SDR SWAA2022061508134Attach Angle · crackedR/H BS663 UPPER ATTACH ANGLE CRACKED ON VAPOR BARRIER RBL8 WL167.68 / [01] VALIDATED APPLICABILITY OF SRM 57-10-10-2R-5 AND UPDATED MEASUREMENT TABLE;[02] REMOVED DAMAGED SECTION OF RH BS663 UPPER ATTACH ANGLE RBL8-RBL20 WL167.68 IAW SRM 57-10-10-2R-5.;[03] PESDR SWAA2022061308260Floor Panel · corrodedFWD CARGO FLOOR PANEL 120 AF ; CORRODED ALONG EDGE A225-013 / [01] MATERIAL I.D IS 2024 T3 0.071;[02] CHECKED LIMITS. OUT OF LIMITS PER 53-00-53-1A-1 FIGURE 102;[03] VERIFIED STEPS 1 AND 2;[04] FABRICATED NEW FLOORBOARD FROM 2024 T3 0.071;[05] VERIFIED STEP 4;SDR SWAA2022061308254Angle · crackedDOT 24-003. RIGHT HAND PACK BAY; HORIZONTAL ANGLE COMMON TO LOWER SIDE OF CENTER FUEL TANK AT STATION 663 RBL 10 IS CRACKED 3RD FASTENER OUTBOARD OF KEEL BEAM VERTICAL ANGLE. / VERIFY REPAIR PARTS FORMED AND HEAT TREATED ON BACKSHOP W/O # 43699-5100-0001 ( -1 SDR SWAA2022060808262Floor Panel · corrodedFWD CARGO FLOOR PANEL 120 BF ; CORRODED ALONG EDGE A225-014 / [01] CORROSION ALONG FLOOR PANEL EDGE EXCEEDS THE 20' MAX LIMIT. PANEL 120BF FOUND OUT OF LIMITS IAW B-737 AMM 53-00-53-1A-1.;[02] MATERIAL VERIFIED AS 0.071' 2024-T3 IAW B-737 AMM 25-52-01-201-801.SDR SWAA2022060808257Floor Panel · corrodedFWD CARGO FLOOR PANEL 120 CF ; CORRODED ALONG EDGE A225-015 / [01] EVALUATED CORROSION DAMAGE ALONG EDGE OF PNL 120CF; FOUND TO BE OUT OF LIMITS DUE TO TOTAL ACCUMULATED DAMAGE BEING GREATER THAN THE 20' MAX ALLOWED; IAW SRM 53-00-53-1A-1;[02] VERIFIED MATERIASDR SWAA2022060808263Floor Panel · corrodedFWD CARGO FLOOR PANEL 120 DF ; CORRODED ALONG EDGE A225-016 / [01] EVALUATED ALLOWABLE LIMITS CORROSION IS MORE 20 INCH MAXIMUM ALLOWED FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-1;[02] VERIFIED. MATERIAL ID FOR FLOOR PANEL IS 2025 T3 .071 TAG# A120976 IAW AMM 25SDR SWAA2022060808065Tail Cone · cracked#2 FLAP TRACK AFT FAIRING TAIL CONE 543EB CRACKED ON THE LOWER SIDE (MARKED) / [01] EVALUATED AND FOUND CRACK ON LWR SIDE AS MARKED. NO DAMAGE TO CORE. FOUND TO BE REPAIRABLE IAW SRM 57-53-70-2R-1 TABLE 201 AND SRM 51-70-05-2R-1 PRE-PREG.<BR><BR>CLEANED AND PRSDR SWAA2022060808341Battery Pack · inoperativeEMERGENCY LIGHTS ASSOCIATED WITH BATTERY PACK M1672 ARE INOPERATIVE. REMOVED AND REPLACED BATTERY PACK M1672 IAW AMM 33-51-06-960-805 PARA 4. E.(1); (2); (3); (E) (4) AND (5). TESTED M1672 EMERGENCY LIGHTS WAS ACCOMPLISHED ON DEFECT TTG8Q00CLJYZ; NO DEFECTSSDR SWAA2022060808342Light · inoperativeEMERGENCY EXIT LIGHTS ASSOCIATED WITH M1673 ARE INOP. REMOVED AND REPLACED EMERGENCY EXIT LIGHT BATTERY PACK AND PERFORMED A GOOD TEST IAW AMM 33-51-06-960-805.SDR SWAA2022051908050Battery · inoperative1 FLASHLIGHT INOP IN AFT GALLEY / [01] R&R FLASHLIGHT BATTERY IN THE AFT GALLEY PER AMM 25-64-00<BR>OPS CHECK OKSDR SWAA2022051908406Bracket · brokenAFT SERVICE DOOR GIRT BAR BRACKET BROKEN / [01] GIRT BAR BRACKET ISN'T BROKEN; IT NEEDED ADJUSTMENT TO HOLD GIRT BAR TO