SDR ASAA2013031694164Epsu · inoperativeBATTERY PACK M1694 WOULD NOT POWER THE FLOOR PROXIMITY LIGHTS AT THE RT & LT FWD OVER WING EMERGENCY EXIT DOORS REPLACED BATTERY PACK & OPS CHECKED GOOD.SDR ASAA2013031594176Control Unit · faultedLIGHT ON OVERHEAD PANEL OBSERVED ON PREFLIGHT. SPCU FAULT LOGGED WILL NOT RESET. REPLACED SPCU IAW AMM 24-34-11, OPS CKD NORMAL. ALL GROUND FUNCTIONAL TESTS GOOD.SDR ASAA2013031594174Actuator · inoperativeON W/A FOUND LT RAM AIR DEFLECTOR DOOR NOT DEFLECTING. ACFT GROUNDED. RAN BITE CK OF ZONE TEMP CONTROLLER & FAULTED RAM AIR ACTUATOR & ACTUATOR WOULD NOT RETRACT TO PUSH DOOR OUT. R & R LT RAM AIR DOOR ACTUATOR, REF MM 21-51-21 ADJUSTMENT AND TEST GOOD.SDR ASAA2013031494213Floor Support · gougedFWD CARGO BILGE RT SIDE BS 460, FLOOR SUPPORT GOUGED. REMOVED DAMAGE AND REPAIRED FLOOR SUPPORT IAW SRM 53-00-53. REPAIR NR 2 ALODINED AND PRIMED IAW SRM 51-20-01.SDR ASAA2013031494180Transmitter · leakingNR 2 ENGINE OIL QUANTITY READS ZERO. R & R NR 2 ENGINE OIL QTY TRANSMITTER REF AMM 79-31-01. LEAK CHECKED TRANSMITTER REF AMM 71-00-00 TEST 3A, NO LEAKS NOTED. PERFORMED FUNCTIONAL TEST OF OIL QTY INDICATION REF AMM 79-31-01. INDICATION CHECK NORMAL.SDR ASAA2013031494178Filter · cloggedDURING OTHER MAINT FOUND APU OIL FILTER INDICATOR EXTENDED. ACCOMP OIL FILTER INDICATOR SERVICING. INSP MAGNETIC DRAIN PLUG & REPLACED LUBE FILTER ELEMENT. NO CONTAMINATION FOUND. REF AMM 49-91-13. NO LEAKS NOTED, OPS CK GOOD. DELTA-P DID NOT EXTEND.SDR ASAA2013031494177Warning Light · false activationDURING APU START AT GATE, FAULT LIGHT ILLUMINATED. TURNED APU SWITCH OFF AND LIGHT WENT OUT. SECOND START WAS NORMAL. COMPLISHED APU BITE IAW FIM 49-60, TASK 801. CURRENT STATUS SHOWS NO FAULTS. FAULT HISTORY FOR PREVIOUS START SHOWS MX MESSAGE 49-41012, SDR ASAA2013031494175Control Valve · faultedLT PACK LIGHT ILLUM AFTER START DURING SYS RECALL. ACFT GROUNDED. REPLACED LT PACK TEMP CONTROL VALVE REF MM 21-51-10. OP CHECK GOOD. BITE CHECKED LT PACK TO VERIFY FAULT CLEARED REF MM 21-61-00 BITE CHECK GOOD. RESET PACK CONTROLLER, OK FOR SERVICE.SDR ASAA2013031494173Control Valve · faultedON RECALL, MASTER WARNING, A/C - ANNUNCIATOR AND LT LIGHT CAME ON. ALL EXTINGUISHED UPON RESET. PERFORMED BITE TEST OF LT PACK ZONE TEMP CONTROLLER REF AMM 21-61-00-700-806-002. VERIFIED FAULT, FOUND FAULTED LT PACK TCV. REPLACED LT PACK TEMP CONTROL VALVSDR ASAA2013031494172Unknown · odorVERY STRONG UNPLEASENT