Boeing 737-924
Service difficulty reports · 828
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2011120900803Control Panel · faultyFAULT LIGHT AND APU DET INOP LIGHT ILLUMINATED ENGINE AND APU FIRE DETECTION SYSTEM WILL NOT TEST. WHEEL WELL FIRE DETECTION SYSTEM TEST OK. T/S PER FIM TASK 26-10-00-810-801 FOUND ALL LIGHTS ILLUMINATED ON FRONT OF ENG/ APU FIRE DETECTION CONTROL MODULE M 2SDR CALA2011112200763Duct · separatedRT DUCT PRESS & LT; 10 PSI AT CLIMB PWR ON GROUND 0 PSI. T/S FOUND ECS CONTROL LINE P/N 332A2350-14 SEPARATED. REPOSITIONED PRECOOLER CONTROL VALVE AND REPLACED LINE AS REQ`D PERFORMED ENGINE RUNS, PNEUMATIC PRESSURES NORMAL.SDR CALA2011112100754Fire Bottle · leakingEN ROUTE THE FIRE EX-SEAL BROKE AND DISCHARGED (COCKPIT BOTTLE). REMOVED AND REPLACED COCKPIT HALON FIRE EXTINGUISHER. OK TO CONTINUE.SDR CALA2011102800695Battery Pack · dischargedROW 20 & 21 A/F OVERWING EXIT SIGNS REMAIN DIM AFTER EMERGENCY LIGHT TEST. REMOVED AND REPLACED BATTERY PACKS 1674 & 1675. EMERGENCY LIGHT SYSTEM (ELS) FUNCTIONALLY CHECKS GOOD. NOTE SIDEWALL LIGHTING IN BRIGHT BLEEDS THRU EXIT SIGN ASSEMBLY WHEN SWITCH TO SDR CALA2011090100569Power Supply · inoperativeDURING RON CHECK, FOUND SEAT MOUNTED EMERGENCY LTS FROM 22ABC - 26ABC INOP. FOUND POWER SUPPLY BAD. REMOVED & REPLACED POWER SUPPLY ASSY REF AMM 33-51-06-960-806. OPS CHECKS GOOD.SDR CALA2011082200549Smoke Detector · false activationFWD LAV SMOKE ALARM ACTIVATED WOULD NOT RESET CONTINUED SOUNDING ALARM FOUND FWD LAV DEODORIZER VERY CLOSE TO THE SMOKE DETECTOR TRIGGERING OFF ALARM DETECTOR NO SMOKE OR OVEN OVER TEMPERATURE NOTED PER AMM 26-14-00-730-801. REMOVED DEODORIZER FROM THAT AREA,SDR CALA2011040100251Casting · failedPANEL ON TOP OF LEFT WING NEXT TO FLIGHT SPOILERS RAISED DURING FLIGHT. R&R FITTING/CASTING P/N 115A2179-1 ATTACHED TO PANEL P/N 115A25 12-9.REF L/P 4344541,4344542 & 4344543 FOR REPAIR.SDR CALA2011021000081Light · inoperativeL1 DOOR EXTERNAL EMERGENCY LIGHT INOP. RELAMPED, OPS CHECKS GOOD.SDR CALA2011012800047Charger · inoperativeEMERGENCY EXIT LIGHT AT OVERWING EXIT INOP. FOUND BATTERY CHARGER M1694 INOP. R&R`D CHARGER, OPS CHECKS OK.SDR CALA2011032900221Frame · crackedFOUND CRACK INDICATION AT RT FRAME AT STA 480 AT AC SUPPORT BRACKET MARKED AS PER EA 5310-04716 REV A. REPAIRED FRAME IN ACCORDANCE WITH EA 5310-04716 REV A.SDR CALA2011032900218Frame · crackedFOUND CRACK ON RT FRAME AT STA 380 AT A/C SUPPORT BRACKET MARKED AS PER EA 5310-04716 REV A. REPAIRED FRAME IN ACCORDANCE WITH EA 5310-04716 REV A.SDR CALA2011032900217Frame · crackedFOUND CRACK ON RT FRAME AT STA 440 AT A/C SUPPORT BRACKET MARKED AS PER EA 5310-04716 REV A. REPAIRED FRAME IN ACCORDANCE WITH EA 5310-04716 REV A.SDR CALA2011032900216Frame · crackedFOUND CRACK ON RT FRAME AT STA 500A AT A/C SUPPORT BRACKET MARKED AS PER EA 5310-04716 REV A. REPAIRED CRACK W/REF TO EA 5310-04716 REV A.SDR CALA2011032900215Frame · crackedFOUND CRACK ON RT FRAME AT STA 500D AT A/C SUPPORT BRACKET. REPAIRED FRAME IN ACCORDANCE WITH EA 5310-04716 REV A.SDR CALA2011032900236Skin · dented(BIRD STRIKE) DENT FOUND JUST ABOVE STRINGER 24L BETWEEN STSTION 211.8 AND 219.8. DIMENSIONS WERE 6(W) .225(Y) =26.6 DENT FOUND TO BE OUT OF LIMITS PER SRM 53-00-01 ALLOWABLE DAMAGE 1 PAGE 107 (3B) AN OIL CAN CONDITION IS ALSO NOTED ON THIS DENT. INSPECT THESDR CALA2010121300612Snubber · brokenFOUND L1 DOOR SNUBBER BROKEN. REMOVED AND REPLACED L1 DOOR SNUBBER ASSY. REF AMM 52-11-51-400-801. OPS CHECK NORMAL. NO OTHER DEFECTS NOTED. OK TO CONTINUE.SDR CALA2010111100535Drain Line · obstructedREF "A" CHECK WORK CARD 29-5440-1-2102 NR 2 ENG PYLON FOUND 2 TO 3 GALLONS OF FUEL IN PYLON REF L/P 8665875 FOR FUEL LEAK CLEANED FUEL FROM PYLON NR 2 FOUND SUMP DRAIN INLET SEALED WITH PRC SEALANT CLEANED SEALANT FROM SUMP DRAIN AND CHECKED DRAIN FUNCTION CHESDR CALA2010101100478Floor Panel · puncturedSUPPORT TASK - CABIN FLOOR PANEL 242AF HAS NUMBEROUS PUNCTURED HOLE. FABRICATED FLOOR PANEL 242AF PER EC/RA 5320-01448.SDR CALA2010091700438Skin · crackedSUPPORT TASK. RT HORIZONTAL STAB HAS A 1" LONG CRACK IN THE LOWER SKIN STAB STA 101.9 I/B SIDE OF RIB. 27.5" AFT OF L/E OF SKIN PANEL AND 19.5" FWD OF AFT EDGE OF SKIN PANEL REPAIRED CRACK ON R/H HORIZONTAL STAB AND DAMAGED RIB PER ECRA# 5510-02120. PLACED ON SDR CALA2010091700437Skin · crackedSUPPORT TASK. RT HORIZONTAL STAB HAS A .75 INCH LONG CRACK IN THE LOWER SKIN STAB STA 101.9 I/B SIDE OF RIB, 8 INCH AFT OF DRAIN HOLE AND 10.5 INCH FWD OF AFT EDGE OF SKIN PANEL REPAIRED CRACK ON RT HORIZONTAL STAB PER ECRA#5510-02120. PLACED ON DIP TO ACCOMPSDR CALA2010091700427Floorbeam · corrodedFLOORBEAM AT STA 986.5 RT SIDE HAS CORROSION AT FASTENER HOLE APPROX RBL 4.5 (MARKED). REMOVED DAMAGED SECTION OF FLOORBEAM, FAB'D REPAIR PIECES, TREATED, PRIMED AND INSTALLED IN REF TO SRM 53-00-51 REPAIR 1.SDR CALA2010072000343Battery Pack · dischargedEMERGENCY BATT PACK PER CARD 29-3350-1-7100 LEFT EXIT BATT BAD. REPLACED BATT PACK ROW 15 A FOR LEFT EXIT OVERWING DOOR, OPS GOOD PER CARD 29-3350-1-7100.SDR CALA2010072000342Frame · crackedB757-53-3-0739 FWD PASS CABIN UPPER INTERNAL LOBE FRAME CRACKED AT PSU RAIL SUPPORT BRACKET FASTENER STA 380 BETWEEN S-8R AND S-9R. FABRICATED AND INSTALLED REPAIR ANGLES ON FUSELAGE FRAME AT PSU ATTACHMENT BRACKET AT STA 380 S-8R TO S-9R REF EC/RA 5310-05234SDR CALA2010072000341Frame · crackedFWD PASS CABIN UPPER INTERNAL LOBE FRAME CRACKED AT PSU RAIL SUPPORT BRACKET FASTENER LOCATION STA 480 S-8R AND S-9R FABRICATED AND