SDR ASAA2012081592726Radar · malfunctionedPWS FAIL. ACFT GROUNDED. ACCOMPLISHED FIM 34-43-00-810-815. WEATHER RADAR SYS OPS TEST, OPS NORMAL AND BLOWER OPERATES WITH NO OBSTRUCTIONS. DUE TO HISTORY REPLACED NEXT LIKELY LRU IAW FIM TASK REPLACED ANTENNA DRIVE UNIT REF MM34-43-00. OPS NORMAL.SDR ASAA2012081592725Warning Light · false activationWHILE ON TAXI OUT, PDX FMC DISAGREE MASTER CAUTION ANNUNCIATED. ACFT GROUNDED. RAN QRH FOR ON GROUND ISSUE AND ISSUE WAS RESOLVED.SDR ASAA2012081592724Circuit Breaker · malfunctionedAUTOTHROTTLE INOPERATIVE. ACFT GROUNDED. CYCLED AUTOTHROTTLE CIRCUIT BREAKER. AUTOTHROTTLES OP CHECKED NORMAL. THROTTLE TESTS, REPLACE TEST IAW BITE GROUP NR 35, & HGS SMM 34-36-00.SDR ASAA2012081392714Unknown · leakingFOUND OIL LEAKING FROM MIDDLE DRAIN OF APU IAW 05-60-00-280-801CSTEP A.(2) (C) APU REQS REPLACEMENT. BLACK LIGHT TEST OF SWABS FROM LOAD COMPRESSOR DRAIN DID NOT PROVIDE CONCLUSIVE EVIDENCE OF OIL CONTAMINATION. RAN APU WITH RT PACK ON FOR 30 MINUTES. NO ASDR ASAA2012081492723Start Valve · malfunctionedAFTER START OF NR 1 ENGINE, START VALVE FAILED TO CLOSE FOR LONGER THAN NORMAL. BEFORE FINISHING CHECKLIST, VALVE CLOSED ON ITS OWN. ACFT GROUNDED. FOUND NR 1 ENGINE START VALVE RATCHETING AND WILL NOT SPRING BACK CLOSED SMOOTHLY. R & R NR 1 ENGINE START VALSDR ASAA2012081492722Transceiver · failedPWS FAIL ANNUNCIATED INTERMITTENTLY ON APPROACH AND AFTER LANDING. ACFT GROUNDED. CONFIRMED. WEATHER RADAR TESTED ON GROUND SHOWS PWS FAIL, WEATHER RADAR FAIL, & RT. PULLED & RESET TRANCEIVER CIRCUIT BREAKER - NO HELP. REPLACED WEATHER RADAR TRANCEIVER. OPSDR ASAA2012081492721Module · failedON CLIMB-OUT, LOST ALL PROBE HEAT (A) (ALL CBS IN). GEN 2 - 56 AMPS GEN 1-66 TO 95 AMPS. ACFT GROUNDED. VERIFIED DISCREPANCY WITH PROBE HEAT SWITCH ON (A) VERIFIED LIGHTS REMAIN ON WITH TEMP GUN, VERIFIED PROBES HOT WITH SWITCH ON. R & R P5-9, REF 30-41-41 SDR ASAA2012081492720Light · intermittentAUTOTHROTTLE ARM LIGHT INOPERATIVE. ACFT GROUNDED. ACCOMPLISHED A/T SYS OPS TEST IAW AMM TASK 22-31-00-710-801, A/T SYSTEM TEST NORMAL. VERIFIED A/T ARM LIGHT OPERATES NORMAL. NO INFLIGHT FAULTS LOGGED.SDR ASAA2012081492719Relay · failedAUTOPILOT A OR B WILL NOT ENGAGE INFLIGHT. ACFT GROUNDED. TROUBLESHOT TO STAB TRIM RELAY R64, REPLACED SAME. DFCS LIBRARY TEST 32 AND LAND VERIFY GO, ACFT REMAINS CAT III AUTOLAND/HGS. SCREW REFLECTS SAME.SDR ASAA2012081492718Actuator · failedNR 2 RAM AIR DOOR REMAINS CLOSED ON GROUND. ACFT