Boeing 737-924ER
Service difficulty reports · 3,682
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '737924ER' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2025070706279Pump · failedRIGHT CENTER FUEL LOW PRESS ON WITH SWITCH SELECTED ON. 6.4 IN TAN K.REQUEST MEL FOR RT CENTER FUEL BOOST PUMP INOP. PULLED AND COLLARED RT CENTER PUMP C/B. PLACED RT CENTER FUEL PUMP ON M.E.L., DDP C/W. TRANSFERRED FUEL INTO CENTER TANK WITH RT CENTER FUEL SDR CALA2025070706230Elec Connector · disconnected30ABC LOWER AISLE EMERGENCY LIGHT OUT 30ABC FLOOR PROXIMITY LIGHT ASSY REM AND REPL. REF AMM 33-51-11-960-802. LIGHT STILL WONT TURN ON. FURTHER TS REQUIRED. MEL 3319E. CW MEL REQUIREMENTS FLOOR PROXIMITY LIGHT INDICATED ON LOWER AISLE 30ABC WAS FOUND UPON TRSDR CALA2025070706225Unknown · odorFA ADVISED ELECTRICAL SMELL NEAR DOOR R2 SAID IT SMELLED LIKE A HOT CHARGER DEBRIEF CABIN AND FLT CREW. ACCOMPLISHED TAS PER AMM 05--51-26-800-801-C1, PERFOMED RIGHT AFT DOOR HEATER OPS CK PER AMM 21-45-00-700-802 AND NO DEFECTS NOTED NO SMELL, INSPECTED HESDR CALA2025070306182Door · no discrepancyBEFORE EACH DEPARTURE, VERIFY AFFECTED DOOR(S) IS CLOSED, LATCHED AND LOCKED PER MEL CARD 52010 MAINTENANCE PROCEDURE STEP A. - FWD CARGO DOOR HAS BEEN OPENED DUE TO LOADING EXTRA BAGS VERIFIED PER MEL CARD 52010 MAINTENANCE PROCEDURE STEP A.SDR CALA2025070306179Slide · no discrepancyDOOR 2L FA REPORTS SLIDE PRESSURE AT THE GREEN MEETS RED LINE. INSPECTED DOOR 2L SLIDE PRESSURE GUAGE IAW AMM TASK 25-66-01-200-801. SLIDE IND IS WITHIN THE GREEN AND NORMAL AT THIS TIME. A/C OKAY TO CONTINUE.SDR CALA2025070306168Lamp · inoperativeSEAT ROWS 25 AND 35 LEFT EMERGENCY PATH SEAT LIGHTS INOPERATIVE. DEFERRED REF MEL 3319E. M&L FOR LAMPS AS NEEDED REPLACED SEAT ROWS 25 AND 35 LEFT EMERGENCY PATH SEAT LIGHTS IAW AMM 35-51-11. AMM 33-51-11.SDR CALA2025070206147Lamp · inoperativeEMERGENCY EXIT LIGHTS "NOT ARMED" LIGHT NOT ILLUMINATING RELAMPED AS REQUIRED, OPS CHECK GOOD PER AMM 33-12-00-710-001-A.SDR CALA2025070206144Light · damagedECONOMY PASSENGER SEAT EMERGENCY PATH LIGHTING (EPL). FOUND LT ROW 31 EPL LIGHT HOUSEING DAMAGED REPLACED LIGHT LENS IAW B737 AMM 33-51-11. OPS CHECK GOOD.SDR CALA2025063006035Unknown · odorHYD FLUID SMELL ON FLT DECK DESCNDING THROUGH 10500 FEET FLIGHT CREW FILLED OUT SMOKE / FUMES IN THE COCKPIT/ CABIN FORM. CHECKING FOR HYDRAULIC LEAKS, SMELLED HYDRAULIC FUMES WITH BOTH PACKS RUNNING, SMALL WET AREA UNDER KEEL BEAM IN THE BELLY BEACON AND INSSDR CALA2025063006070Fan Cowl · crackedFOUND 2.5 INCH CRACK AT #1 ENG I/B FAN COWL AFT CORNER. (REF AAR N/R 9979368) REPAIRED #1 ENG., I/B FAN COWL , AFT UPPER