INSTALLED REPAIR ANGLES ON FUSELAGE FRAME AT PSU ATTACHMENT BRACKET STA 480 S-8R AND S-9R REF EC/RA 5310-05234.SDR CALA2010072000340Frame · crackedFWD PASS CABIN UPPER INTERNAL LOBE FRAME CRACKED AT PSU RAIL SUPPORT BRACKET AT FASTENER LOCATION STA 500 BETWEEN S-8L AND S-9 L, FABRICATED AND INSTALLED REPAIR ANGLES ON FUSELAGE FRAME AT PSU ATTACHMENT BRACKET AT STA 500 S-8L AND S-9L.SDR CALA2010070700329Charger · inoperativeEMERGENCY LIGHTS INOP IN FORWARD COACH CABIN. REMOVED AND REPLACED BATTERY PACK AND CHARGER ASSY AT SEAT ROW 8ABC REF AMM 33-51-06. LIGHTS OPS CHECK GOOD M&E 29-3351-3-0013 AND 29-3351-3-0031.SDR CALA2010062800304Control Valve · malfunctionedA/C EXPERIENCED A PRESSURIZATION CONTROL PROBLEM AND DIVERTED INTO SAT, REF L/P 8429328. CABIN O-2 MASKS WERE DEPLOYED BY THE CREW FOR DELAY. DEPLOYED O-2 MASK GENERATORS REPLACED, OVERWEIGHT LANDING INSP C/W, LT PACK WHICH WAS ON MEL CORRECTED. RT PACK WASSDR CALA2010062300299Skin · dentedSUPPORT TASK AFT CARGO DOOR SKIN DENT AFT AND ABOVE DOOR HANDLE IS OUT OF LIMITS. REPAIRED AFT CARGO DOOR SKIN AFT AND ABOVE DOOR HANDLE PER SRM 52-00-01 REPAIR 2.SDR CALA2010062200284Frame · puncturedAFT PIT FRAME AT STATION 947.5, AT STRINGER 25R, HAS A PUNCTURE ON INNER CHORD FROM ELONGATED SCREW. PERFORMED INTERIM REPAIR PER ECRA5311-01498,PT.1. ACCOMPLISH PERMANENT REPAIR WITHIN 24 MONTHS FROM 18-JUN-10. PLANNING TO CONTACT ENGINEERING AFTER 22 MOS,SDR CALA2010043000178Battery Pack · dischargedSUPPORT TASK EMERGENCY BATTERY PACK AT SEAT 7ABC FOR THE FLOOR PROX LIGHTS IS DEAD. REPLACED EMERGENCY BATTERY PACK AT SEAT 7ABC FLOOR PROX LIGHTS, OPS CHECK GOOD IAW B737 M/M 33-51-06.SDR CALA2010042200152Floor Panel · damagedSUPPORT TASK PNL 241AF HAS EDGE DAMAGE. FABRICATED CABIN FLOOR PANEL 241AF IN REF TO ECRA5320-01448.SDR CALA2010042200151Floor Panel · damagedSUPPORT TASK FLOOR PNL 241FF HAS EDGE DAMAGE. FABRICATED CABIN FLOOR PNL 241FF IN REF TO ECRA5320-01448.SDR CALA2010042200150Floor Panel · damagedSUPPORT TASK PNL 242AF HAS EDGE DAMAGE. FABRICATED CABIN FLOOR PANEL 242AF IN REF TO ECRA 5320-01448.SDR CALA2010042200149Floorboard · damagedSUPPORT TASK PNL 242AF HAS EDGE DAMAGE. FABRICATED CABIN FLOOR PANEL 242AF IN REF TO ECRA 5320-01448.SDR CALA2010040500108Light · brokenROW, 16C SEAT WHITE EMERGENCY LIGHT ASSY BROKEN. R&R WHITE LIGHT ASSY ON SEAT 16C IAW 737N/G M/M 33-51-11. OPS CHECK GOOD.SDR CALA2010010500007Charger · inoperativeAISLE PATH LIGHTING ROWS 17 THRU 21 IS INOPERATIVE. REMOVED AND REPLACED CHARGER M1670 AND OPS CHECKED REF AMM 33-51-06. STATION 727+13.SDR CALA2009121800740Battery Pack · dischargedEMERGENCY EXIT LIGHTS OUT RIGHT SIDE JUST AFT OF O/W EXITS AND AFT EXTERIOR O/W LT AND GRN LT. REPLACED BATTERY PACK ON M1671. LIGHTS CHECK