GROUNDED. R & R RAM AIR DOOR ACTUATOR IAW AMM 21-51-21, OPS CHECKED GOOD, GROUND VERIFICATION GOOD IAW AMM 21-51-21.SDR ASAA2012081192693Fuel Control · malfunctionedCREW REPORTED VIA ACARS MSG THAT APU WOULD NOT START AND FAULT LIGHT ILLUMINATED AT 33,000. APU STARTED ON 3RD ATTEMPT. ACFT GROUNDED. APU BITE SHOWS NO CURRENT FAULTS & MSG 49-41010 (NO ACCELERATION) FOR THE PREVIOUS 2 FAILED STARTS. (COLD SOAKED). APU BITSDR ASAA2012081292708Panel · damagedNR 1 ENGINE FAN DUCT PANELS AT 100, 300, 500 AND 1100 LOCATIONS HAVE PULLED THROUGH BOLTS, LOOSE BOLTS (2 LOC) AND LOOSE PANEL RESPECTIVELY. ACFT GROUNDED. TIGHTENED PANELS AT 100, 300 & 500. REPLACED PANEL AT 1100 IAW AMM 72-23-07-000-801-F00.SDR ASAA2012081292707Lens · dislodgedEXIT LIGHT/SIGN OVERHEAD MID-CABIN COVER FELL OFF. ACFT GROUNDED. REINSTALLED COVER & OPS NOW NORMAL.SDR ASAA2012081292706Filter · bypassingDURING PDC, FOUND THE NR 2 ENG IDG DPI INDICATOR EXTENDED. ACFT GROUNDED. PERFORMED TASK 12-13-21-200-802. REMOVED THE NR 1 ON THE DPI RESET DECAL, RAN ENGINE NO LEAKS NOTED DPI REMAINS SET. OK FOR SERVICE.SDR ASAA2012081392704Actuator · faultedRIGHT PACK LIGHT ILLUMINATED DURING RECALL CHECK. RT PACK LIGHT WENT OUT WHEN MASTER CAUTION RESET. ACFT GROUNDED. ACCOMPLISHED FIM 21-62 TASK 801. FOUND RAM AIR ACTUATOR FAULT. RESET FAULT. BITE TEST GOOD.SDR ASAA2012081092697Striker · gougedFOUND FORWARD OTBD ECS STRIKER PLATE WORN. ECS LOWER CHORD WORN BY ECS DOOR LATCH. ACFT GROUNDED. DAMAGE AT ECS DOOR FWD OTBD STRIKER PAD MEASURES, .065D X .300 .DIAMETER.DAMAGE EXCEEDS LIMITS REF SRM 53-40-71, AD 1. ACCOMPLISHED EA 800-53EA-08540 (REPAIR OSDR ASAA2012081092695Probe · failedDIAGNOSTICS REPORTS NR 1 ENGINE TREND DATA SHOWS A SUDDEN SHIFT IN EGT HOT DAY MARGIN. ACFT GROUNDED. PERFORMED FIM TASK 77-05-00-810-801-F00, STEP E (8) (B). RESULTS ARE S-1 83.56, S-2 63.34, S-3 62.51, S-4 109.20. TASK PERFORMED ON 3 HRS AFTER ENG NR 1SDR ASAA2012081092694Eec · malfunctionedFOUND MESSAGE NR 73-11282 EEC CHANNEL IS NOT ENERGIZED WITH THE ALTERNATOR VOLTAGE ON ENGINE NR 2. ACFT GROUNDED. FOR ENGINE NR 2 ACCOMPLISHED FIM 73-27-00-810-805-F00. ONLY 1 OCCURRENCE OF THIS FAULT LOGGED IN FAULT HISTORY. AFTER ENGINE RUN AND EEC TEST, FSDR ASAA2012081092692Battery · inoperativeAPU WILL NOT START. ACFT GROUNDED. R & R STARTER GENERATOR IAW AMM 49-41-21-000-801 & 49-41-21-400-801. STARTER OPS CHECKED GOOD ON GROUND POWER. AFTER SWITCHING OFF APU GENERATORS, APU AUTO SHUTDOWN. PERFORMED