Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2016011114720Fuel Nozzle · failedWHILE PERFORMING T/C 78273000, FOUND NR 1 ENGINE FAULT MSG 73-31371 ECONOMIC FAULT UPPER EGT SECTORS. ACFT GROUNDED. R & R FUEL NOZZLES REF POWER PL-73CMPT-07267-2.SDR ASAA2016011014846Floorbeam · corrodedFWD PIT CENTER FLOOR SUPPORT CORRODED, FROM TRANSITION PANEL TO TRANSITION PANEL, BS 500I. ACFT GROUNDED. REMOVED CENTER SUPPORT CORRODED IAW SRM 51-40-02, RECEIVED NEW SUPPORT ANGLE, PN 143A9485, REV F, INSTALLED CENTER SUPPORT ANGLE IAW SRM 51-40-02 PO 854SDR ASAA2016011014791Channel · corrodedFWD PIT RT SIDE TRANSITION PANEL CORRODED BS 500F-BS 500I. ACFT GROUNDED. REMOVED DAMAGE CHANNEL SECTION BS 500F TO 500I IAW SRM 51-40-02, MATERIAL ID FOR FABRICATION. BAC 1496-444 IAW SRM 53-30-53-01, FIG 2, TABLE 2, FABRICATED NEW SECTION IAW SRM 53-00-53SDR ASAA2016011014721Warning Message · activatedWHILE ACCOMPLISHING TASK CARD NR 78273000, INTEROGATE THE FMC CDU FOR ENGINE FAULTS, FOUND MSG NR: 73-31161, THE MECHANICAL OVERSPEED PROTECTION SIGNAL IS OUT OF RANGE, NR 1 ENGINE. THIS IS A LONG TIME FAULT. ACFT GROUNDED. ACCOMPLISHED FIM 73-21, TASK 801, SDR ASAA2016011014719Warning Message · false activationFMC DISAGREE ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. FMCS RESTORED NORMAL.SDR ASAA2016011014718Terminal · looseON FIRE TEST NR 2 ENGINE FIRE TEST FAILED. ACFT GROUNDED. PERFORMED NR 2 ENGINE/APU FIRE DETECTION MODULE BITE PROCEDURE, REF FIM 26-10, TASK 801. NO FAULTS FOUND. ACCOMPLISHED LOW DETECTORS RESISTANCE, REF FIM 26-10, TASK 810. FOUND M1757 UPPER FAN DETECTORSDR ASAA2016011014717Lens · looseEXIT SIGN FROM WING EMERGENCY EXITS NEEDS TO BE RE-SECURED. ACFT GROUNDED.
RE-SECURED EXIT SIGN AS REQUIRED.SDR ASAA2016011014716Satcom · malfunctionedSAT COMM PROMPT ON FMS MENU IS MISSING. ACFT GROUNDED. RECYCLED SATCOM C/B. SATCOM PROMPT IS NOW PRESENT ON FMS. SATCOM OPS CHECK GOOD IAW AMM 23-15-00.SDR ASAA2016011014715Satcom · lockedSATCOM LOCKUP ON GROUND DURING POWER TRANSFER. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. SATCOM RESTORED NORMAL.SDR ASAA2016011014714Satcom · lockedSATCOM LOCKUP OCCURRED DURING POWER TRANSFER. PERFORMED QRH PROCEDURE AND RESTORED SATCOM. ACFT GROUNDED. ACCOMPLISHED SATCOM SYSTEM TEST REF AMM 23-15-00-730-801. OPS TEST NORMAL ON BOTH SATCOM 1 AND 2.SDR ASAA2016011014713Warning Light · false activationCABIN CONTROLLER ZONE TEMP ILLUMINATES ON RECALL, GOES OUT ON MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED