duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025072506900Light · faultedEMERGENCY GROUND ILLUMINATION LIGHT INOP AT ROW 25ABC. RELAMPED BULBS. NO HELP. R+R LAMP SOCKET. NO HELP. FOUND PUSH BACK PIN, RESECURE PIN & PERFORM OPS TEST PER AMM 33-51-00-710-801, LIGHT TURNS ONSDR CALA2025072506923Sensor · faultedLAV WASTE TANK INDICATION FLUCUATES WHEN AFT LH LAV FLUSHED CORRECTION BOTH AFT LAVS CAUSES FLUCTIOUATION ON INDICATION. BOTH LAVS FLUSH NORMAL, NO LEAKS NOTED TOMC APPROVED IAW MEL 3802F PLACARD INSTALLED *DM* SEE FIM 38-30 TASK 809, SEE M/L FOR CLS & SEALS ASDR CALA2025072406876Lamp · no testEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. 3B SEAT HAS ONE EMERGENCY LAMP INOP. REPLACED LIGHT ASSY, OPS CHECK GOOD. REF AMM 33-51-00-710-801.SDR CALA2025072406873Battery Pack · no testEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. EMERGENCY LIGHTS NOT WORKING LEFT SIDE ON OVERWING EXIT ROWS. REMOVED AND REPLACED M1694 POWER SUPPLY BATTERY PACK AS REQUIRED IAW AMM 33-51-06-960-805, OPS CHECKED GOOD.SDR CALA2025072406880Slide · damagedDOOR 2L EMERGENCY ESCAPE SLIDE GIRT BAR MATERIAL DAMAGED. REMOVED DOOR MOUNTED ESCAPE SLIDE REF AMM 25-66-01. INSTALLED SLIDE PACK AND COVER PER AMM 25-66-01-400-804 AND AMM 25-66-01-400-803. OK TO CONTINUE.SDR CALA2025072106768Floorbeam · corrodedCORROSION AROUND LAV FITTING AT AFT WET AREA FLOOR BEAM STA 947 RBL 24. FOUND CORROSION OUT OF LIMITS AT MAIN CABIN AFT WET AREA FLOOR BEAM UPPER CHORD STA 947.50 ACCOMPLISHED REPAIR PER EC/RA 5370-01183 AND AAR ESR# 16-12455 REV IR.SDR CALA2025072206830Door · missingPDA 1 WATER SERVICE DOOR DEPARTED AIRCRAFT REF LP 5617677. REQUEST CDL 52E FOR MISSING WATER SERVICE DOOR. CDL 52E REJECTED. INSTALLED SERVICIBLE WATER SERVICE PANEL IN REFERENCE TO AMM 52-49-09. DOOR OPENS AND CLOSES NORMALLY.SDR CALA2025072106785Charger · no testDURING CABIN INSPECTION FOUND THE FWD CABIN IN SEATS EMERGENCY LIGHTS INOPERATIVE IN THE FIRST FIVE ROWS FIRS CLASS SEATS. REMOVED AND REPLACED BATTERY CHARGER FUSE OPS CHECK NORMAL AS PER B737 AMM 33-51-00.SDR CALA2025072106762Web · corrodedCORROSION AROUND G4 GALLEY FITTING AT FLOOR STRUTURE STA986.5+8" RBL 39. REMOVED AND INSTALLED NEW MACHINED WEB FROM STA 986 TO STA 1016 RBL 39" REF B 737-900ER SRM 51-40-02-0G-0 AND DWG # 147A5701.SDR CALA2025072106760Intercostal · corrodedCORROSION AT AFT WET AREA INTERCOASTAL STA 947 RBL 24. CORROSION FOUND OUT OF LIMITS REMOMOVED AND INSTALLED NEW INTERCOSTAL AND 2 EACH NEW CLIPS AT STA 947.50 RBL 24.75 REF SRM 51-40-02-0G-0 , DWG# 