Boeing 737-8Q8
Service difficulty reports · 1,686
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378Q8' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7378Q8' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SCNA20150211040Floor Support · corrodedCORROSION ON INTERCOSTAL BETWEEN FLOORBEAMS, BS 947.5 - 967. JUST INSIDE R2 DOOR NEAR FLOOR DRAIN & FWD END. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. REPLACED WITH NEW PART.SDR SCNA20150211018Support · corrodedAFT CARGO BAY THRESHOLD SUPPORT STRUCTURE HAS SURFACE CORROSION LOCATED AT FS 797 TO FS 827. CORROSION IN SEVERAL AREAS. REMOVED CORROSION FROM WEB FOUND TO BE OUT OF LIMITS. R & R WEB.SDR SCNA20150211026Support · corrodedFWD CARGO BAY RT SIDE AT BS 400 ON BULKHEAD PANEL SUPPORT BOTTOM CORNER AREA OFF CORROSION. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED PART AND INSTALLED NEW.SDR SCNA20150211024Failsafe · bentFWD CARGO BAY FAIL SAFE AT FS 500D FROM STR 22 TO 25 IS BENT. REMOVED DAMAGED FAIL SAFE, LOCATED AND DRILLED AND INSTALLED NEW FAIL SAFE.SDR SCNA20150211021Support · corrodedAFT CARGO BAY AT FS 767 TO 787 LBL, 22 CAP STRIP HAS SURFACE CORROSION AROUND NUT PLATE HOLES 3 EA. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. R & R TRANSITIONAL PANEL.SDR SCNA20150211017Support · corrodedAFT CARGO LT SIDEWALL PANEL 141HW CAPSTRIP HAS CORROSION ON LWR SURFACE. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. FABRICATED NEW SIDEWALL.SDR SCNA20150211016Floor Panel · corrodedAFT CARGO NR 4 FLOOR PANEL HAS CORROSION. FOUND OUF OF LIMITS. FABRICATED NEW AFT CARGO NR 4 FLOOR PANEL FWD SPLICE.SDR SCNA20150211025Transition Panel · corrodedFWD CARGO BAY RT SIDE TRANSITION PANEL FROM BS 492 TO 500A AREAS OF CORROSION. REMOVED TRANSITION PANEL. FABBED NEW TRANSITION PANEL, LOCATED, DRILLED AND INSTALLED.SDR SCNA20150211041Floor Panel · corrodedAFT CARGO FLOOR PANEL SPLICE AT BS 887, CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. FABRICATED NEW AFT CARGO FLOOR PANEL.SDR SCNA20150211035Frame · corrodedFWD LT WET AREA FRAME TOPSIDE HAS CORROSION BS 328, LBL 10. BLENDED CORROSION FOUND OUT OF LIMITS. REPAIRED 328 FRAME.SDR SCNA20150211034Frame · corrodedFWD LT WET AREA FRAME TOP SIDE HAS CORROSION, BS 344 BETWEEN RBL 0 TO LBL 24. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REPAIRED.SDR SCNA20150211033Frame · corrodedFWD RT WET AREA FRAME TOPSIDE HAS CORROSION STA 344 BETWEEN RBL 0 AND RBL 10. BLENDED CORROSION FOUND OUT OF LIMITS. REPAIRED.SDR SCNA20150211029Seat Track · corrodedFWD RT WET AREA FRAME HAS CORROSION ON TOP SIDE, BS 328 AT FWD END OF SEAT TRACK 44R EXTENDING UNDER SEAT TRACK. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REPAIRED STA 328, FRAME.SDR SCNA20150211028Channel · corrodedFWD RT WET AREA BS 328, 2" INBD OF INNER CORD, MOP SILL, HAS CORROSION ON TOP SIDE AROUND FASTENER HOLE. BLENDED CORROSION STA 328 2" INBD OF INNER CHORD FOUND TO BE OUT OF LIMITS. REPAIRED STA 328, FRAME.SDR SCNA20150211023Floor Support · corrodedAFT CARGO BAY JUST AFT FS 727D, RBL 22 CAP STRIP HAS 2 EA AREAS OF SURFACE CORROSION LOCATED ON PREVIOUS REPAIR TO CAP STRIP & JUST FWD OF REPAIR. R & R ZEE