APU BITE PROCEDURE 49-60-00-810-801. FOUND FSDR ASAA2012081092691Valve · failedON CLIMB OUT DUCT PRESSURE INDICATORS WERE DISCREPANT BY 20 PSI (RGT=18PSI & LT=38PSI). IN CRUISE AT FL 360 DISCREPENCY WAS 14 PSI (RGT=22 PSI & LT=36 PSI). ACFT GROUNDED. ACCOMPLISHED TASK CARD NG-36WC-00001. FOUND PRSOV AND PRECOOLER CONTROL VALVE BAD. R SDR ASAA2012081092690Radar · unknownRADAR DISPLAY HAS NUMEROUS SPOKES IN WEATHER MODE, AUTO STAB, TILT NEAR -1 TO 1. ACFT GROUNDED. UNABLE TO DUPLICATE WRITE-UP. WEATHER RADAR SYS OPS CHECKED GOOD IAW MM 34-43-00.SDR ASAA2012081192689Warning Light · false activationELECTRIC FAULT LIGHT ILLUMINATED DURING POWER UP. ACFT GROUNDED. PERFORMED ELECTRIC LIGHT MESSAGE LIGHT CHECK IAW FIM 24-31-00. SPCU INOPERATIVE I CODE FAULT. CODE CLEARED, NO FURTHER DEFECTS NOTED.SDR ASAA2012081192688Control Panel · inoperativeAUTOPILOT LIGHT WILL NOT ILLUMINATE. ACFT GROUNDED. R & R DFCS MODE CONTROL PANEL IAW AMM 22-11-34, OPS CHECK GOOD IAW AMM 22-11-34-740-801, LRU INTERFACE TEST AND 22-11-00 LAND VERIFY TEST, ACFT IS AUTOLAND AND HGS CAT III QUALIFIED.SDR ASAA2012080192650Detector · inoperativeAPU DETECTOR INOPERATIVE LIGHT ON. REMOVED DEFECTIVE DETECTOR IAW AMM 26-15-01-400-802. GROUND VERIFICATION SUCCESSFUL. PERFORMED OPS CHECK IAW AMM 26-15-00. TESTED OK.SDR ASAA2012070992508Coupler · looseNR 1 AND 2 HF RADIOS TESTED UNSATISFACTORY ON BOTH HEADS. ACFT GROUNDED. NR 1 AND 2 HF RADIO CHECK LOW AND HIGH FREQUENCIES WERE 2 X 2, VISUALLY INSPECTED ANTENNA AND COUPLER ATTACHMENT POINTS, NO DEFECTS FOUND. FOUND 1 & 2 HF COAX DISCONNECTS AT E8-1 RACK LOSDR ASAA2012070992515Battery Pack · failedWHILE ACCOMPLISHING EMERGENCY LIGHTS OPS CHECK. FOUND LEFT AFT BATTERY PACK INOP/FAILED TEST. R & R LEFT AFT BATTERY PACK. OPS CHECKED GOOD. REF AMM 33-51-06-960-805.SDR ASAA2012070992514Fmc · malfunctionedUNABLE TO LOAD FMCS. VERIFIED DEFECT, CYCLED NR 1 & 2 FMC CIRCUIT BREAKERS, BOTH OPS NORMAL REF MM 34-61-00. NO HISTORY PAST 30 DAYS. VERIFICATION FLIGHT SUCCESSFUL.SDR ASAA2012070992510Transceiver · failedWEATHER RADAR FAILED, BOTH SIDES. R & R WEATHER RADAR TRANSCEIVER IAW AMM 34-43-41. OPS CHECKED NORMAL IAW AMM RE 34-43-00.SDR ASAA2012070892509Apu · malfunctionedAPU WILL NOT CARRY PNEUMATIC LOAD. PERFORMED APU BITE IAW FIM 4960-TASK 801 APU FAULTED 49-31171, FCU DISAGREES WITH COMMAND. C/W FIM 49-31-00-810-808 THROUGH F(1)(E) 1, NO FAULTS FOUND.SDR ASAA2012070792505Panel · looseNR 2 ENG FAN BLADE INSPECTION