ZONE TEMP CONTROLLER BITE IAW FIM 21-62-801, RT CONTROLLER SHOWED FLT DECK TRIM VALVE FAULT FOR PREVIOUS FLIGHT. CLEARED FAULT, OPERATED PACKS, PZSDR ASAA2016010914705Probe · failedNR 1 ENGINE, PERFORMED TC 78273000, FOUND FAULT 73-31371. UPPER EGT SECTORS READING HIGH, ECONOMIC FAULT, REPAIR WITHIN 500 HOURS. ACFT GROUNDED. UNABLE TO DUPLICATE DEFECT. NR 1 ENGINE ELECTRONIC ENGINE CONTROL BITE IAW T/C 78273000 SHOWED NO INSTANCES OF SDR ASAA2016010914930Floor Panel · crackedPARTS RACK, AFT PIT FLOOR PANEL 140BF CRACKED IN 2 AREAS. ACFT GROUNDED. FABRICATED AFT PIT FLOOR PANEL 140BF IAW BAC DWG 453A2610, REV C ALODINED & PRIMED IAW SRM 51-20-01.SDR ASAA2016010914929Floor Panel · corrodedFWD CARGO FLOOR PANEL 120AF CORRODED IN SEVERAL AREAS. ACFT GROUNDED. FABRICATED NEW FLOOR PANEL 120AF IAW DWG 453A1610, REF F. ALODINE TREATED AND RESTORED PRIMER FINISH IAW SRM 51-20-01 AND AMM 51-21-72.SDR ASAA2016010914788Floor Panel · corrodedFWD CARGO FLOOR PANEL 120DF CORRODED IN SEVERAL AREAS. ACFT GROUNDED. FOUND TO BE OUT OF LIMITS EXCEEDED 3" MAXIMUM ALLOWED IAW SRM 53-00-53. MATERIAL ID IS 2024-T3, .071 IAW DWG 453A1610, REV T, PO 856649-1, FABRICATED NEW FLOOR PANEL IAW DWG 453A1610, REV FSDR ASAA2016010914787Floor Panel · crackedFWD CARGO FLOOR PANEL 120CF CRACKED AND CORRODED IN SEVERAL AREAS. ACFT GROUNDED. AFTER FURTHER INVESTIGATION, CORROSION EXCEEDS ALLOWABLE LIMITS OF 3" CRACKS NOT ALLOWABLE REPAIRS OUT OF LIMITS IAW SRM 53-00-53, MATERIAL ID FOR NEW PANEL 2024-T3 0.071 IAWSDR ASAA2016010914785Floor Panel · corrodedPARTS RACK, AFT PIT FLOOR PANEL 140AF CORRODED IN SEVERAL AREAS. ACFT GROUNDED. MATERIAL ID FOR PANEL IS 2024T3 .071 PO 851953.2 IAW BAC DWG 453A2610 FABBED FLOOR PANEL IAW DWG 453A7610, ALODINED & PRIMED IAW SRM 51-20-01. REMOVED DOT H193 PART MARKED IAW DSDR ASAA2016010914708Indicator · trippedWHILE PERFORMING TSR817378 FOUND ENGINE NR 2 SUPPLY OIL FILTER POP-OUT INDICATOR EXTENDED. ACFT GROUNDED. PERFORMED OIL SUPPLY FILTER POP-OUT INDICATOR INSPECTION. NO CONTAMINATION FOUND ON SUPPLY OIL FILTER FOR ENGINE NR 2. REF AMM 79-00-00-200-805-F00. PERSDR ASAA2016010914701Warning Message · false activation"FMC DISAGREE" ANNUNCIATION. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. FMCS RESTORED NORMAL.SDR ASAA2016010914693Battery Pack · failedREF T/C 78233000, 3 EA BATTERY PACKS FAIL THE 15 MIN HOLD CHECK. L-1 DOOR EMERGENCY EXIT SIGN, LT OVERWING EMERGENCY EXIT LIGHT, L-2 DOOR EMERGENCY EXIT SIGN. ACFT GROUNDED. R & R 3 EA EMERGENCY BATTERY PACKS, OPS NORMAL REF AMM 33-51-06. BATTERY PACKS NOW SDR ASAA2016010914688Oil Cooler · leakingNR 2 IDG FREQUENT SERVICING, ACFT GROUNDED. FOUND IDG NR 2 LEVEL NOT PRESENT IN SIGHT GLASS. FOUND IDG AIR/OIL COOLER EXTERNAL LEAK WITH EVIDENCE DRIPPING FROM THRUST REVERSER SLEEVE. CLEANED ALL OIL FROM THRUST REVERSER AND ALL EFFECTED AREAS. R & R ENGINE NSDR ASAA2016010914687Satcom · lockedSATCOM LOCKUP DURING POWER TRANSFER. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. SATCOM RESTORED NORMAL.SDR ASAA2016010914685Satcom · lockedSATCOM LOCK UP, ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. SATCOM RESTORED NORMAL.SDR ASAA2016010914676Valve · failedON MASTER CAUTION RECALL CONTROLLER CABIN ZONE TEMP ILLUMINATES, RESETS WITH MASTER CAUTION RESET. ACFT GROUNDED. NR 2 PACK/ZONE TEMP CONT BITE INDICATES FLT DK TRIM VALVE FAULT, REF AMM 21-61-00. REPLACED FLIGHT DECK TRIM VALVE, INSTALLATION TEST NORMAL REFSDR ASAA2016010814707Fuel Nozzle · faultedPERFORMED TASK CARD 78273000. FOUND NR 2 ENGINE FAULT 73-31372, "UPPER EGT SECTORS READING HIGH", ECONOMIC FAULT, REPAIR WITHIN 500 FLIGHT HRS. ACFT GROUNDED. R & R NR 2 ENGINE UPPER 11 FUEL NOZZLES IAW POWERPLANT 73CMPT-07267-2. PERFORMED GROUND VERIFICATSDR ASAA2016010814704Engine · faultedWHILE ACCOMPLISHING T/C 78273000 FOUND NR 2 ENGINE ECONOMIC FAULT 73-31372, UPPER EGT SECTORS READING HIGH. ACFT GROUNDED. ON DEFERRAL.SDR ASAA2016010814703Engine · faultedIAW T/C 78273000, FOUND NR 1 ENGINE WITH ECONOMIC FAULT 73-31371. UPPER EGT SECTORS READING HIGH. ACFT GROUNDED. ON DEFERRAL.SDR ASAA2016010814680Servo · malfunctionedON TAKEOFF HIT TOGA THROTTLES STARTED TO COME UP NR 2, NR 1 THEN AUTOTHROTTLE DISCONNECTED. AFTER TAKEOFF WE TRIED TO CONNECT THROTTLES TWICE MORE. NOT SUCCESSFUL. LEFT A/T OFF REMAINDER OF FLIGHT. ACFT GROUNDED. R & R NR 2 ASM AND OPS TEST GOOD, IAW AMMSDR ASAA2016010814702Regulator · failedON CLIMB OUT "RT" DUCT PRESSURE 20 PSI, "LT" 50 PSI, LT FLUCTUATING =- 5PSI, 45 TO 55PSI, AT LEVEL OFF AT 360 BOTH STABILIZED AT 42 PSI. ACFT GROUNDED. ACCOMPLISHED NR 1 ENGINE BLEED AIR HEALTH CHECK IAW NG-36WC-00001. R & R NR 1 ENGINE HIGH STAGE REGULATORSDR ASAA2016010814690Actuator · failedDURING ENGINE NR 1 START THE SPAR VALVE CLOSED LIGHT REMAINED BRIGHT WHILE START LEVER WAS IN IDLE DETENT. AFTER STARTER CUTOUT ENGINE VALVE CLOSED LIGHT WENT BRIGHT THEN DIM. THE ENGINE SHUTDOWN AT THAT TIME. SPAR VALVE LIGHT REMAINS BRIGHT WITH THE START SDR ASAA2016010814689Idg · failedON DESCENT A/P