Boeing 737-924ER
Service difficulty reports · 3,682
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025121512135Unknown · odorF/A IN THE AFT REPORTED SMELLING FUMES FROM THE PACK AIR ON LA NDING ATTACHING PIC OF SMOKE/ODOR QUESTIONAIRE FILLED OUT BY CABIN CREW. PERFORMED AMM 05-51-26-800-801-C1 INITIAL INSPECTION FOR ODOR AND OPS CHECKS OF PACK SYSTEMS WITH APU AND ENGINES ISOLATSDR CALA2025121212049Lamp · inoperativeEMERGENCY LIGHTS - OPS CHECK EMERGENCY LIGHTS OPS CHECK - EXTERIOR AFT SLIDE LIGHT INOPERATIVE REMOVED AND REPLACED AFT SLIDE SLIDE/OVERWING LIGHT - LAMP. OPS CHECK GOOD. REF AMM 33-51-04-960-801.SDR CALA2025121512136Control Unit · faultyLIGHT ON EMERGENCY EXIT DOOR 21F FLASHING. NEEDS REPLACED VERIFIED LIGHT FLICKERING AT EXIT ROW 21F. OPENED AND COLLARED C/B ON THE P92 PANEL. VERIFIED EMERGENCY EXIT LIGHTING OPERATES NORMALLY. REQ MEL 3302B. TOMC APPROVED C/W MEL 3302B. PLACARD APPLIED. NO SDR CALA2025121212078Drain · cloggedLAVATORY IS SHOWING FULL WITH POTABLE WATER FULL, LAV SERVICED AT 1329 LCL IAW FLIGHT FEED VERIFIED LAV SERVICE. WASTE ITANK IS EMPTY. VERIFIED LAV OPERATION WITH NO LEAKS. REQUEST MEL 3802F. TOILETS FLUSH NORMALLY. NO LEAKS NOTED - TOMC APPROVED PLACED LAV SDR CALA2025121212077Anti-Ice Valve · faultedUPON APPLICATION OF T/O THRUST RT ENG COWL ANTI- ICE AMBER LIGHT ILLUMINATED. R & R OF NR 2 COWL ANTI ICE VALVE, RT ENG ANTI-ICE VALVE REPLACED. OPS CHECK OK IAW AMM 30-21-11.SDR CALA2025121212062Coffeemaker · odorACRID SMELL AND VISIBLE SMOKE & HAZE IN AFT GALLEY /LAST 2 PAX ROW S. CHECKLISTS RAN, DIVERTED. DEBRIEFED INBOUND FLIGHT CREW. CREW NOTED HAZE IN AFT OF AIRCRAFT CABIN, AND ODOR WAS NOTABLY WORSE WHEN LT PACK SWITCH WAS PLACED IN AUTO DURING FLIGHT. REMOVEDSDR CALA2025121112023Skin · dentedDENT AT FUSELAGE SKIN 4 INCHES FWD OF BS 500I, S23L & 24L. REPAIRED DAMAGED SKIN FROM BS 500H - 500J, S22L - 25L IAW EC/RA 5330-07667 AND AAR-MIA ESR-WI 2024153-2-13305.SDR CALA2025121112021Skin · dentedDENT ON AFT, LEFT OF NLG DOOR. VERIFIED MEASUREMENTS WITH INSPECTION SHOWING: D= 0.201" X L 6.300" X W= 3.900", JUST AFT OF BS 294.5 & IS OUT OF LIMITS IAW SRM 53-00-01-1A-1. REPAIRED DAMAGED FUSELAGE SKIN FROM BS 277 - 320, RBL 15, STR 25L IAW EC/RA 5310-087SDR CALA2025121011986Skin · corrodedCROWN SKIN BS 727C - 727F, S3L-S4R FOUND WITH CORROSION & SCRATCHES. SKIN BS 727C - 727F, S3L-S4R REPAIRED IAW ECRA 5331-03190, REV A.SDR CALA2025120911962Smoke Detector · false activationLAV E SMOKE DETECTOR WENT OFF PER FAS NO PAX IN LAV COULD NOT FIND FAILURE WITH AFFECTED SMOKE