Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA11510679Control Valve · faultyAFTER BLOCKOUT AND ENGINE START RECALL MASTER CAUTION SHOWED LEFT AIR CONDITIOING PACK AMBER PUSH RESET OF MASTER CAUTION AND EXTINGUISHED. TEMP CONTROLLER HAS NR 1 TEMP CONTROL VALVE FAULT. REPLACED NR 1 SYSTEM TEMPERATURE CONTROL VALVE IAW AMM 21 51 10 400SDR ASAA11510680Warning System · false activationPRESSURIZATION AUTO FAIL & ALTN LIGHTS ON. ACCOMPLISHED FIM TASK 21 31 00 (DCPC) BITE OPS CHECK NORMAL. GRD VERIFICATION TEST NORMAL.SDR ASAA11510678Unknown · malfunctionedON TAXI OUT FMC DISAGREE LIGHT ILLUM. PERFORMED QRH PROCEDURE. OPS NORMAL.SDR ASAA2011111810702Floorboard · corrodedEXCESSIVE CORROSION OF UPPER SURFACE OF FLOORBOARDS. FABRICATED NEW PANEL. AIRCRAFT GROUNDED.SDR ASAA11510684Filter · dirtyNR 2 ENG IDG DPI IS EXTENDED. REPLACED SCAVENGE AND CHARGE FILTERS NR 2 ENG IDG REF MM 24 11 41 LEAK CHECKS GOOD.SDR ASAA11510683Filter · dirtyNR 1 ENG IDG DPI IS EXTENDED. REPLACED SCAVENGE AND CHARGE FILTERS NR 1 ENG IDG. GOOD LEAK CHECK REF MM 24 11 11.SDR ASAA11510682Unknown · malfunctionedCON CAB ZONE TEMP ON AT RECALL RESETS WITH MASTER CAUTION. CONFIRMED. NR 2 CTRLR SHOWS FLT DECK TRIM VALVE FAULT ON BIT & PREV FLT. VERIFY TEST GOOD. RESET FAULT. FAULT DID NOT RETURN. BITE TEST NR 2 CNTRLR GOOD. FUNCT CHECK FLT DECK TRIM VALVE GOOD. GNSDR ASAA11510687Start Valve · faultyNR 1 ENGINE NO ROTATION WHEN START SWITCH PLACED TO GRD. REPLACED NR 1 ENG START VALVE PER AMM 80 11 03 000 801 F00. OPS & LEAK CHECK GOOD.SDR ASAA11510685Anti-Ice Valve · faultyDURING DESCENT FROM ABOUT 27,000' WHEN THE ENG ANTI ICE WAS TURNED ON THE NR 1 ENG ANTI ICE VALVE STAYED BRIGHT BLUE. SWITCH WAS CYCLED VALVE DID NOT CLOSE CORRECTLY BUT NOT OPEN. AFTER LANDING PILOT NOTED ON POST WALK AROUND THAT BOTH ENG COWLS WERE WARM ABSDR ASAA11510686Unknown · malfunctionedFMC POS SHIFT PG 3/3 SHOWS NO FMC GPS IRS DATA. SUSPECT POS SHIFT PG DISPLAYED IN AIR ONLY. POS REF PG 2 SHOW LAT AND LONG FOR ALL SENSOR. ACCOMPLISHED FMC BITE PER FIM 34 61 TASK 801 SENSORS AND IN FLIGHT FAULT SHOW NO FAULTS. A/C OK FOR SERVICE.SDR ASAA11510681Unknown · malfunctionedCONT CAB "ZONE TEMP" LIGHT COMES ON WITH RECALL AND CANCELS. FOUND NR 2 CABIN TEMP CONTROLLER LOGGED FLT DECK TRIM VALVE FAULT. ACCOMPLISHED TEMP CONTROLLER BITE REF MM 21 61 00 NO FAULTS FOUND. RESET FAULT FLIGHT DECK TEMP CONTROL OPS NORMAL.SDR ASAA11510675Idg · failedCOULD NOT