Boeing 737-890
Service difficulty reports · 23,038
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737890' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA11510544Stator · defectiveWHILE ACCOMPLISHING TASK CARD 78273000 ENGINE NR 2 LOGGED SHORT TIME FAULT CODE 73 21272 (THE ALTERNATOR VOLTAGE INPUT TO THE EEC IS OUT OF RANGE.) PERFORMED FIM TASK 73 27 00 810 804 F00 ALTERNATOR VOLTAGE INPUT TO THE EEC IS OUT OF RANGE. AT STEP F3 FOUND SDR ASAA11510517Unknown · malfunctionedON TAXI OUT FMC DISAGREE LIGHT ILLUMINATED. ACCOMPLISHED QRH AND FMC DISAGREE LIGHT ON BOTH ND'S EXTINGUISHED.SDR ASAA11510514Transceiver · malfunctionedPWS FAIL LIGHT ILLUMINATED DURING PREFLIGHT. ADDITIONALLY WX RADAR SHOWS FAULT INDICATION "RT" ON DISPLAY DURING T/S. PERFORMED FIM TASK 34 43 00 810 815 PREDICTIVE WINDSHEAR SYSTEM PROBLEM FAULT ISOLATION AND TASK 34 43 00 710 802 001 WEATHER RADAR SYSTEM OSDR ASAA11510516Unknown · malfunctioned"FMC DISAGREE" ON BOTH NAV DISPLAYS ON GROUND. PERFORMED QRH PROCEDURE. LIGHT RESET. OPS NORMAL.SDR ASAA11510515Unknown · malfunctionedFMC DISAGREE AFTER PUSHBACK. ACCOMPLISHED QRH PROCEDURE. LIGHT RESET. OPS NORMAL.SDR ASAA11510512Control Valve · defective20PSI DUCT PRESS SPLIT AT FL370 (R 22PSI L 42PSI). REPLACED NR 2 ENGINE PRECOOLER CONTROL VALVE REF MM 36 12 02 000/400 801.SDR ASAA11510511Screw · out of balanceNR 1 ENGINE VIRBRATION 1.0 TO 1.1 GREATER THAN 1 MINUTE WHEN OPERATING AT MAX CONT THRUST. PERFORMED FAN TRIM BALANCE ON NR 1 ENGINE IAW ALASKA B737NG AMM 71 00 00 750 803 FOO. CHANGED NR 8 TO PO7 NR 18 TO PO7 NR 21 TO PO8 AND 28 TO PO8 USING NR T8484F. PESDR ASAA11510510Unknown · malfunctionedFMC DISAGREE LIGHT ILLUMINATED ON TAXI OUT. PERFORMED QRH ISSUE RESOLVED. AS A PRECAUTION CHECKED BOTH FMC FOR "FMC DISAGREE" NO DEFECTS NOTED. OK FOR CONT SERVICE.SDR ASAA11510509Detector · failedAMBER APU FIRE DET INOP LIGHT REMAINED ILLUMINATED AFTER APU STARTED. REPLACED APU TAILPIPE OVERHEAT DETECTOR ASSEMBLY REF MM26 15 01. TESTED OPS NORMAL.SDR ASAA11510504Sensor · leakingRIGHT BLEED TRIP OFF ILLUMINATED EARLY IN THE DESCENT PASSING THRU FL370 N1 WERE AT 63 PERCENT LEFT PACK PRESSURE AT 31 PSI. RESET 1 X THEN REILLUMINATED AGAIN WHILE IN THE DESCENT. REPLACED BLEED AIR OVERTEMP SENSOR INTERAL LEAK (450 THERMO) REF AMM 36 11 0SDR ASAA11510502Anti-Ice Valve · stuckON ENG START APU COULD ONLY GET N2 TO 22 