Boeing 737-8H4
Service difficulty reports · 24,314
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378H4' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2022060909616Threshold Web · corrodedAFT CARGO BAY SUBTHRESHOLD WEB HAS CORROSION BS 787+18 TO BS 807+2 RBL 26 WL 157 / [01] EVALUATED CORROSION AT ALL LOCATIONS ON SUBTHRESHOLD WEB; FOUND DEEPEST LOCATION TO BE AT BS 807+1 RBL 26 WL 157; FOUND 0.015 REMOVED FROM ORIG 0.045 FOUND TO BE OUT OF LIMSDR SWAA2022060909617Splice Strap · corrodedAFT CARGO BAY FLOOR SPLICE STRAP HAS CORROSION BS 767+5 RBL 13 WL 156 / [01] EVALUATED FLOOR SPLICE STRAP BS 767+5 RBL 13 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-0-0G-0;[02] VERIFIED CORRECTIVE ACTIOSDR SWAA2022052409880Pin · shearedFWD ENTRY DOOR WILL NOT OPEN / [01] FOUND BROKEN SCREW ON THE UPPER GUIDE ARM PIN. R/R PIN AND SCREW PER AMM 52-11-21. AND OPS CHECK OF FWD ENTRY DOOR IS O.KSDR SWAA2022052409970Handle · loosePLASTIC HANDLE ON FWD GALLEY SERVICE DOOR CAME LOOSE / [01] REPLACED PLASTIC HANDLE ON FWD GALLEY SERVICE DOOR PER M/M 25-21-31. CHECKS GOOD.SDR SWAA2022060909199Shield · corrodedAFT CARGO BAY SHIELD HAS CORROSION BS 767+5 RBL 23 WL 156 / [01] EVALUATED CORROSION ON SHIELD BS 767+5 RBL 23 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION ENTRY 1.SDR SWAA2022060909200Angle · corrodedAFT CARGO BAY INTERCOSTAL ANGLE BELOW SHIELD HAS CORROSION BS 767+5 RBL 23 WL 156 / [01] EVALUATED CORROSION ON ANGLE BS 767+5 RBL 23 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORSDR SWAA2022060909201Shield · corrodedAFT CARGO BAY SHIELD HAS CORROSION BS 847+10 RBL 23 WL 164 / [01] EVALUATED CORROSION ON SHIELD BS 847+10 RBL 23 WL 164; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION ENTRY SDR SWAA2022060909202Sidewall Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT HAS CORROSION BS 727G+13 TO BS 767+10 LBL 21 WL 156 / FOUND DEEPEST LOCATION TO BE AT BS 727J+10 LBL 21 WL 156; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 USING DIAL DEPTH GAUGE ATS 2678 DUE 4/2023;[02] CORRECTION TSDR SWAA2022060909203Sidewall Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT HAS CORROSION BS 727F+9 TO 767 RBL 21 WL 156 / [01] EVALUATED CORROSION AT ALL LOCATIONS ON FLOOR TO SIDEWALL SUPPORT IN NUMEROUS 1'X1' AREAS; FOUND DEEPEST LOCATION TO BE AT BS 727I+10 RBL 21 WL 156; FOUND 0.015 REMOVEDSDR SWAA2022060609198Support · corrodedFORWARD CARGO BAY AFT CENTER BULKHEAD SUPPORT HAS CORROSION BS 500I LBL 23 TO RBL 23 WL 156 / EVALUATED CORROSION AT ALL LOCATIONS IN NUMEROUS 1'X1' AREAS; FOUND THE DEEPEST LOCATION TO BE AT BS 500I RBL 22 WL 156; FOUND 0.021 REMOVED FROM ORIGINAL 0.071; FOUSDR SWAA2022060609197Support · corrodedFORWARD CARGO BAY