ODOR ON DESCENT PASSING THRU 11000 FT UNTIL 3000 FT. F/A REPORT A CHEMICAL ODOR IN THE BACK. CABIN ODOR TROUBLESHOOTING ACCOMPLISHED AND APU REPLACED. AIR CONDITIONING SYS REPAIRED.SDR ASAA2013031394163Warning Light · false activationSTART VALVE OPEN LIGHT ILLUMINATED ON NR 2 ENGINE. CHECKLIST FOLLOWED TO NORMAL SHUTDOWN. STARTED NR 2 ENGINE WITH ALL NORMAL INDICATION. NO FURTHER ACTION. NO HISTORY 30 DAYS. ACFT RELEASED FOR SERVICE.SDR ASAA2013031394162Filter · cloggedAPU OIL FILTER INDICATOR EXTENDED. R & R OIL FILTER ELEMENT, SERVICED APU, REF AMM 49-91-13-600-801. LEAK CK GOOD.SDR ASAA2013031394161Unknown · unknownAUTO FAIL LIGHT ILLUMINATED ON CABIN ALTITUDE CONTROL PANEL WITH ALTERNATE (GREEN) LIGHT ALSO ILLUMINATED, NO NOTICABLE PRESSURE CHANGES. FOLLOWED QRH AND SELECTED ALTERNATE POSITION ON CONTROL PANEL, PRESSURE OPERATES NORMALLY, NOTE: SLIGHT DUCT SPLIT. LT DSDR ASAA2013031394160Fmc · failedBOTH FMCS FAILED AFTER TAKEOFF. VTK DISPLAYED ON BOTH SIDES. RESTORED AFTER ABOUT 30 SECONDS. ALSO THE INITIAL POINT ON THE LEGS PAGE WAS REPLACED BY A DICO ON LIFTOFF. MAY HAVE BEEN THE FMCS STARTING TO FAIL. FMCS BITE SHOWS NR 1 AND 2 FMC FAIL REMOVED ANSDR ASAA2013031394159Warning Light · false activationLEFT CENTER TANK FUEL BOOST PUMP LOW PRESSURE LIGHT ILLUMINATED IN FLIGHT IN CRUISE AT 33,000 FT. MASTER CAUTION ALSO ILLUMINATED. 16, 800 LBS IN CENTER TANK. PERFORMED CENTER TANK BOOST PUMP AUTO SHUTOFF FUNCTIONAL TEST IAW MM 28-22-00, OPS CHECKED GOOD. SDR ASAA2013031394158Warning Light · false activationLEFT PACK LIGHT ON RECALL ON (UNREADABLE) EXTINGUISHES WITH MASTER CAUTION RESET. ACCOMPLISHED PACK/ZONE TEMPERATURE CONTROL BITE TEST, CLEARED FAULTS, OPS NORMAL REF MM 21-61-00-700-806-002. NO HISTORY LAST 60 DAYS.SDR ASAA2013031294224Skin · dentedLT HORIZONTAL STAB L/E HAS DENT AT L/E STA 206. REPAIRED DENT AT L/E STA 206 IAW SRM 55-10-01, REPAIR 1 AND REPAIRED RIB IAW ASA EA 800-55EA-10011, REV NEW DATED 22 MAR13 AND REO G16077, REV A DATED 3/21/13.SDR ASAA2013031294222Skin · dentedDENT OBSERVED ON STABILIZER WING ROOT AT L/E STA.76, 80 AND 241. ACFT RT ON WALK-AROUND. REPAIRED IAW SRM 55-10-01. REPAIR 1. THIS IS A PERMANENT REPAIR.SDR ASAA2013031294219Skin · dentedLEFT HORIZONTAL STABILIZER L/E HAS DENT AT L/E STATION 177. REPAIRED IAW SRM 55-10-01. REPAIR 1.SDR ASAA2013031294151Fmc · false indicationFMC DISAGREE, QRH PERFORMED. OPS NORMAL.SDR ASAA2013031294150Control Panel · inoperativeCPTS