PERCENT ON BOTH ENG'S. STARTED APU & TURNED APU AIR ON & HEARD LOUD HISSING NOISE FROM LT WING FOUND LT WING ANTI ICE VLV STUCK OPEN WITH NO INDICATION OF VLV OPEN. REPLACED LT WING ANTI ICE VLV REF MM 30 11 11, OPS CSDR ASAA11510501Actuator · malfunctionedCROSSFEED VALVE OPEN LIGHT ILLUMINATED FULL BRIGHT INTERMIT WITH CROSSFEED VALVE IN CLOSED POSITION NEVER GOES DIM BRIGHT ONLY. REPLACED CROSSFEED VALVE ACTUATOR PER AMM 28 22 21 400 804. OPS CHECK NORMAL PER AMM 28 22 21 710 810.SDR ASAA11510505Indicator · defectiveFOUND APU OIL FILTER INDICATOR EXTENDED. PERFORMED OIL FILTER INDICATOR SERVICING TASK REF AMM 49 91 13 600 801 RESET DPI INDICATOR. REPLACED LUBE FILTER ELEMENT REF AMM 49 91 12. RAN APU AND OIL FILTER INDICATOR EXTENDED AGAIN. REPLACED OIL FILTER INDICATSDR ASAA11510503Unknown · malfunctionedAFTER PUSHBACK FMC DISAGREE MESSAGE. PERFORMED PROCEDURE IN THE QRH. FMC OPERATION RESTORED.SDR ASAA11510495Circuit Breaker · trippedATTEMPTED AUTOLAND/HGS FAIL. 16L CRIT AREA CLEAR WIND CALM APP WARN IN HGS IN FLARE. TROUBLESHOT SYSTEM AND FOUND CIRCUIT BREAKER SYSTEM A FCC DC TO BE TRIPPED. RESET CIRCUIT BREAKER. OPS CHECK GOOD IAW ASA B737 NG FIM 34 36 00 810 807.SDR ASAA11510508Regulator · failedDURING CLIMB DUCT PRESSURE READ 43 PSI (R) & 20PSI (L). N1 100.2 / 100.2 N2 97.2 / 97.2. AT CRUISE DUCT PSI WAS 40 / 34. N1 88.6 / 88.6 N2 92.1 / 92.1. DESCENT 18 / 18 N1 41.2 / 40.8 N2 75.1 / 75.1. MATCHED DURING TAXI IN. DID NOT NOTICE ANY PRESSURE PROBLSDR ASAA11510507Fuel Control · leakingAPU HAS HISTORY OF OIL CONSUMPTION. CURRENT RATE IS .06QPH. TSR ISSUED. PERFORMED APU HIGH OIL CONSUMPTION RATE PER FIM 49 95 00 810 801. FOUND OIL LEAKING OUT OF FWD DRAIN AND IS COMING FROM FCU. PERF MAG DRAIN PLUG INSP PER AMM 49 91 81 200 801 APU FOUNSDR ASAA11510494Unknown · malfunctionedON ILS 7L. CHANNEL A SINGLE CHANNEL APPROACH. AUTOPILOT HAD A CONTINUOUS + 1 DEG PORPOISE IN PITCH. FROM 1600 FT TO 800 FT. I DISCONTINUED AUTOPILOT. TOWER SAID THEY HAD NO COMPLAINTS FROM OTHER AIRCRAFT. PERFORMED DFCS CURRENT STATUS QUICK TEST GRP 10 PER SDR ASAA11510493Unknown · malfunctionedAUTOLAND UNSUCCESSFUL LANDED TOO FAR LEFT OF CENTERLINE, ALSO AIRCRAFT PITCHED OVER IN LAST 50 FEET EXCESSIVELY. BUT DID MANAGE TO CORRECT. WINDS WERE CALM CRITICAL AREA CLEAR. UNABLE TO CONFIRM FAULT. 