SDR CALA2014102901401Frame · crackedFUSELAGE FRAME STATION 440L HAS A CRACK IN THE WEB BETWEEN STRINGER S 8LT & 9LT. FABRICATED & INSTALLED REPAIR ANGLES IAW EA 5310-047160 REV H OPT 2.SDR CALA2014102901399Frame · crackedFUSELAGE FRAME STATION 380RT HAS A CRACK IN THE WEB BETWEEN STRINGER 8RT & 9RT. REPAIRED CRACK IN FRAME IAW EA 5310-04716 REV H OP 2.SDR CALA2014102401393Rib · crackedLEFT STABILIZER IN SPAR RIB, STAB STATION 92.70 STIFFENER 2 CRACKED. REPAIRED RIB IAW SRM 55-10-09 REPAIR 4. INSTALLED DOUBLER IAW SRM 55-10-01 REPAIR 11. PLACED ON DIP INSPECTION THRESHOLD 56,000 FLIGHT CYCLES TO INSPECT EXTERNAL DOUBLER & SPAR CHORD UNDERSDR CALA2014102401392Skin · crackedLEFT HORIZONTAL STAB LOWER SKIN HAS 3 CRACK ANOMALY INDICATIONS AT RIB 6 STATION 129.50 AREAS MARKED. REPAIRED HORIZONTAL STAB SKIN IAW SRM 55-10-01 REPAIR 11. PLACED ON DIP INSPECTION THRESHOLD 56,000 FLIGHT CYCLES TO INSPECT DOUBLER & SPAR CHORD UNDER DOUBSDR CALA2014102401391Frame · crackedFOUND CRACK INDICATION ON INBD RIVET HOLE FRAME 400R. REPAIRED CRACK IAW ECRA 5310-06287. ACCOMPLISH INSPECTION REQUIREMENTS ON OR BEFORE THE ACFT REACHING 50,000 TOTAL FLIGHT CYCLES. PLANNING TO CONTACT ENGINEERING AFTER 43,000 CYCLES BUT BEFORE 44,000 TOTSDR CALA2014102401390Frame · crackedCABIN FRAME INSPECTION FOUND CRACK INDICATION ON INBD RIVET STATION 400L. REPAIRED CRACK IAW ECRA 5310-06287. ACCOMPLISH INSPECTION REQUIREMENTS ON OR BEFORE THE ACFT REACHING 50,000 TOTAL FLIGHT C CYCLES. PLANNING TO CONTACT ENGINEERING AFTER 43,000 CYCLESSDR CALA2014102401389Frame · crackedFOUND CRACK INDICATION ON INBD RIVET HOLE FRAME 440R. REPAIRED CRACK IAW ECRA 5310-06287. ACCOMPLISH INSPECTION REQUIREMENTS ON OR BEFORE THE ACFT REACHING 50,000 TOTAL FLIGHT CYCLES. PLANNING TO CONTACT ENGINEERING AFTER 43,000 CYCLES BUT BEFORE 44,000 TOTSDR CALA2014102401388Frame · crackedCABIN FRAME INSPECTION FOUND CRACK INDICATION ON INBD RIVET STATION 440L. REPAIRED CRACK IAW ECRA 5310-06287. ACCOMPLISH INSPECTION REQUIREMENTS ON OR BEFORE THE ACFT REACHING 50,000 TOTAL FLIGHT CYCLES. PLANNING TO CONTACT ENGINEERING AFTER 43,000 CYCLES BSDR CALA2014102401387Frame · crackedFOUND CRACK INDICATION ON INBD RIVET HOLE FRAME 480R. REPAIRED CRACK IAW ECRA 5310-06287. ACCOMPLISH INSPECTION REQUIREMENTS ON OR BEFORE THE ACFT REACHING 50,000 TOTAL FLIGHT CYCLES. PLANNING TO CONTACT ENGINEERING AFTER 43,000 CYCLES BUT BEFORE 44,000TOTASDR CALA2014102401386Frame · crackedCABIN FRAME