MAKE SURE THAT THE BRACKETS OPERATE CORRECTLY PER MM 25-66-02 STEP 3.E.SDR SWAA2022051908053Battery Pack · inoperativeFWD ENTRY DOOR EMERGENCY LIGHTS INOP. / [01] R&R'D BATTERY PACK; OP CK GOOD IAW AMM 33-51-06.SDR SWAA2022051908054Battery Pack · inoperativeL/H OVERWING EXITS EMERGENCY LIGHTS INOP. / [01] R&R'D BATTERY PACK; OP CK GOOD IAW AMM 33-51-06.SDR SWAA2022051808117Battery Pack · inoperative9 EA EMERGENCY LIGHTS ARE INOP. / [01] AFTER FURTHER INVESTIGATION; FOUND THAT INOP LIGHTS ARE ASSOCIATED WITH EMERGENCY EXIT LIGHTS BATTERY PACKS M2335 AND M1672.REMOVED AND REPLACED EMERGENCY EXIT LIGHT POWER SUPPLIES M2335 AND M1672. PERFORMED GOOD INSTALLASDR SWAA2022051808921Battery Pack · inoperative9 EA EMERGENCY LIGHTS ARE INOP. AFTER FURTHER INVESTIGATION; FOUND THAT INOP LIGHTS ARE ASSOCIATED WITH EMERGENCY EXIT LIGHTS BATTERY PACKS M2335 AND M1672.REMOVED AND REPLACED EMERGENCY EXIT LIGHT POWER SUPPLIES M2335 AND M1672. PERFORMED GOOD INSTALLATION TESDR SWAA2022051808432Flashlight · failedBOTH FWD F/A FLASHLIGHTS WILL NOT TEST. / [01] R&R?ED BOTH FWD FA FLASHLIGHT BATTERIES IN REF. TO AMM 25-64-00. OPS C/K GOOD AT THIS TIME.SDR SWAA2022051808922Flashlight · failedBOTH FWD F/A FLASHLIGHTS WILL NOT TEST. / [01] R&R?ED BOTH FWD FA FLASHLIGHT BATTERIES IN REF. TO AMM 25-64-00. OPS C/K GOOD AT THIS TIME.SDR SWAA2022051808102Flashlight · failedFWD FA FLASHLIGHT FWD FLT ATT FLASHLIGHT (LEFT) WOULD NOT TEST / [01] R/R FLIGHT ATT FWD FLASHLIGHT BATTERY PER AMM 25-64-00SDR SWAA2022051808199Flashlight · inoperativeAFT FLASHLIGHT HAS NO CHARGE. / [01] OK TO CONTINUE PER MEL 25-12-01. C/W SP-1B; AUTH# 66372.;[02] REPLACED AFT LEFT HAND HANDSET PER M/M 25-64-00. OPS CHECKS OK;[03] CORRECTION: REPLACED AFT RIGHT FLIGHT ATTENDANT FLASHLIGHT PER M/M 25-64-00. OPS CHECKS OKSDR SWAA2022051808398Flashlight · inoperativeFWD ERER FLASHLIGHT BATTERY INOP / [01] INSTALLED FWD EMER FLIGHTLIGHT BATTERY + SEALS PER AMM 25-24-03SDR SWAA2022052607869Battery Pack · inoperativeEMERGENCY LIGHTS ARE INOP AT R/H OVERHEAD BIN; SEAT 6; 10; 14; 18 AND 21 FED. EMERGENCY LIGHTS ARE INOP AT R/H OVERHEAD BIN SEAT 6 10 14 18 AND 21 FED. / [01] R/R DIMMING LIGHT RELAY PER WDM 33-29-11;[02] CORRECTIVE ACTION ENTERED IN ERROR.;[03] R/R EMERGENCY SDR SWAA2022051708027Battery · failedFWD F/A J/S OB FLASHLIGHT NOT TESTING / [01] R&R FLASHLIGHT BATTERY; CKS GOD REF AMM 33-55-00SDR SWAA2022051807806Light · inoperativeLEFT SIDE FIRST PHOTOLUMINECENT LIGHT STRIP OUT (ROW 1 ) RIGHT SIDE 2ND LIGHT STRIP OUT (ROW 2) / [01] R/R PHOTOLUMINESCENT LIGTH SRTIPS IAW AMM 33-51-15SDR SWAA2022051807815Light · inoperativeRT FWD EMERGENCY LIGHT OUTSIDE LIGHT INOP / [01] RELAMPED IAW AMM 33-51-04. OPS CHECK GOODSDR SWAA2022051807657Light · inoperativeEMERGENCY EXIT LIGHTS HAVE BURNT OUT SEGMENTS AT LEFT OEW AND FED / [01] RELAMPED LEFT OVERWING EXIT AND FORWARD ENTRY DOOR SIGN SEGMENTS AND TESTED NEW LAMPS PER AMM 33-51-01-960-801;[02] VERIFIED