Boeing 737-824
Service difficulty reports · 9,839
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737824' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737824' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2017040700891Skin · crackedHORIZONTAL STAB LOWER SKIN HSS 129.50 FOUND CRACKED, 11 INCHES FROM AFT SPAR. THE SKIN WAS REPAIRED IAW SRM 55-10-01, REP 11.SDR CALA2017040400838Light · inoperative21C SEAT LIGHT INOP. REMOVED AND REPLACED INOP SEAT EMERG LIGHT AT SEAT 21C. OPS CK NORMAL REF AMM 33-51-11.SDR CALA2017040400837Light · broken15C EEL LITE BROKEN. REMOVED AND REPLACED BROKEN EEL LIGHT ON SEAT 15C. REF AMM 33-51 -11. OPS CK NORMAL.SDR CALA2017040400836Sign · detachedEXIT SIGN OVER STOWAGE AREA 425, AFT LIFE RAFT, HAS FALLEN FROM CEILING. REINSTALLED EXIT SIGN COVER.SDR CALA2017040400835Battery Pack · dischargedEMERGENCY LIGHTS IN FIRST CLASS AND R1 AREA INOP. R&R EMERGENCY LIGHT BATTERY PACK IAW AMM 33-51-06.SDR CALA2017040400834Light · inoperativeEXTERIOR SLIDE EMERGENCY LIGHT INOP AT AFT LEFT. REPLACED LAMP AND OPS CKD NORMAL PER AMM 33-51-04-990-801.SDR CALA2017040400832Light · inoperativeEMERGENCY EXIT SIGN DOES NOT TURN ON. 122 SIGN ABOVE 2R FELL NEEDS REINSTALL. REPLACED LIGHT AND LENS. OPS NORMAL. OK FOR SERVICE.SDR CALA2017040400831Sign · looseEMERGENCY EXIT SIGN DOES NOT TURN OFF. 4R AFT EXIT SIGN 4R COVER FELL OFF. REINSTALLED EMERGENCY EXIT 4R.SDR CALA2017040400829Power Supply · inoperativeAFT OVERWING LOWER INTERIOR EMERGENCY EXIT LIGHT SIGNS NOT ILLUMINATED AT END OF EMERGENCY BATTERY CAPACITANCE CHECK JC 29-0550-8-0124. REMOVED AND REPLACED POWER SUPPLY FOR AFT OVERWING LOWER INTERIOR EMERGENCY EXIT LIGHTED SIGNS IAW AMM 33-51-06 OPS CHECK GOSDR CALA2017040400827Sign · loosePART OF THE EXIT SIGN OVER ROW 4 FELL OFF. RESECURED EXIT SIGN AT ROW 4. OPS CHKED EMER LIGHTS. OPS CKS GOOD.SDR CALA2017040400825Battery Pack · dischargedL1 DOOR EXTERIOR, INTERIOR O/H, AND FWD AISLE EMERGENCY LIGHTS ARE INOP. T/S, RPLCD BATTERY PACK AS NEEDED. OPS GOOD.SDR CALA2017040400830Sign · unsecureEMERGENCY EXIT SIGN FELL OFF FROM REAR GALLEY DOOR 2R. SECURED EXIT SIGN, OK FOR SERVICE.SDR CALA2017040400828Sign · unsecureEXIT SIGN FELL OFF IN FIRST CLASS. INSTALLED EMERGENCY EXIT SIGN.SDR CALA2017040400833Light · inoperativeL2 DOOR EMER LIGHT INOP. RELAMP L2 DOOR EMER LIGHT PER AMM 33-51-04, OPS CHECK GOOD.SDR CALA2017040400800Transmitter · faultyFLAPS TRAILING EDGE FLAP LOCKOUT