FOUND THREE LOOSE SCREWS IN NOSE COWL LOWER OTBD VENT PANEL AT 6 O`CLOCK POS (ALF) (M), POSSIBLE DAMAGE TO SCREW HOLES IN PANEL. ACFT GROUNDED. REMOVED LOOSE LOCK FASTENERS AND REPLACED WITH LOCK BOLTS IAW EA 800-71EA-09724. SDR ASAA2012070792504Fastener · looseNR 2 ENGINE FAN BLADE INSPECTION. FOUND TWO FASTENERS LOOSE ON OTBD COWL AFT LIP AT 2 O`CLOCK POS (ALF) (M). ACFT GROUNDED. INLET COWL REPLACED.SDR ASAA2012070792499Computer · failedFIRST OFFICER FMC FAIL FOLLOWED CHECKLIST UNABLE TO RESTORE RNP REMAINED 10.0 FOLLOWED BY 2.0 ANP 0.02. - VERIFIED DEFECT, R & R NR 2 FMC REF MM 34-61-02, OPS CK NORMAL.SDR ASAA2012070792498Warning Light · false activationAFTER ENGINE START, RECEIVED AN FMC DISAGREE LIGHT. RAN QRH PROCEDURE. LIGHT CLEARED, CONTINUED NORMAL OPERATIONS.SDR ASAA2012070792497Fmc · malfunctionedFMC DISAGREE LIGHT ILLUMINATED ON TAXI OUT. PULLED CIRCUIT BREAKERS IAW CHECK LIST RESET LIGHT OUT, REBOOT FMC, NO FURTHER LIGHTS.SDR ASAA2012070792488Generator · failedNR 2 ENGINE GENERATOR OFF BUSS BLUE LIGHT AND NR 2 SOURCE OFF AMBER CAME ON IN FLIGHT WITH ASSOCIATED ELECTRICAL AMBER MASTER CAUTION LIGHT. PERFORMED QRH PROCEDURE AND NR 2 ENGINE GENERATOR OFF BUSS BLUE LIGHT REMAINED ON, AS WELL AS AMBER SOUCE LIGHT. STARTSDR ASAA2012070792487Eec · failedIN CRUISE, THE A/T LIM ADVISORY LIGHT ILLUMINATED. NO OTHER INDICATIONS. ON BITE TEST, THREE FAULTS LOGGED, MESSAGES 22-31410, 22-31512 AND 22-31411. A/C FROM BATTERY OFF WHEN GROUND POWER APPLIED ENG 1 ALTN POWER CHANNEL B CIRCUIT BREAKER TRIPPED. NR 1 EESDR ASAA2012070692503Hmu · faultyWHILE ACCOMPLISHING T/C 78273000, FOUND FAULT 75-20581, TBV DEMAND AND POSITION SIGNAL DISAGREE. FAULT CAUSES ENG CONTROL LIGHT. NO GO FAULT NR 1 ENGINE. ACCOMPLISHED FIM 75-23, TASK 801, NO FAULTS FOUND, ALL VALUES WITHIN LIMITS DUE TO HISTORY OF TBV AND LSDR ASAA2012070692483Control Valve · failedRT PACK LIGHT ILLUMINATES ON MASTER CAUTION RECALL. EXTINGUISHES WHEN MASTER CAUTION RESET. PERFORMED PACK/ZONE TEMP CONTROLLER BITE TEST IAW MM 21-61-00. CONFIRMED FAULT, FOUND HARD FAIL ON NR 2 CONTROLLER, THIS PACK TEMP CONTROL VALVE. R & R TEMP CONTROLSDR ASAA2012070592502Filter Element · dirtyAPU OIL FILTER INDICATOR SERVICING REQ. R & R APU OIL FILTER, RESET INDICATOR IAW AMM 49-91-13.SDR ASAA2012070592501Exciter · failedAPU FAULT LIGHT ILLUMINATED ON START ATTEMPT. WAITED 5 MIN, FAULT LIGHT EXTINGISHED ATTEMPTED SECOND START, FAULT LIGHT ILLUMINATED AGAIN. R & R APU IGNITION