CORNER, AS PER REF. SRM 54-20-01-2R-13 REPAIR 13 AND EC/RA 7113-01179. REPAIRED #1 ENG., I/B FAN COWL , AFT UPPER CORNER, AS PER REF. SRM SDR CALA2025063006069Fan Cowl · crackedFOUND 2.5 INCH CRACK AT #1 ENG I/B FAN COWL AFT CORNER. (REF AAR N/R 9979368) REPAIRED #1 ENG., I/B FAN COWL , AFT UPPER CORNER, AS PER REF. B737 SRM 54-20-01-2R-13 REPAIR 13 AND ESR # 33-12389 REV IR, WORK ACCOMPLISHED BY V901438 AAR INSP 206 LOGPAGE WAS MADESDR CALA2025063006068Indication Sys · malfunctionedGEAR DID NOT RETRACT. COMPLETED GEAR DISAGREE NON NORMAL CHKLST. GEAR RETRACTED. CREW REPORTED THEY OPENED AND CLOSED THE MANUAL GEAR ACCESS DOOR VERBAL FROM CREW AFTER GEAR HANDLE MOVED TO UP HE HAD 3 GREEN AND 3 RED LIGHTS ON THE FWD PANEL AND 3 GREEN ON THSDR CALA2025063006055Slide · out of position2R SLIDE MATERIAL STICKING OUT AT BOTTOM ADJUSTED DOOR 2R SLIDE FLAP TO NML. REF AMM25-66-01-400-803SDR CALA2025063006053Life Raft · no discrepancyDOOR 2R LIFE RAFT PRESSURE INDICATOR IS RED. DOOR 2RH SLIDE BOTTLE PRESSURE GAUGE VIEWED STRAIGHT ON IS IN THE GREEN BAND HIGH SIDE SERVICEABLE REF AMM 25-66-61.SDR CALA2025063006042Sensor · dirtyPSEU LIGHT ILLUMINATED. FOUND MSG 52-76015 FWD ENTRY DOOR. CLEANED SENSOR AND TEST PASSED. REF FIM 32-09-10-740-801 PSEU LIGHT EXTINGUISHED A/C OK FOR SERVICESDR CALA2025063006032Structure · contaminatedFOUL ODOR SMELL REMAINS IN FWD CARGO COMPARTMENT, FWD GALLEY AND FLIGHT DECK RESIDUAL FOUND IN AFT OF FWD CARGO. REMOVED CONTAMINATED INSULATION AND CLEANED AREA. CURRECTLY AIRING OUT FWD CARGO. REMOVED FWD CARGO FLOOR BOARD INSTULATION. REF AMM 25-80-00. INDSDR CALA2025062706011Director · faultedSTBY ATTITUDE INDIC OSCILLATING BETWEEN 10 DEGREES AND 30 DEGREE NOSE UP AND30 DEGREES REMOVED ISFD UNIT REFMM 34-24-02 FOR IDENTIFICATION,PULLED 3 TOTAL CBS 2 ON P6-3 AND 1 ON ISFD BATTERY IN E & E COMPARTMENT PER MM 34-24-02 REPLACED ISFD AMM 34-24-02, ALL FSDR CALA2025062705996Lamp · burned outDOOR 2 R EMER LIGHT NEEDS RELAMP. RELAMP DOOR 2 RH EMER EXIT LIGHT REF AMM 33-51-01. OPS CHECK GOOD.SDR CALA2025062705981Clamp · no discrepancy1L/1R GIRT BAR CLAMP LOOSE PER FA PERFORMED ESCAPE SLIDE CHECK AMM25-66-01-200-802, INSPECTED BOTH 1L/1R GIRT BAR & J-HOOK , NO DISCREPANCIES FOUND, OPS CHECK GOOD.SDR CALA2025062705980Slide · no discrepancyDOOR 1R SLIDE HAS YELLOW RAFT MATERIAL PROTRUDING FROM BOTTOM. NO DEFECTS NOTED REFERENCE AMM 25-66-00.SDR CALA2025062605889Charger · faultedB737-700/800/900/900ER FLIGHT READINESS CHECK {B737-05-3-0003} - DURING CABIN CHECK FOUND SEAT 1B, 2B, 3B, 4B AND 5B EMERGANCY LIGHT INOP REMOVED AND REPLACED FORWARD POWER SUPPLY REF AMM 33-51-06-960-806. PERFORMED