SDR ASAA0956810Wire · damagedRT FWD WINDOW OVERHEAT LIGHT ILLUMINATED WITH ASSOCIATED WARNINGS. CB WINDOW CONTROL POPPED. AIRCRAFT WAS FL 40.0 2 HOURS AND 20 MINUTES INTO FLIGHT. PERFORMED FIM TASK 30 41 TASK 813. FOUND BAD CRIMP ON TERMINAL AT C/B 394 ON LOAD SIDE. REPLACED C/B AND SDR ASAA0956809Terminal · looseRIGHT FWD WINDOW OVERHEAT LIGHT ILLUMINATED. C/B P6 12 B8 POPPED. FOUND RT FRONT WINDOW HEAT PWR C/B OUT. R1 TEMP CONTROLLER SHOWS BUS POWER FAULT. FOUND UPPER I/B GND TERM AT R1 WINDOW LOOSE. SECURED SAME. RESET C/B. OPS CHECK WINDOW HEAT (R1) GOOD. BSDR ASAA0956808Spinner · damagedWHILE PERFORMING T/C 78472000 ENGINE INLET INSP FOUND NR 2 ENG FRONT SPINNER CONE MISSING APPROX MORE THAN 20 PERCENT OF BLACK ANODIZING COATING. REPLACED NR 2 ENGINE FOR PERFORMANCE POSITIONING.SDR ASAA0956797Warning Message · illuminatedFMC DISAGREE DISPLAYED F/O'S SIDE ON THE GROUND. ACFT GROUNDED. FLIGHT CREW PERFORMED QRH PROCEDURE. OPS NORMAL.SDR ASAA0956795Warning System · malfunctionedAT TOP OF DESCENT RECEIVED SINGLE FMC OPS IN BOTH SCRATCHPADS ACCOMPLISHED QRH PROCEDURE. FMC BOTH ON CPT. GROUNDED YES. ACCOMPLISHED FIM TASK 34 61 00 810 807 FMC HARDWARE/SOFTWARE FAULTS INITIAL EVALUATION. ALSO PERFORMED FMC SYSTEM OPERATIONAL TEST REF SDR ASAA0956794Warning System · malfunctionedFMC DISAGREE LIGHT ON DURING TAXI. GROUNDED YES. FLIGHT CREW PERFORMED QRH PROCEDURE OPS NORMAL.SDR ASAA0956793Outflow Valve · failedSHORTLY AFTER TAKEOFF AUTOFAIL LIGHT ON OVERHEAD PRESSURIZATION CONTROL PANEL ILLUMINATED. CHECKLIST ACCOMPLISHED AND OPERATED IN ALTN MODE. CB FOR AUTO CONTROLLER 2 IS POPPED GROUNDED YES. CONFIRMED FAULT. NR 2 AUTO MODE MOTOR ON OUTFLOW VALVE OPS C/B REFSDR ASAA0956788Autopilot Sys · malfunctionedAUTOLAND EVAL ATTEMPTED ON SEA 34L. A/P SEEMED TO PITCH DOWN A LITTLE TOO MUCH AT ABOUT 100' AGL SHOWING NO SIGNS OF CORRECTING. HGS GAVE "APP WARN" COUPLE OF SECONDS LATER. DISCONNECTED A/P AND LANDED MANUALLY. ATC SAID ILS 34L WAS OPERATING NORMALLY AND ILS SDR ASAA0956787Terminal · looseON TAXI THE L SIDE WINDOW OVERHEAT LITE ILLUMINATED. GROUNDED YES. O/H LITE COMES BACK ON AFTER WINDOW COOLED DOWN IN ABOUT 5 10MINS. WHCU SHOWS SENSOR FAULT. FOUND TEMP SENSOR TERM LOOSE. SECURED SAME. REF FIM 30 41 00 810 811.SDR ASAA0956775Unknown · malfunctionedWHEN "OFFSET" USED FOR LATERAL DEVIATIONS LNAV ENGAGED AIRCRAFT ASSUMES A 30 DEG ANGLE OF BANK TURN REGARDLESS OF ANGLE OF BANK SELECTED ON THE HEADING KNOB. FOUND FAULT CODE 22 11822 PERFORMED FIM 22 11 00 810 811. OPS TEST NORMAL.SDR ASAA0956743Transceiver · faultyHF NR 1 WILL NOT TRANSMIT. RECEIVES OK DATA TRANSMIT OK. VERIFIED NR 1 HF RADIO