COURSE SELECTOR KNOB INOPERATIVE. FFR SHOW NO FAULT. UNABLE TO DUPLICATE DUE TO HISTORY R & R MCP. INSTALLATION TEST GOOD REF MM 22-11-34. BITE TEST GROUP 49 32 AND 58 GOOD. REF MM 22-11-00.SDR ASAA2013031194146Autopilot Sys · malfunctionedCAPTAIN SIDE MCP COURSE SELECTOR KNOB TURNS, BUT WILL NOT ALLOW NEW COURSE SELECTION. UNABLE TO DUPLICATE, RAN COURSE SELECTOR 360 DEGREES BOTH CW AND CCW SEVERAL TIMES. NO HISTORY LAST 30 DAYS. PERFORMED INSTALLATION TEST REF MM 22-11-34-740-801, DFGS BITESDR ASAA2013031194145Unknown · unknownOVERHEAD AIR TEMP, SUPPLY DUCT, PACK INDICATOR GAUGE READS ZERO IN ALL POSITIONS. COMPLETE CONTROL OF PASSENGER CABIN TEMP, SUPPLY DUCT, AND PACK TEMP. NO OTHER ABNORMAL INDICATIONS. PERFORMED OPS CHECK IAW AMM 21-61-32-400-801. OPS CHECKED NORMAL, NO HISTORSDR ASAA2013031094152Battery · inoperativeON PDC WALKAROUND, FOUND MAIN AND AUX BATTERIES INOP. ACFT GROUNDED. R & R ACFT MAIN AND AUX BATTERIES IAW AMM 24-31-11-400-802-002. ACCOMPLISHED INSTALLATION TEST, OPS CK GOOD.SDR ASAA2013031094130Coupler · failedHF1 AND HF2 VOICE TRANSMIT REPORTED WEAK MID-PACIFIC. RESUMED WORKING FURTHER WEST. HF2 DATA WORKED OK. ACFT GROUNDED. REF AMM 23-11-61-400-801, REMOVED HF COUPLER FOR THE NR 2 POSITION. GROUND VERIFICATION CHECK SUCCESSFUL. ACFT OK FOR SERVICE.SDR ASAA2013031094129Warning Light · false activationWHEN LEVEL CHANGE SELECTED AIRBORNE OR LIGHTS TEST SELECTED AIRBORNE AMBER ACTUATION LIGHT WITHIN THE BUTTON DOES NOT ILLUMINATE. COULD NOT DUPLICATE, ALL MODE CONT PANEL LIGHTS ILLUMINATE WITH LIGHTS TEST AND OPS CKS NORMAL IAW DFCS LIBRARY TEST NR 50.SDR ASAA2013031094128Connector · unsecureLEFT AIR CONDITIONING ACCESSORY UNIT FAILS INSTALLATION TEST FOR NG-23EO-07569-2, STEP 25G. LT PACK LIGHT DOES NOT ILLUMINATE WHEN PINS 1 & 2 OF D532 ARE JUMPED. RESEATED D646 IAW SWPM 20-60-06 CHECKED GOOD IAW AMM 21-51-02.SDR ASAA2013030994109Fuel Cell · contaminatedLT AND RT FUEL TANK GAUGES FLUCTUATE /- 700 POUNDS DURING FUELING, CLIMB AND CRUISE. ACFT GROUNDED. FQIS BITE IAW FIM 28-41, TASK 801 SHOWS FAULT CODES 28-41108 COMPENSATOR DATA BAD AND 28-41208 COMPENSATOR DATA BAD FOR NR 1 AND NR 2 TANKS RESPECTIVELY AND DSDR ASAA2013030894135Transceiver · inoperativeRADIO UNABLE TO TRANSMIT, RECEIVES OK. ACFT GROUNDED. REPLACED NR 1HF TRASCEIVER IAW AMM REF 23-11-21-400-801/23-11-21-000-801. OPS CKS GOOD. PERFORMED HF OPS CK IAW AMM REF 23-11-00-710-801. ALL COMMUNICATION LOUD