CHANNEL, RBL 22 FROM 727 TO 767.SDR SCNA20150211020Scuff Plate · corrodedAFT CARGO SCUFF PLATE HAS EXCESS EDGE BLEND & CRACKED IN BLENDED AREA. INSTALLED NEW PART.SDR SCNA20150211014Scuff Plate · crackedAFT CARGO FWD SCUFF PLATE AFT END CRACKED. WELDED PERMANENT REPAIR TO AFT CARGO, FWD CORNER, SCUFFPLATE, CRACK ON AFT END.SDR SCNA20150119005Battery Pack · inoperativeFOUND BATTERY PACKS BAD. R & R BATTERY PACKS.SDR ASMF201503003Control Valve · failedCAPTAIN REPORTED THAT DURING LANDING, THE CONTROL TOWER INFORMED THAT EXCESSIVE SMOKE WAS OBSERVED IN THE LT MLG. MX WAS INFORMED BY GND PERSONNEL THAT LT MLG TIRE WAS FLATTED, SO THE FLAT SPOTTED TIRES CONDITIONAL INSPECTION WAS PERFORM IAW AMM 05-51-16-210-SDR SCNA20150119004Stiffener · crackedRIGHT HORIZONTAL STABILIZER RIB VERTICAL STIFFENER AT STA 92.7 CRACKED ON LWR END. REPAIRED CRACKED STIFFENER.SDR SCNA20150119003Vertical Support · crackedLT HORIZONTAL STABILIZER RIB VERTICAL STIFFENER AT STA 129.5 CRACKED ON LOWER END. REPAIRED CRACK.SDR SCNA20150119002Skin · gougedDURING REMOVAL OF RT HORIZONTAL STABILIZER L/E, FOUND A GOUGE APPROXIMATELY BS 132. BLENDED GOUGE FOUND TO BE OUT OF LIMITS, REPAIRED.SDR ASMF201501026Starter · damagedAIRCRAFT RETURNED TO PLATFORM AS A CONSEQUENCE THAT DURING LT ENG START, THE RIGHT START VALVE OPEN LIGHT TURNED ON. REPLACED THE LT ENG STARTER IAW AMM 80-11-01, TESTED CORRECT.SDR ASMF201501021Pump · leakingDURING TRANSIT CHECK, IT WAS DETECTED A HYD LEAK IN THE RT ENG. PERFORMED REVISION DETECTING HYD LEAK AT THE ENG DRIVEN PUMP DRAIN PORT. THE ENG DRIVEN PUMP WAS REPLACED IAW MM 29-11-11, TESTED CORRECT.SDR ASMF201501019Blade · damagedDURING TRANSIT CHECK, IT WAS DETECTED NICKS IN TWO INLET CASE FAN BLADES OF THE RT ENG. PERFORMED REVISION DETECTING TWO NICKS OUT OF LIMIT IAW AMM 72-24-02. INSPECTION PERSONNEL EVALUATED THE DAMAGE, CONFIRMING THE NICKS OUT OF LIMITS IAW AMM 72-24-02. THESDR SCNA20141212214Wire · damagedR1 DOOR SLIDE EMERGENCY LIGHT INOPERATIVE AND KEEPS POPPING THE FUSE IN THE CHARGER. REPAIRED WIRING FROM CONNECTOR, D10748, PIN 12 TO CONNECTOR, D12052, PIN 2 AT ROW 1, SEAT AB.SDR SCNA20141211213Placard · detachedPLASTIC EXIT SIGN FELL OFF BETWEEN DOOR L1 AND FWD F/A JUMPSEAT. SECURED PLASTIC EXIT SIGN AT L1 DOOR.SDR SCNA20141126211Placard · detachedDOOR EXIT SIGN FELL OFF BETWEEN L1 AND FWD F/A JUMPSEAT. SECURED PLASTIC SIGN.SDR SCNA20141124191Intercostal · corrodedDURING GVI IN FWD CARGO AFTER RT TRANSITION PANEL REMOVAL, FOUND INTERCOSTAL BS 500G-500H CORRODED. REMOVED CORROSION AND FOUND OUT OF LIMITS. R & R THE INTERCOSTAL.SDR SCNA20141124194Floorbeam · corrodedFLOORBEAM AT BS 887 IS CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS. REPAIRED THE FLOORBEAM.SDR SCNA20141124186Structure · corrodedLEFT AFT LAVATORY HAS EVIDENCE OF CORROSION ON UNDERSIDE SURFACE OF FLOOR AND AFT WALL. BONDED PERMANENT REPAIRS TO LEFT AFT LAV, AFT INBD & OTBD, FWD INBD MOUNT BLOCKS AND AFT DOOR CELL REPAIR.SDR SCNA20141124174Floorbeam · corrodedFLOORBEAM BS 296 HAS CORROSION ON UPPER SURFACE RBL 21 TO SIDE WALL. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REPAIRED THE FLOORBEAM.SDR SCNA20141124179Floorbeam · corrodedFLOORBEAM AT BS 986.5 IS CORRODED FROM L2 DOOR TO R2 DOOR ON TOP SURFACE. FOUND TO BE OUT OF LIMITS. REPLACED UPPER FLOORBEAM TEE.SDR SCNA20141124176Floorbeam · corrodedFLOORBEAM IS CORRODED BS 360 RBL 48. BLENDED AND FOUND TO BE OUT OF LIMITS. REPAIRED THE FLOORBEAM.SDR SCNA20141124183Floor Support · corrodedFLOOR SUPPORT FROM BS 947.5 - 967 IS CORRODED. BLENDED CORROSION ON THE FLOOR SUPPORT AND FOUND IT TO BE OUT OF LIMITS. R & R THE FLOOR SUPPORT.SDR SCNA20141124196Structure · corrodedFWD CARGO BAY AFT BULKHEAD RT CAP STRIP LOCATED AT BS 500H-500I HAS SURFACE CORROSION. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS, R & R.SDR SCNA20141124195Structure · corrodedFWD LAVATORY FLOOR HAS CORROSION DAMAGE. REPAIRED.SDR SCNA20141124184Floor Support · corrodedFLOOR SUPPORT JUST AFT OF BS 947.5 LT SIDE IS CORRODED. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. R & R THE FLOOR SUPPORT.SDR SCNA20141125209Support · corrodedDURING GVI IN FWD CARGO BAY AFTER RT TRANSITION PANEL REMOVAL, FOUND RT AFT BULKHEAD LOWER SUPPORT INBD END CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R SUPPORT.SDR SCNA20141124203Angle · corrodedPASSENGER CABIN R1 DOOR SILL ANGLE IS CORRODED. BLENDED CORROSION AND FOUND IT TO BE OUT OF LIMITS. REMOVED AND REPLACED THE ANGLE.SDR SCNA20141124187Floor Support · corrodedAFT CARGO BAY RT FLOOR SUPPORT AT RBL 16 IS CORRODED FROM BS 767-887. REMOVED THE CORROSION AND FOUND IT TO BE OUT OF LIMITS. R & R THE FLOOR SUPPORT.SDR SCNA20141124175Floorbeam · corrodedFLOORBEAM BS 328 HAS CORROSION ON UPPER SURFACE AT APPROXIMATELY RBL 45. REPAIRED THE FLOORBEAM.SDR SCNA20141124185Floorbeam · corrodedFLOORBEAM TEE AT BS 947.5 IS CORRODED AT LBL 6 AND RBL 6. BLENDED CORROSION AND FOUND IT TO BE OUT OF LIMITS. REPAIRED FLOORBEAM TEE.SDR SCNA20141124180Floor Support · corrodedFLOOR SUPPORT FROM BS 947.5 - 986.5, RBL18 FOUND CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R THE FLOOR SUPPORT.SDR SCNA20141124192Intercostal · corrodedDURING GVI IN FWD CARGO AFTER RT TRANSITION PANEL REMOVAL, FOUND AN INTERCOSTAL BS 500H-500I CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R THE INTERCOSTAL.SDR SCNA20141124190Intercostal · corrodedDURING GVI IN FWD CARGO, AFTER RT TRANSITION PANEL REMOVAL, FOUND INTERCOSTAL BS 500E-500F CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. R & R INTERCOSTAL.SDR SCNA20141124182Web · corrodedFLOOR WEB IS CORRODED IN CORNER AT BS 986.5 RBL30. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R THE WEB.SDR SCNA20141124181Floor Support · corrodedFLOOR SUPPORT AT R2 DOOR IS CORRODED FROM BS 947 - 996. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R THE FLOOR SUPPORT.SDR SCNA20141124177Channel · corrodedCHANNEL CORRODED AT BS 990 INBD OF R2 DOOR. REMOVED CORROSION ON CHANNEL AND FOUND TO BE OUT OF LIMITS. R & R THE CHANNEL.SDR CA141117004Oven · smoke(CAN) FWD GALLEY OVEN PRODUCING SMOKE FROM TOP AND SIDE. C/B PULLED AND CABIN UTILITY SELECTED OFF. FWD GALLEY OVEN REMOVED AND FOUND OVEN BEING THE CAUSE OF SMOKE. FWD GALLEY OVEN DEACTIVATED C/PULLED AND COLLARDED. WIRING INSPECTED WITH NO FAULT. FWD GAL
Back to Boeing 737-8Q8