What was found
AFT PIT FRAME AT STATION 947.5, AT STRINGER 25R, HAS A PUNCTURE ON INNER CHORD FROM ELONGATED SCREW. PERFORMED INTERIM REPAIR PER ECRA5311-01498,PT.1. ACCOMPLISH PERMANENT REPAIR WITHIN 24 MONTHS FROM 18-JUN-10. PLANNING TO CONTACT ENGINEERING AFTER 22 MOS, BUT BEFORE 23 MOS, FOR PERM REPAIR. NOTE TO PLANNING: THIS ECRA BEING EVAL'D FOR DMG TOLERANCE UNDER 14CFR 25.571 + WILL LIKELY BECOME PERM WITH REPEAT INSPECTIONS. QC INTERIM REPAIR ACCOMPLISHED PER ECRA 5311-01498, PART 1. ACCOMPLISH A PERMANENT REPAIR WITHIN 24 MONTHS FROM 18-JUN-10. PLANNING TO CONTACT ENGINEERING AFTER 22 MONTHS BUT BEFORE 23 MONTHS FOR A PERMANENT REPAIR.