2 FAULTS RECORDED ON DATE OF DISCREPANCY ONE ADIRU FAULSDR ASAA11510488Indicator · defectiveAPU LUBE FILTER DIFFERENTIAL FILTER INDICATOR HAS HISTORY OF INDICATOR FOUND EXTENDED WITH FILTER FOUND CLEAN. REPLACED APU OIL FILTER INDICATOR PER AMM 49 91 13 000 802 LEAK & OPS CHECK GOOD INDICATOR DID NOT EXTEND WHILE APU OPERATED.SDR ASAA11510479Battery Pack · dischargedWHILE PERFORMING MAINT IAW TC 78233001 BATTERY PACK AND POWER SUPPLY AT M1675 PERFORMED UN SAT. REPLACED BATTERY PACK AND POWER SUPPLY AT M1675 TESTS GOOD. REF AMM 33 51 06.SDR ASAA11510492Panel · damagedREF T/C #78472000 NR 1 ENG INLET AND FAN BLADE INSP FOUND NR 1 STRUT PNL BETWEEN NR 1 AND NR 2 ENG STRUTS HAS ONE FASTENER PULLED THRU PANEL. REPLACED NR 1 STRUT PANEL BETWEEN NR 1 AND NR 2 ENG STRUTS PER AMM 72 23 07.SDR ASAA11510484Fmc · wornRIGHT FMC L6 BUTTON IS WORN AND HAS NO FEEDBACK DETENT WHEN PRESSED. REPLACED F/O'S FMCS CDU REF AMM 34 61 01. OPS CHECK NORMAL.SDR ASAA11510487Switch · failedDURING NR 1 ENG START ENGINE START SW FAILED TO TURN OFF AUTOMATICALLY AND START VALVE REMAIN OPEN AND FLASHING BEYOND 56 PERCENT N2. REPLACED NR 1 ENGINE START SWITCH REF WDM 80 11 11. NR 1 ENGINE START SWITCH TEST NML REF MM 80 11 00.SDR ASAA11510482Light · brokenF/A REPORTS FLUORESCENT LIGHT STRIP BEHIND FORWARD GALLEY IS BROKEN. REPLACED DAMAGED PHOTOLUMINESCENT STRIP BEHIND FWD GALLEY PER AMM 33 51 15 860 801, OPS CHECK GOOD.SDR ASAA11510486Eec · faultyABORTED START NR 1 ENG ALL PARAMETERS NORMAL BUT NO EGT RISE. QRC AND QRH PROCEDURES ACCOMPLISHED. START ATTEMPTS WERE ON IGN R LT ENG STARTS NORMAL ON IGN L. SWAPPED POWER SUPPLIES TO LT ENG EXCITERS NO FIX NO AUDIBLE ON IGN R. RESTORED TO ORIGINAL REF 74SDR ASAA11510481Unknown · malfunctionedRIGHT PACK LIGHT ILLUMINATED AND RIGHT PACK TRIPPED OFF ACCOMPLISHED ABNORMAL PROCEDURES AND RESET. PACK TRIPPED AGAIN AFTER 30 SECONDS. ABOVE OCCURRED AT GATE IMMEDIATELY PRIOR TO PUSH. PERFORMED BOTH AUTO TEMP CONTROLLERS BITE TEST AND NO FAULT LOGGED ON SDR ASAA11510483Transceiver · malfunctionedON PREFLIGHT PWS FAILED & WXR FAIL ILLUMINATED ON ND. REPLACED WX TRANSCEIVER PER AMM 34 43 41, OPS CHECK PER AMM 34 43 00.SDR ASAA11510485Hmu · faultyLEFT ENGINE LIGHT ON AFTER LANDING. RESISTANCE BETWEEN PIN 2D TO CONNECTOR SHELL OF CONNECTOR DP0501MODS LESS THAN 10M REF FIM TASK 75 23 00 810 801. FAULT CODE 75 10581. REPLACED NR 1 ENGINE HMU PER 737NG MM 73 21 10 400 801 NR 1 ENGINE CONTROL