Boeing 737-7H4
Service difficulty reports · 96,125
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2023011089864Rivet · shearedL1 DOOR SLIDE GIRT BAR STOWAGE BRACKET HAD ONE RIVET SHEARED. INSTALLED A RIVET IAW SRM 51-40-02.SDR SWAA2023011090191Slide · detachedFORWARD GALLEY SERVICE DOOR PARTIALLY OPENED WITH GIRT BAR ARMED<[01] INSPECTED DOOR SLIDE FOUND TO BE PULLED FROM COVER WAS NOT DEPLOYED REPACKED SLIDE REF AMM25-66-01 AC OK FOR SERVICESDR SWAA2023011089846Cover · detachedEMERGENCY EXIT LIGHT COVER 1ABC FELL OFF IN FLT. SECURED THE COVER IAW SIP.SDR SWAA2023021089725Structure · crackedCABIN PASSENGER FLOOR STRUCTURE STA303.9 LEFT WL208 THRESHOLD INNER CORD HAS CRACK<[01] INSTALLED EWIS PROTECTION AT CABIN PASSENGER FLOOR STRUCTURE STA. 303.9 LEFT WL 208 THRESHOLD INNER CORD REF B 737-700 AMM 20-60-07-913-801;[02] REMOVED FASTENERS FOR ACCESSDR SWAA2023020296572Web · crackedCRACK WEB LOCATED BS847 TO BS867 AT LEVEL LBL27 AT AFT CARGO COMPARTMENT 2023-37054<[01] REPLACED WEB LOCATED BS847 TO BS867 AT LEVEL LBL27 AT AFT CARGO COMPARTMENT I.A.W. B737-700 SRM 51-40-02 AND DRAWING # 149A8100 REV ? .SEE INDIVIDUAL SIGN OFF BELOW;[02] TSDR SWAA2023020289763Light · deterioratedDETERIORATED PHOTOLUMINESCENT STRIP AT PASSENGER CABIN (10 EA) 2023-37104<[01] REPLACED PHOTOLUMINESCENT STRIP AT PASSENGER CABIN (10 EA) I.A.W B737-700 AMM 33-51-15-400-802.;[02] REPLACED PHOTOLUMINESCENT STRIP AT PASSENGER CABIN (10 EA) I.A.W B737-700 AMM 33SDR SWAA2023020289771Support Angle · crackedCRACK ANGLE - SUPPORT LOCATED STA 500D AT LEVEL STR 28L AT FWD CARGO COMPARTMENT 2023-36495<[01] REPLACED ANGLE - SUPPORT LOCATED STA 500D AT LEVEL STR 28L AT FWD CARGO COMPARTMENT IAW B737-700 SRM 51-10-02; SRM 51-40-02 AND DWG 143A7902 ; SHEET 12; REV: A;[02SDR SWAA2023011089569Circuit Breaker · trippedEMERGENCY CIRCUIT BREAKER FOUND TRIPPED, RESET. NO 10 DAY HISTORY. NOTED BY MAINTENANCE IAW MPM 52-06-05.SDR SWAA2023011089625Sign · looseFRONT SERVICE DOOR EXIT SIGN LOOSE. REPLACED EMERGENCY LIGHT ASSY IAW AMM 33-51-01.SDR SWAA2023022004695Panel · crackedL/H WING FUEL ACCESS PANEL 532RB PLATE LOWER SURFACE CRACKED. (18-093)<[01] RECEIVED L/H WING NEW FUEL ACCESS PANEL #532RB WILL BE INSTALLED T/C TTG8Q00GDEB6;[02] VERIFIED STEP 1.SDR SWAA2023020789034Web · corrodedCORROSION ON FWD CARGO BAY DOOR CUT-OUT SUB-THRESHOLD WEB FROM STA 440+7 TO STA 480+10; RBL 26 TO RBL 29; WL 156.<[01] VERIFIED APPLICABILITY IAW SRM 53-30-15-0L-1 FOR IDENTIFICATION AND SRM 53-30-15-1A-1 FOR ALLOWABLE DAMAGE.