147A5650,EC/RA 5370-01183 AND AAR ESR# 16-12455 REV P2SDR CALA2025071806710A/C Pack · inoperativeLT FWD EMERGENCY LIGHT BULB INOPERATIVE. REPLACED BULB.SDR CALA2025071706671Slide · out of position2L DOOR EXCESS SLIDE MATERIAL REMOVED SLIDE AT 2L, REPOSITIONED AND REINSTALLED SLIDE PER AMM 25-66-01-400-401 ACCOMPLISHED RII INSPECTION OF DR 2R GIRT REPACK PER GMM 09-25-05 AND AMM 25-66-01.SDR CALA2025071606618Web · gougedAFT E&E BAY RT WEB GOUGED. REMOVED DAMAGED IAW SRM 51-10-02, VERIFIED MATERIAL LOSS .007 WITH SCRATCH DEPTH GAUGE, 033 MATERIAL REMAINING. REMOVED DAMAGED WEB IAW SRM 51-40-02. HFEC WAS ACCOMPLISHED IAW NDT PART 6-51-00-00, PROCEDURE 16. NO CRACKS NOTED.SDR CALA2025071706669Slide · not seated1R SLIDE PACK APPEARS TO NOT BE SEATED. REMOVED REPACKED AND INSTALLED R1 DOOR SLIDE PACK REF AMM 25-66-01/401. A/C OK FOR SERVICE. RENDER SAFE CHECKLIST C/W. RII INSPECTION OF R1 DOOR SLIDE PACK REINSTALLATION. VERIFIED SLIDE BOTTLE SAFETY PIN REMOVED AND SSDR CALA2025071606628Power Supply · no testEMERGENCY LIGHTING SYSTEM OPS CHECK , ROW 1-5 EMERGENCY EXIT AISLE LIGHTS INOPERATIVE. R & R POWER SUPPLY M2816 IAW AMM 33-51-06-960-806. OPS CHECKED GOOD.SDR CALA2025071606623Heat Exchanger · faultedLEFT PACK INOP DUE TO CONSTANT PACK TRIP AND SMOKE SMELL ON APPROACH SUSPECT ACM FAILURE. THIS SECOND DEF IS IN ACCORDANCE WITH LOG PAGE 5556666 WITH INOP TCV FAILURE ALSO WITH ITEM 21450 MEL2133D. REPLACED LEFT PACK TCV VALVE DUE TO BITE CK FAULT FOR TCV ON ZSDR CALA2025071706667Girt Bar · out of toleranceEMERGENCY ESCAPE SLIDE INSPECTION DOOR 1L GIRT MATERIAL HANGING OUT REINSTALLED GIRT, REINSTALLED GIRT BAR ON J HOOKS REF AMM TASK 25-66-01-400-803, PARA 3.E.1.(E)(F)SDR CALA2025071506594Bleed Valve · faultedAIR CONDITIONING VALVES RIGHT BREAKER TRIPPED REF SSM 36-11-11-103 SH. 2 AIR CONDITIONING BLEED AIR VALVES RIGHT C.B. B7 ON P6-4 PNL PROVIDES POWER TO ENG 2 BLEED AIR REGULATOR M1180. RESET C.B. & WITH RIGHT ENG RUNNING CYCLED #2 ENG BLEED AIR SWITCH, CIRCUITSDR CALA2025071506590Slide · out of positionDOOR 2L HAS EXPOSED SLIDE MATERIAL HANGING OUT THE BOTTOM OF DOOR. RETUCKED EXCESS MATERIAL REF AMM 25-66-01SDR CALA2025071406516Skin · dentedDENT FOUND AT APPROXIMATELY BS 951 THE 5 OCLOCK POSITION. JUST AFT OF WATER SERVICING PANEL. AFT CARGO RH SIDEWALL PANEL # 142VW REMOVED FOE ACCESS, REF AMM 25-52-06-400-801, DRW T29-0620-1-0069. REMOVED AFT CARGO FLOOR PANEL #140DF REF:AMM 25-52-10-400-801, SDR CALA2025071606632Bracket · looseDOOR 1R SLIDE COVER BRACKET LOOSE. ADJUSTED BRACKET TENSION