LIGHT "OFF"SDR ASAA11510475Window · faultyL SIDE WINDOW OVHT DURING FLIGHT. WOULD NOT RESET PER QRH. REPLACED CAPTS NR 2 OPEN ABLE WINDOW PER MM 56 12 11 400 801. ACCOMPLISHED OPS & FUNCTIONAL CHECKS NO DEFECTS NOTED. WINDOW HEAT OPS TEST GOOD PER MM 30 41 00 710 80. ACCOMPLISHED FLT DECK NR 2 WISDR ASAA11510476Unknown · malfunctioned"SINGLE FMC OPERATION" MSG DISPLAYED ON BOTH FMC'S. FMC RETURNED TO NORMAL AFTER PWR SWITCHING. OPS NORMAL.SDR ASAA11510474Unknown · malfunctionedCAPTAINS NR 2 WINDOW HOT TO TOUCH NO OVERHEAT LIGHT. MEASURED RESISTANCE FOR CAPT'S SLIDER WINDOW TEMP SENSOR (STBY) AND HEATER ELEMENT REF WDM 30 41 12 AND MM 30 41 21. ALL VALUES WITHIN LIMITS. CAPT'S SLIDER WINDOW HEAT OPS NORMAL REF MM 30 41 00.SDR ASAA11510462Probe · failedGE DIAGNOSTICS REPORTS NR 2 ENGINE TREND DATA CONTINUES TO SHOW A SHIFT IN DELTA CRUISE AND TAKE OFF MARGIN INDICATIVE OF EGT INDICATION ERRORS. PERFORMED TASK 77 21 01. FOUND T49.5 S3 PROBE FAULTY (HIGH RESISTANCE). INSTALLED NEW S3 PROBE REF 77 21 01. OPSDR ASAA11510478Floorbeam · corrodedFORWARD CARGO BAY FLOORBEAM TEE CORRODED BS 500I LBL 30 TRU RBL 30. REMOVED CORROSION ON FLOORBEAM TEE. ORIG MATERIAL .050, REMOVED .010, REMAINING .070 LENGTH 14 INCHES, WIDTH 1 1/2 INCHES. OUT OF LIMITS IAW SRM 53-00-53 PG 110. REMOVED AND INSTALLED TEE SDR ASAA11510469Module · faultyAUTOTHROTTLE SWITCH WILL NOT STAY IN ARMED POSITION AFTER REPEATED ATTEMPTS DURING CLIMB AND CRUISE.AUTOTHROTTLE CB (P18 E1) REMAINED ENGAGED. CURRENT STATUS COMES UP WITH ASM2 FAULTS AND FAULT HISTORY HAS NUMEROUS ASM2 FAULTS IN LAST TWO FLIGHT LEGS. REPLACSDR ASAA11510472Light · inoperativeWHILE ACCOMPLISHING TASK CARD 78233008 EMERGENCY LIGHTS OPS CHECK FOUND RIGHT AFT EXTERIOR OVERWING EMERGENCY LIGHT INOP. REPLACED RIGHT AFT EXTERIOR OVERWING EMERGENCY LIGHT BULB, OPS CHECK GOOD. REF AMM 33 51 04 990 801.SDR ASAA11510471Unknown · malfunctionedLEFT SIDE WINDOW OVERHEAT LT ON TURNED OFF THEN BACK ON AND OVERHEAT LT AGAIN. WHCU BITE SHOWS SENSOR FAULT. SWAPPED TO SPARE SENSOR AT WINDOW PER FIM 30 41 TASK 811. OPS CHECK FAIL. WHCU BITE NOW SHOWS P5 9 FAULT. SENSOR FAULT CLEARED. SWAPPED WHCU WITHSDR ASAA11510470Sensor · failedAFTER ENGINE START FWD WINDOW HEAT "OVERHEAT" LIGHT CAME ON. REFERRED TO QRH AND TURNED SWITCH OFF AND WAITED 2 MINUTES. PLACED SWITCH BACK ON AND OVERHEAT LIGHT CAME BACK ON. ACCOMPLISHED FIM 