EMERGANCY LIGHT TEST. ALL LISTED SEATS EMERGSDR CALA2025062605914Lamp · burned outEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK. DOOR 2L EXTERNAL EMERGENCY LIGHT INOP. REPLACED THE LAMP, OPS OK IAW AMM 33-51-04.SDR CALA2025062605881Switch · faultedAFT CARGO DOOR LIGHT WILL NOT EXTINGUISH. WHEN AFT CARGO DOOR IS CLOSED AND LOCKED, DOOR LIGHT STAYS ON. NEED TO APPLY MEL 5203A. MEL 5203A REJECTED. ITEM CORRECTED CLEANED CONNECTIONS AT WIRES SWITCH. REINSTALLED SWITCH, OPS CHECK GOOD.SDR CALA2025062605932Pump · faultedIN CLIMB ENG2 HYD LOW PRESSURE LGT ILLUMINATED QRH COMPLIED WIT H AIRCRAFT DIVERTED TO ELP. REMOVED AND REPLACED #2 ENG HYD DRIVEN PUMP COMPLETED STEPS A THRU H REF AMM 29-11-11. COMPLIED WITH REMAINING STEPS FOR #2 ENG EDP INSTALLATION REF AMM 29-11-11. OPSSDR CALA2025062505867Sill Drain · odorOVERWHELMING PUTRID ODOR PESENT THRU OUT ENTIRE CABIN AND COCKPIT. FOWARD CARGO PIT WAS FULL OF FISH ON ARRIVAL FISH WATER / JUICE WAS COMMING OUT OF FUSELAGE DRAIN HOLES SUGGEST MM 51-00-62-200-801 AND AMM 25-52-00-100-801 FOR CLEAN UP AND SMELL REMOVAL REMOSDR CALA2025062505866Unknown · odorSULPHER SMELL COMIG FROM DOOR 2L INSPECTED DOOR 2L SEALS. NO DEFECTS NOTED. ALSO INSPECTED DOOR 2 L AND R SILL DRAINS FOR ODOR, NO ODORS PRESENT AT EITHER SIIL DRAIN. PERFORMED CONDITIONAL ODOR INSPECTION REF AMM 05-51-26-800-801-C1. NO ODOR FOUND. AIRCRAFT OSDR CALA2025062505863Battery Pack · inoperativeRH WING FWD IN EMERGENCY LIGHT INOP. CHANGED THE LAMP , AND THE FUSES, IT DOESN'T HELP, NEED MORE TIME TO T/S PLACED RH WING FWD EMERGENCY LIGHT ON MEL 3314A INFO UPDATE: INOP LIGHT IS RH WING EXTERIOR OVERWING EXIT EMERGENCY ILLUMINATION LIGHT. RELAMPED OVSDR CALA2025062305791Seal · leakingCAPT SIDE WINDOW SEAL MAKING LOUD NOISE DURING CLIMB OUT. WINDOW CLSD BUT WOULD NOT SEAL FOUND WHITE RUBBER SWITCH CAP IN CAPTAIN SLIDING WINDOW TRACK AND GREASE AROUND FORWARD SEAL OF SLIDING WINDOW. REMOVED CAP AND CLEANED SLIDING WINDOW SEAL OF DEBRIS AND GSDR CALA2025062505869Shutoff Valve · bindingNUMBER 1 ENG 9 PSI LEFT BLEED AFTER TAKEOFF PLACARDED #1 ENGINE BLEED PER MEL 3605A, LOCKED #1 PRSOV CLOSED. DISPATCH DESK: 35 TOMC APPROVES PLACARDED #1 ENGINE BLEED INOP PER MEL 3605A, PRSOV NEEDS REPLACEMENT REF AMM 36-11-04. REMOVED AND REPLACED ENG 1 PRSOSDR CALA2025062505861Slide · no discrepancyREMOVED DOOR 2L ESCAPE SLIDE PACK AND INFLATION CYLINDER PINNED IAW AMM 25-66-01-000-801 REF LOGPAGE 5282032 REINSTALLED ORIGINAL SLIDE. REMOVED AND STOWED CYLINDER PIN PER AMM 25-66-01-400-801 C/W RII REQUIREMENTS FOR DOOR 2L SLIDE REINSTALLATION. REF AIPC 25SDR CALA2025062305825Slide · partial deployR1 DOOR SLIDE