Boeing 747-422

Service difficulty reports · 9,801

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '747422'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 2006UALA01618Light · inoperativeLT AISLE LIGHTS IN FIRST CLASS AND LIGHT ACROSS FROM DOOR 1L WERE INOP. WHILE TESTING EEL LIGHTS REF CH3713, LEFT AISLE LIGHTS IN FIRST CLASS AND LIGHT ACROSS FROM DOOR 1L WERE INOP . CABLES APPEARED TO BE WATER SOAKED 7 SHORTED OUT. REPLACED WATER SOAKED PAug 19, 2006 · N193UA · Boeing 747422 · Emergency LightingSDR 2006UALA01597Lamp · burned outEEL INOP AT ROW 24 RT, 33 LT, SEAT 54HJK. REPLACED LAMP. ALL EEL LIGHT POSITIONS CHECK OK FOR SERVICE.Aug 16, 2006 · N187UA · Boeing 747422 · Emergency LightingSDR 2006UALA01596Lamp · burned outEMERGENCY LIGHT INOP AT DOOR 5 GALLEY CENTER CEILING AND DOOR 5 GALLEY LOWER WALL. REPLACED LAMP. CHECKS NORMAL.Aug 16, 2006 · N187UA · Boeing 747422 · Emergency LightingSDR 2006UALA01595Lamp · burned outEMERGENCY LIGHT INOP AT DOOR 3L AND DOOR 2R SLIDE ILLUM. RELAMPED, CKS NORMAL.Aug 16, 2006 · N187UA · Boeing 747422 · Emergency LightingSDR 2006UALA01556Light · inoperativeEMERGENCY LIGHT INOP AT DOOR 2R AND 4L SLIDE ILLUM. RELAMPED LIGHT. OP CHECKS OK FOR SERVICE.Aug 9, 2006 · N174UA · Boeing 747422 · Emergency LightingSDR 2006UALA01555Light · inoperativeEMERGENCY LIGHTS INOP AT EXIT SIGN DOOR 1R AFT SIDE AND CEILING ROW 26 RT. RELAMPED LIGHTS. OP CHECKS OK.Aug 9, 2006 · N174UA · Boeing 747422 · Emergency LightingSDR 2006UALA01554Wire · damagedWALL EEL INOP AT CLOSET FLOOR FWD OF LAV 102. WALL EEL INOP: CLOSET FLOOR FWD OF LAV 102. SPLICED FEEDER WIRE, OP CHKS OKAug 9, 2006 · N174UA · Boeing 747422 · Light System WiringSDR 2006UALA01549Light · inoperativeEEL INOP AT 54 LT, 5 RT AND 42 RT. RELAMPED EEL.Aug 8, 2006 · N197UA · Boeing 747422 · Emergency LightingSDR 2006UALA01548Light · inoperativeEMERGENCY LIGHT INOP AT DOOR 2L FWD SILL, ROW 3 LT, ROW 12 CEILING, AND DOOR 5 RT LWR SIDEWALL. RELAMPED ALL. OP CHECKED OK.Aug 8, 2006 · N197UA · Boeing 747422 · Emergency LightingSDR 2006UALA01550Structure · interferenceDOORWAY FRAME TO SILL CLIP INTERFERES WITH FASTENER INSTALLATION AT BS 1810 STR 27R. TRIMMED OUT CLIP & INSTALLED REPAIR ANGLE. INSPECTED REPAIR. WITHIN 15000 CYCLES OF REPAIR INSTALLATION & ACP REPETITIVE INSPECTIONS AT INTERVALS NOT TO EXCEED 3000 CYCLES.Aug 7, 2006 · N175UA · Boeing 747422 · Fuselage Miscellaneous StructureSDR 2006UALA01547Battery Pack · dischargedEMERGENCY EXIT LIGHT INOP AT UPPER DECK RT DOOR AND NUMEROUS SEAT EELS FLICKERING AT UPPER DECK FWD AREA. REPLACED BATTERY PACKS, OP CHECKED OK.Aug 7, 2006 · N175UA · Boeing 747422 · Emergency