UNIT, IGNITER PLUG, AND IGNITION LEAD IAW AMM 49-41-31, 49-41-51 AND 49-41-52. PERFORMED APU STARTISDR ASAA2012070592476Controller · malfunctionedRT PACK LIGHT ILLUMINATES ON MASTER RECALL RECALL-EXTINGUISHES WHEN MASTER CAUTION IS RESET. NR1 CONTROLLER SHOWS STANDBY CONTROLLER FAULT, NR2 CONTROLLER SHOWS TCV FAULT. BOTH FAULTS RESET,VERIFIED. RAN BOTH PACKS REF MM 21-61-00, OPS NORMAL, SAME. GROUNDSDR ASAA2012070492469Sensor · malfunctionedNR 2 ENGINE VIBRATION INDICATION INTERMITTENTLY BLANKS NO INDICATION. ACFT GROUNDED. AVM LOGGED MULTIPLE N2 RPM SIGNAL LOSS NR 1 AND NR 2 ALSO LOGGED MULTIPLE ENG 2 N2 SIGNAL LOSS MAINT MSG 31-63160. R & R N2 SENSOR REF AMM 77-11-02, LEAK AND OPS CHECKED GOOSDR ASAA2012070492468Regulator · failedWITH ENGINES RUNNING, NR 1 BLEED AIR DOES NOT SHUT OFF WHEN NR 1 BLEED SWITCH SELECTED TO OFF. ACFT GROUNDED. ALTERNATE DEACTIVATION PROCEDURES USED IAW CH 5, TABLE 3, ITEM 1, 3, 4. REPLACED THE NR 1 ENGINE BLEED AIR REGULATOR IAW MM 36-11-03. OPS CK GOODSDR ASAA2012073192638Indicator · false indicationON PDC WALK AROUND FOUND NR 1 ENGINE DPI ON IDG EXTENDED. REMOVED NR 1 IDG SCAVENGE FILTER IAW AMM 24-11-41-000-801. INSPECTED IAW AMM 24-11-41-200-801, NO DAMAGE OR CONTAMINATION FOUND. INSTALLED NEW FILTER AND SERVICE IDG, RUN ENGINE AND LEAK CHECKED, NO SDR ASAA2012073192640Warning Message · false activationON TAXIOUT OGG FMC DISAGREE LT ILLUMINATED. PERFORMED QRH AND ALL OPS NORMAL.SDR ASAA2012073192639Warning Message · false activationFMC DISAGREE MESSAGE ON TAXI. CLEARED IAW QRH.SDR ASAA2012073092637Filter · cloggedNR 1 ENGINE IDG DELTA P EXTENDED. R & R NR 1 ENG IDG SCAVENGE AND CHARGE FILTER. REF FIM 24-11-00-810-803.SDR ASAA2012070392461Sensor · malfunctionedAPU FAULT LIGHT ILLUMINATED. TWO RESTARTS WERE ATTEMPTED AFTER FIVE MINUTE INTERVALS IAW ATTEMPT. AFTER EACH ATTEMPT WITH APU SWITCH OFF, FAULT LIGHT EVENTUALLY EXTINGUISHES. R & R MAIN & AUXILIARY BATTERIES. ACCOMPLISHED OPC CHECK OF MAIN AUXILIARY BATTERISDR ASAA2012070392464Start Valve · failedNR 2 ENGINE WOULD NOT START, NO ROTATION. R & R NR 2 ENGINE START VALVE IAW MM 80-11-03-00-801-F00. OPS AND LEAK CHECKED GOOD.SDR ASAA2012073192651Connector · damagedDURING INITIAL COCKPIT PREFLIGHT, BLUE ANNUNCIATIOR ENG VALVE CLOSED IS IN BRIGHT ILLUMINATION ONLY. NR 1 ENGINE PRESS TO TEST FUNCTION IS NOT WORKING CORRECTLY. ACFT GROUNDED. VERIFIED DISCREPANCY REF FIM 73-06, TASK 804. FOUND AT NR 1 HMU M1823 PIN 3 MISSI
Back to Boeing 737-890