OF GIRT BAR RETAINER. BAR SNAPS SECURLY INTO PLACE. OPS CHECK OKSDR CALA2025071606631Warning Light · false activationDOOR WARNING ANNUNCIATOR IS ON EQUIP VERIFY DOOR IS CLOSED AND LOCKED , APPLY MEL 5203G PERFORMED OPEN THE ELECTRONIC EQUIPMENT DOOR WHEN THE DOOR HANDLE WILL NOT MOVE IAW AMM 52-48-41-010-801 & PERFORMED ELECTRONIC EQUIPMENT ACCESS DOOR INDICATION SWITCH TESSDR CALA2025071406512Floor Support · corrodedFOUND CORROSION AFT WET AREA SUPPORT INTERCOTAL STA 951 RBL 51. (REF AAR N/R 97526756) FOUND CORROSION OUT OF LIMIT, REMOVED AND REPLACED, INSTALLED NEW INTERCOSTAL AT STA 947 TO STA 967 AS PER REF SRM 51-10-02-0G-0.SRM 51-40-02-0G-0, 53-70-51-1A-1 DETAL 4A FSDR CALA2025071406509Seat Track · corrodedFOUND CORROSION AT MAIN CABIN FLOOR L/H O/B SEAT TRACK UPPER CROWN STA 500E LBL 45.5 (REF AAR N/R 97526722) ACCOMPLISHED SEAT TRACK REPAIR AT MAIN CABIN BETWEEN STA 480 TO STA 500E+9,5" LBL 45.5" PER SRM 53-00-52-2R-4 AND DWG#143A5300.SDR CALA2025071406526Smoke Detector · false activationAFT LAV SMOKE DETECTOR ACTIVATED. NO INDICATION OF SMOKE OR FUMES INSPECTED LAVATORY, FOUND STATUS INDICATOR LIGHT ON SMOKE DETECTOR SOLID GREEN, NO SIGNS OF SMOKE, NO ALARM. NO HISTORY OF ISSUE. REF.AMM 26-14-00.SDR CALA2025071406521Motor · faultedSTABILIZER TRIM SWITCHES DO NOT OPERATE TRIM UP AND TRIM DOWN CA PTAIN'S STARTED FIM TASK27-41-TASK 804. PERFORMED STM LOGIC CARD RESET. NO HELP. CHECKED R64 RELAY CKD GOOD. CHECKED FOR PWR AT STM (M1659) PWR AVAILABLE AT PIN 1,2,3 PER FIM. STAB MOTOR NEEDS RESDR CALA2025071406507Frame · corrodedSEVERAL SPOTS CORROSION AT RIGHT INNER CHORD BETWEEN STA 947 TO STA 1016. REF. AAR N/R:97526633 REMOVED CORROSION AT R/H INNER CHORD R2 DOOR BETWEEN STA 947 TO STA 1016 FOUND TO BE OUT OF LIMITS, REMOVED AND REPLACED INNER CHORD FROM STA 892 TO986 IN REF B 737SDR CALA2025071406504Attach Angle · crackedMAIN WHEEL WELL STA 663.75 RBL 7" VAPOR BARRIER UPPER ANGLE CRACK (REF AAR N/R 97526547) REMOVED AND REPLACED MAIN WHEEL WELL STA 663.75 RH VAPOR BARRIER UPPER ATTACH ANGLE PER DWG 111A1000 ,DWG 111A1322 AND SRM 51-40-02-0G-0. REMOVED AND REPLACED MAIN WHEEL SDR CALA2025071106466Angle · corrodedCORROSION AT R1 DOOR CUTOUT FLOOR INNER CHORD. INSTALLED NEW INNER CHORD AT MAIN CABIN R1 DOOR PER SRM 51-40-0G -0 AND DWG# 141A8310. CORROSION FOUND OUT OF LIMITS, REMOVED AND REPLACED INNER CHORD AT MAIN CABIN R1 DOOR STA 259 - STA 360 PER SRM 51-40-02-0GSDR CALA2025071106465Floor Support · corrodedFOUND CORROSION AFT CABIN WET AREA SUPPORT INTERCOSTAL LBL 24.75 STA 947.5. FOUND