DISENGAGED. NR 2 SOURCE OFF LIGHT ILLUMINATED. FOLLOWED QRH PROCEDURE. NR 2 GENERATOR WOULD NOT RE-ENGAGE. APU POWERING NR 2 SOURCE. ACFT GROUNDED. REMOVED NR 2 IDG IAW AMM 24-11-11-000-801 AND INSPECTED FILTER FOR CONTAMINATION REF AMM 24-1SDR ASAA2016010714786Skin · crackedCRACK INDICATION AT BS 129.50 RT LOWER HORIZONTAL SKIN PANEL 16" FORWARD OF REAR SPAR. MARKED IN RED. ACFT GROUNDED. REMOVED RT L/E PANEL AND STAB TIP CAP ASSY IAW AMM 27-41-21. ROUTED OUT DAMAGED AREA AND REPAIRED IAW SRM 55-10-01-2R-11. INSTALLED RT L/E SDR ASAA2016010714711Relay · failedWHILE ACCOMPLISHING T/C 78128006, THE LT CENTER TANK AUTO SHUTOFF FUNCTIONAL TEST FAILED. ACFT GROUNDED. R & R THE LT AUTO SHUTOFF RELAY, R936, REF WDM 28-23-11. OPS CK GOOD REF T/C 78128006.SDR ASAA2016010714686Satcom · malfunctionedDISCOVERED DURING INITIAL CRUISE SATCOM PROMPT NOT DISPLAYED. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. SATCOM RESTORED NORMAL.SDR ASAA2016010714679Autothrottle Sys · inoperativeAUTOTHROTTLE INOPERATIVE. ACFT GROUNDED. ACCOMPLISHED AUTOTHROTTLE, OPS TEST REF AMM 22-31-00 AND LWMP BITE GROUP NR 43 ALL TESTS GOOD, COULD NOT DUPLICATE AT THIS TIME.SDR ASAA2016010714662Floor Support · corrodedAFT CARGO COMPARTMENT FLOOR PANEL 140BF AFT TEE ASSY IS CORRODED. ACFT GROUNDED. REMOVED AFT CARGO COMPARTMENT FLOOR PANEL 140BF AFT TEE ASSY IAW SRM 51-40-02 AND REMOVED CORROSION IAW SRM 53-00-53. FOUND TO BE OUT OF LIMITS RECEIVED NEW TEE ASSY,
PN 146ASDR ASAA2016010614669Lens · brokenEMERGENCY LIGHT EXIT LOCATOR SIGN ON NR 1 GALLEY ADJACENT TO R1 DOOR HAS BROKEN LENS. ACFT GROUNDED. REPLACED LENS AND TESTED LIGHT ASSY IAW AMM 33-51-01-960-801. OPS NORMAL.SDR ASAA2016010614665Connector · contaminatedDURING IDG OIL CHANGE FOUND CONNECTOR PLUG TO NR 2 ENGINE DRIVEN HYDRAULIC PUMP SHUTOFF SOLENOID DISCONNECTED. ACFT GROUNDED. DP1204 TO NR 2 ENGINE DRIVEN HYD PUMP STRIPPED AT PLUG AND SOLENOID. REPLACED MW0312 NACELLE HARNESS REF AMM 71-51-03. OPS TEST GOODSDR ASAA2016010614666Wire Harness · failedDURING PDC FOUND WING ANTI-ICE LT VALVE, RT VALVE AND ENGINE ANTI-ICE COWL ANTI-ICE AND COWL VALVE OPEN LIGHTS WILL NOT TEST. ACFT GROUNDED. FOUND ENGINE 1 ANTI-ICE ENGINE AND WING CONTROLLER C/B POPPED. RESET C/B. MOVED WING ANTI-ICE SWITCH TO ON. C/B POSDR ASAA2016010614664Fire Loop · malfunctionedREQUEST VISUAL INSPECTION OF NR 2 ENGINE OVERHEAT/FIRE UPPER FAN DETECTOR LOOP AND OPS TEST OF ENGINE FIRE AND OVERHEAT DETECTION SYSTEM. ACFT GROUNDED. MOVED NR 2 ENGINE LOOP FIRE SWITCH