DETECTOR, SMOKE DETECTOR PASSES SELF TEST AND SMOKE TEST IAW AMM 26-14-00/501. NO SMOKE ODOR PRESENT, VERIFIED NO TAMPERING WITH SMOKE DETECTOR. OK TO CONTINUE NO NSDR CALA2025120911934Screw · looseL2 GIRT BAR HOLDER, CUT OUT IS NOT SECURED TO GROUND. REPLACED 3 SCREWS REF 51-40-02 SECURE.SDR CALA2025120811901Light · inoperativeFOUND EMERGENCY PATHWAY LIGHTS INOPERATIVE, ROWS 14 & 26. REMOVED AND REPLACED EMERGENCY PATHWAY LIGHTS AT SEAT 26 AND 14 IAW CMM 25-23-55, OPS CHECKED GOOD.SDR CALA2025120811824None · noneROW 39 EMERGENCY CHECKLIST OUT OF DATE ROW 39 EMERGENCY CHECKLIST OUT OF DATE WAS CONFUSED FOR DATE CHECKED. FOUND EMERGENCY EQUIPMENT TO BE SERVICEABLE.SDR CALA2025120711819Engine · odorROTTEN ODOR FROM PACK SYSTEM, BELOW 19000 FEET WC 29-0572-8-0107 INSP EA 7200-02341, NR 1 ENGINE CORE WASH WAS PERFORMED ON ENGINE 1. RESULTING IN ODOR. NO OTHER HISTORY NOTED OK TO CONTINUE.SDR CALA2025120811925Structure · damagedBIRD STRIKE ON RIGHT SIDE OF AIRCRAFT ALT-1000. 190KTS. PERFORMED BIRD STRIKE INSPECTION IAW AMM 05-51-18, FOUND DAMAGE TO NR 7 LEADING EDGE SLAT. INSPECTED ALL ATTACHMENT POINTS AND HARDWARE FOR SLAT NR 7, NO DEFECTS NOTED. INSTALLED NR 7 LEADING EDGE SLATSDR CALA2025120511784Battery Pack · faultedOVERWING EMERGENCY EXIT LIGHTS FLICKERING DURING FLIGHT. DEBRIEF INBOUND CREW HEAD FLT ATTENDANT. STATED RT FWD DOOR EXIT LIGHT (L1063) CAME ON ON TAKE OFF ONLY . FROM SITTING POSITION, ABLE TO SEE CENTER CEILING EXIT SIGN COME ON & ALSO FWD & AFT RT OVERWINSDR CALA2025120411775Valve · faultedOVERWEIGHT LANDING. ESTIMAETED LDG WEIGHT 167.3. NO HARD TOUCH DOWN OR LANDING ROLL ISSUES. AFTER TAKEOFF, GEAR HANDLE WOULD NOT GO UP. CREW PULLED OVERRIDE LEVER & GEAR RETRACTED WITH NO WARNINGS. CREW CONT CLIMB & AS ACFT ACCELERATED FLAPS RETRACTED. AT FSDR CALA2025120411770Wire · chafedOPERATIONAL CHECK OF EMERGENCY LIGHTS, ROW 2 AB FWD EMERGENCY LIGHT INOPERATIVE, CHAFED WIRE. REMOVED AND REPLACED EPL IAW DWG 998525, AND CMM 25-23-52, OPS CHKD GOOD.SDR CALA2025120411763Battery Pack · faultedEMERGENCY EXIT LIGHTS AT ALL OVERWING EXITS ARE FLASHING ON AND OFF. REPLACED BATTERY PACK AT ROW 20F IAW AMM 33-51-06-960-806, LIGHT AT RIGHT SIDE EMERGENCY LIGHTS CHECK GOOD.SDR CALA2025120411772Slide · no discrepancyEXCESS SLIDE APRON TOUCHING FLOOR ON RIGHT SIDE. RESECURED APRON ON R1 DOOR IAW AMM 25-66-00-710-801, NO DEFECTS NOTED, OK TO CONTINUE. VERIFIED R1 SLIDE DOOR REINSTALLATION IAW AMM 25-66-00-710-801.SDR DALA2025120208787Battery Pack · inoperativeAFT GALLEY RT EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED