Boeing 737-8Q8

Service difficulty reports · 1,686

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '7378Q8'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SCNA20141125208Structure · corrodedAFT CARGO BAY LT CAP STRIPS ARE CORRODED ON LOWER SURFACE. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. FABRICATED AND RESTORED FINISH.Nov 14, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141124202Floor Support · corrodedAFT CARGO BAY LT FLOOR SUPPORT BS 727 - 727H HAD SEVERAL SPOTS OF SURFACE CORROSION. BLENDED CORROSION AND FOUND OUT OF LIMITS. R & R FLOOR SUPPORT.Nov 14, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141124201Floor Support · corrodedAFT CARGO BAY FLOOR SUPPORT BS 727H - 787 HAD SEVERAL SPOTS OF CORROSION. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R FLOOR SUPPORT.Nov 14, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141124189Floor Support · corrodedAFT CARGO FLOOR SUPPORT AT BL 0 CORRODED AT BS 887. BLENDED THE CORROSION FOUND IT TO BE OUT OF LIMITS. FABRICATED AND INSTALLED A NEW FLOOR SUPPORT.Nov 14, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141125207Closeout Panel · corrodedAFT CARGO DOOR CUT OUT FWD WEB LOWER CLOSE OUT PLATE IS CORRODED ON LOWER SIDE. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. FABRICATED NEW CLOSE OUT PLATE.Nov 13, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141125206Strap · corrodedAFT CARGO PIT FLOOR SUPPORT ATTACH STRAP BS 727D IS CORRODED. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. FABRICATED NEW STRAP.Nov 13, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141125205Strap · corrodedAFT CARGO PIT FLOOR SUPPORT ATTACH STRAP BS 727 IS CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS. FABRICATED NEW STRAP.Nov 13, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141125204Strap · corrodedAFT CARGO BAY FLOOR SUPPORT ATTACH STRAP BS 767 IS CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS. FABRICATED NEW STRAP.Nov 13, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141124173Bulb · damagedR2 DOORWAY HEADER EMERGENCY LIGHT HAS ONE BULB DAMAGED. R & R THE BULB.Nov 13, 2014 · N816SY · Boeing 7378Q8 · Emergency LightingSDR SCNA20141124188Floor Support · corrodedAFT CARGO FLOOR SUPPORT AT RBL 22 IS CORRODED ON UNDERSIDE BETWEEN BS 787-793. THE FLOOR SUPPORT FOUND TO BE 100 PERCENT MATERIAL LOSS, R & R THE FLOOR SUPPORT.Nov 12, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141124200Strap · corrodedAFT CARGO BAY FLOORBEAM STRAP AT BS 887 CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. FABRICATED A NEW STRAP.Nov 11, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141124199Transition Panel · corrodedAFT CARGO BAY RT TRANSITION PANEL BS 867-887 CORRODED. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R TRANSITION PANEL.Nov 11, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141124198Transition Panel · corrodedAFT CARGO BAY TRANSITION PANEL AFT OF DOOR CUTOUT FROM BS 847-867 CORRODED ON UPPER AND LOWER SURFACE. