Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2013032894286Control Valve · inoperativeLT A/C PACK LIGHT ON WITH MASTER CAUTION RECALL. LIGHT GOES OUT WITH MASTER CAUTION RESET. VERIFIED TCV DOESNT MOVE DURING BITE. R & R LT PACK TCV. OPS CK NORMAL REF MM 21-51-10.SDR ASAA2013032794298Hf Comm · unknownNR 1 HF INOPERATIVE. PERFORMED HF COMMUNICATION SYS TEST REF MM 23-11-00-730-801. NO FAULTS NOTED. PERFORMED HF COMMUNICATION SYS OPS TEST REF MM 23-11-00-710-801. NO FAULTS NOTED. SIGNIFICANT GROUND SYS VERIFICATION SUCCESSFUL. NO HISTORY FOR 90 DAYS.SDR ASAA2013032794280Apu · leakingA DIRTY SOCK ODOR OCCURRED STARTING T/O ROLL AND WAS GONE AT 20,000 FT ON CLIMB. NO ODOR DURING FLIGHT. THE ODOR REAPPEARED ON DESCENT AT 15,000 UNTIL LANDING. IT WAS DETECTED THROUGHOUT THE CABIN AND COCKPIT. ACFT GROUNDED. ACCOMPLISHED CABIN ODOR T/S IAWSDR ASAA2013032794279Indication Sys · malfunctionedDURING DESCENT, LEFT FUEL AND CENTER FUEL QTY AND TOTAL FUEL WENT BLANK FOR 15-20 SECONDS. ALL OTHER INDICATIONS NORMAL. PERFORM FIM TASK 28-41, TASK 801. NO ACTIVE FAULTS FOUND. NO HISTORY LAST 30 DAYS.SDR ASAA2013032794277Fuel Cell · icedAFTER FUELING, FUEL GAUGES READ L 8.46, CTR 22.2, R 8.51 AT PRIOR TO PUSH CHECK RT FUEL GAUGE DROPPED BETWEEN 400-500 LBS OF FUEL. ACCOMPLISHED E/A 800-28, EA-10038 FUEL QTY INDICATION SYS AFFECTED BY ICE FORMATION PROCEDURE. SUMPED CTR FUEL TANK AND WING MSDR ASAA2013032794274Unknown · unknownAUTO FAIL CAUTION LIGHT ON AT CRUISE ALTITUDE 35,000, WHEN SELECTING 37,000. SYS AUTO SWITCHED TO ALTERNATE. RAN QRH CHECKLIST 2.2 CONTINUED IN ALTERNATE MODE IAW CHECKLIST. NR 2 CONT BITE SHOWED EXISTING FAULT OFV LRU FAIL IAW FIM TASK 21-31, TASK 827. SUSDR ASAA2013032694273Idg · failedWITH ONLY NR 1 ENGINE RUNNING. NR 1 ENGINE GENERATOR KICKED OFF LINE AND WOULD NOT RESET. OCCURRED DURING APU START CYCLE. NR 1 GCU POSTED IDG FAULT LIGHT IAW FIM 24-21/805 STEP F.(1), R & R NR 1 ENGINE IDG IAW AMM 24-11-11-500-801, 24-11-11-400-801 AND 24SDR ASAA2013032694272Drive Unit · failedWEATHER RADAR FAIL FLAG ON ND. FAULT CODE 344-050-32. VERIFIED FAULT RT INOPERATIVE. REPLACED WEATHER RADAR TRANSCEIVER IAW MM 34-43-41. PERFORMED WEATHER RADAR GROUND CHECK, FAULTED ANTENNA IAW MM 34-43-00. REPLACED WEATHER RADAR ANTENNA DRIVE UNIT IAW AMMSDR ASAA2013032694271None · noneNO SAT PROMPT ON MCDU. PERFORMED SATCOM TESTS REF M/M TASK 23-15-00-730-801. NO DEFECTS NOTED.SDR ASAA2013032694269Warning Light · false activationAIR CONDITION ZONE TEMP LIGHT ILLUMINATED, QRH FOLLOWED. NR 2 TEMP CONTROLLER