INOP. REPLACED NR 1 HF TRANSCEIVER PER MM 23 11 21 400 801. REPLACED NR 1 HF ANTENNA COUPLER PER MM 23 11 61 400 801. BOTH OPS CHECK NORMAL. PART NUMBERS VERIFIED BY SEAMC RESDR ASAA0956742Skin · damagedLIGHTNING STRIKE CAUSED BURN MARK AT STA 1016 ON BOTTOM OF FUSELAGE. REPAIRED BURN MARK.SDR ASAA0956741Sense Line · leakingFOLLOW UP TO REPORTS OF LT DUCT PRESS LOW ON CLIMBOUT AND CRUISE. ACCOMPLISHED HEALTH CHECK LT PRECOOLER CONT VALVE. CHECKS GOOD REF M/M 36 12 00 700 801. FOUND LT PRSOV CONTROL PRESSURE SENSE LINE PART 16135 83 LEAKING. REPLACED SENSE LINE. OPS & LEAK CHSDR ASAA0956740Filter · malfunctionedNR 2 IDG DIFFERENTIAL PRESSURE INDICATOR IS EXTENDED. REPLACED SCAVANGE AND CHARGE FILTERS AND RESET INDICATOR PER MM 24 11 41. INSPECTED FILTERS AND FOUND NO CONTAMINATION OIL SHOWED NO EVIDENCE OF BURNING. DOCUMENTED FIRST OCCURRENCE ON PLACARD AND VERIFISDR ASAA0956739Warning System · activatedFMC DISAGREE ILLUMINATED. QRH CHECKLIST ACCOMPLISHED ON GROUND. OPS NORMAL.SDR ASAA0956738Eec · malfunctionedWHEN CLIMB POWER SELECTED NR 1 THRUST LEVER ADVANCES BEYOND CLIMB POWER & AUTO THROTTLES DISCONNECTED. A/T LIMIT IS ANNUNCIATED. EEC 1 CHANNEL A IS INOP. REMOVED AND REPLACED NR 1 ENG EEC PER AMM 73 21 60 000 801. GROUND VERIFICATION FOR EEC GOOD. NO DEFESDR ASAA0956736Filter · pluggedTHE "AFT CAB" TEMPERATURE CONTROL KNOB HAD TO BE TURNED APPROXIMATELY 90 PERCENT AVAILABLE LIMIT TO KEEP CABIN AT COMFORTABLE TEMPERATURE. OPS CK PER AMM 21 61 00 700 807 002 FAULT VERIFIED. FOUND AFT CABIN TEMP SENSOR FILTER PLUGGED. REPLACED FILTER PER TASDR ASAA0956737Warning System · malfunctionedRIGHT PACK LIGHT ILLUMINATED ON MASTER CAUTION RECALL. PACK LIGHT GOES OUT ON MASTER CAUTION RESET. TCV FAULT NR 2 ZONE TEMP CONTROLLER. RESET AND TESTS NORMAL PER FIM 21 62 TASK 803.SDR ASAA0956726Plate · chafedLOWER CHORD CHAFED AT CUTOUT FOR ACCESS DOOR NR 192 DR AT STRIKER PLATE. REMOVED DAMAGE AND INSTALLED FABRICATED PARTS.SDR ASAA0956701Unknown · malfunctionedTHE "WXR STAB" YELLOW FAULT LIGHT ON WHEN OPERATING RADAR. PERFORMED FIM TASK 34 43 00 SYSTEM OPS NORMAL. A/C OK FOR SERVICE. NO HISTORY PAST 30 DAYS SEAMC NOTIFIED.SDR ASAA0956711Stator · out of toleranceNR 2 ENGINE SHOWS FMC CDU SHORT TIME FAULT CODE 73-21272 "THE ALTERNATOR VOLTAGE INPUT TO THE EEC IS OUT OF RANGE". PLT DEFERRED MAINT. REPLACED STATOR ALTERNATOR AND ROTOR ALTERNATOR REF MM 73-21-08-000-801-F00. REQ TESTS 13-3A ACCOMPLISHED INSTALLATION OFSDR ASAA0956702Transceiver · malfunctionedRADAR HAS 2 4 SPOKES AT 10:00 O'CLOCK POSITION INTERMITTENTLY ON CAPTS DU F/O SIDE OK RADAR APPEARS TO PAINT NORMALLY. FOUND SPOKES ON BOTH DU'S INTERMITTENTLY