SDR 2006UALA02066Frame · crackedLT BS 1265 NR 1 HOLE FRAME WEB AND INNER STRUCTURE CRACKED. REPAIRED FRAME PER ENGINEERING CHANGE ORDER TASK CARD. SUSPECT PRESSURIZATION CYCLE FATIGUE DAMAGE.SDR 2006UALA02065Stringer · crackedFOUND UPPER DECK STR 10L CRACKED AT BS 460 FASTENER HOLE. INSTALLED REPAIR ANGLE. SUSPECT PRESSURIZATION CYCLE FATIGUE.SDR 2006UALA02064Stringer · crackedFOUND UPPER DECK STR 10L CRACKED AT BS 480 FASTENER HOLE. INSTALLED REPAIR ANGLE. SUSPECT PRESSURIZATION CYCLE FATIGUE.SDR 2006UALA02041Lamp · burned outEMERGENCY LT INOP AT DR 2L SLIDE ILLUM. REPLACED LT ASSY.SDR 2006UALA02040Lamp · burned outEMERGENCY LIGHT INOP AT CEILING ROW 37L AND UPPER DECK CEILING. RELAMPED. CHECKS NORMAL.SDR 2006UALA02039Light · inoperativeFOUND EEL INOP AT ROW 44 LT. REPLACED UNDERSEAT CABLE. OP CHECKED OK.SDR 2006UALA02038Feeder Cable · failedEEL INOP AT AFT GALLEY CROSS AISLE WALL. REPLACED FEEDER CABLE. OP CHECKS OK FOR SERVICE.SDR 2006UALA02042Lamp · inoperativeFOUND EMERGENCY LAMP INOP AT SEAT 4A AND 4F. RELAMPED EEL LIGHTS AT SEATS 4A AND 4F. OP CHECKS OK.SDR 2006UALA02043Light · inoperativeFOUND EMERGENCY LIGHT AT 5R ILLUM WITH SW OFF POS. REPLACED LT ASSY NO HELP. FOUND WIRING PROB. 5R DOOR IS CONSIDERED INOP. FOUND OPEN WIRE W2088-004-20 BETWEEN DX323 PIN-3 AND TB214. REPLACED WIRE W2088-004-20 PER WDM 33-31-61.EMERG LTS OPS CHK NORMALLY.SDR 2006UALA02024Lamp · burned outFOUND EMERGENCY LIGHT INOP AT DR2R SLIDE ILLUM, CEILING ROW 56L AND ROW 17. RELAMPED, OPS NORMAL.SDR 2006UALA02023Lamp · burned outFOUND EEL INOP AT ROW 58L AND SEAT 5J. REPLACED LAMPS. CKS NORMAL.SDR 2006UALA02022Lamp · burned outFOUND EEL INOP DR5L WALL CROSS AISLE. REPLACED LIGHT ASSY. OPS CHK NORMAL.SDR 2006UALA02015Floorbeam · corrodedFOUND UPPER DECK BS 980 RBL 20-30, FLOOR BEAM ATTACH INTERCOSTAL UPPER CHORD CORROSION. CUT OUT CORROSION AREA REF SRM 53-20-51. INSTALLED FILLER & REPAIR ANGLE REF SRM 53-00-51 FIG 201.SDR 2006UALA02007Lamp · burned outAFT REST CREW EXIT EMERGENCY LIGHT INOP. RELAMPED, OKAY.SDR 2006UALA02006Fuse · inoperativeRT SIDE LOWER TWO EMERGENCY LIGHTS INOP. REPLACED FUSE ON BATTERY CHARGER. OP CK'D LIGHTS, OP CK'D NORMAL.SDR 2006UALA01988Light · inoperativeSEAT 5F AFT EMERGENCY LIGHT IS INOP. REPLACED LIGHT STRIP, OP CHECKED OK.SDR 2006UALA01968Feeder Cable · damagedEEL INOP AT LT SIDE LAV 111. SUPPLEMENTAL DATA UPDATE, REPAIRED