AND CLEAR.SDR ASAA2013030894113Indicator · activatedAPU OIL FILTER DELTA P INDICATOR HAS EXTENDED. R & R APU OIL FILTER REF MM-49-91-13. RESET DELTA P INDICATOR AND LEAK CHECK GOOD. PERFORMED TASK MM 49-91-13-600-801. INSPECTED MAGNETIC DRAIN PLUG, NO METAL FOUND.SDR ASAA2013030894111Sign · unsecureMID CABIN EXIT SIGN FELL OFF DURING CLIMB OUT. RESECURED MID CABIN EXIT SIGN. OK FOR SERVICE.SDR ASAA2013030894110Light · intermittentDURING PDC FOUND LT WINDOW LIGHT NOT ILLUMINATED. CYCLED POWER FOR LT FWD WINDOW LIGHT ILLUMINATED IAW AMM 30-41-00-710-801. PERFORMED BITE CHECK OF WINDOW HEAT CONTROLLER NO FAULTS FOUND. INSPECTED CIRCUIT BREAKER, NO FAULTS FOUND. GROUND VERIFICATION CHSDR ASAA2013030894108Compensator · failedDURING CRUISE FLIGHT RT MAIN TANK FUEL QTY INDICATION BLANKED FOR APPROX 30 SECONDS, RETURNED TO NORMAL. REPLACED RT MAIN TANK COMPENSATOR UNIT REF AMM 28-41-21. OPS AND LEAK CHECKED GOOD.SDR ASAA2013030794112Keypad · defectiveCAPTAINS CDU KEYPAD LEGS BUTTON HAS NO TACTILE FEEDBACK. VERIFIED DEFECT, R & R CAPTS MCDU KEYPAD IAW MM 34-61-01,GROUND VERIFICATION TEST PASSED.SDR ASAA2013030794107A/C Pack · malfunctionedON CLIMB OUT, RT PACK TRIPPED, RESET PACK IAW QRH. RT PACK TRIPPED A SECOND TIME AND REMAINED OFF FOR THE REMAINDER OF FLIGHT IAW QRH. UNABLE TO DUPLICATE.SDR ASAA2013030694114Fuel Cell · contaminatedON DESCENT AT 6000 FT, THE IMBALANCE LIGHT ILLUMINATED. FUEL STATE WAS 7.62 LT MAIN, 5.56 CTR, 8.62 RT MAIN. CROSSFEED TO BALANCE WORKED. NO LOW PRESSURE BOOST PUMP LIGHTS ILLUMINATED. REMOVED ICE AND RESIDUAL WATER FROM NR 2 FUEL TANK. R & R NR 2 F/Q SDR ASAA2013030694089Lens · missingEMERGENCY LIGHT LENS MISSING IN FRONT OF AFT LT LAVATORY. INSTALLED LENS.SDR ASAA2013030694088Solenoid · failedNR 1 ENGINE COWL ANTI-ICE WOULD NOT COME ON AFTER ENGINE START. FOUND ENGINE NR 1 ENGINE AND WING CONTROL CIRCUIT BREAKER OPEN. ACFT GROUNDED. D648 PINS 26 AND 26 READ 63 OHM TO GROUND. 27681. REINSTALLED ENG WING ANTI ICE PANEL IAW AMM 30-11-41. GROUND VESDR ASAA2013030694086Circuit Breaker · failedON TAXI IN, AFTER SHUTTING DOWN NR 2 ENGINE, NO POWER TRANSFER. TRANSFER BUS OFF AND SOURCE OFF LIGHT ILLUMINATED. ACFT WOULD NOT ACCEPT GROUND POWER. APU STARTED AND POWER APPLIED NORMALLY. ACFT GROUNDED. RAN BOTH ENGINES AND TOGGLED NR 2 ENGINE GENERATOSDR ASAA2013030594214Floor Panel · damagedAFT CARGO FWD OF DOOR FLOOR PANEL REPAIR DOUBLER MISSING RIVET AND CORNER DAMAGED. ACCOMPLISHED