BACK TO NORMAL. ENGINE FIRE WARNING OPS TEST NORMAL. USED IAW CHAP 5-SDR ASAA2016010614663Valve · malfunctionedON RECAL THE ZONE TEMP LIGHT FOR THE CONTROLLER CABIN ILLUMINATED. PERFORMED QRH PROCEDURE AND LIGHT WENT OUT WITH MASTER CAUTION PUSH TO RESET. ACFT GROUNDED. REPLACED THE CONTROLLER CABIN TRIM AIR MODEL VALVE ASSY REF MM 21-61-21. OPS BITES CHECK GOOD, NO SDR ASAA2016010614643Exciter · failedAPU HAS HISTORY OF NO STARTS. ACFT GROUNDED. R & R IGNITER PLUG, IGNITER PLUG LEAD AND EXCITER IGNITER UNIT IAW AMM 49-41-15, 49-41-52, 49-41-31.SDR ASAA2016010514661Channel · corrodedAFT CARGO COMPARTMENT RT TRANSITION PANEL IS CORRODED FROM BS 727I TO BS 767. ACFT GROUNDED. ACCOMPLISHED BLENDOUT OF CORRODED AREA AT THE AFT CARGO COMPARTMENT RT ZEE CHANNEL SIDEPLATE FROM BS 727I TO BS 767 IAW SRM 51-10-02 ORIGINAL MATERIAL .040 REMAINING SDR ASAA2016010514659Lamp · failedRIGHT FWD OVERWING EXIT, EMERGENCY EXIT HANDLE LIGHT INOPERATIVE. ACFT GROUNDED. RELAMPED, OP CHECKED NORMAL.SDR ASAA2016010514658Lamp · failedEXTERIOR EMERGENCY EXIT LIGHT AT AFT ENTRY DOOR INOPERATIVE. ACFT GROUNDED. REPLACED THE LAMP, OPS CHECKED NORMAL.SDR ASAA2016010514656Starter · failedENGINE NR 1 WOULD NOT START, START VALVE OPEN LIGHT NO N1, NO N2. ACFT GROUNDED. R & R NR 1 ENGINE STARTER WITH SERVICEABLE STARTER. STARTER INSTALLATION IAW AMM 80-11--01-700-801-F00, OPS LEAK CHECK GOOD. REF AMM 71-00-00-801-F00 TEST 1 & 3A OPS AND LEAK CHSDR ASAA2016010514655Wire Harness · damagedFOUND NR 1 ENGINE NACELLE WIRE HARNESS DAMAGED AT DP1202 OF HARNESS MW0312. ACFT GROUNDED. REPLACED NR 1 ENGINE NACELLE HARNESS MW0312 WITH NEW ONE. ACCOMPLISHED ENGINE TEST, TEST 1, 2, 3A, A2,13 ALL PASS NO FAULTS NOTED. REF AMM 71-00-00-800-811 & 71-51-03-SDR ASAA2016010514650Fire Handle · no testDURING OVERHEAT/FIRE TEST, NR 2 FIRE HANDLE DOES NOT ILLUMINATE AND ENGINE 2 OVERHEAT CAUTION LIGHT DOES NOT ILLUMINATE. ACFT GROUNDED. PERFORMED ENGINE/APU FIRE DETECTION BITE FOUND FAULT NR 2 ENGINE LOOP B UPPER FAN DETECTOR FAULT IAW-800 FIM 26-10-801. RESDR ASAA2016010414645Satcom · lockedSATCOM LOCK UP ON THE GROUND. ACFT GROUNDED. ACCOMPLISHED RESET PROCEDURE IAW QRH. SATCOM RESTORED NORMAL.SDR ASAA2016010414641Battery Pack · failedREF T/C 78233008, EMERGENCY LIGHT BATTERY PACK M1675 WHICH PROVIDES POWER FOR L1 DOOR EXIT SIGN, L-1 SLIDE LIGHT, AND L1 DOOR EXIT LOCATOR SIGN FAILS AFTER APPROXIMATELY 60 SECONDS OF OPERATION. ACFT GROUNDED. REMOVED AND INSTALLED NEW BATTERY AND CHARGER RE
Back to Boeing 737-890