LOGGED FLT DECK TRIM AIR FAULT. NO HISTORY LAST 30 DAYS. PERFORMED FIM 21-62, TASK 832 TRIM AIR FAULT RESET & PERFORMED FIM 21-62, TASK 801 & TEMP CONTROL BITE CHECK PASSED. GROUSDR ASAA2013032594268Eec · malfunctionedWHILE RUNNING NR 1 ENGINE, FOUND MAINT MESSAGE DEU 2 BLEED DATA DISAGREE. NR 1 EEC BITE IAW MM 73-21-00-740-801-F00 SHOWED ONE OCCURRENCE OF SHORT TERM FAULT 73-11291 DEU-2 BLEED DATA DISAGREE. ACCOMPLISHED TROUBLESHOOTING FOR FAULT 73-11291 IAW FIM 73-24,SDR ASAA2013032594265Warning Light · illuminatedFMC DISAGREE DISPLAYED ON PUSHBACK. PERFORMED QRH, OPS NORMAL.SDR ASAA2013032594264Battery Pack · no testEMERGENCY BATTERY PACK M1673 FAILED TEST. REPLACED AND OPS CHECKED GOOD, IAW MM 33-51-06-960-806.SDR ASAA2013032594263Controller · malfunctionedCONT CAB LIGHT ON RECALL RESETS ON MC RECALL. CONFIRMED FAULT, CONT CABIN ZONE TEMP LIGHT ILLUMINATES ON MASTER RECALL. T/S FOUND NR 2 ZONE TEMP CONTROLLER WITH FLT DECK TRIM VALVE FAULT LIGHT ILLUMINATED AFTER INTERROGATION. PERFORMED NR 1 & NR 2 CABIN TESDR ASAA2013032594260Warning Light · false activationON LANDING, LT PACK LIGHT ILLUMINATED. QRH PROCEDURE PERFORMED, LIGHT STAYED ON. EXTINGUISHED ON SHUTDOWN. ACCOMPLISHED PACK & ZONE TEMP CONTROLLER TEST IAW MM 21-61-00. NO FAULTS FOUND. NO LIGHT ON RECALL. NO HISTORY LAST 30 DAYS.SDR ASAA2013032594259Control Panel · malfunctionedAUTO PRESSURE CONTROLLER PANEL, LAND ALTITUDE WINDOW INOPERATIVE, BLINKED FOR SEVERAL MINUTES BEFORE GOING BLANK. LAND ALTITUDE WINDOW INDICATES ALTITUDE SET BY CONTROL PANEL. ON LIGHTS TEST ALL SEGMENTS ARE LIT, NO HISTORY, NO FAULTS FOUND ON THE CONTROLLSDR ASAA2013032594258Warning Light · false activationCONT CABIN ZONE TEMP LIGHT ILLUMINATES ON RECALL, RESETS. VERIFIED ZONE LIGHT WITH RECALL. PERFORMED M/M TASK 21-61-00-700-806-002. INITIAL FIND WAS FAULT LOGGED FOR NR 2 TEMP CONTROLLER FLT DECK TRIM VALVE. TEMP CONTROLLER BITE TEST VERIFY TEST PASSED WITHSDR ASAA2013032594242Power Supply · failedEMERGENCY BATTERY PACK, M1673 FAILED TEST. REPLACED AND OPS CHECKED GOOD, EMERGENCY POWER SUPPLY IAW MM 33-51-06-960-806.SDR ASAA2013032494257Relay · failedDURING CRUISE, FL350, WITH 10,000 LBS FUEL REMAINING IN CENTER TANK, LT CENTER TANK LOW PRESSURE LIGHT ILLUMINATED. ACCOMPLISHED FUEL PUMP LOW PRESSURE QRH PROCEDURE, TURNED OFF PUMP AND OPENED CROSSFEED. REMAINDER OF CENTER TANK FUEL BURNED NORMALLY VIA RT SDR ASAA2013032494244Engine · vibrationON TAKE OFF AND CLIMB, F/A AND PAX REPORTED LOUD VIBRATION FROM LT ENGINE AND ODOR OF OIL & SMOKE IN CABIN. SOUND REDUCED