E.A 800-25EA-9885.SDR ASAA2013030594077Warning Message · false activationON PUSHBACK, HAD FMC DISAGREE, RAN CHECKLIST IN QRH AND AFTER RESETTING CIRCUIT BREAKERS FMC WORKED NORMALLY.SDR ASAA2013030494085Compensator · failedFUELED ACFT TO 23.1 LBS UPON GETTING NRS FUEL DROPPED TO 22.6. UNABLE TO EXPLAIN LOSS OF 500 LBS. APU RUNNING FOR APPROX 10 MIN. ACFT GROUNDED. LAST 25 LEGS LOGGED TANK 1 DEGRADED. COMPENSATOR DATA BAD. CODE 28-41108. REMOVED COMPENSATOR REF MM TASK 28-41-SDR ASAA2013030494080Pressure Switch · failedAFTER LANDING NR 1 FUEL FILTER BYPASS LIGHT ILLUMINATED ON TAXI IN. PERFORMED FIM TASK 73-05, TASK 801 AND TASK 802 FOR NR 1 ENG. CDU FAULT MESSAGE 73-31071 NOTED. R & R NR 1 ENG FUEL FILTER IAW AMM 73-11-02 AND R & R NR 1 FUEL FILTER DIFFERENTIAL PRESSURESDR ASAA2013030494079Panel · crackedWHILE ACCOMPLIMENT OF TC 78472000, NR 2 ENG INLET & FAN INSPECTION FOUND BLEED VALVE LOWER PANEL 530-600 POSN AFT LOOKING FWD CRACKED. REPLACED PANEL IAW AMM 72-23-07-400-801-F00.SDR ASAA2013030494078Converter · failedAPU WONT START, VERIFIED DISCREPANCY - PERFORMED APU BITE IAW 49-60 TASK 801. FOUND FAULT CODE 49-41254 ACTIVE. START CONVERTER UNIT SHOWS START SYS INOP. PERFORMED 49-40, TASK 821. REMOVED START CONVERTER UNT. INSTALLED NEW SCU IAW 49-41-61. PERFOMED OPSDR ASAA2013030494069Solenoid · failedNR 1 ENGINE GROUND WING TAI SOLENOID VALVE FAILED OPS TEST. REPLACED GROUND WING TAI ON NR1 ENGINE IAW MM 30-11-12 LEAK & OPS CHECKED GOOD.SDR ASAA2013030494068Compensator · failedRAMPERS PULLED GROUND POWER WHICH CAUSED A POWER INTERRUPTION. BEFORE THE INTERRUPTION FUEL IN NR 1 TANK= 8.6, CTR= 27.0, NR 2=8.6. 44.2 TOTAL. AFTER THE INTERRUPTION FUEL IN NR 1 TANK=8.1, CTR=27.0, NR 2=8.5. 43.6 TOTAL. AFTER MORE FUEL ENTERED NR 1 TANK = SDR ASAA2013030394082Unknown · unknownSATCOMM PROMPT IS NOT AVAILABLE IN THE MCDU. ACFT GROUNDED. UNABLE TO DUPLICATE DEFECT, ALL LIGHTS WERE GREEN. R & R SATCOM TRANSCEIVER, REF MM 23-15-00, OPS CHECK NORMAL.SDR ASAA2013030394057Unknown · unknownAFTER ENGINE START, LT DUCT PRESSURE WAS INDIATING 0, FOUND LT BLEED VALVE CIRCUIT BREAKER HAD TRIPPED. INSPECTED C/B P6-4 A7 NO DEFECTS NOTED, RESET CIRCUIT BREAKER IAW AMM 20-60-01, CIRCUIT BREAKER REMAINS SET INSPECTED BLEED AIR REGULATOR, NO DEFECT NOTEDSDR ASAA2013030394056Warning Light · false activationAFTER ENGINE START, FMC DISAGREE MESSAGE APPEARED. ACCOMPLISHED QRH ITEMS - MESSAGE CLEARED.
Back to Boeing 737-890