Boeing 737-924
Service difficulty reports · 828
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026021213745Probe · faultyFUEL IMBALANCE ON TANK 1 DECREASING RAPIDLY. PERFORMED NR 1 TANK FQIS DRY RESISTANCE AND CAPACITANCE CHECK IAW AMM 28-41-21-710-801, FOUND F15, F1, F2, F3, F4, F5, F6 FQIS TANK UNITS OUT OF LIMITS. R & R NR 1 FQIS TANK UNITS OUT OF LIMITS F15, F1, F2, F3, FSDR CALA2026020613608Light · wrong part15C HAS WHITE EMER LIGHT DISC VICE RED REF DRAWING 3351DD15945. REPLACED AFT WHITE LENS AT SEAT15C FOR RED LENS PER CONFIG DRAWING. OPS TESTED GOOD.SDR CALA2026020113461Sign · inoperativePASSENGER EMERGENCY SIGN AT 20CBA INOPERATIVE. R & R PASSENGER EMERGENCY SIGN AT 20CBA IAW AMM 33-51-00. OPS CHECKED GOOD.SDR CALA2026012613261Battery · failedEMERGENCY FUEL CUTOFF BATTERY REPLACED.SDR CALA2026012813404Light · inoperative20A EMERGENCY EXIT WINDOW LIGHT INOPERATIVE. RELAMPED TWICE, CHANGED FUSE, NO HELP. WINDOW LIGHT OVERWING EXIT. EMERGECY LIGHTS WORK, WINDOW LIGHT DOES NOT. REQUEST MEL APPROVED NEW BALLAST ASSEMBLY, FWD TO MEL 3302B, REPLACED THE LT FWD OVERWING EMERGENCSDR CALA2026012113122Battery Pack · no testDURING THE EMERGENCY LIGHT BATTERY CAPACITY TEST PER AMM 33-51-06-200-801, FLOOR PROX LIGHTS AT ROW 1-4 AND 7-15 FAILED THE REQUIREMENT. BATTERY PACKS AT M1674 AND M2503 NEEDS TO BE REPLACED.SDR CALA2026012013117Battery Pack · no testDURING THE EMERGENCY LIGHT BATTERY CAPACITY TEST PER AMM 33-51-06-200-801, FLOOR PROX LIGHTS AT ROW 1-4 AND 7-15 FAILED THE REQUIREMENT. BATTERY PACKS AT M1674 AND M2503 NEEDS TO BE REPLACED. PARTS ARE PLACED ON AOG. REMOVED AND REPLACED BOTH EMERGENCY SUPPLYSDR CALA2026021813886Lens · detachedEMERGENCY LIGHT AT ROW 22DEF HANGS DOWN REQUESTING MEL 3315A. COVER IS SECURED. REPLACED 22DEF AREA EMERGENCY LIGHT LENS IAW AMM 33-51-03. OPS CHECKED NORMAL, PLACARD REMOVED.SDR CALA2026011913042Light · brokenFA REPORTS EMER EXIT LIGHT BROKEN AT 20C. 1 RED LENS MISSING FROM SEAT 20 ABC. LIGHT WORKS. COVERED HOLE WITH CLEAR TAPE TO PROTECT AND INSTALLED STICKER ON P5 PANEL. REQ MEL 3319E MEL 3319E MX TO SIGN OFF INSTALLED NEW RED LENS AT SEAT 20ABCSDR CALA2026011512973Lamp · inoperativeEMERGENCY PATH LIGHT AT ROW 32ABC INOPERATIVE. REMOVED AND REPLACED FLOOR PROXIMITY LAMP AT ROW 32ABC. FLOOR PROXIMITY LIGHT OPS CHK GOOD. REF. AMM 33-51-11-960-801.SDR CALA2026011412946Warning Light · false activationFWD ENTRY ANNUNCIATOR ILLUMINATED AT 150 KTS, CONTINUED TKF AND LIGHT WENT OUT AFTER 1 MIN PERFORMED ENTRY DOOR INDICATION SENSOR TEST IAW AMM 52-71-11-710-801. OPS TESTED NORMAL.SDR CALA2026010912837Pump · failedENGINE 1 SYS A HYD PRESSURE LIGHT ILLUMINATED. FOUND NR 1 ENG DRIVEN HYDRAULIC PUMP TO HAVE COMPLETE MECHANICAL FAILURE. REMOVED ENG 1 EDP IAW AMM 29-11-11-000-801-001. UP TO AND INCLUDING STEPS F. (10) (B). INSTALLED AND COMPLETED UP TO AND INCLUDING STEPSSDR CALA2026010512666Shroud · brokenROW 25ABC EMERGENCY LIGHTING SHROUND UNDER SEAT