FLOOR TO SIDEWALL SUPPORT HAS CORROSION BS 500B+10 TO 500I RBL 23 WL 156 / EVALUATED CORROSION AT ALL LOCATIONS ON FLOOR TO SIDEWALL SUPPORT IN NUMEROUS 1'X1' LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500D+10 RBL 23 WL 156; FOUND TO BE OUSDR SWAA2022052609490Angle · corrodedFORWARD CARGO AFT BULKHEAD LOWER ANGLE CORRODED UPPER SURFACE AROUND FASTENER HOLES RBL 26 TO LBL 26. FAULT REWRITTEN FROM FAULT # TTG8Q00C5L4K TO ANSWER CORROSION QUESTIONS. / [01] FAULT REWRITTEN FROM FAULT # TTG8Q00C5L4K TO ANSWER CORROSION QUESTIONS. INSTASDR SWAA2022052310321Flashlight · failedAFT RIGHT FA JUMPSEAT EMERGENCY FLASHLIGHT SHOWING RED LIGHT / [01] R&R AFT RH F/A JUMPSEAT FLASHLIGHT BATTERY REF AMM 25-64-00SDR SWAA2022052309683Flashlight · failedAFT RIGHT FA JUMPSEAT EMERGENCY FLASHLIGHT SHOWING RED LIGHT / [01] R&R AFT RH F/A JUMPSEAT FLASHLIGHT BATTERY REF AMM 25-64-00SDR SWAA2022052310334Girt Bar · out of adjustF/A REPORTS FWD ENTRY DOOR GIRT BAR DIFFICULT TO REMOVE/INSTALL / [01] PERFORMED FWD ENTRY DOOR GIRT BAR ACTIVATION AND DEACTIVATION PER AMM 25-66-00 OPS CHECK GOODSDR SWAA2022051909253Battery Pack · inoperativeLH OVERWING EXIT EMERGENCY EXIT SIGN & FWD & AFT EXIT LIGHT MODULES LIGHTS INOP / [01] REPLACED BATTERY PACK IN POWER SUPPLY M1694 FOR LH OVERWING EXIT LIGHTS PER AMM 33-51-06. OPS CHECK GOOD.SDR SWAA2022061308718Angle · crackedAFT CARGO L/H SIDE; ANGLE CRACKED STATION 867 LOWER END OF STANCHION(SUPPORT ANGLE) REFERENCE CARD [TTG8Q00CF9MP] / [01] REPLACED ANGLE PER SRM 51-40-02.;[02] PART WAS INCORRECTLY ISSUED AGAINST NON-ROUTINE CARD TTG8Q00F9MP AND SHOULD HAVE BEEN ISSUED AGAINST SDR SWAA2022061309119Flap · delaminatedR/H WING O/B AFT FLAP LOWER SURFACE I/B CORNER HAS AREA OF DELAM / [01] BOND TEST IAW B737 NDT PART 4; 51-00-05. DISBONDED AREA MARKED IN BLACK. TOOL#40082; DUE 11OCT22;[02] EVALUATED AND FOUND DELAMANATION AS MARKED. FOUND TO BE REPAIRABLE IAW SRM 57-53-01-2RSDR SWAA2022060609191Shield · corrodedAFT CARGO BAY SHIELD HAS CORROSION BS 767+10 RBL 23 WL 157 / [01] EVALUATED CORROSION ON SHIELD BS 767+10 RBL 23 WL 157; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTIONS STEP SDR SWAA2022060609192Intercostal · corrodedAFT CARGO BAY INTERCOSTAL ANGLE BELOW SHIELD HAS CORROSION BS 767+10 RBL 23 WL 157 / [01] EVALUATED CORROSION ON ANGLE BS 767+10 RBL 23 WL 157; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CSDR SWAA2022060609193Shield · corrodedAFT CARGO BAY SHIELD HAS CORROSION BS 847+16 RBL 23 WL 164 / [01] EVALUATED CORROSION ON SHIELD BS 847+16 RBL 23 WL 164; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTIONS STEP SDR SWAA2022060609194Splice Strap · corrodedAFT CARGO BAY FLOOR SPLICE STRAP HAS CORROSION BS 767+5 RBL 3 WL 156 / [01] EVALUATED CORROSION ON FLOOR SPLICE STRAP BS 767+5 RBL 3 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRSDR SWAA2022060609039Panel · debondedPANEL 195BL OUTER SKIN IS DISBONDED NEAR AFT EDGE. ( MARKED) / [01] IDENTIFIED PANEL 195BL IAW SRM 53-40-70-0I-1 FIGURE 2; SHEET 1; TABLE 2; ITEM 3.