ESTABLISH NR 2 ENGINE DRIVEN GENERATOR ON THE BUS AFTER PUSHBACK. NR 2 ENGINE DRIVEN GENERATOR 0 VOLTS 0 FREQS CONFIRMED. DRIVE LITGH GOES OUT & COMES BACK ON. NR 2 GCU SHOWS IDG FAULT. REQUIRES NR 2 ENGINE IDG REPLACMENT REF FIM TASK 24 21 00 81SDR ASAA11510673Control Valve · faultyLT PACK LGHT ON RECALL. PERF'D PACK/ZONE TEMP CONT BITE PROC 21 62 TASK 801 FOUND "THIS PACK TCV" FAULT ON NR 1 ON BITE AND PREV LEG. REF FIM TASK 21 62 00 810 830 REQ'S TEMP CNTL VLV REPLACEMENT. REPLACED TEMP CONTROL VLV REF MM 21 51 10 W. TCV TESTS GOODSDR ASAA11510674Warning System · false activationRT PACK LIGHT ILLUMINATED UPON RECALL AFTER ENGINE START. NR 2 CTC LOGGED TCV FAULT PERFORMED BITE TESTS GOOD FAULT CLEARED.SDR ASAA11510669Apu · making metalAPU WILL NOT START FAULT LIGHT ILLUMINATED. DURING T/S OF APU FAULT FOUND THE MAGNETIC DRAIN PLUG COVERED WITH MAGNETIC SILVER COLORED PARTICLES. IAW FIM TASK 49 91 81 200 801 APU REPLACEMENT IS REQUIRED. APU CHANGE COMPLETED. NO DEFECTS NOTED.SDR ASAA11510671Packing · brokenFOUND EVIDENCE OF OIL IN LEFT ENGINE COWL. FOUND OIL TANK FILLER NECK PACKING BROKEN. REPLACED OIL TANK FILLER NECK PACKING REF AMM 79 11 01. CREW RAN ENGINE NO LEAK FOUND.SDR ASAA11510670Shim · wornCOATING WORN ON NR 2 ENG FAN BLADE SHIMS. ON NR 2 ENGINE 24 EA FAN BLADE SHIMS P/N 340 252 307 0 ARE NOW INSTALLED REF T/C 78472002.SDR ASAA11510668Unknown · malfunctionedAT 0507 ZULU AT CRUISE FLIGHT RECEIVED FMC P/ RST INDICATION ON BOTH FORWARD DISPLAYED VTK ON CAPTS MAP DISPLAY ON FAILURE OF FMC INFO ON BOTH CDU'S. RAN QRH CHECKLIST AND SELECTED FMC SOURCE SWITCH TO BOTH ON RIGHT VNAV. VNAV PTA RESTORED ON ONE FMC POS REFSDR ASAA11510663Sliding Window · defectiveLEFT WINDOW HEAT OVERHEAT LIGHT ON. TURNED OFF FOR 5 MINS. TURNED BACK ON AND OVERHEAT LIGHT CAME ON AGAIN. WHCU LOGGED WINDOW SENSOR FAULT. CHECKED PRIM WINDOW SENSOR REF WDM 30 41 12. FOUND 325 OHMS. ALTERNATE WINDOW SENSOR FOUND TO BE 650 OHMS REF WDMSDR ASAA11510665Chain · brokenNR 1 ENG OIL TANK CAP LANYARD BROKEN. REPLACED OIL TANK CAP LANYARD/ CHAIN REF AMM 79 11 01 801 F00. NR 1 ENGINE.SDR ASAA11510662Filter Element · defectiveDURING THE ETOPS PDC FOUND NR 1 ENG IDG DELTA P INDICATOR WAS EXTENDED. ACCOMPLISHED FIM TASK 24 11 00 810 803. PERFORMED CHECK OF IDG SCAVENGE FILTER. VERIFIED BOTH ENG IDG DELTA P INDICATORS NOT EXTENDED.SDR ASAA11510661Unknown · malfunctionedLT PACK WARNING LIGHT ILLUMINATED UPON RECALL EXTINGUISHES