED RT O/B FLAPS TOGGLE. FLAPS OPSDR AWXA9500031Pressurization · malfunctionedABQ - FLT 864 - ABQ-PHX - AIR TURN BACK, CREW UNABLE TO PRESSURIZE AIRCRAFT IN AUTO, STANDBY OR MANUAL MODES. AIRCRAFT RETURNED TO ABQ AND LANDED WITHOUT FURTHER PROBLEMS. MAINTENANCE GROUND PRESSURIZED AIRCRAFT, CHECKED OUTFLOW VALVES, DOOR SEALS AND BY-PASSDR AWXA9500013Angle · corrodedPHX - FLT 1600 - DURING SCHEDULED INSPECTION, FOUND FLOOR BOARD SUPPORT CORRODED BEYOND CLEAN UP LIMITS, STATION 957 RBL 10 TO RBL 18. REMOVED, FABRICATED AND INSTALLED NEW INTERCOSTAL PER SRM 51-10-02 AND 51-40-02. (W)SDR AWXA9500012Angle · corrodedPHX - FLT 1600 - DURING SCHEDULED INSPECTION, FOUND FLOOR BOARD SUPPORT CORRODED BEYOND CLEAN UP LIMITS, STATION 957 LBL 18 TO LBL 40. REMOVED, FABRICATED AND INSTALLED NEW INTERCOSTAL PER SRM 51-10-02 AND 51-40-02. (W)SDR AWXA9500022Eel Battery Pack · dischargedPHX - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY EXIT LIGHTS INOPERATIVE AT SEATS 13-18. REMOVED AND REPLACED BATTERY PACK, OPS CHECK GOOD. (W)SDR AWXA9500007Motor Actuator · inoperativeLAX-LAS - FLT 74 - AIR TURNBACK, STABILIZER TRIM WAS INOPERATIVE WITH YOKE TRIM SWITCHES (BOTH CAPT AND F/O). ACFT RETURNED TO LAX AND LANDED WITHOUT FURTHER INCIDENT. CONTRACT MX REPLACED STAB TRIM MOTOR ACTUATOR IAW AWA TASK CARD R6C27001, NO DEFECTS NOTEDSDR AWXA9500006Intercostal · corrodedPHX - FLT 485 - DURING SCHEDULED INSPECTION, FOUND CRACK IN INTERCOSTAL AFT OF STATION 380 BL 0. REMOVED, FABRICATED AND REPLACED ANGLE PER SRM 51-40-02. (W)
Back to Boeing 737-3G7