APPEAR. DUE TO PREVIOUS TROUBLESHOOTING REMOVED AND REPLACED WXR R/T REF M/M 34 43 41. GROUND VERSDR ASAA0956700Isolation Valve · faultyHEARD LOUD NOISE COMING FROM ENGINE BLEED AIR ISOLATION VALVE. REMOVED AND REPLACED ENGINE BLEED AIR ISO VALVE REF AMM 36 10 04. VERIFIED PART WITH SEAMC IPC 36 10 04.SDR ASAA0956698Filter Element · defectiveAPU LUBE FILTER BUTTON INDICATOR EXTENDED DURING CHECK. REMOVED LUBE FILTER ELEMENT FOUND NO EVIDENCE OF CONTAMINATION FOUND. INSTALLED NEW FILTER ELEMENT AND REPLACED LUBE FILTER HOUSING ASSY DUE TO DAMAGE ON THE LUBE FILTER HOUSING. SECURED AND LEAK CHECKSDR ASAA0956697Transceiver · faultyHF1 DIFFICULT TO TRANSMIT ON, IT TAKES MULTIPLE ATTEMPTS TO ESTABLISH A TRANSMISSION. RECEPTION IS NORMAL. HF2 WORKS NORMALLY. NR 1 HF FAULT PER FIM 23 11 00 810 806 "FAIL" SHOWED ON RADIO TUNING PANEL INTERMITTENTLY DURING TRANSMIT. REPLACED AND TESTED NR SDR ASAA0956696Unknown · malfunctionedREF TC 78273000 NR 2 ENGINE SHOWS FMC CDU SHORT TIME FAULT CODE 73 21272 "THE ALTERNATOR VOLTAGE INPUT TO THE EEC IS OUT OF RANGE". REF FIM TASK 73 27 00 810 804 FOO REPAIR CONFIRMATION SHOWS NO FAULTS. MAINT HISTORY ON FMC CDU SHOWS ONLY ON ORIGINAL LEG. NSDR ASAA0956695Warning System · malfunctionedOVERHEAD PANEL ELEC INDICATOR LIGHT ILLUMINATED. VERIFIED ELEC IND LIGHT ON. PERFORMED FIM PROCEDURE 24 31 00 810 801. CLEARED TRANSIENT FAULTS. BITE TEST GOOD. NO CURRENT FAULTS. GROUND TEST VERIFICATION GOOD. NO HISTORY 2 WEEKS. NOTIFIED SEAMC.SDR ASAA0956694Control Head · malfunctionedIN FLIGHT NR 1 HF RADIO DISPLAYED "FAIL" BOTH CONTROL HEAD WINDOWS DURING ATTEMPTED TX NO SIDE TONE AND A NON COUPLER "BEEP" ON EACH SUBSEQUENT ATTEMPTS. SWITCHED NR 1 HF TO DATA INTERMITTENT DATA RX/TX FOR ENTIRE FLT. HFDR MAINT PAGES SHOWED NORMAL/NORMAL HSDR ASAA0956692Transceiver · malfunctionedUNABLE TO TRANSMIT OR TUNE HF1 OR HF2. ABLE TO MONITOR SELECTED FREQ. REMOVED AND REPLACED HF COUPLER NR 1 REF MM 23-11-61 AND HF RT NR 2 REF 23-11-21 MM. BOTH SYSTEMS OPERATIONAL TEST REF MM 23-11-00. SYSTEMS OPERATIONAL TEST GOOD.SDR ASAA0956655Warning System · malfunctioned"INFO ONLY" ON TAXI OUT FMC DISAGREE ANNUNCIATED ON BOTH INBOARD DU'S. QRH PROCEDURE ACCOMPLISHED AND BOTH FMC'S NORMAL FOR DEPARTURE. PILOTS ACCOMPLISHED QRH PROCEDURE BOTH FMC'S NORMAL FOR DEPARTURE. INFO NOTED.SDR ASAA0956652Vapor Barrier · crackedREFERENCE DEFECT 6190500T (RT WHEEL WELL FOUND 4 INCH CRACK IN VAPOR BARRIER) PERFORM REPAIR OF VAPOR BARRIER. REPAIRED CRACK IN VAPOR BARRIER AT RT WHEEL WELL IAW SRM 51 70 04 REPAIR 10.SDR ASAA0956649Unknown · malfunctionedDESCENT BELOW 10K IN VNAV PATH F/O'S TARGET BUG PROGRAMMED