CORRECTIVE ACTION #1.SDR SWAA2022051807927Sign · missingEMERGENCY EXIT SIGN MISSING ON CENTER AISLE / [01] REPLACED EMERGENCY EXIT SIGN CENTER AISLE MID CABIN REF AMM 33-51-01. OPS CHECK GOODSDR SWAA2022061310157Angle · damagedTOOLING MARK ON L/H TRANSITION ANGLE AT APPROX. STA 452 / [01] DAMAGE FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] CUT AND REMOVED SECTION OF LEFT HAND TRANSITION ANGLE AT FORWARD CARGO; STATION 440+10 TO 500E+10 I/A/W SRM 53-00-53-2R-5.;[03] FABRICATSDR SWAA2022061307681Transition Panel · corrodedAFT CARGO COMPARTMENT; BS 727C+12 THROUGH 727C+16; RBL 21; 2EA FASTENER HOLES ON R/H TRANSITION ANGLE HAVE LIGHT SURFACE CORROSION. / [01] REMOVED CORROSION; MATERIAL LOSS WAS .002IN AND REMAINING MATERIAL IS .032IN. FOUND TO BE WITHIN LIMITS PER SRM 53-00-53-SDR SWAA2022061307682Angle · corrodedAFT CARGO R/H TRANSITION ANGLE STA. 723-767 SHOWS SIGNS OF SURFACE CORROSION. / [01] REMOVED CORROSION AND WAS FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. REMOVED .010IN OF MATERIAL FROM .040IN WITH REMAINING .030IN;[02] REMOVED R/H TRANSITION ANGLE FROM SDR SWAA2022061307467Door Sill · corrodedFWD CARGO HAS HEAVY CORROSION AROUND FASTENER HOLES ON ENTRY DOOR SILL PLATE / [01] FWD CARGO ENTRY DOOR SILL PLATE FOUND TO BE OUT OF LIMITS PER 53-30-15-1A-1;[02] FWD CARGO ENTRY DOOR SILL PLATE FOUND TO BE OUT OF LIMITS PER SRM 53-30-15-1A-1;[03] ADDED TYPESDR SWAA2022061307676Transition Panel · corrodedAFT CARGO L/H TRANSITION ANGLE STA 768-794 SHOWS SIGNS OF SURFACE CORROSION / [01] FOUND TO OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] REMOVED LOCATED AND DRILLED TRANSITION ANGLE PER AMM 51-40-02;[03] FABRICATED AFT CARGO; LEFT HAND TRANSITION ANGLE FROM 727I-SDR SWAA2022061307690Threshold · corrodedFWD SERVICE DOOR CUTOUT STRUCTURE UNDER THRESHOLD CORRODED. / [01] BLENDED CORROSION PER SRM 51-10-02. DAMAGE REMOVAL FOUND TO OUT OF LIMITS PER SRM 53-10-15.;[02] REMOVED AND REPLACED FWD SERVICE DOOR THRESHOLD ANGLE IAW SRM 51-40-02.;[03] COMPLETED CORROSIONSDR SWAA2022061307457Angle · corrodedFWD CARGO HAS LIGHT CORROSION AROUND FASTENER HOLES ON R/H TRANSITION ANGLE AT APPROX. STA 500D-500E / [01] REMOVED CORROSION TREATED PRIMED PER SRM 53-00-53-1A-2 ORIGINAL THICKNESS .040 REMAINING .037 REMOVED IN LIMITSSDR SWAA2022052607867Floor Panel · corrodedPANEL 120AF SHOWS EVIDENCE OF CORROSION. / [01] R&R CARGO FLOOR PANEL 120AF PER AMM 25-52-10SDR SWAA2022052607707Floor Panel · corrodedPANEL 120CF SHOWS EVIDENCE OF CORROSION. / [01] R&R CARGO FLOOR PANEL 120CF PER AMM 25-52-10SDR SWAA2022052607866Floor Panel · corrodedPANEL 120BF SHOWS EVIDENCE OF CORROSION. / [01] R&R CARGO FLOOR PANEL 120BF PER AMM 25-52-10SDR SWAA2022052607868Floor Panel · corrodedPANEL 120DF SHOWS EVIDENCE OF CORROSION. / [01] R&R CARGO FLOOR PANEL 120DF PER AMM 25-52-10;[02] R&R CARGO FLOOR PANEL 120DF PER AMM 25-52-10. C/WSDR SWAA2022051307354Lamp · inoperativeL1 EXTERIOR EMERGENCY LIGHT