Boeing 737-490
Service difficulty reports · 3,288
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737490' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737490' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA9740095Mechanism · lack of lubeOAK - PRIOR TO FLT 469 - THE L1 DOOR HANDLE WAS FOUND TO BE HARD TO CLOSE. LUBED AND CYCLED DOOR, OPERATED NORMAL. (M)SDR ASAA9740091Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE AFT 6 EACH EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (X)SDR ASAA9740087Battery Pack · dischargedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 2-6 AND LOWER EXIT IDENTIFIER WERE FOUND TO BE INOPERATIVE. REPLACED BATTERY PACK AND CHARGER AND LIGHTS OPERATED NORMALLY. (M)SDR 97ZZZM1148Batt Charger · failedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 2-6 AND LOWER EXIT IDENTIFIER WERE FOUND TO BE INOPERATIVE. REPLACED BATTERY PACK AND CHARGER AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9740084Battery Charger · inoperativeJNU - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE FROM THE FORWARD CLOSET TO ROW 8. REPLACED BATTERY CHARGER AND LIGHTS OPERATED NORMALLY. (X)SDR ASAA9740083Battery · dischargedJNU - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE FROM THE FORWARD CLOSET TO ROW 8. REPLACED BATTERY AND LIGHTS OPERATED NORMALLY. (X)SDR ASAA9740080Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT ROW 27 AFT. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9740065Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE AFT FOUR EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR 97ZZZX3966Girt · pulled outFOUND BOTH THE LEFT AND RIGHT FORWARD EMERGENCY ESCAPE SLIDE GIRTS PULLED OUT OF THE CONTAINERS. WHEN GIRT IS PULLED FROM CONTAINER, IT DRAGS ON THE FLOOR. TO IDENTIFY IF IT IS PULLED OUT, THE VELCRO FUZZY LOOP MATERIAL ON THE BACK SIDE OF THE GIRT CAN BE FESDR ASAA9740041Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AT ROW 18. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (X)SDR ASAA9740035Wire · disconnectedSEA - DURING MAINTENANCE CHECK, THE FORWARD 2 AND AFT 4 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9740019Dust Cover · bentANC - FLT 82 - CREW REPORTED, L1 DOOR DIFFICULT TO CLOSE. FOUND DUST COVER ON LOWER HINGE BENT, STRAIGHTENED COVER AND DOOR OPERATED NORMALLY. (M)SDR ASAA9740017Guide Arm · out of adjustSEA - FLT 571 - AFTER ARRIVAL, CREW REPORTED THAT THE L1 DOOR HANDLE WAS DIFFICULT TO CLOSE TO THE LOCKED POSITION. ADJUSTED GUIDE ARM ASSEMBLY AND DOOR OPERATED NORMALLY. (M)SDR ASAA9740016Connector · dirtyANC - DURING MAINTENANCE, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT ROWS 1 AND 2. FOUND DEBRIS PREVENTING PROPER CONNECTION OF ELECTRICAL CONNECTOR. REMOVED DEBRIS, RECONNECTED AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9740003Frame · elongated holeSEA - DURING C-CHECK, THE AFT CARGO COMPARTMENT INNER FLANGE OF THE FUSELAGE FRAME AT STATION 727D WAS FOUND TO HAVE AN ELONGATED HOLE BETWEEN STRINGERS 26R AND 27R. REPAIRED IAW ASA EA 5310-01516. (M)SDR ASAA9640053Socket · inoperativeJNU - DURING MAINTENANCE CHECK, THE AFT FOUR EMERGENCY EXITFLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. REPLACED TRACK LIGHT LAMP SOCKETAND ALL LIGHTS OPERATED NORMALLY.