Boeing 737-7H4
Service difficulty reports · 96,125
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7377H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022121471328Pressure Deck · crackedMID PASSENGER CABIN HORIZONTAL PRESSURE DECK CRACKED BS663+2 RBL40. FABRICATED A REPAIR DOUBLER, STIFFENERS, AND WEB REPLACEMENT IAW SRM 53-40-51-2R-2, PAR.4. E. 1. FIG. 201-202, TABLE 201, PAR G, H, & I. APPLIED CHEMICAL CONVERSION COATING TO REPAIR AND WESDR SWAA2022121371330Stiffener · crackedLEFT HORIZONTAL STAB INSPAR RIB, HSS 129.50, THIRD VERTICAL STIFFENER WAS CRACKED. ACCOMPLISHED HFEC OPEN HOLE AND CUT OUT INSPECTION, NO CRACKS NOTED IAW NDTM PART 6; 51-00-00, PROCEDURE 16, AND 23. ACCOMPLISHED GVI OF ALL AREAS WITHIN REPAIR AREA, AND UNSDR SWAA2022121371331Stiffener · crackedLEFT HORIZONTAL STAB INSPAR RIB, HSS 129.50, SECOND VERTICAL STIFFENER WAS CRACKED. ACCOMPLISHED HFEC OPEN HOLE AND CUT OUT INSPECTION, NO CRACKS NOTED IAW NDTM PART 6, 51-00-00, PROCEDURE 16, AND 23. ACCOMPLISHED GVI OF ALL AREAS WITHIN REPAIR AREA AND UNDSDR SWAA2022121371332Stiffener · crackedLEFT HORIZONTAL STAB INSPAR RIB, HSS 129.50, 4TH VERTICAL STIFFENER WAS CRACKED. ACCOMPLISHED HFEC OPEN HOLE AND CUT OUT INSPECTION NO CRACK NOTED IAW NDTM PART 6; 51-00-00, PROCEDURE 16 & 23. ACCOMPLISHED GVI OF ALL AREAS WITHIN REPAIR AREA, INCLUDING UNDESDR SWAA2022121371326Floor Support · crackedCABIN FLOOR SUPPORT CRACKED AT BS 540, LBL 1, WL 208. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02-0G-0, AND DWG 143A0060.SDR SWAA2022121371329Attach Angle · crackedMID CABIN ATTACH ANGLE CRACKED AT BS 663+29, RBL 24. REMOVED THE ATTACH ANGLE IAW SRM 51-40-02. FABRICATED A NEW ATTACH ANGLE. LOCATED AND DRILLED THE NEW ATTACH ANGLE IAW DWG 273A9112, REV -. TREATED AND PRIMED THE NEW ATTACH ANGLE. INSTALLED THE NEW ASDR SWAA2022121371327Attach Angle · crackedMID CABIN ATTACH ANGLE FOUND CRACKED, BS 663+29, LBL 24. REMOVED ATTACH ANGLE IAW SRM 51-40-02. FABRICATED A NEW ATTACH ANGLE, LOCATED, AND DRILLED IAW DWG 273A9112, REV -. TREATED AND PRIMED THE NEW ATTACH ANGLE. INSTALLED THE NEW ATTACH ANGLE IAW DWG 273A9SDR SWAA2022121371216Support Fitting · damagedELONGATED HOLES ON SUPPORT FITTING LOCATED ON BS 1016 BL 0. REPLACED THE SUPPORT FITTING IAW SRM 51-10-02, AND 51-40-02.SDR SWAA2022121271220Bracket · corrodedCORROSION WEB LOCATED OUTBOARD LEADING EDGE OFSS396 AT RT WING 2022-638857 / [01] REPLACED BRACKET ASSY OF FUEL QTY INDICATORS IAW B737-700 AMM 28-41-61-401-NG AND PERFORMED OPERATIONAL TEST OF FUEL QTY INDICATORS.TEST IS OK<BR>SEE INDIVIDUAL SIGN OFF BELOW;[0SDR SWAA2022120971214Floor Panel · damagedELONGATED HOLE ON FLOOR PANEL 120CF IN THE FWD CARGO BAY. FABRICATED A NEW FLOOR PANEL IAW SRM 51-40-05, SRM 51-20-01, AND DWG 453A1610, SHEET 23, REV C.SDR SWAA2022120971215Floor Panel · damagedELONGATED HOLE ON FLOOR PANEL 120BF IN THE FWD CARGO BAY. FABRICATED A NEW FLOOR PANEL IAW SRM 51-40-05, SRM 