<BR><BR>DAMAGE NOTED IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-40-70-1A-1 PAR 4A(6).<BR><BR>REPAIR TO BE ACCOSDR SWAA2022060609195Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT HAS CORROSION BS 727G+16 TO 787+6 LBL 21 WL 156 / EVALUATED CORROSION AT ALL LOCATIONS ON FLOOR TO SIDEWALL SUPPORT; FOUND DEEPEST LOCATION TO BE AT BS 727I+10 LBL 21 WL 156; FOUND 0.015 REMOVED FROM ORIG 0.040 IN NUMERSDR SWAA2022060609196Support · corrodedAFT CARGO BAY FLOOR TO SIDEWALL SUPPORT HAS CORROSION BS 727F TO BS 767 RBL 21 WL 156 / EVALUATED CORROSION AT ALL LOCATIONS ON FLOOR TO SIDEWALL SUPPORT; FOUND DEEPEST LOCATION TO BE AT BS 747+10 RBL 21 WL 156; FOUND 0.015 REMOVED FROM ORIG 0.040 IN NUMEROUS SDR SWAA2022052409415Battery Pack · inoperativeALL EMERGENCY LIGHTS ARE INOP AT BATTERY PACK M1695 R/H STA 565 WL 213 RBL 68 / [01] REMPOVED AND REPLACED AND OPS CHECKED BATTERY PACK M1695 R/H STA 565 WL213 RBL 68 OPS CHECK GOOD.<BR>WORK PERFORMED BY DAINEL WHITE EMP # 28971;[02] VERIFIED STEP 1<BR>AUDIT CSDR SWAA2022052409416Battery Pack · inoperativeEMERGENCY LIGHTS ON BATTERY PACK M1676 ARE ALL INOP / [01] REMOVED AND REPLACED BATTERY AT M1676 R/H IAW AMM 33-51-06-960-805 OP'S CHECKED OK;[02] VERIFIED STEP 1<BR>AUDIT CWSDR SWAA2022052410949Battery Pack · inoperativeALL EMERGENCY LIGHTS ARE INOP AT BATTERY PACK M1695 R/H STA 565 WL 213 RBL 68 / [01] REMPOVED AND REPLACED AND OPS CHECKED BATTERY PACK M1695 R/H STA 565 WL213 RBL 68 OPS CHECK GOOD.<BR>WORK PERFORMED BY DAINEL WHITE EMP # 28971;[02] VERIFIED STEP 1<BR>AUDIT CSDR SWAA2022051909074Light · inoperativeCAPTAINS SIDEWALL LIGHTS ROW 6-10 INOP CAPTAINS SIDEWALL LIGHTS ROW 6-10 INOP *WORK IN CONJUNCTION WITH CONCURRENT MEL FOR ROWS 22-28* / [01] R&R SEAT 6A LED LIGHT ASSEMBLY PER AMM 33-21-00. OPS CHECKS GOOD.SDR SWAA2022051908682Frame · crackedDURING WALK AROUND INSPECTION; FOUND A CRACK LOCATED ON CENTRAL BOTTOM SIDE OF THE GPU DOOR / [01] REMOVED DAMAGED SECTION OF ELECTRICAL GROUND POWER RECEPTACLE SURROUND PER SRM 53-10-15-2R-4 REPAIR 4.;[02] ACCOMPLISHED AN HIGH FREQUENCY EDDY CURRENT (HFEC) INSDR SWAA2022061308506Shield · corrodedFWD CARGO COMPARTMENT FLOOR AREA STA 500 TO STA 500A; RBL 24; WL 156; SHIELD IS CORRODED. A177-009 / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15;[02] EVALUATED ALLOWABLE LIMITS. 