AFT GALLEY BATTERY PACK M1672 IAW AMM 33-51. OPS CHECKED GOOD.SDR CALA2025120211684Battery Pack · dischargedEMERGENCY BATTERY PACK M1675 WAS INOPERATIVE. REMOVED AND INSTALLED EMERGENCY BATTERY PACK M1675 IAW AMM 33-51-06-960-805. OPS CHECK GOOD.SDR CALA2025120311741Lamp · inoperativeR1 EXTERIOR EMERGENCY LIGHT INOPERATIVE. REPLACED THE LAMPS FOR EMERGENCY LIGHT IAW AMM 33-51-04 -960-801. OPS CHECKED GOOD.SDR CALA2025120311739Frame · gougedAFTER REMOVAL OF THE AFT CARGO FLOOR SUPPORT SHIELD FOUND A GOUGE ON FRAME BS 856, S25R. PERFORMED A REPAIR TO THE FRAME WEB IAW ECRA 5360-02064 ,SDR DALA2025120208788Battery Pack · inoperativeFWD GALLEY EMERGENCY LIGHT BY R1 DOOR INOPERATIVE. REMOVED AND REPLACED M2816 BATTERY PACK IAW AMM 33-51, OPS CHECKED GOOD.SDR CALA2025120211693Transmitter · faultedHYD NR 1 LOW PRESSURE ILLUMINATED ON DEPARTURE PERFORMED INITIAL EVALUATION IAW FIM 29-30 TASK 812. COULD NOT FIND ANY EXTERNAL HYD LEAKS, SYS RESERVOIR INDICATION WAS LOW & HAS FLUID WITHIN THE TRANSMITTER. SERVICED A SYS WITH 1 GALLON OF HYD WITH NO MOVENT SDR CALA2025120211680Channel · corrodedAFT CARGO, FOUND MULTIPLE POINTS OF CORROSION ON LT ZEE CHANNEL, BETWEEN BS 727B - 847, REMOVED, FABRICATED, LOCATED, DRILLED & PERFORMED COUTERSINK ON AFT CARGO BAY LT ZEE CHANNEL BTW 727B TO 847 APPLIED ALODINE, PRIMER AND INSTALLED NEW ZEE CHANNEL IAW SRMSDR CALA2025113011589Light · faultedSEAT (15ABC) MOUNTED EMERGENCY (RED) LAMP NEEDS REPLACED DUE TO INTERMITTEN OPERATION. REMOVED AND REPLACED SEAT (15ABC) MOUNTED EMERGENCY (RED) LAMP, OPS CHECK GOOD, REF AMM 33-51-11. PARTS USED: 99-3350-3-0009, QTY :1SDR CALA2025120211648Floor Support · corrodedAFT CARGO, CORROSION ON RH SHIELD, BTW STA 874 TO 867. REPLACEMENT OF CORRODED FLOOR SUPPORT AFT CARGO, STA 867-874 LBL 20 REMOVED AND REPLACED THE AFT CARGO RH SHIELD, BTW STA 874 TO 867 IAW SRM 51-40-02-0G-0 DWG 146A8127.SDR CALA2025120211644Battery Pack · no testPASSENGER COMPARTMENT EMERGENCY LIGHT BATTERY PACK M2816 FAILS CAPACITY TEST. REMOVED AND INSTALLED NEW BATTERY PACK EMERGENCY POWER SUPPLY POS. M2816, OPS TEST GOOD. IAW AMM 33-51-06-960-805. REMOVED AND INSTALLED NEW BATTERY PACK EMERGENCY POWER SUPPLY POSSDR CALA2025120211638Water Heater · inoperativeWHITE SMOKE IN RIGHT AFT LAV. SMOKE DET WENT OFF TWICE UPON REMOVAL OF RIGHT AFT LAVATORY HOT WATER HEATER, CONFIRMED ELECTRICAL SMELL FROM THE WIRES ATTACHED TO THE HOT WATER HEATER. M&E 59-3813-3-0001 (WATER HEATER) ORDERED AND DELIVERED TO TERM A. INSPECTESDR CALA2025113011583Filter · odorDUE TO SMOKE ODOR ON