TO 240 KIAS (CORRECT) CAPT'S TARGET BUG DROPPED TO APPROX 205 KIAS BUGS AGREED IN LVL CNG & V/S MODES. PERFORMED AUTOPILOT FLT FAULT REVIEW NO FAILURES LOGGED. ADRU BITE CHECKS NORMAL. SMC HAVE LOGGSDR ASAA0956648Unknown · malfunctionedIN DESCENT THRU 14000 WHILE IN VNAV/LNAV DESCENT AUTO WAS DOING NORMAL TRIMMING BUT MAKING A CLICK CLACK NOISE ON EACH ROTATION DISENGAGES TRIM WORKED SMOOTHLY NO NOISE, NORMAL AT 7000 RE-MESSAGE AUTOPILOT IT TRIMMED SMALL AMOUNTS USED BUT SAME CLICK CLACK NOISDR ASAA0956647Module · intermittentIN CRUISE FLIGHT APU DET INOP CAME ON WITH ASSOCIATED MASTER CAUTION. IT WOULD LIGHT UP EVERY FEW SECONDS FOR A FEW SECONDS GO OUT THEN REPEAT, APU HAS NOT BEEN ON. ACCOMPLISHED APU FIRE DETECTION OPERATIONAL TEST AND ENG/APU FIRE DETECTION CONT MODULE (M279SDR ASAA0956644Indication Sys · malfunctionedGE DIAGNOSTICS REPORTS NR 1 ENGINE TREND DATA SHOWS A SUDDEN DECREASE IN CRUISE DELTA EGT WITH A CORRESPONDING INCREASE IN TAKEOFF HOT DAY MARGIN. INDICATION ERRORS ARE SUSPECT. LONG TERM FAULT 77 10841 TOP RIGHT EGT SIGNAL OUT OF RANGE NR 1 ENG. ACCOMPLISHSDR ASAA0956643Eec · malfunctionedGE DIAGNOSTICS REPORTS NR 1 ENGINE EGT SHIFT. NR 1 ENG EEC VERIFIED BY SEAMC. REMOVED AND REPLACED PER AMM 73 21 60 000 801 AND 73 21 60 400 801 THRU STEP E (F)4 38682. COMPLETED EEC INSTALLATION TEST REF AMM 73 21 60 400 801 STEP F(1 3) 38682. VERIFIED LASDR ASAA0956646Fire Warning · malfunctionedMASTER CAUTION OVERHEAT/DET APU DET INOP APU FAULT LIGHTS FLASHED ON THEN OFF 5 DIFFERENT TIMES ON FOR 1 - 2 SECONDS. PERFORMED ENG/APU FIRE DET CONT MODULE BITE PROCEDURE FIM 26 10 00 810 801 BITE TEST PASSED OK. PERFORMED APU FIRE DET, OP TEST OK PER AMM 2SDR ASAA0956645Monitor · failedGE DIAGNOSTICS REPORTS NR 1 ENGINE NR 4 BEARING LEVEL 2 MESSAGE EXISTS AFTER LAST DATA ERASURE. REMOVED AND REPLACED AVM REF 77 31 03 TO STEP 5 (B)(1). ACCOMPLISHED REMAINING STEPS PER MM 73 31 03 AND 77 31 00 970 805 F00. S/N AC43765 PUT ON SOS. VERIFIED SDR ASAA0956638Warning System · intermittentAFTER TAKEOFF LEFT PACK LIGHT ILLUMINATED AND REMAINED ILLUMINATED AFTER QRH PROCEDURES FOLLOWED. NR 1 CONTROLLER SHOWS TCV THIS PACK FAULT. RESET FAULT. FAULT DID NO RETURN. NO HISTORY 90 DAYS. INTERMITTENT FAULT. OPS CHECK LT PACK GOOD. REF FIM 21 53 SDR ASAA0956641Transceiver · failedPWS FAIL ILLUMINATED ON NAV DISPLAY. DUPLICATED FAULT TWICE. SHOW PWS FAIL WITH WXR FAIL RT. REPLACED WXR TRANSCEIVER. OPS TEST GOOD. REF MM 34 43 41. FIM 34 43 00 810 802.SDR ASAA0956639Warning System · false activationLEFT FWD WINDSHIELD OVERHEAT LIGHT COMES ON DURING PREFLIGHT. CONFIRMED FAULT LT FWD WINDOW OVERHEAT LIGHT