What was found
EXCESS SLIDE APRON TOUCHING FLOOR ON RIGHT SIDE. RESECURED APRON ON R1 DOOR IAW AMM 25-66-00-710-801, NO DEFECTS NOTED, OK TO CONTINUE. VERIFIED R1 SLIDE DOOR REINSTALLATION IAW AMM 25-66-00-710-801.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EXCESS SLIDE APRON TOUCHING FLOOR ON RIGHT SIDE. RESECURED APRON ON R1 DOOR IAW AMM 25-66-00-710-801, NO DEFECTS NOTED, OK TO CONTINUE. VERIFIED R1 SLIDE DOOR REINSTALLATION IAW AMM 25-66-00-710-801.