AFT LAV E, RECIRCULATION AIR FILTERS REPLACEMENT IS REQUIRED BY TOMC REQUEST. REF AMM: 05-51-26-800-801-C1. STEP 1.E(1. B). PLEASE INCLUDE FILTER REPLACEMENT AND INSPECTION COMPLETION ON LP: # 7097376 PRIOR TO SIGN OFF. MATERIAL ADDED. RECSDR CALA2025112811536Clamp · wornSTRONG ODOR AFTER START OF ENG 2. PASSENGERS REPORT DIFFICUTY T O BREATH AND SORE THROAT FOUND BOTH WATER EXTRACTOR FLEX HOSES LEAKING AND ONE CLAMP WORN AND LOOSE. REMOVED AND REPLACED BOTH HOSES AND ASSOCIATED CLAMPS IAW AMM 21-51-14. INITIAL RUN SMELL WAS DSDR CALA2025120111619Skin · nickedLEFT FWD FUSELAGE RVSM CRITICAL AREA AT 5 INCHES FROM FWD EDGE AND 11 INCHES FROM LOWER EDGE FOUND A NICK. REMOVED NICK AT LT FWD FUSELAGE RVSM CRITICAL AREA AT 5 INCHES FROM FWD EDGE AND 11 INCHES FROM LOWER EDGE REF SRM 51-10-02-0G-0, ORIGINAL THICKNESS: 0.SDR CALA2025120111611Angle · crackedLEFT WING WEB ALONG DEFLECTION CONTROL RIB POSSIBLE CRACK. REMOVED AND REPLACED AT LEFT WING ANGLE WEB ALONG DEFLECTION CONTROL RIB IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0, SRM 51-20-01-0G-0, AMM 51-21--41-370-802, AND IPC 57-50-00-36A.SDR CALA2025113011594Slide · wornDOOR 1L SLIDE GIRT WEBBING MATERIAL IS WORN. PART IN AREA OF DOOR 1L, SLIDE, SLIDE REPLACEMENT IS A RII ITEM PER GMM 09-25-05 REMOVED AND REPLACED L1 SLIDE IN REF AMM 25-66-01. VERIFIED DOOR 1 L REPLACEMENT SLIDE IS CORRECT PER IPC, SAFETYPIN REMOVED & STOWED SDR CALA2025113011593Slide · no discrepancyDOOR 2L EXCESS SLIDE PACK STICKING OUT NEAR GIRT BAR. INSPECTED SLIDE PACK AT DOOR 2L SLIDE PACK GIRT BAR AREA WAS NORMAL NO EXCESS MATERIAL NO DEFECTS NOTED.SDR CALA2025112811554Wire Harness · damagedDURING CABIN WALK THROUGH FOUND EMERGENCY AISLE LIGHTS IN FIRST CLASS INOP. REPLACED POWER SUPLY "BATTERY CHARGER" FOR FIRST CLASS SEAT PROXIMITY LIGHTS IAW AMM: 33-51-06. NO HELP. FURTHER TROUBLESHOTING FOUND "Y" HARNESS OF ROWS 3,4 & 5AB DAMAGED. HARNESS NESDR CALA2025112811542Lamp · inoperativeEMERGENCY LIGHTS OPERATIONAL CHECK - EEL AT ROW 24 IS INOPERATIVE. RELAMPED FLOOR PROXIMITY LIGHT FOR SEAT 24 IAW AMM 33-51-11-960-801. OPS CHECKED GOOD.SDR CALA2025112811541Light · damagedSEAT MOUNTED EMERGENCY LIGHT AT ROW 15ABC PUSHED IN. SWAPPED TO SEAT ROW 24ABC AND PLACED ON MEL 3319E. REMOVED AND REPLACED LAMP ASSY AT 24ABC, OPS CK OK, AMM 33-51-11, OK FOR SERVICE.SDR CALA2025112811570Adiru · faultyFO SPEED AND ALTIMETER BLANK FO 10 SEC. CLIMB CRUISE AND DESCEN T RETRIEVED LST FLT LEG FAULT. FOUND MULTIPLE FAULTS RELATED TO NR 2 ADIRU. PERFORMED ADIRS BITE PER FIM 34-21/801 AND FOUND NO