INSPECTION FOUND A CRACK INDICATION BS 867. REPAIRED IAW ECRA 5310-06287.SDR CALA2014102401385Frame · crackedCRACK INDICATION ON FRAME BS 827. REPAIRED IAW ECRA 5310-06287.SDR CALA2014102401384Frame · crackedIAW EA 5310-04716 OP2 FOUND CRACK INDICATION ON INBD RIVET HOLE FRAME 867R. REPAIRED IAW ECRA 5310-06287. ACCOMPLISHED INSPECTION REQUIREMENTS ON OR BEFORE THE ACFT REACHING 50,000 TOTAL FLIGHT CYCLES. PLANNING TO CONTACT ENGINEERING AFTER 43,000 CYCLES BUTSDR CALA2014102401383Stringer · corrodedFOUND CORROSION ON INSIDE CHANNEL STRINGER 28L AT STATION 500 TO 500A. CUT OUT DAMAGED AREA & INSTALLED REPAIR IAW ECRA 5310-06292 PART 1. INITIATED DIP CONTROL 30246 TO REINSPECT BEFORE 50000 FLIGHT CYCLES IAW PART 2. SEE ATTACHED 44.0008 FORM.SDR CALA2014102401382Stringer · corrodedFOUND CORROSION ON INSIDE CHANNEL STRINGER 28R AT STATION 500 TO 500 A. CUT OUT DAMAGED AREA & INSTALLED REPAIR IAW ECRA. NEED TO UPDATE DIP TO CORRECT CONTROL 30242 5310-06292 PART 1. INITIATED DIP CONTROL 30246 TO REINSPECT BEFORE 50000 FLIGHT CYCLES IAW SDR CALA2014102401381Stringer · corrodedFOUND CORROSION ON INSIDE CHANNEL STRINGER 28L AT STATION 500 TO 500 C. CUT OUT DAMAGED AREA & INSTALLED REPAIRS IAW ECRA 5310-06292 PART 1. INITIATED DIP CONTROL 30247 TO REINSPECT BEFORE 50000 FLIGHT CYCLES IAW PART 2. SEE ATTACHED 44.0008 FORM.SDR CALA2014102401380Stringer · corrodedFOUND CORROSION ON INSIDE CHANNEL STRINGER 28L AT STATION 480 TO 500. CUT OUT DAMAGED AREA & INSTALLED REPAIR IAW ECRA. NEED TO UPDATE DIP CONTROL TO 30244 5310-06292 PART 1. INITIATED DIP CONTROL 30246 TO REINSPECT BEFORE 50000 FLIGHT CYCLES IAW PART 2. SESDR CALA2014102401379Stringer · corrodedFOUND CORROSION ON INSIDE CHANNEL STRINGER 28R AT STATION 500. CUT OUT DAMAGED AREA & INSTALLED REPAIR IAW ECRA 5310-06292 PART 1. INITIATED DIP CONTROL 30248 TO REINSPECT BEFORE 50000 FLIGHT CYCLES IAW PART 2. SEE ATTACHED 44.0008 FOR M.SDR CALA2014102401369Pin · not seatedSUPPORT TASK ROW 3AB EMER LIGHT INOPERATIVE. TROUBLE SHOT THE SYS & FOUND UNSEATED PIN IN CONNECTOR FOR SEAT 3AB. RESEATED PIN IAW SWPM 20-42-02. SYS CHECKED OK.SDR CALA2014102101368Fuel Control · faultyAPU OTBD SHUTDOWN INFLIGHT DUE TO AN OVER SPEED. AFTER TROUBLESHOOTING R & R APU FUEL CONTROL UNIT IAW AMM 49-11-000-801 & AMM 49-31-11-400-801. R & R APU ECU IAW AMM 49-61-12. OPERATIONS CHECKED GOOD.SDR CALA2014102101367Unknown · malfunctionedFOR SDR REPORTING POWER DOWN ACFT FOUND EMER LIGHTS