ON APROACH TE FLAPS EXTENDED AND LOCKED PRIOR TO 1. LE FLAPS TRANSIT LIGHT STAYS ON. EMERGENCY DECLARED. TROUBLESHOT, REMOVED AND REPLACED THE LEFT FLAP TRANSMITTER IAW AMM 27-58 -01-000-801, 400-801 AND TESTED IAW AMM TASK 27SDR CALA2017040400798Skin · crackedCRACK INDICATED ON LEFT HORIZONAL STAB STA HSS 101.9, 10 INCHES FROM T/E. VERIFI ED THE CRACK WITH EDDY CURRENT. CUT OUT DAMAGED AREA AND INSTALLED A DOUBLER IAW SRM 55-10-01, REPAIR 11.SDR CALA2017040400795Rib · crackedLEFT HORIZONTAL STAB BEAM CRACKED AT THIRD STIFFENER FROM FWD SPAR LOCATED 33 INCHES FROM FUSELAGE. CUT OUT DAMAGE AND REPAIRED IAW ECRA 5510-02736.SDR CALA2017040400786Skin · crackedCRACK INDICATED WHILE PERFORMING C-SCAN ON LT HORIZONTAL STAB LOWER I NSPAR SKIN AT 184.70, 10 INCHES FROM T/E. VERIFIED WITH EDDY CURRENT. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER REPAIR IAW SRM 55-10-0 1 REPAIR 11.SDR CALA2017040400785Skin · crackedTWO CRACKS INDICATED WHILE PERFORMING C-SCAN ON THE LT HORIZONAL STAB HSS 129.5 APPROXIMATELY 8 AND 14 INCHES FROM THE T/E. VERIFIED THE CRACKS WITH EDDY CURRENT. CUT OUT THE DAMAGED AREAS AND INSTALLED REPAIRS IAW SRM 55-10-0 1 REPAIR 11.SDR CALA2017032700744Light · inoperativeEMERGENCY FLOOR PROXIMITY LIGHT AT SEAT 15ABC, 20ABC, 21ABC AND LT OVERWING EXIT INOP.SDR CALA2017032600730Control Lever · intermittentWHILE RAISING GEAR THE 3 RED DISAGREE LIGHTS REMAINED ILLUMINATED RAN QRH. EMERGENCY DECLARED. BITE TEST ON PSEU FOUND FAULT 32-62008 AND FIM TASK FOUND CONTROL LEVER INTERMITTENT. R/R SAME PER AMM 32-31-11.SDR CALA2017032500719Unknown · odorCREW REPORTED PLASTIC SMELL THRU OUT CABIN. EMERGENCY DECLARED. RAN ENG'S FOR HALF HOUR, ISOLATED PACKS NO PLASTIC SMELL NOTED. AC HAD FAN LUBE ON OVERNIGHT MAINT IN EWR..SDR CALA2017032400700Starter Gen · arcedAPU GENERATOR TRIPPED OFF LINE, AFTER RECONNECT, SMELLED AN ELECTRICAL BURNING ODOR THRUOUT ACFT. FOUND EVIDENCE OF ARCING AT APU STARTER GENERATOR TERMINAL BLOCK FILTER. REMOVERD AND REPLACED THE STARTER GENERATOR, IAW AMM 49-41-21-400-801.SDR CALA2017032400699Unknown · odorAFT GALLEY HAD BURNING ODOR LEFT AFT. DISSIPATED BUT STILL HAS AN ODOR. INSPECTED AFT GALLEY AND AFT LAVATORIES. RAN COFFEEMAKERS, CHECKED OVENS, AND ALL LIGHTS. COULD NOT DUPLICATE.SDR CALA2017032400712Battery Pack · inoperativeEMERGENCY LIGHT BATTERY PACK 1694 DOES NOT HOLD A CHARGE. REMOVED AND REPLACED THE BATTERY PACK IAW AMM 33-51-06, OPS CHECKED GOOD.