WITH MASTER CAUTION RESET. NR 1 CONTROLLER FAULTED TCV. ACCOMPLISHED ZONE TEMP BITE NR 1 & 2 CONTROLLERS REF BITE PLACARD NO FAULTS. FAULT RESET.SDR ASAA1150658Idg · defectiveNR 1 GEN DRIVE LIGHT NOT ILLUMINATED WITH ENGINE OFF. DUPLICATED DEFECT. RANG OUT NR 1 IDG PRESS S/W AT DP1206 FOUND HIGH RESISTANCE AT S/W. ALSO JUMPED OUT PLUG PIN 5 & 6 AND DRIVE LIGHT COME ON. REF WDM:24 11 11. REPLACED NR 1 IDG REF AMM 24 11 11. OPSDR ASAA11510659Exciter · faultyAPU FAIL TO START WITH FAULT LIGHT ILLUMINATING. ACCOMPLISHED FIM 49 40 00 810 802. VERIFIED FAULT 49 41011 STILL ACTIVE. APU GOES THROUGH START SEQUENCE DOOR OPEN CRANKING AND FUEL FOG AT TAILPIPE BUT NO IGNITION SOUND NOTED. REPLACED APU EXCITER REF MM49SDR ASAA11510646Battery · faultyMAIN BATTERY SHOWS 27 VOLTS AND 1 AMP CHARGE THROUGHOUT THE FLIGHT. PERFORMED MAIN BATTERY CHARGER OPS TEST REF MM 24 31 21 710 801 OPS TEST GOOD. REPLACED MAIN BATTERY REF MM 24 31 11 000 802 002. BATTERY INSTALLATION TEST & GRD FUNCTIONAL TEST PASSED.SDR ASAA11510656Fmc · malfunctionedFMC CLOCK IS SHOWING 5HRS BEHIND CORRECT ZULU TIME. ACARS TIMES ARE REPORTING INCORRECTLY. PERFORMED FMCS OPS TEST TASK 34 61 00 710 801 OPS CHECK GOOD FMC'S ARE SHOWING CORRECT TIMES.SDR ASAA11510649Unknown · malfunctionedFMC DISAGREE MESSAGE ON FMC DURING TAXI OUT SMF. ACCOMPLISHED QRH PROCEDURE AND MESSAGE DISAPPEARED. OPS NORMAL.SDR ASAA11510648Unknown · malfunctionedCLIMBING OUT OF FL200 RT SIDE SIDE WINDOW OVERHEAT LIGHT CAME ON. COMPLIED WITH QRH AFTER 5 MIN IT WAS SWITCHED BACK ON, OVERHEAT LIGHT REMAINED EXTINGUISHED FOR THE ENTIRE FLT. PERFORMED WINDOW HEAT CONTROL UNIT SYSTEM TEST. NORMAL FUNCTIONS AND BITE TEST SDR ASAA11510645Unknown · malfunctionedFMC DISAGREE DISPLAYED ON GROUND. ACCOMPLISHED QRH PROCEDURE. LIGHT RESET. OPS NORMAL.SDR ASAA11510651Filter · defectiveAPU LUBE FILTER DELTA P INDICATOR EXTENDED. PERFORMED OIL FILTER INDICATOR INSPECTION. REPLACED LUBE FILTER ELEMENT NO CONTAMINANTS FOUND ON MAGNETIC DRAIN PLUG. RAN APU STILL NO CONTAMINANTS FOUND ON MAGNETIC DRAIN PLUG AND FILTER HOUSING INDICATOR REMAINESDR ASAA11510650Warning System · false activationAPU FAULT LIGHT ON START. PERFORMED APU BITE MX MES 49 41010. PERFORMED FIM TASK 49 40 00 810 801 NO ACCELERATION SHUTDOWN FOR FAULT 49 41010. NO OTHER FAULTS FOUND CURRENT STATUS NO FAULT FOUND. GROUND VERIFICATION OPS CHECKS NORMAL. OK FOR CONTINUED SERVSDR ASAA11510647Unknown · malfunctionedENGINE