BROKEN. REMOVED AND REPLACED ROW 25ABC EMERGENCY LIGHT HOUSING IAW AMM 33-51-11.SDR CALA2025123012552Sensor · faultedFLAP ASYM ON UPWIND 3.5/ 5. NO ABNORMAL ROLLING O R OUT OF TRIM CONDITIONS OBSERVED BITE FSEU BOX FOUND FAULT CODE FOR SKEW NR 3, RESET FSEU AND SKEW IND BREAKERS TO UNLOCK FLAPS FROM THE FROZEN POSITION , AFTER BREAKER RESET FLAP INDICATION READING NORMAL ATSDR CALA2025121712200Seal · leakingCABIN ALT WARNING AT FL350/RAN CHECKLIST, LT PACK ALREADY OFF FOR BLEED TRIP OFF. CABIN FOUND AUTO FAIL LIGHT & ALT LIGHT ON, ON CABIN PRESSURE MODULE. PERFORMED BITE TEST OF DCPC IAW FIM 21-31, TASK 801, & RESET CONTROLLER FOR RESET RECOVERABLE FAULTS IAW STSDR CALA2025120811875Battery Pack · inoperativeEMERGENCY LIGHT ABOVE SEAT ROW 12DEF INOPERATIVE. REMOVED UNSERVICEABLE BATTERY PACK AT BATTERY SUPPLY UNIT M1695 IAW AMM 33-51-06. INSTALLED SERVICEABLE BATTERY PACK IAW AMM 33-51-06. PERFORMED OPS TEST OF NEW SERVICEABLE BATTERY PACK IAW AMM 33-51-06, SUSDR CALA2025120511801Battery Pack · inoperativeFIRST CLASS EEPL LIGHTING AND R1 DOOR EMERGENCY LIGHTING INOP. SUPPORT TASK NSA EMX N/R 00159. REMOVED FWD ENTRY PANEL IAW AMM 25-21-71-000-807 SUBTASK 25-21-71-010-010. REMOVED BATTERY PACK AT BATTERY SUPPLY UNIT M1674 IAW AMM 33-51-06. INSTALLED SERVICEABLSDR CALA2025120411765Attach Angle · crackedSTATION 663 VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT APPROXIMATELY LBL 9.0. REPAIRED BS 663 VAPOR BARRIER UPPER ATTACH ANGLE IAW SRM 57-10-10-2R-5.SDR CALA2025120411756Attach Angle · crackedBS 663 VAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT APPROX RBL 9.0. REPAIRED BS 663 VAPOR BARRIER UPPER ATTACH ANGLE IAW SRM 57-10-10-2R-5.SDR CALA2025120411754Fitting · crackedSHEAR FITTING AT BS 540, RBL 15.04 CRACKED. REMOVED AND REPLACED THE SHEAR FITTING IAW SRM 51-40-02, & DWG 111A2000 REV ORIGINAL.SDR CALA2025120411752Fitting · crackedSHEAR FITTING AT BS 540, LBL 15.04 CRACKED. REMOVED AND REPLACED THE SHEAR FITTING IAW SRM 51-40-02, & DWG 111A2000, REV ORIGINAL.SDR CALA2025120411749Fitting · crackedSHEAR FITTING AT BS 540, LBL 40.87 CRACKED. REMOVED AND REPLACED THE SHEAR FITTING IAW SRM 51-40-02, & DWG 111A2000, REV ORIGINAL.SDR CALA2025120411747Fitting · corrodedSHEAR FITTING AT BS 540, LBL 32.40 CRACKED. REMOVED AND REPLACED THE SHEAR FITTING IAW SRM 51-40-02, & DWG 111A2000, REV ORIGINAL.SDR CALA2025120411745Fitting · crackedSHEAR FITTING AT BS 540, LBL 6.14 CRACKED. REMOVED AND REPLACED THE SHEAR FITTING IAW SRM 51-40-02, AND DWG 111A2000, REV ORIGINALSDR CALA2025112711508Stringer · crackedINSIDE FUEL PANEL 532RB STRINGER U9 HAS A CRACK IN END OF STRINGER AND APPEARS TO END IN FASTENER HOLE. REPAIRED L/W U9 STRINGER END IAW UAL ECRA 5720-03581 REV ORIGINAL USING FASTENER OPTION C AND UAL AVO INT-11172025-0411-1 WITH NO DEVIATIONSSDR CALA2025112411412Light · no discrepancyEMERGENCY LIGHTS - OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - RH AFT OVERWING EMERGENCY