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R TRANSITION PANEL.Nov 11, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141124193Stiffener · crackedDURING RT HORIZONTAL LOWER SKIN REPLACEMENT, FOUND NR 1 IN SPAR RIB STA 92.70 SECOND VERTICAL STIFFENER CRACKED. REPAIRED NR 1 IN SPAR RIB 2ND VERTICAL STIFFENER.Nov 11, 2014 · N816SY · Boeing 7378Q8 · Horizontal Stabilizer StructureSDR SCNA20141124197Floorbeam · corrodedFWD CARGO BAY RT FLOORBEAM CAP JUST AFT OF BS 500F HAS SURFACE CORROSION AND IS OUT OF LIMITS, R & R.Nov 5, 2014 · N816SY · Boeing 7378Q8 · Fuselage Main, Floor BeamSDR SCNA20141124178Web · corrodedRIGHT FLOOR WEB IS CORRODED IN TWO PLACES BETWEEN BS 1006 & 1016. FLOOR WEB FOUND TO BE OUT OF LIMITS. R & R WEB.Nov 5, 2014 · N816SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20141027147Lamp · inoperativeCABIN EMERGENCY LIGHTS ARE INOPERATIVE. REPLACED THE LAMPS.Oct 24, 2014 · N804SY · Boeing 7378Q8 · Emergency LightingSDR SCNA20141013140Lens · missingEMERGENCY LIGHT LENS COVER IS MISSING AT ROW 1ABC, REPLACED LENS.Oct 11, 2014 · N813SY · Boeing 7378Q8 · Emergency LightingSDR SCNA20141013139Lamp · inoperativeEMERGENCY LIGHT AT OVERHEAD BIN 21DEF IS INOPERATIVE, REPLACED THE LAMPS.Oct 11, 2014 · N813SY · Boeing 7378Q8 · Emergency LightingSDR SCNA20141013138Wire · unsecureEMERGENCY LIGHTS BETWEEN SEATS 19ABC AND 23ABC IS INOPERATIVE. SECURED WIRES IN RECEPTACLE.Oct 11, 2014 · N813SY · Boeing 7378Q8 · Light System WiringSDR SCNA20140922132Floorbeam · gougedFLOORBEAM BS 328 GOUGED DOWN THE AFT SIDE UNDER THE CUSP INSTALLATION ON THE RT SIDE, REPAIRED THE FLOORBEAM.Sep 20, 2014 · N801SY · Boeing 7378Q8 · Fuselage Main, Floor BeamSDR SCNA20140922130Floorbeam · corrodedPASSENGER CABIN FWD WET AREA BS 328 FLOORBEAM CORRODED AT SEVERAL SPOTS. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REPAIRED THE FLOORBEAM.Sep 20, 2014 · N801SY · Boeing 7378Q8 · Fuselage Main, Floor BeamSDR SCNA20140922129Floor Support · corrodedFWD CARGO BAY, LT SIDE FROM BS 400-500A FLOOR SUPPORT IS CORRODED. BLENDED CORROSION AND FOUND OUT OF LIMITS. R & R THE FLOOR SUPPORT.Sep 20, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140922128Floor Support · corrodedFWD CARGO BAY, LT SIDE FROM BS 500A - 5000H FLOOR SUPPORT CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS. R & R THE FLOOR SUPPORT.Sep 20, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140922133Intercostal · crackedDURING FWD CARGO LT TRANSITION REPAIR SPLICE FOUND CRACKED INTERCOSTAL BS 500G - 500H. R & R THE INTERCOSTAL.Sep 19, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140922131Intercostal · corrodedDURING FWD CARGO LT TRANSITION PANEL REPAIR, SPLICE FOUND CORRODED AT INTERCOSTAL BS 500F - 500G. R & R INTERCOSTAL.Sep 19, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140922127Floor Support · corrodedAFT CARGO BAY, RBL 14 FLOOR SUPPORT STRUCTURE LOCATED AT BS 794 - 887 HAS SEVERAL AREAS OF SURFACE CORROSION. CORROSION FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED SECTION AND INSTALLED NEW SECTION.Sep 19, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140919125Web · corrodedAFT CARGO DOOR CUTOUT BOTTOM WEB HAS LARGE AREA OF CORROSION ON TOP AND BOTTOM SURFACES. CORROSION FOUND TO BE 100 PERCENT MATERIAL LOSS. R & R WEB.Sep 19, 2014 · N801SY · Boeing 7378Q8 · Fuselage Main, StructureSDR SCNA20140919124Floor Support · crackedDISCOVERED CRACKED FLOOR SUPPORT AT BL 0 BETWEEN BS 344 - 360 FLOORBEAMS. R & R FLOOR SUPPORT.Sep 18, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140919122Floor Support · corrodedPASSENGER CABIN FWD WET AREA FROM BS 312 - 328, RBL 10 FLOOR SUPPORT CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. R & R FLOOR SUPPORT.Sep 18, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140919120Structure · corrodedPASSENGER CABIN AFT WET AREA FS 986.5, 2.5 INCHES INBD OF MOP SILL AT L2 DOOR, CORRODED. REMOVED CORROSION FOUND TO BE OUT OF LIMITS, REPAIRED.Sep 18, 2014 · N801SY · Boeing 7378Q8 · Fuselage Main, StructureSDR SCNA20140919126Channel · corrodedPASSENGER CABIN AFT WET AREA AT L2 DOOR MOP SILL HAS CORROSION IN SEVERAL AREAS. CORROSION EXTENDS UNDER L2 DOOR THRESHOLD. FOUND TO BE OUT OF LIMITS. R & R MOP SILL AT L2.Sep 17, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140919123Frame · corrodedPASSENGER CABIN AFT WET AREA BS 947.5 AT LBL 4 & 12 AND RBL 4 HAS SURFACE CORROSION LOCATED ON TOP OF FRAME. REMOVED CORROSION FOUND TO BE OUT OF LIMITS. REPAIRED.Sep 14, 2014 · N801SY · Boeing 7378Q8 · Fuselage Main, FrameSDR SCNA20140917118Floorbeam · corrodedPASSENGER CABIN AFT WET AREA AFT & INBD OF R2 DOOR AT FS 992, RBL 32 TO 42, G4 GALLEY FLOOR SUPPORT HAS SURFACE CORROSION. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. FABRICATED AND INSTALLED NEW FLOOR SUPPORT.Sep 14, 2014 · N801SY · Boeing 7378Q8 · Fuselage Main, Floor BeamSDR SCNA20140919121Beam · corrodedPASSENGER CABIN AFT WET AREA INBD OF L2 DOOR AT BS 967, LBL 36 HAS CORROSION ON TOP SURFACE OF BEAM . BLENDED CORROSION IAW EA 15791 FOUND TO BE OUT OF LIMITS.Sep 12, 2014 · N801SY · Boeing 7378Q8 · Fuselage Main, StructureSDR SCNA20140917119Floor Support · corrodedPASSENGER CABIN FWD WET AREA FROM BS 294.5 - 312 AND ABOUT RBL 10 FLOOR SUPPORT STRUCTURE CORRODED. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED FLOOR SUPPORT.Sep 11, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140917117Spar · crackedFOUND TWO CRACKS IN LT WING CENTER SECTION REAR SPAR BETWEEN LBL 24.92 AND LBL 45.64. CRACK OUT OF LIMITS. REPAIRED LT WING CENTER SECTION REAR SPAR.Sep 11, 2014 · N801SY · Boeing 7378Q8 · Wing SparSDR SCNA20140917116Floor Support · corrodedPASSENGER CABIN FWD WET AREA FROM BS 328 - 344 AND ABOUT LBL 10 FLOOR SUPPORT CORRODED. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. R & R FLOOR SUPPORT.Sep 11, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140917115Floor Support · corrodedPASSENGER COMPARTMENT FWD WET AREA FROM BS 312 - 328 AND ABOUT LBL10 FLOOR STRUCTURE CORRODED. BLENDED CORROSION FOUND TO BE OUT OF LIMITS. R & R FLOOR SUPPORT.Sep 11, 2014 · N801SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140917114Floorbeam · corrodedAFT CARGO BAY BS 887 FLOORBEAM HAS CORROSION BETWEEN RBL 3 & 10. FOUND TO BE OUT OF LIMITS. FABRICATED NEW FLOORBEAM ANGLE.Sep 11, 2014 · N801SY · Boeing 7378Q8 · Fuselage Main, Floor BeamSDR SCNA20140916113Seat Track · unknownMAJOR REPAIR. REPLACED SEAT TRACKS LBL 45.5 & RBL 24.75 AND FASTENERS AT THE FWD END.Sep 10, 2014 · N801SY · Boeing 7378Q8 · Fuselage, Seat/Cargo Attach FittingsSDR ASMF201409010Warning System · false activationAIRCRAFT REJECTED TAKE OFF AT 60 KNOTS DUE TO THE ENTRY DOOR LIGHT TURNED ON. THE FLIGHT CREW PERFORMED THE QRH 1.8 PROCEDURE, NO CONFIRMING THE FAILURE & INITIATING AGAIN SEQUENCE OF TAKEOFF. AS PRECAUTIONARY ACTION, PERFORMED BITE TO ENTRY DOOR FLIGHT LOOKSep 1, 2014 · N859AM · Boeing 7378Q8 · Door Warning SystemSDR SCNA20140820110Light · unsecureEMERGENCY EXIT LIGHT ACROSS ROW 1 IS NOT SECURED TO FLOOR. REPLACED LIGHT ASSY & LENS COVER.Aug 19, 2014 · N813SY · Boeing 7378Q8 · Emergency LightingSDR SCNA20140818108Light · inoperativeFOUND FWD GALLEY LT WINDSCREEN EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT & OPS CHECK GOOD.Aug 14, 2014 · N813SY · Boeing 7378Q8 · Emergency LightingSDR SCNA20140807107Light · damagedEMERGENCY LIGHT AT SEAT 1C DAMAGED. REPLACED EMERGENCY LIGHT.Aug 5, 2014 · N813SY · Boeing 7378Q8 · Emergency LightingSDR ASMF201408003Connector · looseDURING TRANSIT CHECK, A HYD LEAK WAS DETECTED OF 2 DROPS PER MINUTE IN THE NOSE WHEEL STEERING. DURING MX REVISION, THE RT NOSE WHEEL STEERING CYLINDER CONNECTOR WAS DETECTED LEAKING WITHIN LIMITS, SO THE STEERING CYLINDER CONNECTOR WAS TIGHTENED & CLEANED IAJul 20, 2014 · N859AM · Boeing 7378Q8 · Landing Gear Steering SystemSDR SCNA20140617105Flap System · malfunctionedSELECTED FLAPS 1 AT APPROX 230 KIAS AND FLAPS INDICATED T/E ASYMMETRY.Jun 16, 2014 · N801SY · Boeing 7378Q8 · Trailing Edge Flap Control SystemSDR ASMF2014061806019Blade · lack of lubeCAPTAIN REPORTED THAT DURING CLIMB, THE LT ENG VIBRATION REACHED 3.1 UNITS & DURING CRUISE THE VIBRATION WAS STABILIZED IN 4.1 UNITS. ACFT WAS SENT TO THE HANGAR & A BORESCOPE INSPECTION IAW AMM 72-00-00-200-808-F00, TRIM BALANCE IAW AMM 71-00-00 TASK 71-00-0May 27, 2014 · N858AM · Boeing 7378Q8 · Turbine Engine Compressor SectionSDR SCNA20140527076Door Sill · corrodedAFT CARGO DOOR SURROUND LOWER SILL PLATE CORRODED ON UPPER AND LOWER SURFACE. AFT CARGO DOOR SURROUND LOWER SILL PLATE FOUND TO BE OUT OF LIMITS. FABRICATED WEB AND INTALLED.May 18, 2014 · N713SY · Boeing 7378Q8 · Fuselage Miscellaneous StructureSDR SCNA20140527075Cargo Track · corrodedAFT CARGO BAY TIE DOWN TRACK AT LBL 3.0, CORRODED AROUND NUTPLATES AT THE AFT TIE-DOWN JUST FWD OF BS 943. BLENDED CORROSION ON TIE DOWN TRACK AND FOUND TO BE OUT OF LIMITS. R & R TRACK ASSY.May 16, 2014 · N713SY · Boeing 7378Q8 · Fuselage, Seat/Cargo Attach Fittings
Back to Boeing 737-8Q8