REMAINING ON WITH EMER SWITCH IN THE OFF POSITION. IAW GMM 04-02-16 PG 5 ITEM 17 REF NON-ROUTINE 4352043 CORRECTIVE ACTION. EMER LIGHTS SYS OPERATIONS CHECK IAW AMM 33-51-00-720-801. SYS TESTED GOOD.SDR CALA2014102101366Battery · dischargedSUPPORT TASK EMER PATH LIGHTING INOPERATIVE IN 1ST CLASS. R & R BATTERY FOR M1674 PACK & PERFORMED OPERATIONS CHECK IAW AMM 33-51-06. TESTED OK REF BATTERY SN OFF 38340 & BATTERY SN ON 140913.SDR CALA2014102101365Skin · crackedRIGHT HORIZONTAL STABILIZER LOWER SKIN SHOW SIGN OF CRACK ABNORMALLY AT STATION 101.90 THE 3RD RIB INBD. REMOVED DAMAGE & INSTALLED REPAIR DOUBLER IAW SRM 55-10-01 REPAIR 11. DIP INITIATED FOR INSPECTION THRESHOLD OF 56,000 FLIGHT CYCLES AFTER REPAIR INSTALLSDR CALA2014102101357Battery Pack · dischargedR1 DOOR EXTERIOR EMER LIGHT INOPERATIVE. REMOVED & INSTALLED BULB AT R1 DOOR EXTERIOR IAW AMM 3 3-51-04. REMOVED BATTERY PACK PN 0717-01-100, SW 43174. INSTALLED BATTERY PACK SN 78971 IAW AMM 33-51-06. OPERATIONS CHECKED GOOD. BATTERY PACK LOCATION STATIOSDR CALA2014101501349Light · inoperativeEMERGENCY LIGHTS ON LOWER FUSELAGE RT & LT INOPERATIVE. RELAMPED LT & RT OVERWING ESCAPE GND ILLUMINATION LIGHTS. OPERATIONS CHECKED GOOD IAW AMM 33-51-04 STATION 727F & 11 RT & LT SIDE USING TWO EACH PN 767 BULBS.SDR CALA2014101501348Battery Pack · dischargedEMERGENCY LIGHT INOPERATIVE AT SEAT ROW 1 AB. R & R BATTERY CHARGER & BATTERY PACK IAW AMM 33-51-06. OPERATIONS CHECKED GOOD IAW 33-51-00 FOR EMER LIGHT AT SEAT ROW 1 AB. BATTERY CHARGER PN D717-02-001 OUT SN 29370 IN 116865. BATTERY PACK PN 717-01-0100 SN SDR CALA2014101501347Transmitter · faultyFLAP DISAGREE WHEN FLAPS SET FOR LANDING. FLAPS STOPPED BETWEEN 2 & 5. RAN CHECKLIST & USED ALTERNATE FLAPS SWITCH TO LOWER FLAPS 15. REPLACED LT FLAP POSITION TRANSMITTER T427 IAW AMM 27-58-01-4 00-801 & ADJUST TEST AMM 27-58-01-820-801. RII INSP 10Y70. RSDR CALA2014101501345Transmitter · faultyTRAILING EDGE FLAPS DID NOT EXTEND PAST 1, USED ALT FLAP EXTENSION. R & R FLAP POSITION TRANSMITTER RT SIDE IAW AMM TASK 27-58-01-000-801 & 27-58-01-400-801 CHECK OPERATIONS WORKS GOOD, ACFT OK TO CONTINUE.SDR CALA2014101501344Light · inoperativeLEFT AFT EMER EXIT WINDOW LIGHT INOPERATIVE. REMOVED BULB AT AFT LT OVERWING EXIT. INSTALLED NEW BULB. OPERATIONS CHECKED GOOD IAW AMM 33-51-01.SDR CALA2014101301341Oxygen Gen · unsecureDURING DROP TEST FOUND 1C EA 02 CANISTER NOT MOUNTED. RII SDR REMOUNTED 1L FLIGHT ATTENDANT OXYGEN GEN