PARTIALLY DEPLOYED. DID NOT INFLATE FOUND INSTALLED SLIDE IN SERVICABLE CONDITION. REMOVED, REPACKED AND REINSTALLED PER AMM 25-66-01-400-803. VERIFIED REPACKING AND REINSTALLATION OF THE R-1 DOOR SLIDE PER AMM 25-66-01-400-803.SDR CALA2025062305800Coffeemaker · odorF/A REPORT SMELL/TASTE OF CHEMICALS COMING OUT OF COFFEE MAKERS 105 AND 106 FWD GALLEY. PERFORMED OPS CHECK OF FORWARD COFFEE MAKERS REF AMM 25-34-00-700-801-C1. OPS CHECKS NORMAL. NO SMELL OR CHEMICAL TASTE NOTED FROM THE WATER. OK FOR SERVICE. PERFORMED OPSSDR CALA2025062505852Bracket · loose1R GIRT BAR BRACKETS LOOSE. BAR FALLS OUT UPON INSPECTION OF THE 1R GIRT BAR, THE BRACKET IS IN GOOD CONDITION. THE GIRT BAR HOLDER NEEDED MINOR ADJUSTMENT DUE TO GIRT BAR SLIDING IN AND OUT EASILY. RESECURED GIRT BAR AND HOLDER. NO FURTHER MAINTAINCE REQUIREDSDR CALA2025062305802Light · damagedEMERGENCY EXIT LIGHT NEAR ROW 1/CLOSET DAMAGED. REMOVED BROKEN EMERGENCY PROX LIGHT ASSY FROM CMM 25-20-23 FIG 4 ITEM 175. NEW LIGHT ASSY NEEDS SOCKETS CRIMPED TO WIRES, SOCKETS NIS AT STATION. PLUG IS FRONT RELEASE. R&R'D FWD CLOSET AFT PROXIMITY EMERGENCY PSDR CALA2025062005739Unknown · odorODER DETECTED TOP OF CLIMB. FA REPORTS DIZZY AND SICKNESS ODER I N GALLEY SMELL IS RADIATING IN THE FWD GALLEY RIGHT SIDE VENTS OVER BY THE OVENS ACCOMPLISHED AMM 05-51-26, RAN PACKS NO DEFECTS NOTED LOCATED ODOR WAS FROM GALLEY CARTS, CATERING REMOVED CARTS SDR CALA2025061905711Battery Pack · faultedEMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK {B737-33-3-0235} - ROW 8ABC THROUGH 14ABC EMERGENCY LIGHTS INOPERATIVE. REPLACED POWER SUPPLY AND BATTERY PACK. OPS. CK. GOOD. REF AMM- 33-51-06-960-806 AND AMM- 33-51-06-960-805. LOCATION OF POWER SUPPLY AND BATTESDR CALA2025061905722Skin · dentedUPON WALKAROUND FOUND MULTIPLE DENTS AFT OF L1 DOOR INSIDE RVSM CRITICAL AREA APPROX. AT STA 380.REMOVED DAMAGED NICKS AND GOUGES REF SRM 53-30-01-1A-1 PAR 4. DAMAGED AREA AT STA 380 AND BETWEEN STR 16L - 17L. CLEAN UP AREA MEASURED 4" X 3.5" X .125. REF SRM 5SDR CALA2025061905697Handle · out of adjustFLAPS INDICATED 5 WHEN POSITION WAS 15 WITH FLAP HANDLE CREW DEBRIEFED HMCS STATING THE FO AND CA FELT THAT THE FLAPS WERE SET AT 15 WHEN THE FLAPS WERE ACTUALLY SET TO 15. PERFORMED FSEU BITE AND NO FAULTS FOUND ACTIVE OR HISTORICAL CYCLED FLAPS FULL TRAVELSDR CALA2025061705585Latch · faultedFLIGHT CREW REPORTS FLIGHT DECK DOOR WILL NOT LOCK IN AUTO OR MANUAL. FOUND FLIGHT DECK DOOR LATCH "BOLT" TO BE STICKING IN THE OPEN POSITION REPEATEDLY. REMOVED AND REPLACED DOOR LATCH ASSY REF CMM 52-51-02 & AMM 52-52-02. OPS CHK NORMAL.SDR CALA2025061905703Sensor · dirtyFWD ENTRY LIGHT