FEEDER WIRE, OP CHECKS OK.SDR 2006UALA01967Wire · damagedEEL INOP AT LT SIDE AFT GALLEY WALL. REPAIRED FEEDER WIRE, OP CHECKS OK.SDR 2006UALA01963Lamp · burned outEMERGENCY LIGHT INOP AT DR 4R SLIDE ILLUM. SUPPLEMENTAL DATA UPDATE RELAMPED. OPS NORMAL.SDR 2006UALA01962Light · inoperativeWALL EEL INOP AT UPPER DECK AFT MOST WALL. REPLACED LIGHT ASSY. OPS. CKS. NORMAL.SDR 2006UALA01961Lamp · burned outFOUND EMERGENCY LIGHT INOP AT ROW 42L CEILING. RELAMPED. OPS NORMAL.SDR 2006UALA01960Lamp · burned outEEL INOP AT ROW 22L. REPLACED LAMP. OPS NORMAL.SDR 2006UALA01959Wire · damagedEMERGENCY LIGHT INOP AT DR5L AFT CROSS AISLE. REPAIRED FEEDER WIRE, OP CHECKS OK.SDR 2006UALA01945Lamp · burned outEMERGENCY LIGHT INOP AT DR5R SLIDE ILLUM. SUPPLEMENTAL DATA UPDATE REPLACED LAMP ASSY, OK.SDR 2006UALA01944Power Supply · inoperativeEMERGENCY EXIT LIGHT IN CREW REST AREA INOP. SUPPLEMENTAL DATA UPDATE REPLACED EPSU AND BATTERY.SDR 2006UALA01943Power Supply · inoperativeEMERGENCY LIGHT INOP AT EXIT SIGN ABOVE DR5R AND EXIT SIGN IN AISLE NEAR DR5R. REPLACED POWER SUPPLY AND BATTERY. OPS CKS NORMAL.SDR 2006UALA01938Unknown · odorELETRICAL BURNING ODOR AND FUMES FROM UPPER GALLEY AND SMELLED DOWN IN LOWER GALLEY. UTILITY BUSSES OFF, SMELL DID NOT DISSIPATE.SDR 2006UALA01923Light · inoperativeEMERGENCY LIGHT INOP AT SEATS 22H AND 43RH. REPLACED LIGHT ASSY.SDR 2006UALA01912Lamp · inoperativeLEFT EXTERIOR EMERGENCY EXIT WING LIGHT INOP AND EMERGENCY EXIT CEILING LIGHT INOP AT ROW 11. ONE LAMP IN EACH EXIT SIGN BURNED OUT. REPLACED LAMPS. LAMP CHECKED NORMALLY.SDR 2006UALA01911Feeder Cable · damagedEMERGENCY EEL LIGHT INOP AT DOOR 4 LEFT GALLEY WALL CROSS AISLE. REPAIRED FEEDER CABLE. OPS CHECKS NORMALLY.SDR 2006UALA01910Light · inoperativeEMERGENCY EEL LIGHT AT SEAT 3J AFT INOP. REPLACED LIGHT ASSY. OPS NORMAL.SDR 2006UALA01909Fuse · inoperativeRIGHT EXTERIOR EMERGENCY WING EXIT LIGHT INOP. TWO FWD LIGHT ASSEMBLIES. REPLACED FUSE, OPS NORMAL.SDR 2006UALA01908Light · inoperativeLEFT OVERWING EMERGENCY LIGHT TOP 1 LIGHT INOP. RELAMPED EMERGENCY LIGHT, OP CHECK NORMAL.SDR 2006UALA01903Torque Box · puncturedFWD PIT TORQUE BOX AT STA 870 HAS A PUNCTURE ROUGHLY TWO INCH SQUARE. REMOVED DAMAGE, FABRICATED REPAIR WEB AND DOUBLER, PRIMED. REF SRM 51-70-13 REPAIR NR 1. INSTALLED REPAIR REF SRM ON FWD CARGO PIT TORQUE BOX TOP PLATE. AC OK FOR