WITH MFG DATE 6-2008 IAW AMM 3 5-22-41. WHEN PANEL OPENED OXYGEN GEN FELL OUT WITH CLAMPS & ONE SCREW. INSTALLED NEW HARDWARE & SECURED THE GEN & RESTOREDSDR CALA2014101301339Latch · out of positionO2 MASK DID NOT DROP DURING TEST AT FLIGHT ATTENDANT STATION DOOR 2L. FOUND DOOR LATCH LEVER INCORRECTLY CLOCKED WITH LATCH ACTUATOR PLUNGER. RESET & GND TEST IAW AMM 35-22-00. OPERATIONS CHECKED NORMAL, RESTORED TO SERVICE.SDR CALA2014101301337Bulkhead · crackedCRACK FOUND ON VERTICAL PRESS WEB REAR SPAR BETWEEN RBL40 & RBL 45.64. REPAIRED IAW SRM 57-10-10 REPAIR 3. ISSUE A DIP TO PERFORM AN INSPECTION THRESHOLD OF 56,000 FLIGHT CYCLES AFTER REPAIR INSTALLATION & REPEAT INSPECTION 36,000 FLIGHT CYCLES HFEC & 36,000SDR CALA2014100901336Battery Pack · dischargedSUPPORT TASK RT AFT EMER EXIT LIGHTS WILL NOT ILLUMINATE. REMOVED BATTERY PACK AD-D717-01-100 SN 93814. REPLACED BATTERY PACK WITH PN AD-D717-01-100 SN 140911 IAW AMM 33-51-06. OPERATIONS CHECKED GOOD.SDR CALA2014100901335Pump · leakingTOTAL LOSS OF SYS B HYD. NR 2 ENG HYD PUMP WAS TURNED OFF ACCORDING TO QRH PROCEDURES. FOUND NR 2 ENG HYD PUMP SHAFT SEAL LEAKING. R & R NR 2 EDP IAW AMM 29-11-11 & CASE DRAIN FILTER IAW AMM 29-11-51. SERVICED RESERVOIR TO FULL. LEAK CHECKED GOOD. OK TO SDR CALA2014100901334Light · inoperativeSUPPORT TASK RT OVERWING EXIT LIGHTS WILL NOT ILLUMINATE. INTERIOR AFT R & R RT INTERIOR EMER OVERWING EXIT AFT LIGHT BULB IAW AMM 33-51-00. OPERATIONS CHECKED GOOD.SDR CALA2014100901333Light · inoperativeSUPPORT TASK RT WING AFT EMER LIGHT IS INOPERATIVE. R & R RT WING AFT EMER LIGHT IAW AMM 33-51-04. OPERATIONS CHECKED GOOD.SDR CALA2014100901332Battery Pack · dischargedSUPPORT LT OVERWING EMER EXIT LIGHTS WILL NOT OPERATE. REMOVED BATTERY PACK PN AD-D717-01-100 SN-64248. REPLACED WITH BATTERY PACK PN-AD-D717-01-100 SN-149004 IAW AMM 3 3-51-06. OPERATIONS CHECKED GOOD.SDR CALA2014100901331Stringer · corrodedFORWARD CARGO LT STRINGER 27 BAY 10 - 11 STRINGER CHANNEL FWD & AFT OF 500E ROW OF FASTENERS WITH LIGHT CORROSION. REPLACED STRINGER SECTION AT STRINGER 27 LT FROM STATION 500D & 10 INCHES TO 500I + 10 INCHES. INSTALLED STRINGER SPLICE IAW SRM 53-00-03 REPAISDR CALA2014100801327Circuit Breaker · burnedMULTIPLE ELEC ISSUES & FAILURES DURING ARRIVAL. VNAV FAILED TO FOLLOW PATH & AIRSPEED. YAW DAMP TRIPPED OFF. ENG NR 1 ELEC PUMP LOW PRESS LIGHT ON & ELEC TRIM FAILED. TR UNIT LIGHT ON, BOTH OVERWING EXIT LIGHTS ON & AUTO PRESS FAILED. TROUBLE