CAME ON AFTER LANDING. COMPLIED WITH MEL. FWD ENTRY DOOR WARNING LIGHT - MEL 5203E ONLY PART A OF DEFERRAL ACCOMPLISHED, NO NEED TO DO PART B *DM* REF. FIM 52-10 TASK 801 FOR FAULT ISOLATION. PERFORMED FWD ENTRY DOOR INDICATION SENSOR TEST (SSDR CALA2025061705593Lamp · inoperativeEMERGENCY EXIT PATH LIGHTS INOP AT SEATS14C AND 15C. REMOVED AND REPLACED EMERGENCY EXIT LIGHT LAMPS AT SEATS 14C AND 15 C REF AMM 33-51-11-960-801. OS CHECKED GOOD.SDR CALA2025061805670Slide · no discrepancyEXCESSIVE SLIDE MATERIAL VISIBLE DOOR 1R OKAY FOR CONTINUED SERVICE , MATERIAL STILL WITININ LIMITS REF AMM 25-66-01 OPS CHECK GOOD AT THIS TIME DOOR 1RSDR CALA2025061805669Girt Bar · no discrepancyTOO MUCH SLIDE MATERIAL SHOWING. FRONT RIGHT DOOR. INSPECTED SLIDE GIRT MATERIAL AND FOUND WITHIN LIMITS, R1 DOOR OPERATES NORMALLY NO FURTHER DEFECTS NOTED.REF AMM 25-66-01.SDR CALA2025061805666Warning Light · false activationDOOR WARNING ANNUNCIATOR IS ON FWD ENTRY ON TOUCHDOWN DOOR LIGHT TRIGGERED. FA PUSHED ON HANDLE AND LIGHT EXTINGUISHED. VERIFIED DOOR CLOSE N OPEN INDICATION OPS CHECK GOOD CLEANED TARGET OK TO CONTINUE REF AMM 52-71-00SDR CALA2025061705588Anti-Ice Valve · faultedLEFT COWL VALVE FAIL CLOSED.FL320 -37C. REMOVED AND REPLACED #1 ENGINE COWL TAI VALVE. OPS CHECK GOOD NO LEAKS. REF AMM 30-21-11.SDR CALA2025061705587Module · faultedF/O PITOT TUBE LIGHT ILLUMINATED IN FLIGHT PER FIM F/O PITOT OR F/O P/S LIGHT IS ON - FAULT ISOLATION REFERENCE: 30-31 TASK 803. REMOVED AND REPLACED WINDOW/PITOT HEAT MODULE PER WINDOW/PITOT HEAT MODULE (P5-9) REMOVAL REFERENCE: TASK 30-41-41-000-801. ALL TESSDR CALA2025061705604Girt Bar · no discrepancyFA REPORTS 2L SLIDE TOUCHING THE FLOOR ADJUSTED SLIDE PACK GIRT BAR MATERAL Z FOLD AT DOOR 2L. SLIDE GIRT BAR MATERIAL WITHIN LIMITS IN REF W AMM 25-66-01-400-804 AND AMM 25-66-01-000SDR CALA2025061705586Outflow Valve · faultedRAPID RISE IN DIFF PRESS URE. CABIN PRESSURE DECREASED INTO NEGA TIVE. REF FIM 21-31 TASK 801 PERFORMED BITE CHECK OF DCPC 1 AND 2. FOUND ACTIVE FAULT ON DCPC 1, CAB PRESS SW ACTIVE MESSAGE. NO FAULTS FOUND ON DCPC 2. REF FIM TASK 21-31 TASK 820 FOR CAB PRESS SDR CALA2025061805656Lamp · inoperativeRT SIDE FWD INTERIOR OVERWING CABIN LIGHT INOPERATIVE AT ROW 20FED. PLACE ITEM ON MEL. ALL OTHER LIGHTS ARE A AVAILABLE. PLACED ON MEL. OK TO CONTINUE. RELAMPED R/H FWD OVERWING WINDOW LIGHT REF AMM 33-21-00-960-806. OPS CHECK GOOD.SDR CALA2025061605564Lamp · inoperativeDURING EMERGENCY LIGHTING SYSTEM OPERATIONAL CHECK R1 DOOR EMERGENCY LIGHT INOP RELAMPED R1 DOOR EXTERNAL EMEGENCY LIGHT REF AMM TASK 33-51-04-960-801. OPS CHECK GOOD.
Back to Boeing 737-924ER