<BR>REMOVED CORROSION ON FWD CARGOSDR SWAA2023020789028Shield · corrodedCORROSION ON FWD CARGO BAY DOOR CUTOUT AFT SHIELD FROM STA 480+14 TO STA 500+18; RBL 24; WL 156.<[01] THIS PART DOES NOT HAVE ALLOWABLE DAMAGE LIMITS. IT HAS TO BE REPAIRED BY REPLACEMENT PER SRM 51-10-02-0G. STEP 9.;[02] VERIFIED STEP 1;[03] SHIELD ASSY. RECESDR SWAA2023020789029Support · corrodedCORROSION ON FWD CARGO BAY R/H AFT FLOOR TO SIDEWALL SUPPORT FROM STA 500A+2 TO STA 500C+15; RBL 23 TO 25; WL 156.<[01] VERIFIED APPLICABILITY SRM 53-30-53-01-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.<BR><BR>REMOVED CORROSION ON FWD CARGSDR SWAA2023020789030Support · corrodedCORROSION ON FWD CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT FROM STA 460+14; TO 500C+16; LBL 25 TO 23; WL 156.<[01] REMOVED CORROSION ON FWD. CARGO BAY UPPER SURFACE FROM FLOOR TO SIDEWALL SUPPORT BS 460+14' LBL25 WL 156 IAW SRM 51-10-02 AND MAX. MATERIAL LOSS ONSDR SWAA2023020289455Panel · crackedCRACK ACCESS PANEL 193AR HOLES AT LOWER FUSELAGE 2023-37045<[01] TOOL USED: CALIPER P/N: 500-197-30; S/N: B20189526; DUE DATE: 20-DEC-23.;[02] TOOL USED HOT BONDER P/N: HCS9200B-AV S/N: 18185847 24 SEP 23.;[03] TOOL USED HOT BONDER P/N HCS9200B-AV S/N 18196127SDR SWAA2023020289447Beam · corrodedCORROSION FLOOR BEAM LOCATED BS986.5 AT RBL41 AT PASSENGER CABIN 2023-37029<[01] TOOL USED THICKNESS GAGE; P/N: 45MG; S/N: 221861811; DUE DATE: 08-NOV-23.;[02] PERFORMED REPAIR ON FLOOR BEAM 985.5 I.A.W EA 23-153-00095-WIP1 AND EA SUMMARY 23-153-00095. SEE INDSDR SWAA2023020289449Beam · corrodedCORROSION FLOOR BEAM LOCATED BS986.5 AT LBL41 AT PASSENGER CABIN 2023-37028<[01] TOOL USED THICKNESS GAGE; P/N: 45MG; S/N: 221861811; DUE DATE: 08-NOV-23.;[02] TOOL USED EDDY CURRENT EQUIPMENT PN/ NORTEC 600D; SN/ 210138503; DUE DATE/ 19-MAY-23.;[03] REPAIRED SDR SWAA2023020289460Intercostal · corrodedCORROSION WEB - INTERCOSTAL LOCATED BTW STA 807 TO STA 827 AT LEVEL STR 18R AND WL 198 AT AFT CARGO COMPARTMENT 2023-36433<[01] REPLACED WEB-INTERCOSTAL LOCATED BTW STA 794 TO STA 847 AT LEVEL STR 18R AND WL 198 AT AFT CARGO COMPARTMENT. IAW SRM B737-700 51-40SDR SWAA2023020289453Plate · crackedCRACK CORRUGATED PLATE TRAILING EDGE LOCATED AT ORSS 271 AT RT WING 2023-37038<[01] REPLACED CORRUGATED PLATE TRAILING EDGE LOCATED AT ORSS 271 AT RT WIN I.A.W B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02. SEE INDIVIDUAL SIGN OFF BELLOW.;[02] TASK CARD COMPLESDR SWAA2023011989238Support Bracket · crackedAFT CARGO BAY SUPPORT BRACKET CRACKED, BS 867, LBL 15, WL 154. LOCATED AND DRILLED A NEW SUPPORT BRACKET IAW SRM 51-40-05-0G-0, DWG 149A8102, REV-, & DWG 149A8104, REV B. INSTALLED