SDR CALA2017032400679Compressor · faultySMOKE COMING FROM BOTH SIDES OF CABIN 3 ROWS FROM REAR. REMOVED AND REPLACED POTABLE WATER TANK COMPRESSOR IAW AMM 38-42 -01 AND CHECK VALVE IAW AMM 38-42-09. SYS OPS CHECK GOOD.SDR CALA2017032400687Battery Pack · dischargedSEAT 22-28 LH BULLNOSE EMERGENCY LIGHTS ONLY ILLUMINATE DIM REMOVED AND REPLACED BATTERY PACK IAW AMM 33-51-66-960-8 05. REMOVED AND REPLACED POWER SUPPLY IAW AMM 33-51-06-9 60-806. OPS CHECKED GOOD IAW AMM 33-51-00-710-801.SDR CALA2017032100662Ufi · faultyLOW PRESSURE LIGHT FOR THE FUEL PUMP LIGHT ON CENTER TANK, RIGHT PUMP REPLACED RT CENTER UFI AND RAM REF AMM28-22-19. RAN PUMP, CHECKED OK.SDR CALA2017032000660Skin · crackedLEFT HORIZONTAL STAB LOWER SKIN CRACK AT STA 138.70 I/B OF DRAIN HOLE. INSTALLED REPAIR PER SRM 55-10-01, REPAIR 11.SDR CALA2017031700639Battery Pack · inoperativeR2 DOOR, OVERHEAD, SIDE LIGHT AT GALLEY, AND OVERHEAD BINS 31 FED, 36FED, AND 38 ABC EMERGENCY LIGHTS ARE INOPERATIVE. R & R THE BATTERY PACK M1672 IAW AMM33-51-06, OPS CHECKED GOOD.SDR CALA2017031700613Lamp · burned outLAMP FOR EXIT SIGN ON OVERWING EXIT HATCH ROW 21 DEF IS INOPERATIVE. REPLACED THE LAMP, OPS CHECKED GOOD IAW AMM 33-21-00-9 60-801.SDR CALA2017031700600Warning Message · false activationWITH RIGHT CENTER BOOST PUMP ON, RECEIVED A FUEL IMBALANCE ON NR 1 INDICATOR. CROSSFEED WAS CLOSED. EMERGENCY DECLARED. ACCOMPLISHED FIM TASK 28-21-00-810-815. NO FUEL TRANSFER NOTED, CROSSFEED VALVE AND BOOST PUMPS OP CHECKED GOOD.SDR CALA2017031700605Skin · damagedRT HORIZONTAL STAB LOWER SKIN AT HSS 101.90. INSTALLED A REPAIR DOUBLER IAW SRM 55-10-01, REPAIR 11.SDR CALA2017031700604Skin · crackedLEFT HORIZONTAL STABILIZER LOWER SKIN AT HSS 101. NINTY INCHES FROM TRAILING EDGE HAS A .25 INCH CRACK. VERIFIED CRACK USING HFEC PART 651-00-00 PROCEDURE 23. INSTALLED A REPAIR DOUBLER IAW SRM 55-10-01, REPAIR 11.SDR CALA2017031000569Fitting · brokenEMERGENCY EXIT LITE ABOVE FLIGHT DECK DOOR HAS A BROKEN CLIP AND WILL NOT STAY ON. REPLACED LITE ASSY OP CHKS NORMAL.SDR CALA2017031000567Battery · dischargedEMER FLASHLIGHT AT DOOR 2R CHARGE/READY LIGHT NOT BLINKING. REPLACED FLASHLIGHT BATTERY ON INBD ONE AT 2R, OPS CHECKS GOOD.SDR CALA2017031000560Unknown · odorF/A AND PASSENGERS REPORT SMELL OR BURNING RUBBER INTERMITTENTLY AROUND ROWS 23 24 25. PERFORMED TASK 05-51-26-800-801C1 PARAGRAPH A,B,C. NO AIRCRAFT DAMAGE FOUND. NO ODOR PRESENT. CABIN CREW REPORTED ONLY A MOMENTARY ODOR AND NOTED NO OTHER OCCURRENCE AND CUSDR CALA2017031000557Pump · faultyLOST