51-20-01, AND DWG 453A1610, SHEET 7, REV C.SDR SWAA2022120871212Intercostal · crackedCRACKED INTERCOSTAL LOCATED BS 847 TO BS 867 UPPER POSITION AT LEVEL LBL 24.75 AFT CARGO COMPARTMENT. REPLACED WEB-INTERCOSTAL IAW SRM 51-40-02 AND SRM 51-10-02, ITEM 9, AND DWG 149A8100, SHEET 1, REV-.SDR SWAA2022120771211Floor Panel · damagedELONGATED HOLE ON FLOOR PANEL 120AF IN THE FWD CARGO BAY. FABRICATED A NEW FLOOR PANEL IAW AMM 25-52-01-201-801, DWG 453A1610, SHEET 9, REV F.SDR SWAA2022120171166Scuff Plate · crackedAFT CARGO BAY AFT CORNER SCUFF PLATE CRACKED. WELDED SCUFF PLATE IAW SRM 53-60-15-2R-1, PARA 4 B. 2 AND 4. INSPECTED AREA IAW SOPM 20-20-02. NO CRACKS NOTED. SANDED AREA SMOOTH IAW SRM 53-60-15-2R-1, PARA 4B 5.SDR SWAA2022111671444Slide · looseSLIDE LOOSE ON R-2 DOOR. R-2 DOOR SLIDE CHECKED FOR SECURITY IAW MMMM 25-66-01. OK FOR SERVICE.SDR SWAA2022111671007Battery Pack · intermittentDURING MV-2 CHECK FOUND SEVERAL AFT CABIN EMERGENCY LIGHTS INTERMITTENT. REMOVED AND REPLACED LH AFT EMERGENCY LIGHT POWER PACK M1673 IAW AMM 33-51-06. OPS CHECK NORMAL.SDR SWAA2022121370958Access Panel · crackedCRACKED SURGE TANK ACCESS DOOR 633BB ON DUCT, RT WING. REPLACED THE ACCESS PANEL IAW AMM 28-13-31-400-801.SDR SWAA2022120870956Bracket · crackedCRACK UPPER BRACKET, STRINGER 10L, BS 460. REPLACED THE BRACKET IAW SRM 51-40-02, AND 51-10-02, ITEM 9.SDR SWAA2022111670605Light · looseAISLEWAY PHOTOLUMINESCENCE STRIP IS COMING LOOSE NEXT TO FORWARD LEFT WINDSCREEN WHERE AISLEWAY CARPET MEETS THE FORWARD GALLEY MAT. / [01] CLEANED AREA UNDER STRIP AND RE-ADHERED AS REQUIRED. RE-SEALED MOON MAT. REF AMM 33-51-15.SDR SWAA2022121470770Bulkhead Web · crackedCRACKED VAPOR BARRIER BULKHEAD PRESSURE DECK WEB, BS 663, LBL 30, WL 159. REMOVED THE PREVIOUSLY INSTALLED INTERIM REPAIR THAT WAS DOCUMENTED ON NRC G626816 - LBL 31.83 (MOD 6-42404). PERMANENT REPAIR WILL BE INSTALLED PER SRM 57-10-10 ALLOWABLE DAMAGE 2 ANDSDR SWAA2022121470771Bulkhead Web · crackedCRACKED RT VAPOR BARRIER BULKHEAD PRESSURE DECK WEB AT BS 663 RBL 39 WL 163. DAMAGE IS BEYOND ALLOWABLE LIMITS IAW SRM 57-10-10-1A-2, PARAGRAPH 4 D 1 AND REPAIRED IAW SRM 51-70-04-2R-10, SRM 57-10-10-2R-2, PARAGRAPH 1C.SDR SWAA2022121470775Angle · crackedCRACKED VAPOR BARRIER BULKHEAD PRESSURE DECK WEB UPPER ATTACH ANGLE, BS 663, LBL 5, WL 165. DAMAGE FOUND OUT OF LIMTS IAW SRM 57-10-10-1A-2. PERFORMED DVI OF REPAIR AREA AND UNDERLYING STRUCTURE, NO DAMAGE IAW SRM 51-00-06. FABRICATED A REPLACEMENT ASDR SWAA2022121270659Access Panel · crackedCRACKED ACCESS PANEL 661CB TRAILING EDGE HOLES RT WING. REPAIRED ACCESS PANEL 661CB TRAILING EDGE RT WING IAW SRM 51-70-04-2R-10, REPAIR 10.SDR SWAA2022121270670Access Panel · crackedCRACK ON HOLES LOCATED ACCESS PANEL 661BB AT RT WING. REPAIRED ACCESS PANEL 661BB AT RT WING IAW B737-700 SRM 51-70-04-2R-10 REPAIR 10.SDR SWAA2022120970663Floor Support · crackedCRACKED INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 