NR 1 "A" FIRE LOOP WILL NOT TEST. COULD NOT DUPLICATE DEFECT. ENG/APU FIRE OVERHEAT WARNING OPS NORMAL FROM CONTROL STAND P8 OPS NORMAL AND MODULE M279 OPS NORMAL REF FIM 26 10 00 810 801.SDR ASAA11510643Hmu · malfunctionedCLIMB THROUGH APPROX 26500FT ENG NR 1 SURGED N1 EXCEEDANCE FOLLOWED BY ENGINE GOING TO NEAR IDLE. ENG FAILURE INDICATION APPROX 15 MINS INTO FLT. ENGINE LIMIT/SURGE/STALL CHECKLIST PERFORMED ENGINE STABILIZED AND OPERATED NORMALLY FOR RETURN TO SEA. DIV TIMSDR ASAA11510715Unknown · malfunctionedWHILE ON APPROACH TO 16R IN SEA ATTEMPTED TO MAKE A LEG INTERCEPT AND THE FMC FROZE. AFTER A FEW MOMENTS VTK SHOWED ON MAP DISPLAY AND A MAP SHIFT OCCURRED. FMC THEN DROPPED TO "HOME" (MENU) PAGE AND WAS UNRESPONSIVE. AFTER SEVERAL MINUTES FMC DID BECOME RESDR ASAA1150640Unknown · malfunctionedON TAXI GOT FMC DISAGREE WARNING. ACCOMPLISHED QRH PROCEDURE. OPS CHECK NORMAL.SDR ASAA11510636Eec · faultyBOXED A/T LIM ON UPPER DISPLAY ILLUMINATED. NO OTHER LIGHTS ILLUMINATED. ACCOMP FIM 22 32 TASK 815 AND A/T BITE PER FIM 22 31 TASK 801. INFLIGHT FAULTS FOR LEG 1 HAS MAINT MSG 22 31411 EEC 1B FAILURE. ACCOMP FIM 22 31 TASK 806 AND EEC BITE PER FIM 73 00 TSSDR ASAA11510637Starter · failedAFTER DE-ICING ON PUSHBACK COULD NOT GET THE NR 2 ENGINE TO START. WHEN PLACING START SWITCH TO GROUND PRESSURE WENT UP. NO N2 N1 ROTATION. START VALVE OPEN LIGHT ILLUMINATED. BLEEDS ARE OFF. REMOVED CRANK PAD VERIFIED BOTH UPPER AND LOWER STARTER GEARS ASDR ASAA11510635Unknown · malfunctionedAUTOTHROTTLES INOP AND WILL NOT REMAIN ENGAGED IN ANY PHASE OF FLIGHT. COULD NOT DUPLICATE. A/T LOGGED ON RELATED DEFECT FLT LEG ASM2 NR 22 31688 FAULT. ACCOMP CURRENT STATUS CK & PRECAUTIONARY PERFORMED SERVO MOTOR TEST NUMEROUS TIMES, ALL CHECK NML REF FISDR ASAA11510618Control Unit · malfunctionedELECTRIC LIGHT ILLUMINATED AFTER ENGINE START. PER BITE PROCEDURE ELEC LIGHT MESSAGE 24 31 TASK 801 FOUND SPCU TO BE INOP. ACCOMP FAULT ISOLATION OF SPCU PER FIM TASK 24 34 00 810 802 BY CYCLING C/B`S SPCU NORMAL & SPCU STANDBY. REACCOMP BITE PROCEDURE & ELSDR ASAA11510624Unknown · malfunctionedAFTER PUSHBACK ATTEMPTED TO START NR 2 ENGINE WITH IGNITION SWITCH IN THE L POS. HUNG START NO EGT RISE. COMPLIED WITH ABORTED ENGINE START QRL/QRH PROCEDURE. ALL CB'S WERE IN. SWITCHED THE IGNITION SWITCH TO THE R POS AND GOT A NORMAL ENGINE START ON BOTHSDR ASAA11510617Warning System · false activationLEFT PACK LIGHT ILLUMINATED