CORROSION OUT OF LIMITS PER SRM 53-70-51-1A-1 4.A FIG 103, REMOVED AND REPLACED INTERCOSTAL AT CABIN FLOOR STRUCTURE STA 947.5 TO 967 RBL 24.75 IAW SRM 51-40-02-0G-0, DWG 147A56SDR CALA2025071106457Light · brokenECONOMY PASSENGER SEAT EMERGENCY PATH LIGHTING (EPL) ROW 8 L/H, EMERGENCY PATH WHITE LIGHT BROKEN. REPLACED SEAT LIGHT AT ROW 8. LIGHT OPS CHECK GOOD IAW AMM 33-51-11.SDR CALA2025071106463Skin · dentedACCOMPLISH PERMANENT REPAIR AS PER EC/RA 5360-01922 PART 3 AT SEC 46 FUSELAGE SKIN STA 800 BETWEEN S-25R AND S-27R. ACCOMPLISHED PERMANENT REPAIR CATEGORY B AT FUSELAGE SKIN BETWEEN BSTA 787 AND BSTA 807 AND BETWEEN STR-25R AND STR-27L IAW EC/RA 5331-03170, PSDR CALA2025071106462Attach Angle · crackedMAIN WHEEL WELL STA 663.75 LBL 7. VAPOR BARRIER UPPER ANGLE CRACKED. ACCOMPLISHED REPAIR OF LH VAPOR BARRIER UPPER ATTACH ANGLE STA 663 LBL 5 TO LBL20" PER SRM 57-10-10-2R-5.SDR CALA2025071006434Flap System · faultedFLAPS INDICATING 5 WITH FLAPS 40 SELECTED RAN FLAP DISAGREE CHKL ST HAPPENED 2000FT 165KTS PERFORMED FSEU BITE TEST WITH NO FAULTS FOUND, LAST FAULT WAS 94 LEGS OLD, PERFORMED TRAILING EDGE FLAPS PRIMARY CONTROL OPERATIONAL CHECK WITH NO FAULTS FOUND AND PERFOSDR CALA2025070906411Light · detachedEMERGENCY EXIT LIGHT AT 14C HANGING DOWN WITH WIRES EXPOSED. PERFORMED THE INTERIM REPAIR PER PART 1.TAPE APPLIED. REMOVE AND REPLACE EMERGENCY EXIT LIGHT AT 14C, AND END BAY. OPS CHK GOOD AT THIS TIME. IAW CMM 25-23-55.SDR CALA2025071006423Wire · damagedSEAT MOUNTED AISLE EMERGENCY LIGHT AT ROW 10 IS INOP. FOUND DAMAGED WIRE BETWEEN ROW 10 AND 11. REQUESTING MEL. APPLIED PROTECTIVE TAPE REF SWPM 20-10-13. TOMC APPROVED APPLIED PLACARD. *DM* IF UNABLE TO RESOLVE UPDATE LP WITH P/N AND PICS HARNESS P/N RD-FP12SDR CALA2025070906378Check Valve · faultedAD 2020-16-51 HAS BEEN ISSUED TO ADDRESS THE ENGINE BLEED AIR 5T H STAGE CHECK VALVE. C/W 5TH STAGE VALVE INSPECTION ON #1 ENGINE, REPLACED DEFECTIVE VALVE, IAW AMM 36-11-02 AND EA 3611-01438 REV B. COMPLETED VALVE, CHECK, F. THIS ENTRY TO REPORT 5TH STAGESDR CALA2025070806348Skin · damagedLIGHTNING STRIKE FOUND AT STATION 410 BELOW STRINGER 15L - REF L P 5171918 (REF AAR NR 1000048418) ALL WORK PERFORMED ON RFD AAR N/R 1000048418.SDR CALA2025070806347Skin · damagedLIGHTNING STRIKE FOUND ON FASTNER AT STATION 188 AND WATER LINE 220 LH SIDE-REF LP NO.4936294 (REF AAR NR 1000048412). COMPLIED WITH ECRA 5310-08636. MAINTENANCE C/WSDR CALA2025070806346Skin · damagedLIGHTNING STRIKE AT STA 440, STRINGER 9R-REF LP NO.5180618. COMPLIED WITH