040 ORIGINAL 'T' .031 REMAINING .009 LOSS; FOUND OUT OF LIMITSSDR SWAA2022060908521Angle · corrodedFWD CARGO COMPARTMENT FLOOR AREA STA 500C TO STA 500D; LBL 24; WL 156; Z-ANGLE IS CORRODED. A177-014 / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15;[02] EVALUATED ALLOWABLE LIMITS ..040 ORIGINAL 'T' .030 REMAINING .010 LOSS FOUND OUT OF LIMISDR SWAA2022060908522Angle · corrodedFWD CARGO COMPARTMENT FLOOR AREA STA 500D TO STA 500E; RBL 24 WL 156; Z-ANGLE IS CORRODED. A177-015 / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM15;[02] EVALUATED ALLOWABLE LIMITS; .040 ORIGINAL 'T' .032 REMAINING .008 LOSS FOUND OUT OF LIMITSSDR SWAA2022060908513Angle · corrodedFWD CARGO COMPARTMENT FLOOR AREA STA 500E TO STA 500F; RBL 24 WL 156; Z-ANGLE IS CORRODED. A177-017 / [01] EVALUATED ALLOWABLE LIMITS OF CORROSION (Z ANGLE) 100% MATERIAL LOSS FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2;[02] VERIFIED STEPS 1 AND 2 ARE COMPLETE;[SDR SWAA2022060908516Angle · corrodedFWD CARGO COMPARTMENT FLOOR AREA STA 500H TO STA 500I; RBL 24 WL 156; Z-ANGLE IS CORRODED. A177-022 / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15;[02] EVALUATED ALLOWABLE LIMITS .040 ORIGINAL 'T' .023 REMAINING.017 LOSS FOUND OUT OF LIMITS SDR SWAA2022060908970Attach Angle · crackedA125-02 - AFT CARGO BAY - BS867; WL156; LBL11 - CRACKED ATTACH ANGLE @ WASTE TANK CLOSE-OUT BULKHEAD VERTICAL PILAR / [01] REMOVED ATTACH ANGLE AT AFT CARGO BAY WASTE TANK CLOSE OUT BULKHEAD IAW SRM 51-40-02;[02] VERIFIED NEW ANGLE P/N 149A8109U114 A TAG A1268SDR SWAA2022060908975Shield · corrodedA125-03 - AFT CARGO BAY - BS767-787; WL156; RBL24 - DOOR FWD SHIELD CORRODED @ FASTENER HOLES / [01] REMOVED CORROSION IAW SRM 51-10-02 10X MAGNIFY ORIGINAL THICKNESS .050 .020 MATERIAL REMOVED .030 MATERIAL REMAINS FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1SDR SWAA2022060908520Angle · corrodedFWD CARGO COMPARTMENT FLOOR AREA STA 500C TO STA 500D; RBL 24 WL 156; Z-ANGLE IS CORRODED. A177-013 / [01] REMOVED CORROSION ON Z ANGLE IAW SRM 51-10-02-0G-0 ITEM 15;[02] EVALUATED ALLOWABLE LIMITS; .040 ORIGINAL 'T' .028 REMAINING .012 LOSS ;FOUND OUT OF LIMISDR SWAA2022060808732Tie Down · corrodedDOT#18-186 AFT PIT FWD AND AFT DOOR NET TIE DOWNS CORRODED / [01] REMOVED 2 EA. SCUFF PLATES. EVALUATED CORROSION; 100% MATERIAL LOSS. OUT OF LIMITS IAW B737 SRM 53-00-53-1A-2; FIGURE 103.;[02] NEW PLATES VERIFIED AN P/N 453A2611-2 A TAG #A106969; AND P/N 453ASDR SWAA2022052408645Battery Pack · inoperativeMID/AFT CABIN LEFT SIDE EMERGENCY LIGHTS ARE OUT / [01] SIGNING FOR DANIEL WHITE AAR EMPLOYEE #28971 REPLACED EMERGENCY BATTERY PACK AT L/H STA 727C OPS CHECK GOOD IAW AMM 33-51-06-960-805;[02] VERIFED STEP 1<BR>OK TO INSTALL DADDO PANEL;[03] SIGNING FOR DANIESDR SWAA2022052408646Battery · inoperativeMID/AFT CABIN RIGHT SIDE EMERGENCY LIGHTS ARE OUT / [01] REMOVED AND REPLACED AND OP'S CHECKED MID /AFT CABIN RIGHT SIDE BATTERY M1671 IAW AMM 33-51-06-960-805 OP'S CHECK GOOD.;[02] ALL WORK COMPLETED;[03] VERIFED STEP 1<BR>OK TO INSTALL DADDO PANEL;[04] CLOSESDR SWAA2022051908913Light · out of positionFORWARD DOOR EMERGENCY EXIT LIGHT COVER IS LOOSE / [01] REPLACED LIGHT ASSY PER M/M 33-51-01SDR SWAA2022060808508Floor Panel · corrodedAFT CARGO FLOOR BOARD 140 EF CORRODEDD ALONG EDGE A225-001 / [01] CORROSION REMOVED FROM AREA OUT OF LIMITS DUE TO AREA IS MORE THAN 20 INCHES PER SRM 53-00-53-1A-1 FIGURE 102;[02] VERIFIED STEP 1;[03] NEW MATERIAL 0.071' 2024 T3 IAW AMM 25-52-01-201-803 1-C ASDR SWAA2022060808501Floor Panel · corrodedAFT CARGO FLOOR BOARD 140 AF CORRODEDD ALONG EDGE A225-002 / [01] EVALUATED CORROSION ON FLOOR PANEL 140AF FOUND TOTAL ACUMULATED DAMAGE TO EXCEED 20 INCHES IN LENGTH FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102. MEASURED WITH STEEL RULE;[02] MATERISDR SWAA2022060808509Floor Panel · corrodedAFT CARGO FLOOR BOARD 140 CF CORRODEDD ALONG EDGE A225-003 / [01] EVALUATED CORROSION ON FLOOR PANEL 140CF FOUND TOTAL ACUMULATED DAMAGE TO EXCEED 20 INCHES IN LENGTH FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102. MEASURED WITH STEEL RULE;[02] VERIFYSDR SWAA2022060808510Floor Panel · corrodedAFT CARGO FLOOR BOARD 140 BF CORRODEDD ALONG EDGE A225-004 / [01] AFT CARGO FLOOR BOARD 140BF CORROSION ALONG EDGE EXCEEDS THE 20' MAX AND 10' CONTINUOUS LIMIT. FLOOR BOARD FOUND OUT OF LIMITS IAW B-737 AMM 53-00-53-1A-1.;[02] NEW MATERIAL VERIFIED AS 0.071' 2SDR SWAA2022060808511Floor Panel · corrodedAFT CARGO FLOOR BOARD 140 DF CORRODEDD ALONG EDGE A225-005 / [01] EVALUATED CORROSION ON FLOOR PANEL 140AF FOUND TOTAL ACUMULATED DAMAGE TO EXCEED 20 INCHES IN LENGTH FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 FIG 102. MEASURED WITH STEEL RULE;[02] VERIFISDR SWAA2022060708261Angle · crackedLH A/C BAY STA 663 LBL10 LOWER CENTER TANK ATTACH ANGLE IS CRACKED. A177-003 / INSTALLED EWIZ PROTECTION IAW AMM 20-60-07-913-801.[13] LOCATED; DRILLED AND TRIMMED TO FINAL SIZE -1 INBOARD REPLACEMENT SECTION; -2 SPLICE SECTION; AND -1 OUTBOARD REPLACEMENT SECSDR SWAA2022052408427Ctot Panel · crackedELECTRICAL DOOR CUTOUT LOWER LATCH PAD AREA HAS CRACK AT CUTOUT / REMOVED THE INITIAL RUBBING BLOCK/SHIM AND TRIMMED OUT DAMAGED AREA OF EGPR DOUBLER ZONE 2 IAW SRM 53-10-15-2R-4; VERIFIED MATERIAL FOR -2 DOUBLER PN: 2024-T3-050 A-TAG: A2062 AND -3 FILLER PN: SDR SWAA2022051908193Lens · missingMID CABIN OVERHEAD EMERGENCY EXIT PLASTIC LENS MISSING [FACING FORWARD] / [01] SNAPPED EMERGENCY EXIT LENS BACK ON PER AMM 33-51-01
Back to Boeing 737-8H4