CURRENT FAULT CODES. CHECKED ADIRS LAST FLT FAULTS AND FOUND CODES SDR CALA2025112611486Lamp · inoperativeLEFT GROUND ILLUMINATION EMERGENCY EXIT LIGHT AT BS 727F INOPERATIVE. RELAMPED LT SLIDE EMERGENCY LIGHT AT BS 727F IAW 33-51-04-960-801. OPS CHECKED GOOD.SDR CALA2025120311737Skin · crackedTWO CRACKS SIGNAL NOTED AT STAB RT SIDE HSS 157.10, FIRST CRACK L=0.416 INCH LOCATED TO 9.356INCH FWD FROM AFT SPAR, SECOND CRACK L=0.381INCH LOCATED TO 16.500 INCH FWD FROM AFT SPAR. (PERFORMED PERMANENT REPAIR AT RH HORIZONTAL STAB AT STAB STA 157.10 AND 16.SDR CALA2025112611480Power Supply · inoperativeFOUND EMERGENCY LIGHTS LOCATED AT RH OVERWING EXIT EXTERNAL FUSELAGE AND STOWBIN EMERGENCY LIGHT AT ROW 21DEF INOP. REMOVED AND REPLACED POWER SUPPLY AT M1671, IAW AMM 33-51-06-960-806. TEST CHECKS GOOD.SDR CALA2025120111609Beam · wornLEFT T/E WING DEFLECTION RIB DAMAGED. REPAIRED DAMAGE WEAR AT THE LT WING T/E DEFLECTION CONTROL RIB AND UPPER SUPPORT BEAM TAB IAW SRM 57-51-02--2R-4, ECRA 5751-01223, THIS REPAIR IS A PERMANENT REPAIR ,SDR CALA2025112611494Pitot System · leakingREJECTED T/O FOR IAS DISAGREE REPEAT WRITE UP APPROX 80 KTS REF FIM 31-62 TASK 876. PERFORMED TROUBLESHOOTING FROM STEP A TO STEP E (6) OBERSERVED MX MSG 31-65060. PERFORMED PITOT STATIC SYSTEM FLUSHING IN ACCORDANCE WITH AMM 34-11-00 CAPTS PITOT FOUND TO BE SDR CALA2025112611492Warning Light · false activationDOOR WARNING ANNUNCIATOR IS ON AFT ENTRY AFT ENTRY DOOR LIGHT ON AFTER TAKEOFF. FA MOVED HANDLE TO CLOSED POSITION AND CLEARED THE LIGHT OPEN AND CLOSED AFT ENTRY DOOR AND CONFIRMED DOOR WARNING ANNUNCIATOR LIGHT IS NOT PRESENT.SDR CALA2025112511472Indication Sys · false indicationNO 1 ENG FUEL RAPIDLY DROPPED AFTER SHUTTING OFF CENTER TANK PUMPS PERFORMED FIM 28-41 TASK 814, FQIS BITE GROUND TEST PASSED. SUMPED ALL FUEL TANKS, NO CONTAMINATION FOUND. CHECKED FUEL TANK QUANTITIES USING FUEL MEASURING STICKS, QUANTITY MATCHES FLIGHT DECKSDR CALA2025112511447Module · odorCREW REPORTED STRONG PLASTIC ODOR EMINATING FROM FLOOR AREA BY RUDDER PEDALS AND FWD AVIONICS COMPARTMENT; UNABLE TO PINPOINT ODOR AT THIS TIME BUT SUSPECT STARTING WITH WEATHER/RADAR UNIT LOCATED AT FWD AVIONICS COMPARTMENT. REFERENCE TASK 05-51-26-800-801-C1SDR CALA2025112411411Light · inoperativeEMERGENCY LIGHTS - OPERATIONAL CHECK EMERGENCY LIGHTS OPERATIONAL CHECK - EEL LIGHT OUT ROW 31 NO TIME TO WORK. PLACING SEAT MOUNTED EMERGENCY LIGHT AT SEAT 31E ON MEL 3319E. ROW 31 INDIVIDUAL EMERGENCY ESCAPE PATH MARKING SYSTEM LIGHT INOPERATIVE. MEL COMPLET
Back to Boeing 737-924ER