WITH POWER 70 N1. ALL ENGINE INDICATIONS NORMAL VIBRATION INCREASED DURING DESCENT WITH POWER AT IDLE. ALL C/P INDICATIONS NORMAL. NOSDR ASAA2013032494251Fmc · false indicationFMC DISAGREE MESSAGE ANNUNCIATED ON TAXI OUT. CHECKLIST PROCEDURE EXECUTED. FMC OPERATION RETURNED TO NORMAL. NO HISTORY 90 DAYS. PERFORMED FMC SYS OPS CK IAW MM 34-61-00-710-801. PASSED.SDR ASAA2013032494250Smoke Detector · failedCARGO FWD ARM DOESN`T ILLUMINATE RED ON TEST. R & R FWD CARGO TWO AFT DETECTORS AND CARGO SMOKE DETECTION. TEST OPS CHECKED GOOD REF MM TASK 26-16-00-710-80.SDR ASAA2013032394241Fmc · false indicationFMC DISAGREE ON FLAP SELECTION AFTER ENGINE START. QRH ACCOMPLISHED WITH SUCCESSFUL OUTCOME.SDR ASAA2013032394240Solenoid Valve · failedENGINE AND WING CIRCUIT BREAKER P18-3 A6 TRIPPED. R & R NR 2 ENGINE GROUND THERMAL ANTI-ICE SOLENOID VALVE IAW AMM 30-11-12, OPS CHECK GOOD IAW AMM 30-11-12. R & R ENGINE AND WING THERMAL ANTI-ICE PANEL IAW AMM 30-11-41, OPS CHECK GOOD IAW AMM 30-11-41. C/W SDR ASAA2013032394239Control Valve · malfunctionedON RECALL CONT CABIN ZONE TEMP LIGHT ILLUMINATED. EXTINGUISHES ON RECALL. ACFT GROUNDED. R & R CONTROL CABIN TRIM VALVE REF MM 21-61-21-400-801.SDR ASAA2013032394238Control Module · inoperativeON THE PRESSURIZATION CONTROL PANEL,THE FLIGHT ALTITUDE DISPLAY IS INOPERATIVE, ONLY RANDOM LINE SEGMENTS ARE ILLUMINATED. R & R CABIN PRESSURE CONTROL MODULE REF 21-31-02-400-801, OPS CK OK, GROUND VERIFICATION CK OK.SDR ASAA2013032294249Satcom · malfunctionedSATCOM, THERE IS NO SAT PROMPT AVAILABLE AT 4L ON THE MCDU. ACCOMPLISHED SATCOM COMMUNICATION SYS TEST IAW AMM TASK 23-15-00-730-801. VERIFIED OUTGOING CALL AND INCOMING CALL VOICE TEST GOOD WITH DISPATCH-A IN DIRECTORY.SDR ASAA2013032294248Oven · odorF/A REPORT THAT THEY DETECTED AN ODOR, POSSIBLY ELECTRICAL COMING FROM THE MIDDLE OVEN IN THE AFT GALLEY. TURNED OVEN OFF AND ODOR STOPPED. TURNED OVEN ON BUT IT WOULD NOT COME ON. SEVERAL MINUTES LATER OVEN CAME ON. ODOR RETURNED. TURNED OVEN OFF, AND OSDR ASAA2013032294234Battery Pack · failedAFT GALLEY LT EMERGENCY LIGHTS FAILED TIME CHECK. R & R BATTERY PACK M1673 IAW AMM TASK 33-51-06-960-805 AND WDM 33-51-14. BATTERY PACK TEST PASSED.SDR ASAA2013032294231Indication Sys · malfunctionedWHILE LOADING THE LOAD CLOSEOUT DATA, NOTICED FUEL TOTAL SHOWS 22.5 NOW, BUT SENT IN 23.3. APU NOT RUNNING. REF AMM 28-41-00-720-801, PERFORMED COMPARISON CHECK AT THE FQIS WITH MEASURING STICKS FOUND TO BE WITHIN LIMITS, NO HISTORY PAST 60 DAYS.SDR ASAA2013032194235Floorbeam · damagedAFT CARGO COMP CARGO FLOORBEAM HOLED ON UPPER FLANGE STA NR 765 & RBL 8.10. REPAIRED CARGO FLOORBEAM IAW SRM 53-00-53, REPAIR 4.SDR ASAA2013032194233Window · failedL2 WINDOW SHATTERED OUTER PANEL. REPLACED L2 WINDOW REF AMM 56-12-11-400-801. ACCOMPLISHED CABIN PRESSURE LEAK TEST REF AMM 05-51-91-790-801, LEAK TEST GOOD. WINDOW HEAT SYS OPS TEST GOOD REF. AMM 30-41-00-710-801.SDR ASAA2013032194232Sensor · malfunctionedLEFT CAPTAINS WINDOW OVERHEAT LIGHT ILLUMINATED. QRH PROCEDURE FOLLOWED MX AND DISPATCH NOTIFIED VIA ACARS AT 0117Z. PERFORMED BITE CK OF WHCU IAW FIM TASK 30-41 TASK 801 NO CURRENT FAULTS. FAULT HISTORY SHOWS LT SIDE WINDOW SENSOR FAULT. SWAPPED LT SIDE SDR ASAA2013032094228Transmitter · malfunctionedAFTER FLT 854, PILOTS VERBALIZED NR 2 ENG F/F UP TO 300LBS/HR HIGHER THAN NR 1 ENG & FUEL USED SHOWED 1000LBS HIGHER THAN SCHEDULED BURN AFTER 4 1/2 HR FLT DURATION. ALSO, FUEL USED 28K, 10K FUEL REMAINING END-OF-FLT = 38K BUT DEPARTURE FUEL WAS 37K. OTHER SDR ASAA2013032094218Fmc · failedLEFT FMC FAILED. R & R LT FMC IAW AMM 34-61-02. FMC GROUND VERIFICATION SATISFACTORY.SDR ASAA2013032094217Pin · failedCREW REPORT EMERGENCY LIGHT LENS COVER AT L1 DOOR FELL OFF. FOUND PIN BAD ON LENS COVER REPLACED WITH SERVICABLE LENS COVER.SDR ASAA2013031994207Panel · wornNR 2 ENGINE INLET AND FAN BLADES DETAILED INSPECTION. FOUND FAN DUCT PANEL NR 5 AT APPROX 430 O`CLOCK POS (ALF) HAS DAMAGED FASTENER HEADS FROM BEING LOOSE. REPLACED NR 5 FAN DUCT PANEL FASTENERS REF MM 72-23-07.SDR ASAA2013031994205A/C Pack · malfunctionedLEFT PACK BLEED TRIP AT FL 400, RESET ONCE, BLEED TRIP HAPPENED AGAIN, RESET A SECOND TIME, LIGHT STAYED OUT. PERFORMED BLEED TRIP OFF LIGHT ON, FAULT ISOLATION IAW FIM TASK 36-10 TASK 801. PREFORMED PRELIMINARY CHECKS, FAULT ISOLATION PROCEDURES AND REPAISDR ASAA2013031994202Valve · failedENGINE ANTI ICE NR 1 COWL VALVE OPEN LIGHT REMAIN BRIGHT BLUE. WHEN SELECTED TO ON. SELECTION AT FL260, BRIGHT BLUE, DURING DESCENT WENT DIM AT FL180. AT 10000 FT WENT BRIGHT AGAIN WHILE IN CLOUDS. REMAINED BRIGHT BLUE UNTIL LANDING. REPLACED NR 1 ENG TAI VASDR ASAA2013031994201Compensator · malfunctionedCRUISE LEVEL FLIGHT, LT MAIN TANK 7.96, R MAIN TANK 8.54. BEGAN CROSSFEED, AFTER 5 MINUTES FUEL QTY INCREASED IN LT MAIN TANK TO 8.27, RT MAIN TANK 8.44. FQUIS BITE TEST GROUND TEST FAILED. TANK 1 COMPENSATOR DATA BAD. INFLIGHT FAULTS LOGGED FAULT CODE 28-4SDR ASAA2013031994200Idg · failedDURING CRUISE AT FL 340, NR 1 IDG DRIVE LIGHT ILLUMINATED AND VOLTS AND FREQ INDICATED 0. IDG DISCONNECTED