ILLUMINATED. PERFORMED FIM 30 41 00 810 801 WHCU BITE CHECK SHOWS NO FAULTS. LT FWD WINDOW HEAT OPS NORMAL. A/C OK FOR SERVICE. SEAMC NOTIFIED.SDR ASAA0956626Actuator · out of rigRIGHT RAM AIR MODULATING SYSTEM INLET DOOR APPEARS OUT OF RIG. DOOR CAN BE PUSHED IN BY HAND. RIGGED & ADJUSTED RT RAM AIR DOOR ACTUATOR SYSTEM. RAM AIR SYSTEM OPS CHECK NORMAL REF 21 51 22.SDR ASAA0956625Warning System · malfunctionedWHILE PERFORMING T/C 08031001 FOUND NR 4 BRG MSG IN AVM: E1 LEVEL 2 NR 1 ENGINE. C/W TASK CARD 78472040 FOUND NO MATERIAL IN SCREENS. PER INSTRUCTION ACCOMPLISHED AVM FAULT HISTORY ERASE REF TASK 77 31 00 970 803 F00. CURRENT BITE AND FAULT HISTORY SHOWS NOSDR ASAA0956617Probe · faultyGE DIAGNOSTICS REPORTS NR 1 ENGINE TREND DATA SHOWS A LARGE FLUCTUATION IN EGT HOT DAY MARGIN AND DELTA EGT ALL OTHER PARAMETERS NORMAL. EGT INDICATION ERRORS ARE SUSPECT. PRE CONNECTOR CLEANING VALUES S1 83 S2 43 S3 49 & S4 101. ACCOMPLISHED CONNECTOR CLEASDR ASAA0956616Valve · leakingNR 1 IDG HAS HISTORY OF FREQUENT SERVICING. FOUND OIL LEAK ON TOP I/B SIDE OF NR 1 IDG PUSH TO VENT VALVE AND SERVICE FILL VALVE. REMOVED & REPLACED IDG PUSH TO VENT VALVE PER AMM TASK 24 11 00 700 804 AND SERVICE FILL VALVE PER CMM 24 11 85. RAN ENGINE. NSDR ASAA0956614Ecu · malfunctionedAPU INOP. VERIFIED APU INOP WITH APU ECU INTERFACE MESSAGE DURING APU BITE. REMOVED AND REPLACED APU ECU PER MM 49 61 12. OPS NORMAL REF SAME. VERIFIED P/N & SOFTWARE NUMBER PER SEAMC. GROUND VERIFICATION CHECKS GOOD. SEAMC NOTIFIED.SDR ASAA0956581Hf Comm · malfunctionedNR 2 HF RADIO INOP. VERIFIED NR 2 HF SHOWED FAIL ON CONTROL HEAD. NO HISTORY PERFORMED NR 2 HF BITE WITH NO FAULTS. VERIFIED COMMUNICATIONS WITH SFO ARINC REF 23 11 0, NO CURRENT FAULTS NOTED.SDR ASAA0956579Warning System · malfunctionedWITH RECALL SELECTED PACK LIGHT ILLUMINATES (L) WITH RESET SELECTED LIGHT EXTINGUISHES. ACCOMPLISHED PACK/ZONE TEMP CONTROLLER BITE TEST ON LEFT CONTROLLER. BITE TEST GREEN PREV FLT RED RAM AIR SENSOR VER, GREEN RESET. SUBSEQUENT BITE TEST ALL GREEN. AIR CSDR ASAA0956578Control Valve · faultyLEFT PACK LIGHT ILLUMINATED AFTER RECALL RESET WITH MASTER CAUTION LIGHT EXTINGUISHED. ACCOMP PACK/ZONE TEMP CONT BITE CHECK RECORDED TCV FAULT LT PACK. REMOVED & REPLACED LT PACK TCV LEAK & OPS NORMAL REF M/M 21 51 10. ALL FAULTS CLEARED BITE CHECK GOOD RESDR ASAA0956577Acm · failedLEFT PACK LIGHT ILLUMINATED AFTER LANDING DURING TAXI. LEFT PACK TEMPERATURE HIGH 85'. GROUND RAN LT PACK VERIFIED NO COOLING AIR COMING FROM LT PACK HEAT EXCHANGER. FAILED LT ACM. NEW ACM P/N VERIFIED SEAMC 2206400 2 IPC 21 51 04 01 ITEM 25J. REMOVED AND
Back to Boeing 737-890