30 41 TASK 801. WINDOW SENSOR FAULT ILLUMINATED LAST SEVERAL LESDR ASAA11510622Nut Plate · severedWHILE PERFORMING TSR 905670 FOUND OIL COOLER FIRE SHIELD BRACKET NUT PLATE SEVERED. ON DEFERRAL.SDR ASAA11510576Trans Panel · corrodedAFT CARGO RT TRANSITION PANEL CORRODED. REPAIRED AFT CARGO RT TRANSITION PANEL IAW B737 800 SRM 53 00 53 REPAIR 5.SDR ASAA11510467Filter Element · defectiveNR 1 ENG IDG DELTA P INDICATOR EXTENDED. REPLACED ELEMENT FILTER AND IDG OIL. DUE TO HISTORY TSR ISSUED TO REPLACE IDG. REPLACED IDG IAW AMM 24 11 11 400 801. LEAK AND OPS CHECK GOOD IAW MM 24 11 00 700 802.SDR ASAA11510463Unknown · malfunctionedFMC DISAGREE ON GROUND. PERFORMED QRH PROCEDURE. OPS CHECK NORMAL.SDR ASAA1150460Battery · dischargedNO VOLTAGE TO BATTERY. REPLACED THE MAIN AND AUX BATTERY REF AMM 24 31 11, OPS CHECK NORMAL.SDR ASAA11510461Filter Element · defectiveAPU OIL FILTER INDICATOR PIN EXTENDED. REPLACED APU OIL FILTER AND INDICATOR PER AMM 49 91 13. OP'S CHECK AND LEAK CHECK GOOD.SDR ASAA11510459Unknown · malfunctionedFMC DISAGREE ON GROUND. PERFORMED QRH PROCEDURE. LIGHT RESET, OPS NORMAL.SDR ASAA11510452Power Unit · faultyDURING APU START ON EXT PWR O/BS'D BATTERY DISCHARGE LT "ON". VIS INSP'D START CONVERTER & START POWER UNITS IN E & E. OBS'D APU START CONV UNIT C/B ON P91 115VAC TRANSFER BUS 1 OUT (A 11). REPLACED START POWER UNIT MM 49 41 71 000 801 & 400 801. APU START SDR ASAA11510449Unknown · malfunctioned"FMC DISAGREE" MESSAGE DURING TAXI OUT. PERFORMED QRH PROCEDURE AND MESSAGE DID NOT RETURN.SDR ASAA1150447Unknown · faultyLEFT SIDE WINDOW OVERHEAT ILLUMINATED ON TAXI IN. CHECKED SPARE SENSOR & RESISTANCE IS WITHIN LIMIT REF MM FIM 30 41 00. REMOVED WINDOW FOR ACCESS TO SENSOR TERMINAL CONNECTOR. SWAPPED SENSOR TO ALTERNATE STUD. RE-INSTALLED WINDOW REF MM 56 12 11 CLOSED C/SDR ASAA11510454Window · crackedR1 OUTER PANE SHATTERED AT FL 360 OVER CINNY. ACCOMPLISHED QRH PROCEDURES. DIVERSION TIME: 1 HOUR 11 MIN. REPLACED R1 WINDOW PER AMM 56 11 11 801 AND 56 11 11 400 801. REPLACED RIGHT FWD WINDOW HEAT CONTROL UNIT PER AMM 30 41 11 000 801 AND 30 41 11 400 80SDR ASAA11510445Conduit · looseNR 2 ENG HYD PUMP DEPRESSURIZATION SOLENOID CONNECTOR CONDUIT LOOSE FROM CONNECTOR. SECURED CONDUIT TO NR 2 ENG HYD PUMP DEPRESS SOLENOID CONNECTOR. CLEANED & CONNECTED CONNECTOR. OPS CHECK SAME GOOD ON ENG RUN.
Back to Boeing 737-890