EC/RA 5330-07558. REPAIR COMPLETED ON ELB 5180618. NO FURTHER ACTION REQUIRED.SDR CALA2025070806315Inlet · contaminatedAPU BLEED AIR EXHAUST SMELL IN CABIN ODOR. T/S REF FIM 49-55 TASK 801. PERFORMED VISUAL INSPECTION OF APU AND FOUND RESIDUAL OIL NEAR AIR INLET DUCT. CLEANED AREA THOROUGHLY AND RAN APU WITH BLEED FOR APPROXIMATELY 1 HOUR. COULD NOT REPLICATE ODOR IN AIR. VERSDR CALA2025071006415Slide · no discrepancy1R DOOR SLIDE NEEDS INSPECTION. EXCESSIVE MATERIAL SHOWN WHEN A RMED MATERIAL NOT EXCESSIVE. NORMAL AMOUNT PF MATERIAL SHOWIMG PER TASK 25-66-01-400-801SDR CALA2025070806312Filter · cloggedDUE TO #1 ENG WASH LAST NIGHT IN SFO. PERFORMED ODOR IN THE CABIN CONDITIONAL INSPECTION PER AMM 05-51-26-800-801-C1. ENG RUNS AND PACK BURNOUT NO ODOR PRESENT. REMOVED & REPLACED LEFT & RIGHT RECIRCULATION AIR FILTERS.SDR CALA2025070806311Sensor · false indicationLAV E VACC WASTE GUAGE READS EMPTY, WHICH ISNT TRUE. ALSO SMELLS LIKE SEWAGE. VERIFIED WITH LAV SERVICES THAT TANK IS EMPTY AND HAS NO LEAKS TOILET OPS CHECK NORMAL, OK TO TOMC APPROVED COMPLIED WITH MEL PLACARD APPLIED. OK TO CONT. INSPECTED AFTER FLIGHT GUASDR CALA2025070706271Coffeemaker · faultedAIRCRAFT GATE RETURNED DUE TO SMELL OF SMOKE IN AFT GALLEY. FLAGGED AS SDR FOR A/R DEBRIEFED FA AND STATED THAT A POPPING SOUND IN AFT GALLEY WAS HEARD AND VISIBLE WHITE SMOKE CAME FROM COFFEE MAKER GRILL AREA (SEE PHOTO) WITH AN ELECTRICAL BURN ODOR. FA OPENESDR CALA2025070706253Lamp · inoperativeL2 DOOR OUTSIDE EMERGENCY LIGHT INOP RELAMPED REF AMM 33-51-00. OPS CHECK GOODSDR CALA2025071406496Crease Beam · corrodedMAIN CABIN L-2 DOOR AREA, INNER CHORD CORRODED ON UPPER SURFACE BETWEEN BS 951 AND BS 986 APPROX. LBL-50. REMOVED AND REPLACED L2 DOOR CREASE BEAM IAW B737-900 SRM 51-40-02 AND 51-40-05 AND BAC DWG 147A8540 ESFR COMPLETED CHANGED RII STATUS REMOVED AND REPLSDR CALA2025071406495Door Sill · corrodedR2 DOOR LOWER SILL AREA, INNER CHORD CORRODED ON UPPER SURFACE BETWEEN BS 951 AND BS 986 APPROX RBL-50. REMOVED DAMAGE, FABRICATED REPAIR PARTS, LOCATED, DRILLED, RESTORED COATINGS AND INSTALLED REF SRM 53-70-15-2R-1 AND 51-70-11-2R-0 THIS IS A CAT A REPAIR SDR CALA2025070706247Slide · out of positionR1 DOOR SLIDE MATERIAL EXCESS SHOWING. DRAGS ON OPENING. ADJUSTED EXCESS SLIDE MATERIAL. DID NOT DRAG ON OPENING. OPS CHECK WITH DOOR GOOD.SDR CALA2025070706237Light · brokenCREW REPORTED ONE AISLE EMERG PATH LIGHT BROKEN. EMERG LIGHT ASSY REPLACED IAW AMM TASK 33-51-11-960-802, OPS CHECK GOOD ACFT OK TO CONTINUE.
Back to Boeing 737-924ER