(M)SDR ASAA9640046Battery · dischargedSEA - DURING DEPLOYMENT OF L2 DOOR SLIDE FOR TRAINING, THE EMERGENCY LIGHTS WERE FOUND INOPERATIVE. REMOVED AND REPLACED BATTERY AND LIGHTS OPERATED NORMALLY. (X)SDR ASAA9640022Wire · disconnectedSEA - FLT NR 98 - CREW REPORTED THAT THE FORWARD 4 EMERGENCY EXIT TRACK LIGHTS WERE FOUND TO BE INOPERATIVE. RECONNECTED WIRING THAT HAD BECOME DISCONNECTED AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9540107Wire · disconnectedJNU - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AT ROWS 21 THROUGH 24. RECONNECTED TRACK WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9540100Snubber · defectiveSEA - DURING MAINTENANCE CHECK, THE L1 DOOR WAS FOUND DIFFICULT TO OPEN AND CLOSE. REPLACED DOOR SNUBBER ASSEMBLY AND OPERATED NORMALLY. (M)SDR ASAA9540099Lamp Base · defectiveJNU - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS FROM ROW 22 AFT WERE FOUND INOPERATIVE. REPLACED LAMP BASE ASSEMBLY AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9540085Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE FORWARD 4 EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED WIRING ON FORWARD TRACK AND LIGHTS OPERATED NORMALLY. (X)SDR ASAA9540084Eel Assy · brokenSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT LIGHT AT THE L-2 DOOR WAS FOUND BROKEN. REPLACED LIGHT ASSEMBLY AND LIGHT OPERATED NORMALLY. (X)SDR ASAA9540071Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE AFT FOUR EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED TRACK WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9540069Eel Reflector · wornSEA - DURING MAINTENANCE CHECK, THE L-2 DOOR EXTERIOR EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED REFLECTOR/SOCKET ASSEMBLY AND LIGHT OPERATED NORMALLY. (M)SDR ASAA9540065Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE AFT TWO EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED TRACK LIGHT WIRING, REPLACED LENS AND LIGHTS OPERATED NORMALLY. (X)SDR ASAA9540060Eel Wiring · disconnectedANC - DURING MAINTENANCE CHECK, THE AFT TWO RED EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED AFT FLOOR TRACK WIRING AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9540057Eel Connector · looseSEA - DURING MAINTENANCE CHECK, TWO RED EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE IN THE AFT CABIN. RECONNECTED LOOSE CONNECTOR AT SECOND FROM LAST RED LIGHT AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9540056Eel Connector · looseSEA - DURING MAINTENANCE CHECK, TWO RED EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE IN THE AFT CABIN. RECONNECTED LOOSE CONNECTOR AT SECOND FROM LAST RED LIGHT AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9540051Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AFT OF ROW 27. RECONNECTED WIRE HARNESS IN TWO PLACES AFT OF ROW 27 AND LIGHTS OPERATED NORMALLY. (M)SDR ASAA9540049Eel Wiring · disconnectedSEA - ON ARRIVAL OF FLT NR 103, CREW REPORTED THE EMERGENCY EXIT FLOOR TRACK LIGHTS FROM ROWS 10 TO 13 WERE FOUND INOPERATIVE. RECONNECTED WIRING AND REPLACED LIGHT ASSEMBLY AT ROW 11 AND LIGHTS OPERATED NORMALLY. (M)SDR 95ZZZM596Eel Assy · defectiveSEA - ON ARRIVAL OF FLT NR 103, CREW REPORTED THE EMERGENCY EXIT FLOOR TRACK LIGHTS FROM ROWS 10 TO 13 WERE FOUND INOPERATIVE. RECONNECTED WIRING AND REPLACED LIGHT ASSEMBLY AT ROW 11 AND LIGHTS OPERATED NORMALLY. REFERENCE ASAA9540049.SDR ASAA9540048Eel Wiring · disconnectedSEA - FLT NR 413 - EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 11 AND 12 WERE FOUND INOPERATIVE. RECONNECTED WIRING AT ROWS 11 AND 12, LIGHTS OPERATED NORMALLY. (M)SDR ASAA9540036Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROW 12 WERE FOUND INOPERATIVE. REPAIRED TRACK WIRING AND LIGHTS OPERATED NORMALLY. (W)SDR ASAA9540032Eel Wiring · disconnectedSEA - ROW NR 9 WHITE FLOOR EMERGENCY LIGHT INOP. MAINTENANCE RECONNECTED LOOSE WIRE. (M)SDR ASAA9540011Eel Wiring · disconnectedSEA - AT CHECK, TRACK LIGHTS AT ROWS 14 TO 17 INOP. MAINTENANCE RECONNECTED WIRES. (W)SDR ASAA9549Eel Wiring · looseSEA - DURING CHECK, EMERGENCY FLOOR LIGHTS INOP AT ROWS 15 AND 16. MAINTENANCE REPAIRED LOOSE WIRING. (W)SDR ASAA95011Eel Wiring · disconnectedSEA - DURING MAINTENANCE CHECK, THE AFT TWO EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. RECONNECTED TRACK WIRING AND LIGHTS OPERATED NORMALLY (W)
Back to Boeing 737-490