THE NEW SUPPORT BRACKET IAW SRM 51-40-02-0G-0, DWG 149A8102, REV-, & DWG 14SDR SWAA2023010989580Slide · dislodgedFWD SERVICE DOOR SLIDE FELL OUT OF CASE<[01] REPACKED FWD SERVICE DOOR SLIDE INTO CASE AND INSTALLED ON FWD SERVICE DOOR PER AMM 25-66-01SDR SWAA2023010989605Slide · dislodgedFWD ENTRY SLIDE FELL OUT WHEN OPENING FWD ENTRY DOOR<[01] REINSTALLED FWD ENTRY SLIDE PER AMM 25-66-01.SDR SWAA2023010989591Cover · missingFWD GALLEY EXIT LIGHT COVER MISSING. INSTALLED MISSING FWD EXIT LIGHT COVER IAW SIPSDR SWAA2023010989112Battery Pack · inoperativeMULTIPLE FWD ENTRY EMERGENCY LIGHT INOP<[01] REMOVED AND REPLACED FWD ENTRY EMERGENCY LIGHT BATTERY PACK PER AMM 33-51-06. OPS CHECK GOODSDR SWAA2023010989113Battery Pack · inoperativeR/H OVERWING MULTIPLE EMERGENCY LIGHT INOP<[01] REMOVED AND REPLACED R/H OVERWING EMERGENCY EXIT LIGHT BATTERY PACK PER AMM 33-51-06. OPS CHECK GOODSDR SWAA2023010989170Access Door · faultedGROUND A/C DOOR WILL NOT CLOSE<[01] R&R FORWARD FAIRING ACCESS DOOR IAW MM 52-49-01.SDR SWAA2023010989578Retainer · out of adjustFLT ATT REPORTS; FWD ENTRY DOOR SLIDE GRIT BAR LOOSE @ RETAINER CLIP<[01] ADJUSTED GRIT BAR RETAINER HOLDER ( CLIP ) PER M/M S.I.PSDR SWAA2023010989162Lamp · inoperativeLEFT OVERWING EXIT WINDOW LIGHT INOP.<[01] RELAMPED LEFT OVERWING EXIT WINDOW LIGHT; SATISFACTORY OP CK REF AMM 33-21-00.SDR SWAA2023021088964Intercostal · crackedFWD CABIN FLOOR SUPPORT INTERCOSTAL IS CRACKED BETWEEN 344-360 AT CENTER LINE<[01] REMOVED FWD CABIN FLOOR SUPPORT INTERCOSTAL BETWEEN 344-360 AT CENTER LINE IN REF SRM 51-40-02-0G-0; FOUND OUT OF LIMITS IN REF SRM 51-10-02-0G-0;[02] LATE ENTRY :<BR>INSTALLED SDR SWAA2023021088971Beam · corrodedFLOOR BEAM 986.5 IS CORRODED ON TOP CAP 6 INCHES INBOARD OF R-2 DOOR SILL<[01] FOUND EXFOLIATE CORROSION AROUND FASTENER HOLE; OUT OF LIMITS PER SRM;53-70-51-1A-1;[02] REMOVED INTERCOSTAL BETWEEN STA. 986.5 AND STA. 1006 AND RBL 38; AND ATTACH ANGLES; PER REF SDR SWAA2023021088957Intercostal · crackedCABIN FLOOR SUPPORT INTERCOSTAL IS CRACKED BETWEEN 328-344 47' LEFT OF CENTER LINE<[01] REMOVED DAMAGED CABIN FLOOR SUPPORT INTERCOSTAL PER REF 51-40-02-0G-0.;[02] INSTALLED EWIS PROTECTION AT FWD CABIN STA 328-344 47' LEFT OF CENTER LINE PER REF AMM 20-60-07-SDR SWAA2023021088965Intercostal · crackedFWD CABIN FLOOR SUPPORT INTERCOSTAL IS CRACKED BETWEEN 344-360 12 INCHES LEFT OF CENTER LINE<[01] PLACED EWIS PROTECTION FROM STA 344-360.12 PER REF AMM 20-60-07-913-801;[02] REMOVED FOR ACCESS INTERCOSTAL STA 344-360 BL 0 PER REF SRM 51-40-02-0G-0;[03] REMOVESDR SWAA2023021088602Strip · elongatedAFT CARGO R/H FLOORS CAP STRIPS; HOLES ELONGATED<[01] RECEIVED NEW AFT CARGO R/H FLOORS CAP STRIPS; P/ 453A2611-11; -13;-9 AND- 1; NEW CAP STRIPS TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q004G38U;[02] VERIFIED STEP 1SDR SWAA2023021088608Strip · elongatedL/H AFT CARGO FLOORS CAP STRIPS WITH HOLES ELONGATED<[01] RECEIVED NEW AFT CARGO.; L/H FLOORS CAP STRIPS; P/N 453A2611-8;-10;-13; AND-2; NEW CAP STRIPS TO BE INSTALLED ON CUSTOMER BAR CODE TTG8Q004G38U;[02] VERIFIED STEP 1SDR SWAA2023021088961Support · corrodedCABIN FLOOR SUPPORT BETWEEN 294.5 - 312 10 INCHES LEFT OF CENTER LINE IS CORRODED<[01] INSTALLED EWIS PROTECTION AT CABIN FLOOR SUPPORT BETWEEN 294.5 - 312 10 INCHES LEFT OF CENTER LINE IN REF AMM 20-60-07-913-801;[18] VERIFIED STEPS 16 AND 17;[19] REMOVED ANDSDR SWAA2023021088968Bracket · crackedLEFT WING T/E BY DEFLECTOR PANEL SUPPORT BRACKET CRACKED DOT 39<[01] REMOVED SUPPORT BRACKET AT L/W T/E BY DEFLECTOR IN REF 51-40-02-0G-0;[02] LOCATED AND DRILLED SUPPORT BRACKET AT R/W T/E BY DEFLECTOR IN REF SRM 51-40-05-0G-0;[03] CORRECTION TO STEP #2:<BR>LSDR SWAA2023020988962Intercostal · crackedCABIN FLOOR SUPPORT INTERCOSTAL IS CRACKED BETWEEN 288-294.5 ON CENTER LINE<[01] REMOVED INTERCOSTAL CRACKED AT MAIN CABIN STA 288 TO STA 294.5 BL 0 PER SRM 51-40-02-0G-0;[02] VERIFIED STEP 1;[03] OK TO LOCATE AND DRILL HOLES;[04] LOCATE AND DRILLED NEW INTERCSDR SWAA2023020695699Panel · crackedCRACK ACCESS PANEL HOLES 661CB AT RT WING 2023-36978<[01] TOOL USED: HOT BONDER P/N: HCS9200B-AV; S/N: 18196119; DUE DATE: 24-FEB-23.;[02] TOOL USED: SCALE: P/N: CL5000 S/N:AE-409558 DUE DATE:09-JUN-23;[03] TOOL USED: HOT BONDER P/N: HCS9200B-AV S/N: 18196126 SDR SWAA2023020296233Angle · crackedCRACK ANGLE LOCATED BS 500B AT LEVEL STR26L AT FWD CARGO COMPARTMENT 2023-36976<[01] REPLACED ANGLE LOCATED BS 500B AT LEVEL STR26L AT FWD CARGO COMPARTMENT I.A.W SRM B737-700 51-40-02 AND DRAWING 143A7505 REV:- . SEE INDIVIDUAL STEP SIGN OFFS BELOW;[02] REPLASDR SWAA2023020289077Angle · crackedCRACK ANGLE LOCATED BS 500C AT LEVEL STR26L AT FWD CARGO COMPARTMENT 2023-36977<[01] REPLACED ANGLE LOCATED BS 500C AT LEVEL STR26L AT FWD CARGO COMPARTMENT I.A.W SRM B737-700 51-40-02 AND DRAWING 143A7505 REV:-. SEE INDIVIDUAL STEP SIGN OFFS BELOW;[02] REPLACSDR SWAA2023020289076Gusset · crackedCRACK GUSSET LOCATED BS 500D AT LEVEL STR19L FWD CARGO COMPARTMENT 2023-36974<[01] REPLACED GUSSET LOCATED BS500D AT LEVEL STR19L FWD CARGO COMPARTMENT I.A.W B737-700 SRM 51-10-02 ITEM 9 AND SRM 51-40-02 AND DWG 143A7902 SHEET 174 REV. -<BR><BR>SEE INDIVIDUAL