DURING RECALL. TESTED PACK CONTROLLER LT SIDE HAD A TCV SENSOR FAULT. RESET CONTROLLER AND RAN SYSTEM IAW AMM 21 00 00 800 803 AND 21 00 00 800 804. GROUND FUNCTIONAL CHECK GOOD. NO FAULTS ON RECALL. RETESTED SYSTEM CONTROLLER SDR ASAA11510619Processing Unit · faultyEN ROUTE THE FUEL QUANTITY INDICATOR AND THE TOTAL QUANTITY INDICATOR WOULD BLANK FOR APPROX 30 SECONDS THEN COME BACK ON. ALL OTHER INDICATIONS ARE NORMAL. INFLIGHT FAULTS LOGGED FAULT CODE 28 41109 PROCESSOR FAILURE. FOLLOWED FIM 28 41 TASK 808 REPLACED FSDR ASAA11510625Sensor · dirtyLONG TIME FAULT 77 10842 "TOP RIGHT EGT SIGNAL OUT OF RANGE" FOUND ON ALL LEGS. PERFORMED EGT CLEANING PER AMM 72 21 00 201. INITIAL S1 S4 TEMPS 57 / 21 / 21 / 50 AFTER CLEANING TEMPS READ 42 / 17 / 18 / 38.SDR ASAA11510621Unknown · malfunctionedRIGHT FMC FAILURE. PERFORMED FIM 34 61 00 810 807. TESTS OK. INTERMITTENT FAILURE PER FIM. SUCCESSFUL GROUND VERIFICATION.SDR ASAA2011110310538Attach Bracket · damagedWHILE PERFORMING TSR 905670, FOUND OIL COOLER FIRE SHIELD BRACKET NUTPLATE SEVERED. R & R AFT LOWER APU OIL COOLER ATTACH BRACKET IAW CMM 49-20-00-450-011. NO FURTHER ACTION REQUIRED.SDR ASAA11510623Apu · failedFOLLOW UP TO REPORTS OF APU HOT START GROUNDED YES. PERFORMED APU FIRST STAGE TURBINE WHEEL INSPECTION WITH BOROSCOPE REF 49 21 00. FOUND NO WALKING OF TURBINE BLADES OR DEFECTS. PLUG REINSTALLED FROM AIR/OIL SEPERATOR ADAPTER IAW AMM 49 21 00. OPS AND LEAKSDR ASAA11510620Transceiver · defectiveRADAR SPOKES INTERMITTENTLY ALL QUADRANTS/RANGES/TILTS. CONFIRMED RADAR SPOKES. VERIFIED RECEIVER/TRANSMITTER COOL FAN OPERATES PER AMM 34 43 41 400 801 FAN CIRCULATES NORMAL. REPLACED RADAR RECEIVER/TRANSMITTER PER AMM 34 43 41 400 801. PERFORMED RADAR SYSDR ASAA11510616Controller · malfunctionedLEFT PACK LIGHT ILLUMINATED. RESET LT PACK/ZONE TEMP CONTROLLER PER MM 21 61 00 AND TESTED SYSTEM, SYSTEM OP CHECKS GOOD. NO DEFECTS NOTED.SDR ASAA11510615Autothrottle Sys · malfunctionedAUTO THROTTLES FAILED DURING TAKEOFF WOULD NOT RE-ARM. PERFORMED FIM TASK 22 32 00 810 819 NO FAULTS AND NO CURRENT STATUS FAULTS PERFORMES A/T SYSTEM OPERATIONAL TEST PER M/M 22 31 00 OPS CHECKS GOOD NO FAULTS.SDR ASAA1150614Autoland Sys · malfunctionedUNSAT AUTOLAND. AIRCRAFT LANDED 20 FEET TO THE RIGHT OF RUNWAY CENTER LINE 16R. FFR SHOWS NO PROBLEMS LAST LEG. ACCOMPLISHED DFCS LAND VERIFY AND HGS SYSTEM TEST REF MM 34 36 00. OPS NORMAL.
Back to Boeing 737-890