SERVICE. SUSPECT CARGO LOASDR 2006UALA01907Battery Pack · dischargedEMERGENCY LIGHTS IN BUSINESS CLASS LEFT SIDE GO ON AND OFF. REPLACED EMERGENCY LIGHT BATTERY AT DOOR 2L. OPS CHECKED OK.SDR 2006UALA01860Lamp · burned outEEL INOP AT ROW 7 LT AND ROW 4J AFT. REPLACED LAMP AND CABLE.SDR 2006UALA01859Lamp · inoperativeWALL EEL INOP AT CLOSET JUST AFT OF ROW 8 RT. REPLACED LIGHT ASSY. OPS. NORMAL.SDR 2006UALA01858Lamp · burned outEMERGENCY LIGHTS INOP AT UPPER DECK CEILING ROW 12 AND 16. REPLACED LAMP.SDR 2006UALA01857Power Supply · inoperativeEMERGENCY EXIT SIGNS INOP AT MONITOR DOOR 3L AND UPPER LT SIDE MID LAVS. REPLACED POWER SUPPLY. EXIT SIGNS OPS NORMAL.SDR 2006UALA01855Lamp · burned outDOOR MOUNTED EMERGENCY LIGHTS NOT ON AT DOORS R5, 1L, 1R, 5L AND 2L. REPLACED LIGHT ASSY AT THOSE DOORS. RECHARGE OF BATTERY PACKS, DOORS 1L AND 1R. OPS NORMAL.SDR 2006UALA01854Battery Pack · inoperativeDOOR 5L AREA EMERGENCY LIGHT QUICK DISCHARGE. REPLACED BATTERY PACK AND OPS CHECKS GOOD.SDR 2006UALA01853Fuse · inoperativeEMERGENCY LIGHTS INOP AT RIGHT OVERWING 2 EA FWD ASSYS. REPLACED FUSE, LIGHTS OPS CHECK NORMAL.SDR 2006UALA01852Lamp · burned outEEL INOP AT SEAT 46 LEFT. REPLACED LIGHT ASSY. OPS CHECKS NORMAL.SDR 2006UALA01851Lamp · burned outWALL EEL INOP AT CROSS AISLE ON FWD SIDE MID GALLEY AND RT SIDE FWD GALLEY. REPLACED LIGHT ASSY. OPS CHECKS NORMAL. REPLACED LIGHT ASSY. OPS CKS NORMAL.SDR 2006UALA01856Battery Pack · inoperativeRIGHT OVERWING EMERGENCY LIGHT 2 BOTTOM LIGHTS INOP. REPLACED BATTERY PWR SUPPLY. LIGHTS WORK NORMAL.SDR 2006UALA01833Connector · damagedFOUND EMERGENCY EVAC CONTROL CONNECTOR DAMAGED AT DOOR 1R. REPOSITIONED EMERG EVAC CONTROL PANEL PLUG. OPS CHECKS GOODSDR 2006UALA01832Wire · brokenEEL SYSTEM JUMPER CABLE CONNECTOR BROKEN AT SEAT 5A AFT AREA. REPLACED WITH NEW CONNECTOR AND OPS CHECKS GOOD.SDR 2006UALA01818Clevis · corrodedNR 6 FLAP TRACK CLEVIS LUG (OTBD) HAS BORE CORROSION. NR 6 FLAP TRACK CLEVIS LUG (OTBD) CORROSION ON THE INNER SURFACE. CARRY FORWARD ITEM NR 9123 WAS CREATED TO MONITOR CONDITION. BORE HAS FINAL DIA. 1.5030 IN. REPAIR PER KAL FRR 747-UAL-0187 AND EVA-6SDR 2006UALA01815Lamp · burned outFOUND EEL 2A AFT INOP. RELAMPED. OP CHECKS OK FOR SERVICE.SDR 2006UALA01814Lamp · burned outG1A GALLEY LT SIDE WALL EMERG PATH LIGHT INOP. REPLACED GALLEY LIGHT UNIT. OPS CHECKS GOOD.
Back to Boeing 747-422