Service difficulty report · Unknown · Boeing 737890

Difficulty date
October 4, 2011
Submitted
October 6, 2011
Operation
Air carrier
Aircraft
N590AS
Make and model
Boeing 737890
Aircraft serial
35687
Aircraft time
13,949 hours, 4,419 cycles
Part
Unknown
Condition
Malfunctioned
Location
Window Heat
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT SIDE WINDOW OVERHEAT LT ON TURNED OFF THEN BACK ON AND OVERHEAT LT AGAIN. WHCU BITE SHOWS SENSOR FAULT. SWAPPED TO SPARE SENSOR AT WINDOW PER FIM 30 41 TASK 811. OPS CHECK FAIL. WHCU BITE NOW SHOWS P5 9 FAULT. SENSOR FAULT CLEARED. SWAPPED WHCU WITH R1 CONTROLLER. NO HELP AND SWAPPED BACK. SWAPPED COIL CORDS NO HELP. REMOVED AND RE-INSTALLED P5 9 OVERHEAD PANEL AND OPS CHECK GOOD. RAN L2 AND R1 SYSTEMS FOR 30 MIN AND CYCLED ACFT POWER. OPS STILL GOOD. TURNED POWER OFF FOR 10 MIN AND THEN BACK ON. OPS STILL GOOD. BOTH SYS OPS GOOD PER AMM 30 41 00.