344 TO BS 366 BL 0. REPLACED THE INTERCOSTAL FLOOR STRUCTURE AND FASTENERS LOCATED BETWEEN BS 344 TO BS 360 BL 0 AT FWD GALLEY AREA IAW SRM 51-40-02, AND DWG 141A5400, SHEET 32, REV-.SDR SWAA2022120970664Floor Support · crackedCRACKED INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 344 TO BS 366 LBL 12 AT FWD GALLEY AREA. REPLACED WITH A NEW INTERCOSTAL AND FASTENERS. LOCATED AT FLOOR STRUCTURE BTW BS344 TO BS360 AND LBL12 IAW SRM 51-40-02 AND DWG 141A5400, REV A.SDR SWAA2022120970671Structure · crackedCRACK INNER CHORD BS 303.9 LBL 57 WL 208.1 AT FWD GALLEY AREA. REPLACED INNER CHORD AND FASTENERS BTW BS 270 - 360, LBL 57, WL 208.1 IAW SRM 51-40-02. DWG 141A8110 REV A, SHEET 9, AND DWG 140A9810, SHEET 48, REV-.SDR SWAA2022120870655Floor Support · crackedCRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 TO BS 328 LBL 46 AT FWD GALLEY. REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE IAW SRM 51-40-02, AND DWG 141A5400, REV -.SDR SWAA2022120870662Floor Support · crackedCRACKED FLOOR STRUCTUREBETWEEN BS 328 - 344, LBL 46. FWD GALLEY. REPLACED IAW 51-10-02, ITEM 9, AND SRM 51-40-02.SDR SWAA2022120870656Floor Support · crackedCRACKED FLOOR SUPPORT, BETWEEN BS 312 - 328, RBL 13. REPLACED THE FLOOR SUPPORT IAW SRM 51-40-02, AND DWG 141A5400, REV- .SDR SWAA2022120870661Floor Support · crackedCRACKED FLOOR SUPPORT, BETWEEN BS 294.5 - 312, RBL 15 IN THE FWD GALLEY. REPLACED THE FLOOR SUPPORT IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, AND DWG 141A5400 REV A.SDR SWAA2022120870683Strap · corrodedCORROSION STRAP BS 1016 PLUS 8 INCH LBL 3; WL 208.1 AT AFT GALLEY AREA 2022-638761 / [01] REPLACED STRAP BS 1016 PLUS 8 INCH LBL 3; WL 208.1 AT AFT GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING #147A5600 SHEET 32 REV. B. SEE INDIVIDUAL SIGN-OFF BELOSDR SWAA2022120870684Strap · corrodedCORROSION STRAP BS 1016 RBL 3 WL 208.1 AT AFT GALLEY AREA 2022-638762 / [01] REPLACED STRAP BS 1016 RBL 3 WL 208.1 AT AFT GALLEY AREA IAW B737-700 SRM 51-10-02 Ï¿½TEM 9 AND DRAWING# 147A5730 SHEET 23 REV. C. SEE INDIVIDUAL SIGN-OFF BELOW;[02] REPLACED STRAP BSSDR SWAA2022120870679Strap · corrodedCORROSION STRAP BS 1016 PLUS 13 INCH RBL 18 WL 208.1 AT AFT GALLEY AREA 2022-638763 / [01] REPLACED STRAP BS 1016 PLUS 13 INCH RBL 18 WL 208.1 AT AFT GALLEY AREA AND FASTENERS IAW B737-700 SRM 51-40-02 AND DRAWING # 147A5730 SHEET 23 REV. C. SEE INDIVIDUAL SINSDR SWAA2022120870674Floorbeam · corrodedCORROSION FLOOR EAM BS 986.5 LBL 43; WL 208.1 AT AFT GALLEY AREA 2022-638753 / [01] TOOL USED: ULTRASONIC THICKNESS GAGE P/N: 45MG S/N: 130060401 DUE DATE: 26-JAN-23;[02] TOOL USED EDDY CURRENT INSTRUMENT P/N NORTEC500D S/N N500X11290U021704 DUE DATE 01-FEB-23SDR SWAA2022120870673Floorbeam · corrodedCORRODED FLOORBEAM, BS 986.5, RBL 43, WL 208.1, IN THE AFT GALLEY. REPAIRED THE FLOORBEAM IAW SRM-53-70-51-2R-6, REPAIR 6, ALTERNATIVE 4, FIG. 205.SDR SWAA2022120870682Web · corrodedCORRODED