INOP. / [01] RELAMPED L1 EXTERIOR EMERGENCY LIGHT PER AMM 33-51-04. OPS CHECK GOOD AT THIS TIME.SDR SWAA2022061307184Floor Panel · corrodedFLOORBOARD 221AF DIRTY AND HAS MULTIPLE INSERTS CORRODED; AND/OR PULLED- MARKED / [01] INSTALLED NEW FLOOR PANEL 221AF PER AMM 53-21-00.;[02] INSPECTED WORK ACCOMPLISHED.SDR SWAA2022061307186Floor Panel · corrodedFLOORBOARD 221BF DIRTY; HAS SLIGHT SURFACE DAMAGE; AND HAS MULTIPLE INSERTS CORRODED; AND/OR PULLED- MARKED / [01] INSTALLED NEW FLOOR PANEL 221BF PER AMM 53-21-00 ON CARD 642CLOSE-PANEL 221BF (PANEL 221BF PANEL ASSEMBLY - LH PASSENGER CABIN FLOOR ACCESS - (WESDR SWAA2022061307187Floor Panel · corrodedFLOORBOARD 221DF DIRTY; AND HAS MULTIPLE INSERTS CORRODED; AND/OR PULLED- MARKED / [01] INSTALLED NEW FLOOR PANEL PER AMM 53-21-00 221DF ON CARD 638 CLOSE-PANEL 221DF (PANEL 221DF PANEL ASSEMBLY - LH PASSENGER CABIN FLOOR ACCESS - (WET AREA) STA 300) [TTG8Q00BSDR SWAA2022061307188Floor Panel · corrodedFLOORBOARD 221CF DIRTY; AND HAS MULTIPLE INSERTS CORRODED; AND/OR PULLED- MARKED / [01] INSTALLED NEW FLOOR PANEL 221CF PER AMM 53-21-00.;[02] INSPECTED WORK ACCOMPLISHED.SDR SWAA2022061307189Floor Panel · corrodedFLOORBOARD 222BF DIRTY; AND HAS MULTIPLE INSERTS CORRODED; AND/OR PULLED- MARKED / [01] INSTALLED NEW FLOOR PANEL 222BF PER AMM 53-21-00 ON CARD 628 C CLOSE-PANEL 222BF (PANEL 222BF PANEL ASSEMBLY - LH PASSENGER CABIN FLOOR ACCESS - (WET AREA) STA 300) [TTG8Q0SDR SWAA2022061307190Floor Panel · corrodedFLOORBOARD 222DF DIRTY; HAS SLIGHT EDGE DAMAGE; AND HAS MULTIPLE INSERTS CORRODED; AND/OR PULLED- MARKED / [01] INSTALLED NEW PANEL ON CARD 624 CLOSE-PANEL 222DF [TTG8Q00BAUM0];[02] C/WSDR SWAA2022060807445Panel · damagedPANEL 242D PANEL ASSEMBLY - PASSENGER CABIN FLOOR HAS FIBERS MISSING. / [01] REMOVED AND REPLACED FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTED AS REQUIREDSDR SWAA2022060807422Floor Panel · missingPANEL 241XF PANEL ASSEMBLY - PASSENGER CABIN FLOOR HAS FIBERS MISSING. / [01] REMOVED AND REPLACED FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTED AS REQUIREDSDR SWAA2022060807446Floor Panel · damagedPANEL 241UF PANEL ASSEMBLY - PASSENGER CABIN FLOOR HAS FIBERS MISSING. / [01] REMOVED AND REPLACED FLOOR PANEL IAW AMM 53-21-00;[02] C/W OK TO CLOSE INSPECTION;[03] C/W INSPECTIONSDR SWAA2022060807425Floor Panel · damagedPANEL 241F PANEL ASSEMBLY - PASSENGER CABIN FLOOR HAS FIBERS MISSING. / [01] REMOVED AND REPLACED FLOOR BOARD IAW AMM 53-21-00;[02] C/W INSPECTION;[03] C/W INSPECTIONSDR SWAA2022060807448Floor Panel · damagedPANEL 241ABF PANEL ASSEMBLY - PASSENGER CABIN FLOOR HAS FIBERS MISSING. / [01] REMOVED AND REPLACED FLOOR PANEL IAW AMM 53-21-00;[02] C/W OK TO INSTALL INSPECTION;[03] C/W INSPECTIONSDR SWAA2022060807449Floor Panel · damagedPANEL 241AAF PANEL ASSEMBLY - PASSENGER CABIN FLOOR HAS FIBERS MISSING. / [01] REMOVED AND REPLACED FLOOR PANEL IAW AMM 53-21-00;[02] INSPECTED AS REQUIRED
Back to Boeing 737-8H4