SDR SWAA2023020289080Panel · elongatedELONGATED HOLE BULKHEAD PANEL 142MW AT AFT CARGO COMPARTMENT 2023-36993<[01] FABRICATED BULKHEAD 142MW AT AFT CARGO COMPARTMENT IAW B737-700 AMM 25-52-01-201-801 AND DRAWING #453A2510 SHEET 13 REV A-MATERIAL USED PN#A60SG4W ;PO# 2022-104980;[02] FABRICATED BULSDR SWAA2023020289082Angle · crackedCRACK ANGLE LOCATED BS294.5 AT LEVEL STR17R AT FWD GALLEY AREA 2023-36986<[01] REPLACED ANGLE AND FASTENER LOCATED BTW BS291.5 TO BS294.5 AT LEVEL STR17R AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG 141A8310 REV-. SEE INDIVIDUAL SIGN OFF BELOW.;[02] CESDR SWAA2023020289078Not Entered · crackedCRACK INNER CHORD LOCATED BS303.9 AT LEVEL STR17L AT FWD GALLEY AREA 2023-36983<[01] REPLACED INNER CHORD AND FASTENER LOCATED BTW BS259.5 TO BS360 AT LEVEL STR17L AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG 140A9810 REV- AND 141A8310 REV-. SEE INDIVISDR SWAA2023020289083Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT RBL45 FWD GALLEY AND LAV 2023-36987<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT RBL45 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING # 141A5400 REVSDR SWAA2023020289085Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS344 TO BS360 AT LBL11 FWD GALLEY AND LAV 2023-36990<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS344 TO BS360 AT LBL11 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING #141A5400 REV:SDR SWAA2023020289081Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT LBL45 FWD GALLEY AND LAV 2023-36984<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT LBL45 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9. AND DRAWING # 141A5400 RESDR SWAA2023020289079Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS285.62 TO BS294.5 AT BL0 FWD GALLEY AND LAV 2023-36985<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS285.62 TO BS294.5 AT BL0 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 ITEM 9. AND DRAWING # 141A5SDR SWAA2023020289084Intercostal · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS344 TO BS360 AT BL0 FWD GALLEY AND LAV 2023-36989<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS344 TO BS360 AT BL0 FWD GALLEY AND LAV IAW B737-700 SRM 51-10-02 AND DWG# 141A5400 REV: -. SEE INDIVIDSDR SWAA2023020295698Panel · crackedCRACK ACCESS PANEL HOLES 661BB AT RT WING 2023-36979<[01] TOOL USED: CALIPER P/N: 500-197-30; S/N: B20189526; DUE DATE: 20-DEC-23.;[02] TOOL USED: HOT BONDER P/N: HCS9200B-AV; S/N: 18196119; DUE DATE: 24-FEB-23.;[03] TOOL USED: SCALE: P/N: CL5000 S/N:AE-409558
Back to Boeing 737-7H4