VIA CHECKLIST. REPLACED NR 1 ENG IDG IAW NG-800 ASA MM 24-11-400-801 AND 24-11-00-700-802. INSTALLATION TEST AND LEAK CHECK. IS GOOD.SDR ASAA2013031994199Warning Light · false activationLEFT PACK LIGHT ILLUMINATES DURING RECALL, EXTINGUISHES WHEN MASTER CAUTION PUSHED. PERFORMED BITE TEST OF THE LT PACK/ZONE TEMP CONTROLLER IAW AMM 21-61-00-700-806-002, RAM ACTUATOR FLAGGED ON BIT CHECK. PERFORMED VERIFY AND RECEIVED GREEN GO LIGHT. RESET SDR ASAA2013031994198Warning Light · false activationRT PACK LIGHT ILLUMINATED. IT WILL NOT EXTINGUISH WHEN MASTER CAUTION IS RESET. ACCOMPLISHED FIM TASK 21-61, NR 801, NR 2 PACK ZONE TEMP CONTROL SHOWS TCV FAULT RESET AND CHECKED OK. NR 1 PACK ZONE TEMP CONTROLLER SHOWS STAND BY PACK CONTROLLER FAULT RESET SDR ASAA2013031994197Warning Light · false activationRIGHT PACK LIGHT COMES ON DURING RECALL, EXTINGUISHES WHEN MASTER CAUTION REST. PERFORMED BITE TEST OF RT PACK/ZONE TEMP CONTROLLER REF MM 21-51-00-700-803. NO FAULTS NOTED AFTER SEVERAL TESTS. GROUND VERIFICATION SUCCESSFUL.SDR ASAA2013031894195Starter · failedNR 2 ENGINE STARTER FAILED WHILE LEAK CHECKING CHIP DETECTORS. REPLACED NR 2 ENG STARTER REF MM 80-11-01, STARTER TEST IAW 71-00-00.SDR ASAA2013031894194Warning Light · malfunctionedDURING STANDBY POWER CHECKS, SPAR VALVE. ENGINE VALVE TEST WITH P6-3 C-6 PULLED START LEVERS 12 TO IDLE SPAR VALVE CLOSED LIGHTS DID NOT EXTINGUISH (STAYED BRIGHT). WHEN ENG FIRE CHARGED EMERGENCY FUEL SHUTOFF BATTERY FOR 1 HR IAW AMM 28-22-14-400-801. FUEL SSDR ASAA2013031794211Valve · malfunctionedCONT CAB ZONE TEMP LIGHT ILLUMINATES ON RECALL, RESETS WITH MASTER CAUTION. ACFT GROUNDED. ZONE TEMP CONTROLLER NR 2 BITE FAULTS FLT DECK TRIM VALVE ON BITE AND PREVIOUS FLIGHT. REPLACED FLIGHT DECK TRIM VALVE (V143). BITE CHECK PASSES AND LEAK CK OK. REF SDR ASAA2013031794209Control Valve · malfunctionedRT PACK LIGHT ILLUMINATES ON RECALL DOES NOT RESET LIGHT GOES OUT WITH MASTER CAUTION RESET. ACFT GROUNDED. UNABLE TO DUP/VERIFY DISCREP. UPON ARRIVAL, RT PACK LIGHT WILL NOT ILLUMINATE ON RECALL. AS REQUESTED, INTERROGATED BOTH TEMP CONTROLLERS - BIT, PREVSDR ASAA2013031794191Filter · cloggedAPU OIL FILTER DELTA P INDICATOR EXTENDED. APU OIL FILTER INDICATOR SERVICE COMPLETED IAW AMM 49-91-13. LEAK CHECKED GOOD, PIN RESET.SDR ASAA2013031794190Warning Light · false activationON F/OS CDU GOT SINGLE FMC WARNING & MAP LIGHT ON NAV DISPLAY. PUT BOTH FMC ON 1 AND RETURNED TO NORMAL - OPS NOW NORMAL. REF 34-61-00 AND FIM TASK 801 FIM 34-61, NO FAULTS.
Back to Boeing 737-890