NORMAL.SDR CALA2009121700727Oxygen Gen · dischargedSEAT 5E AND F O2 MASK PANEL OPENED AFTER LANDING. FOUND 5E AND F O2 GENERATOR DEPLETED. REMOVED AND REPLACED 5E & AMP; F OXYGEN GENERATOR PER AMM 35-22-11-000-11-400-811-001 AND 35-22-11-400-804-001. ACTIVATE O2 GEN PER AMM 35-22-11-400 / -811-001.SDR CALA2009121400712Switch · malfunctionedFIRE WARNING BELL & RED FIRE WARNING BELL CUT LIGHT DOES NOT SOUND OR ILLUMINATE ON FIRE TEST. CYCLED CTR PA-1 PNL BELL CUT OUT SWITCH. PERF OPS TEST AMM 26-11-00-710-810, OPS TEST GOOD.SDR CALA2009101900631Psu · malfunctionedPASSENGER O2 MASK DOOR AT 11ABC WILL NOT FULLY RELEASE DURING O2 DROP TEST. REPLACED PSU AT ROW 11ABC P/N 417N3011-601D, S/N 07L19 IAW AMM 25-23-61. PERFORMED OPS CHECK AS PER AMM 35-22-00 WITH NO FURTHER DEFECTS NOTED. REMOVED SAFETY PIN.SDR CALA2009090800534Floorbeam · corrodedFLOORBEAM STA 344 BL 0 CORROSION IS OUT OF LIMITS. CUT OUT DAMAGE AND REPAIRED FLOORBEAM 344 AT BL 0 WITH FLOORBEAM SPLICE REPAIR REF EC/RA 5321-01687.SDR CALA2009090800533Intercostal · crackedFLOOR INTERCOSTAL CRACKED AFT OF STA 344 AT BL-0. REMOVED OLD AND INSTALLED NEW INTERCOSTAL AT BL 0, BETWEEN STA 344 & STA 360 REF SRM 51-40-02.SDR CALA2009082500488Oven · fireAFT RIGHT GALLEY OVEN CAUGHT ON FIRE, PULLED C/B OVEN NR 1. REMOVED OVEN AND INSPECTED OVEN AND INSERT. FOUND NO DAMAGE AS A RESULT OF EXCESSIVE HEAT. SUSPECT BURNING FOOD AND PRECAUTIONARY PLACARD OVEN INOPERATIVE.SDR CALA2009082400459Light · inoperativeDOOR R-2 EXTERIOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB, OPS CHECKS OK.SDR CALA2009060100287Intercostal · corrodedSUPPORT TASK - ANGLE EXTRUSION AT STA 270 BL 0 HAS CORROSION. REPAIRED EXTRUSION AT STA 270 AND CLOSED FLOOR STEP REF ECRA 5321-01646 ATTACHED: FORM 44.0008 PAGE 1 TO PAGE 2 , ITEM 1 TO ITEM 12.SDR CALA2009060100286Skin · crackedLOWER SURFACE OF RIGHT HORIZONTAL STAB SKIN IS CRACKED APPROXIMATELY 24 INCHES FROM FWD SPAR AND RIB STA 129.5. REPAIRED CRACK PER ECRA 5510-02012.SDR CALA2009060100285Skin · crackedCRACK ON LOWER SURFACE OF RIGHT HORIZONTAL STAB 18 INCHES FROM FWD SPAR AND AT STA 129.5. REPAIRED CRACK PER ECRA 5510-02012.SDR CALA2009052700277Charger · defectiveOVERHEAD EMERGENCY LIGHTS DIM ONLY AT BULKHEAD ROW. REMOVED AND REPLACED BATTERY AND BATTERY PACK ASSY CHARGER. REF AMM 33-51-06-960-806, OPS CHECK GOOD.SDR CALA2009052700276Floorbeam · corrodedB737-53-0738 AFT ENTRY FLOORBEAM STA 986.5 HAS CORROSION AT NUT PLATE HOLE APPROX RBL 4. REMOVED DAMAGED SECTION AND INSTALLED PARTS REF SRM 53-00-51 REPAIR 1.SDR CALA2009052700275Intercostal · crackedB737-53-3-0738 FLOOR STRUCTURE INTERCOSTAL BETWEEN STA 344 AND 360 LBL 11 IS CRACKED. REMOVED AND REPLACED INTERCOSTAL P/N 141A5410U22 REF SRM 51-40-02.
Back to Boeing 737-924