HYD B SYSTEM. EMERGENCY DECLARED. SERVICED B SYSTEM HYDRAULICS TO FULL 7 GALLONS. WITH ENGINE NR 2 RUNNING FOR 30 MIN AND THEN WITH B SYSTEM ELECTRIC PUMP NO EXTERNAL HYDRAULIC LEAKS FOUND. B SYSTEM FLUID STARTED AT 105% BEFORE ENGINE RUN AND DROPPED TO SDR CALA2017031000556Skin · dentedFUSELAGE SKIN HAS A DENT AFT OF L-1 DOOR AT STA 383 BETWEEN STR- 7L AND STR-8L. ACCOMPLISHED REPAIR REF EC/RA 5330-05986.SDR CALA2017030500543Light · inoperativeEXTERIOR EMERGENCY LIGHT AT RIGHT LOWER FUSELAGE AFT OF WING IS INOP. RELAMPED RT LOWER BODY EMERGENCY LIGHT, OPS GOOD.SDR CALA2017030500542Lens · brokenROW 28ABC EMERGENCY EXIT PATH LIGHT LENS BROKEN. REPLACED LENS COVERSDR CALA2017030500536Tire · wornSEVERE NOSE WHEEL VIBRATION ON TAKEOFF AND DURING LANDING. EMERGENCY DECLARED. REMOVED AND REPLACED BOTH NOSE GEAR TIRES PER AMM 32-45-21 000-8 01,400-801. RIGHT NOSE TIRE REMOVED SHOWING CORD. LUBED NOSE GEAR LINKAGE REF AMM 12-21-21. AC OK FOR SERVICE.SDR CALA2017030400527Light · unsecureEMERGENCY LIGHT DOES NOT TURN ON 21C. THE LIGHT IS HANGING DOWN. SECURED THE EMERGENCY LIGHT.SDR CALA2017030400526Lamp · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE. OVERHEAD BIN BULLNOSE BETWEEN ROWS 3EF AND 4EF. REPLACED THE LAMPS. OPS CHECKED GOOD.SDR CALA2017030400525Battery · dischargedFLASHLIGHT NO LED INDICATOR LIGHT. REMOVED AND REPLACED EMERGENCY FLASHLIGHT BATTERY AT FWD ATTENDANT STATION IAW MM 25-64-00-906-806.SDR CALA2017022700505Fuel Cell · overservicedFUEL COMING FROM RIGHT WING TIP AND F/A REPORT FUEL ODOR IN GALLEYS. TANK WAS OVERSERVICED AND FUEL CAME FROM SURGE TANK DURING TAXI, REDISTRIBUTED FUEL. NO DEFECTS NOTED TANK WAS OVERSERVICED AND FUEL CAME FROM SURGE TANK DURING TAXI, REDISTRIBUTED FUEL. NO SDR CALA2017022700500Lamp · inoperativeLEFT OVERWING, AFT EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMP IAW MM 33-51-03. OPS C HECKED GOOD.SDR CALA2017022600495Window Frame · crackedR1 WINDOW RT UPPER FUSELAGE CUTOUT SUSPECT CRACK. PERFROMED INTERIM REPAIR TO R1 WINDOW PER ECRA 5610-01388.SDR CALA2017022600492Lens · brokenEMERGENCY FLOOR PROXIMITY LIGHT DOES NOT TURN ON 111 LENS IS BROKEN. REMOVED AND REPLACED BROKEN LENS COVER, FUNCTIONS NORMALLY.SDR CALA2017022600489Outflow Valve · malfunctionedALT WARNING HORN 35700 CABIN GOT TO 15500 O2 MASKS DEPLOYED PERFORMED DIGITAL CABIN PRESSURE CONTROLLER (DCPC) BITE PROCEDURE FOR BOTH NR 1 AND NR 2 CPC REF AMM 21-31-00-810-801. FOUND NO EXISTING FAULTS FOR BOTH CONTROLLERS AND NO FAULT HISTORY FOR THE NR 1 C
Back to Boeing 737-824