LIGHT INOP. PERFORMED OPERATIONAL TEST OF EMERGENCY LIGHTS IN REF TO AMM 33-51-00. RH AFT OVERWING EMEGENCY LIGHT FUNCTIONS PROPERLY. NO FAULTS FOUND. OPS CHECKSDR CALA2025111811292Support Beam · wornRIGHT A/C PACK BAY OUTER CHORD DAMAGED FROM FWD PACK BAY DOOR LATCH. COMPLETED STEPS 1 -4.E OF SRM REPAIR 57-10-13-2R-3, REMOVED TRIM, CUT DAMAGE AROUND STRIKER PLATE AND DAMAGE TO LOWER CHORD. ACCOMPLISHED OPEN HOLE ROTO PROBE INSP TO ALL INITIAL FASTENER HSDR CALA2025111411220Battery Pack · dischargedEMERGENCY LIGHTS OVER SEAT ROWS 32 AND 36 DEF INOP. SUPPORT TASK NSA EMX NR 00051. REMOVED UNSERVICEABLE BATTERY PACK PN AD-D717-01-100 SN 179187 A T BATTERY SUPPLY M1899 AND INSTALLED SERVICEABLE BATTERY PACK PN AD-D717-01-100 SN 371771 IAW B737-900 AMM 33-51SDR CALA2025111411212Attach Angle · crackedVAPOR BARRIER UPPER ATTACH ANGLE IS CRACKED AT STATION 663 LT SIDE AT APPROXIMATELY LBL 9.0. REPAIRED VAPOR BARRIER UPPER ATTACH ANGLE AT STATION 663 AND LBL 9.0 IAW SRM 57-10-10-2R-5.SDR CALA2025111011043Fitting · crackedSHEAR FITTING AT BS 540 AND LBL 15.04 IS CRACKED. REMOVED AND REPLACED SHEAR FITTING AT BS 540 AND LBL 15.04 IAW SRM 51-40-02 AND DWG 111A2000 REV ORIGINALSDR CALA2025111011041Fitting · crackedSHEAR FITTING AT BS 540 AND RBL 15.04 IS CRACKED. REMOVED AND REPLACED SHEAR FITTING AT BS 540 AND RBL 15.04 IAW SRM 51-40-02 AND DWG 11A2000 REV ORIGINALSDR CALA2025111011039Fitting · crackedSHEAR FITTING AT BS 540 AND RBL 32.40 IS CRACKED. REMOVED AND REPLACED SHEAR FITTING AT BS 540 AND RBL 32.40 IAW SRM 51-40-02 AND DWG 111A2000 REV ORIGINALSDR CALA2025110911009Power Supply · inoperativeOVERHEAD BIN EMERGANCY LIGHTS INOP AT ROW 32 AND 35 REQUESTING MEL 3315A MEL 3315A TOMC REJECTING, EMERGENCY LIGHTS CANNOT BE OUT ADJACENT TO EACH OTHER. RELAMPED OVERHEAD BIN EMERGANCY LIGHTS ROW 32 AND 35, NO HELP. C/W DDP 3315A RELAMPED LIGHTS AS PRECAUTIOSDR CALA2025110610975Window Frame · crackedTHIRD LOWER HOLE ON L3 WINDOW SHOWS A CRACK INDICATION AFTER PRE-COLD REAM. 0.297" REPAIR ACCOMPLISHED ON NR - 003009272. THE L3 WINDOW POST E-F,SDR CALA2025110210820Skin · crackedPOSSIBLE DAMAGE FOUND ON APU HINGE POINT. DAMAGE IS REFER TO SRM 53-00-01 , TWO CRACKS & EDGE DAMAGE BEYOND LIMITS OF 0.150" , OUT OF ALLOWABLE LIMITS. REMOVED FASTENERS AT DAMAGED AREA IAW SRM 53-80-01-2R-1 STEP 4.A. REMOVED DAMAGED SKIN IAW SRM 53-80-01SDR CALA2025102710594Unknown · odorBURNING SMELL COMING FROM AFT GALLEY. NO SMOKE SEEN BUT FUMES A RE STRONG RAN ALL AFT GALLEY APPLIANCES (COFFEEMAKER, OVENS, WARMERS). RAN APU WITH BOTH PACKS ON HIGH. NO SMELL DETECTED. INSPECTED AFT CARGO PIT AND APU COMPARTMENT. NO SMELL DETECTED. FA'SSDR CALA2025102210403Potable Water · contaminatedWATER HAS STRONG CHEMICAL SMELL AND TASTE REF FIM 38-10 TASK 810 DUMPED AND FLUSHED POTABLE WATER. SMELL IS NO LONGER. ACFT OK FOR SERVICESDR CALA2025102110360Lamp · inoperativeEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. EXTERIOR RT AFT