WEB, BS 1016 + 13, LBL 17, WL 208.1, IN THE AFT GALLEY. EDDY CURRENT INSPECTION COMPLIED WITH. REPLACED THE WEB IAW SRM 51-40-02, AND DWG 147A5600 REV B.SDR SWAA2022120870660Floor Support · crackedCRACKED FLOOR SUPPORT BETWEEN BS 277 - 294.5 BL 0, IN THE FWD GALLEY. REPLACED THE FLOOR SUPPORT IAW SRM 51-10-02, ITEM 9, AND DRAWING 141A5400 REV -.SDR SWAA2022120870681Skin · crackedCRACK INDICATION FOUND ON LT HORIZONTAL STAB LOWER IN-SPAR SKIN AT HSS 193.90, RIB, 25 INCH FROM FRONT SPAR. CRACK LENGTH 0.750 INCH. PERFORMED REPAIR ON LH HORIZONTAL STABILIZER LOWER IN-SPAR SKIN AT HSS 193.90 RIB; 25.00 INCH FROM FRONT SPAR; INBD SIDE OFSDR SWAA2022120770340Light · deterioratedDETERIORATED PHOTOLUMINESCENT FLOOR LIGHT. REPLACED FLOOR LIGHT IAW DWG 33500007, REV 2, AND SOPM 20-50-12, REV 55.SDR SWAA2022120770676Angle · crackedCRACKED ANGLE BETWEEN BS 291.5 - 294.5, RBL 53. REPLACED THE ANGLE IAW SRM 51-10-02, ITEM 9, SRM 51-40-02, AND DWG 141A8310 SHEET 25, REV-.SDR SWAA2022120770677Structure · corrodedCORROSION INNER STRUCTURE BETWEEN BS 947.5 - 986.5, RBL 51, WL 208.1 IN THE AFT GALLEY. REPLACED THE INNER STRUCTURE AND FASTENERS IAW SRM 51-40-02-0G-0, SRM-51-10-02, ITEM 9, AND DWG 147A8501, SHEET 93 REV A. 147A0060 SHEET 64 REV- AND DWG 147A0000, SHEET 45SDR SWAA2022120170275Handle · missingFWD ENTRY DOOR LINER LOWER AFT ASSIST HANDLE IS MISSING. A NEW DOOR ASSIST HANDLE WAS INSTALLED IAW AMM 52-11-31-400-802, STEPS 3, G, 2, A - D.SDR SWAA2022113070732Floorbeam · crackedFLOORBEAM CRACKED AT BS 540, LBL 1, WL 208. REMOVED AND REPLACED THE FLOORBEAM IAW SRM 51-40-02-0G-0.SDR SWAA2022113070733Floor Support · crackedCABIN FLOOR SUPPORT CRACKED AT BS 540, RBL. 1, WL 208. REMOVED THE FLOOR SUPPORT IAW SRM 51-40-02-0G-0. LOCATED & DRILLED A NEW FLOOR SUPPORT IAW SRM 51-40-05-0G-0. INSTALLED THE NEW FLOOR SUPPORT IAW SRM 51-40-02-0G-0.SDR SWAA2022111670386Attach Angle · crackedRT WING; FWD ATTACH ANGLE CRACKED FOR PANEL 651AT ATTACH CHANEL RT WING FWD ATTACH ANGLE CRACKED FOR PANEL 651AT ATTACH CHANEL / [01] REMOVED AND REPLACED ANGLE BRACKET IAW SRM 51-40-04SDR SWAA2022111570453Slide · out of positionL1 DOOR SLIDE HANGING OUT THE BOTTOM OF COMPARTMENT / [01] REPOSISTIONED SLIDE IN COMPARTMENT PER AMM 25-66-01-400-804SDR SWAA2022111570452Retainer · dirtyFLIGHT ATTENDANT REPORTS FWD ENTRY DOOR GIRT BAR DIFFICULT TO MANIPULATE / [01] ADJUSTED GIRT BAR ON FWD ENTRY DOOR AND CLEANED RETAINING CLIPS. OPS CK?D GOOD PER M/M 25-66-01SDR SWAA2022111570455Lens · missingR/H OVERWING EXIT LIGHT MISSING LENS / [01] INSTALLED A NEW EXIT LIGHT LENS ON THE R/H OVERWING EXIT REF AMM 33-51-01SDR SWAA2022111571110Actuator · inoperativeELECTRIC TRIM INOPERATIVE AFTER TAKEOFF. HORIZONTAL STABILIER TRIM. / [01] -SPEED TRIM FAIL LIGHT ILLUMINATES ON RECALL.<BR>-NO C/B?S POPPED.<BR>-FAULT MESSAGE 22-11182. (DFCS BITE);[02] R&R STAB TRIM CUTOUT RELAY (R384) OPS CHECK AND CLOSE UP REQUIRED.;[03] P
Back to Boeing 737-7H4