SHOT FOUND GSDR CALA2014100801319Battery Pack · dischargedEMERGENCY LIGHTS OPERATIONS CHECK AT POSITION M1670 FAILED TEST. R & R BATTERY PACK M1670. PERFORMED OPERATIONS CHECK, EMER LIGHTING FOUND NORMAL IAW AMM 33-51-06.SDR CALA2014100801317Frame · crackedCABIN FRAME INSPECTION, FOUND CRACK INDICATION INBD RIVET STATION 727BL. REPAIRED IAW EA 5310-04716 REV H.SDR CALA2014100801316Engine · failedNUMBER 1 ENG FAILED INFLIGHT. PERFORMED QRH & LANDED. EGT SHOWED 942 SLIGHT SHUDDERING INITIALLY, NO PROBLEM CONTROLLING ACFT. FOUND METAL IN TAILPIPE. REPLACED NR 1 ENG WITH WC 29-7100-1-0900 & 29-7100-1-4900. NO LEAKS NOTED, IDLE & ECC TESTED ALL GOOD.SDR CALA2014100601310Frame · crackedFOUND CRACK INDICATION ON INBD RIVET HOLE FRAME 380R. REPAIRED IAW EA 5310-04716 OP2.SDR CALA2014100601309Frame · crackedOP 2 CABIN FRAME INSPECTION. FOUND CRACK INDICATION ON INBD RIVET STATION 480 LT. REPAIRED FRAME IAW EA 5310-04716 REV H OP 2.SDR CALA2014100601308Frame · crackedOP 2 CABIN FRAME INSPECTION. FOUND CRACK INDICATION ON INBD RIVET STATION 500AL. REPAIRED FRAME AT STATION 500AL BETWEEN STRINGER 8L & 9L. SEE ALL TASKS & WIPS FOR PARTIAL WORK ACCOMPLISHED IAW EA 5310-04716 REV H OP 02.SDR CALA2014100601307Battery Pack · dischargedSUPPORT L1 DOOR EXTERIOR EMER LIGHT INOPERATIVE ON INBOUND. TROUBLESHOOTING REVEALED FAULTY BATTERY PACK. R & R BATTERY PACK IAW AMM 33-51-06. OPERATIONS CHECKED GOOD IAW AMM 33-51 -06.SDR CALA2014100601306Frame · crackedFOUND CRACK INDICATION ON INBD HOLE FRAME 500CR. REPAIRED FRAME AT STATION 500C RT BETWEEN STRINGER 8R & 9R. SEE ALL TASKS & WIPS FOR PARTIAL WORK ACCOMPLISHED IAW EA 5310-04716 REV H OP 02.SDR CALA2014100601305Frame · crackedFOUND CRACK INDICATION ON INBD RIVET HOLE RT FRAME STATION 500A. REPAIRED IAW EA 5310-04716 OP 2 REV H.SDR CALA2014100201296Frame · crackedIAW EA 5310-04716 OP 2 FOUND CRACK INDICATION ON INBD RIVET HOLE AT FRAME 500D RT. REPAIRED FRAME IAW EA 5310-04716 REV H.SDR CALA2014100201297Frame · crackedIAW EA 5310-04716 OP2 CABIN FRAME INSPECTION. FOUND CRACK INDICATION ON INBD RIVET AT STATION 500D LT. REPAIRED FRAME IAW EA 5310-04716 REV H.SDR CALA2014092901289Transmitter · failedON FINAL FLAPS STOPPED WORKING 0+1 DEGREE FLAPS. ACCOMPLISHED CHECKLIST. R & R FLAT POSITION TRANSMITTER RT IAW AMM 27-5 8-01-000-801 & 27-58-01-400-801. PERFORMED LAND VERIFY AMM 22-11- 00-700-801. ALL TESTS PASSED. IAW 7729885 FOR AUTO THROTTLES NO AUTO
Back to Boeing 737-824