OVERWING BOTH LIGHTS NOT WORKING REPLACED R/H AFT SLIDE OVERWING LAMP, OPS CHECK GOOD REF AMM 33-51-04SDR CALA2025101309931Light · detachedEMERGENCY LIGHTING SYSTEM OPS CHECK, FOUND PATHWAY LIGHT DETACHED FROM UNDER SEAT 25,C. IT WAS ILLUMINATED DURING LIGHT TEST. REPLACED PATHWAY LIGHT HOLDER. SECURED IN PLACE. PTHWAY LIGHTS ALL ILLUMINATED WHEN TESTED.SDR CALA2025100709716Girt Bar · out of limits1R DOOR SLIDE GIRT BAR CLOTH IS LOOSE DRAGGING ON FLOOR. MEASURED SLACK WITHIN LIMITS PER AMM 25-66-01-400-801.SDR CALA2025100709715Girt Bar · out of limitsDOOR 1R GIRT BAR EXCESSIVE MATERIAL INSPECTED R1 DOOR SCAPE SLIDE GIRT BAR REF. AMM 26-66-01-000-804 NO DAMAGE OR FAULT NOTEDSDR CALA2025100609611Bumper · faultedOVERWING EXIT SEAT ROW 15ABC, RED EMERGENCY ESCAPE LIGHT BROKEN THROUGH AND INSIDE THE BUMPER ASSY. R & R SEAT 15C BUMPER ASSY PER PINNACLE CMM. EMERGENCY LIGHT OPS CHK OK. PARTS USED: 29-2500-3-0199, QTY :1SDR CALA2025100209524Unknown · odorCLEANERS REPORTED A FOUL ODOR THROUGHOUT THE ACFT, CANT SMELL FOUL ODOR AT THIS TIME. OKAY TO CONTINUE.SDR CALA2025093009445Anti-Ice Valve · faultedCOWL ANTI-ICE NR 2 ENG ILLUMINATED AT FL390. QRH FOLLOWED. LIGHT STILL ON. ON ARRIVAL OVERHEAD FAULT LIGHT FOR E2 ANTI-ICE VALVE EXTINGUISHED. IAW AMM 30-21-11/401 REPLACED COWL ANTI ICE VALVE AS PRECAUTION. ENGINE IDLE LEAK CHECK GOOD. BONDING TEST GOOD ATSDR CALA2025092509248Slide · out of alignmentON INSPECTION, FOUND L2 DOOR SLIDE PROTRUDING OUT OF MOUNTED POSITION. VIEW FROM UNDER DOOR WITH SLIDE INSTALLED, BALL END OF LOWER FITTING OF SLIDE COVER IS SECURED IN DOOR SUPPORT FITTING. A GAP OF 1.25 BETWEEN SLIDE COVER AND DOOR. NO GAPS FOUND ON ALL OTHSDR CALA2025091508868Light · burnedSEAT 3B EMERGENCY EXIT LIGHTING BURNED. REPLACED SEAT 3B AFT EMERGENCY EXIT PATH LIGHTING REF AMM 33-51-14-960-802 OPS CHECK SAT.SDR CALA2025090808570Tru · dirtyACRID/OZONE BURNING SMELL NOTICED BY ALL CREW MEMBERS ON ENTRY TO AIRCRAFT. TRU COVERED IN DUST, PERFORMED AMM 05-51-26-800-801-C1 PART C. COULD NOT SMELL ANYTHING THROUGH OUT CABIN, ONLY SMELLED A LITTLE IN THE FLT DECK AND E&E. INSPECTED FLT DECK AND E&E TSDR CALA2025090508526Doubler · mechanic errorWHILE REMOVING DOUBLER FASTENERS ONE MISDRILL OCCURED. IT MEASURES .5" FROM REAR EDGE OF NEW HOLE TO FWRD EDGE OF EXISTING HOLE STEPS 1 AND 2 PREV COMPLIED WITH ON LP 6014630. COMPLIED WITH STEP 3 OF AVO 15416. REQ HFEC FOR STEP 4. PERFORMED HFEC SURFACE & EDSDR CALA2025090508510Skin · crackedREF ECRA 5330-07602 NEED TO COMPLETE SDR/SFR FOR REPAIR. COMPLETED SDR AND SFR. REQ INSP BUYBACK SFR/SDR DOES NOT REQUIRE IDT OR RII INSPECTION BUY BACK REF GMM 09-10-05 AND 09-25-05 SDR AND SFR COMPLETED AND DOCUMENTED FOR LP 6034876. NFA NEEDED AT THIS TIME SDR CALA2025090408467Lavatory · odorFWD LAV RANCID SMELL POSSIBLY FROM DRAINS. FLUSHED TOILET AND SINK DRAINS WITH SANI/CLEANER FLUIDS. NO LEAKS OR SPILLAGE AROUND DRAINS/FLOOR. OK TO CONTINUE SERVICE.
Back to Boeing 737-924