LightingSDR 2006UALA01546Light · inoperativeEMERGENCY EXIT LIGHT INOP AT UPPER DECK LT EXIT. RELAMPED AND OP CHECKED OK.Aug 7, 2006 · N175UA · Boeing 747422 · Emergency LightingSDR 2006UALA01530Light · inoperativeEMERGENCY LIGHT INOPERATIVE AFT CREW REST STAIRS. REPLACED LIGHT ASSY.Aug 7, 2006 · N198UA · Boeing 747422 · Emergency LightingSDR 2006UALA01529Lamp · inoperativeEMERGENCY LIGHT INOPERATIVE ROW 12 CEILING. RELAMPED. CHECKED OK FOR SERVICE.Aug 7, 2006 · N198UA · Boeing 747422 · Emergency LightingSDR 2006UALA01528Lamp · inoperativeEEL INOP ROW 1L FWD SECTION & ROW 1R AFT SECTION. RELAMPED BOTH POSITIONS. OP CHECKED OK.Aug 7, 2006 · N198UA · Boeing 747422 · Emergency LightingSDR 2006UALA01533Light · inoperativeDOOR 3 RT SLIDE EMERGENCY LIGHT INOPERATIVE. RELAMPED EMERGENCY LIGHT. OP CK NORMAL.Aug 6, 2006 · N199UA · Boeing 747422 · Emergency LightingSDR 2006UALA01532Charger · inoperativeRT OVERWING EMERGENCY LIGHT 2 LOWER LIGHT INOPERATIVE. REPLACED CHARGER, OP CK NORMAL.Aug 6, 2006 · N199UA · Boeing 747422 · Emergency LightingSDR 2006UALA01531Connector · unsecureSEATS 6, 7 & 8 RT EMERGENCY LIGHTS & DOOR 2 RT AFT EXIT ARE INOPERATIVE. SECURED CONNECTOR AT BATTERY. OP CHECKED OK FOR SERVICE.Aug 6, 2006 · N199UA · Boeing 747422 · Light System WiringSDR 2006UALA01527Lamp · inoperativeDOORWAY 4L AFT EEL INOPERATIVE. RELAMPED, OP CHECKED OKAug 6, 2006 · N175UA · Boeing 747422 · Emergency LightingSDR 2006UALA01526Lamp · inoperativeDOOR 1L EMERGENCY EXIT LIGHT INOPERATIVE. RELAMPED, OP CHECKED OKAug 6, 2006 · N175UA · Boeing 747422 · Emergency LightingSDR 2006UALA01525Lamp · inoperativeSEVERAL CEILING EMERGENCY EXIT LIGHTS INOPERATIVE. RELAMPED, OP CHECKED OK.Aug 6, 2006 · N175UA · Boeing 747422 · Emergency LightingSDR 2006UALA01524Connector · overheatedAFT GALLEY PIGTAIL NR 57 OVERHEATED CAUSING DAMAGE TO PIGTAIL AND SMOKE IN AFT CABIN. SMOKE HAS DISSIPATED. REPLACED PIGTAIL ON CART 57. OPS CHECKED GOODAug 5, 2006 · N107UA · Boeing 747422 · Equipment/Furnishings WiringSDR 2006UALA01516Lamp · burned outEEL LIGHTS INOP AT SEATS 54C, 1J & 4A. RELAMPED, OP CHECKED OK.Aug 3, 2006 · N175UA · Boeing 747422 · Emergency LightingSDR 2006UALA01505Lamp · burned outEMERGENCY LIGHT IS INOP AT AFT GALLEY LOWER WALL CROSS AISLE. RELAMPED EMERGENCY LIGHT.Aug 2, 2006 · N194UA · Boeing 747422 · Emergency LightingSDR 2006UALA01504Lamp · burned outEMERGENCY LIGHT INOP AT SEAT 2A FWD & AFT. RELAMPED EMERGENCY LIGHT.Aug 2, 2006 · N194UA · Boeing 747422 · Emergency LightingSDR 2006UALA01497Lamp · burned outEMERGENCY LIGHT INOP AT DOOR 2R FWD, 4R BUSTLE, DOOR 1L AFT, AND 2L AFT. RELAMPED, CHECKS NORMAL.Aug 1, 2006 · N107UA · Boeing 747422 · Emergency LightingSDR 2006UALA01496Lamp · burned outEEL AT ROW 59L INOP. RELAMPED, CHECKS NORMAL.Aug 1, 2006 · N107UA · Boeing 747422 · Emergency LightingSDR 2006UALA01485Lamp · burned outEMERGENCY LIGHT INOP AT ROWS 13, 17 & 18 CEILING AND OVERWING EXTERIOR. REPLACED LAMPS, OPS CHECKS NORMAL.Jul 30, 2006 · N118UA · Boeing 747422 · Emergency LightingSDR 2006UALA01484Lamp · burned outEMERGENCY EEL LIGHT INOP AT SEAT 1J AND SEAT 38 HJK. *S/D* REPLACED EEL LIGHTS, OP CHECK NORMAL.Jul 30, 2006 · N118UA · Boeing 747422 · Emergency LightingSDR 2006UALA01471Light · inoperativeFOUND EMERG LT INOP AT MAIN STAIRS CEILING ILLUM. REPLACED LAMP.Jul 28, 2006 · N117UA · Boeing 747422 · Emergency LightingSDR 2006UALA01470Light · inoperativeFOUND EEL INOP AT MID LAV RT SIDE FWD AISLE. WALL EEL INOP: MID LAV RT SIDE FWD AISLE. ACCOMPLISHED INSTALLATION OF NEW EEL STRIP. OP CKD NORMALLY.Jul 28, 2006 · N117UA · Boeing 747422 · Emergency LightingSDR 2006UALA01453Wire · exposedFOUND GALLEY HOT PLATE LIGHT INOP AT H61. WIRES EXPOSED WITH SOME ELECTRICAL SMOKE. REPLACED HOT PLATE ASSY, AND CLEANED BACK SIDE OF HOT PLATE. NO EVIDENCE OF ELEC BURN FOUND. OPERATIONALLY CHECKED OK WITH NO REPEAT OF SMOKE. WIRES MISROUTED . SUSPECT HJul 23, 2006 · N196UA · Boeing 747422 · Equipment/Furnishings WiringSDR 2006UALA01456O-Ring · failedFOUND DOOR 2R SLIDE BOTTLE PRESSURE IS LOW. SLIDE REPLACED. A/C OK FOR SERVICE. SLIDE PROBLEM ROOT CAUSE IS SLIDE BOTTLE PRESSURE LOW. O-RINGS ON CONNECTIONS TO BOTTLE HARDEN WITH TIME & LEAKED.Jul 22, 2006 · N174UA · Boeing 747422 · Escape SlideSDR 2006UALA01433Relief Valve · stuckDURING OPERATIONAL CHECK OF DOOR 4R POWER ACTUATING SYSTEM AND ESCAPE SLIDE, NR 2 PILLAR DID NOT FULLY INFLATE AND PRESSURE RELIEF VALVE ON RT SIDE STUCK OPEN. ACCOMPLISHED QUALITY ASURANCE OPERATIONAL CHECK OF DOOR 4R POWER ACTUATING SYSTEM AND ESCAPE SLIDE.Jul 18, 2006 · N177UA · Boeing 747422 · Escape SlideSDR 2006UALA01413Lamp · burned outEMERGENCY LIGHT INOP AT DOOR 5L BUSTLE AND CEILING LIGHT AT ROW 16. RELAMPED, OPS OK.Jul 15, 2006 · N196UA · Boeing 747422 · Emergency LightingSDR 2006UALA01382Light · inoperativeTHE FOLLOWING EEL LIGHTS ARE INOP ROW 2A AFT SECTION, CEILING ROW 16, RT SIDE LAV 112. REPLACED LAMPS IN THREE POSITIONS. OP CKED NORMALLY.Jul 12, 2006 · N187UA · Boeing 747422 · Emergency LightingSDR 2006UALA01366Stringer · damagedREMOVED 28 INCHES OF 27L STRINGER AT STA 740 AND FWD, ALONG WITH STRINGER SPLICE AT BUTT SPLICE AND 2 EACH STRINGER CLIPS ON ACCOUNT OF DAMAGE. REPLACED CLIPS.Jul 10, 2006 · N198UA · Boeing 747422 · Fuselage Main, Longeron/StringerSDR 2006UALA01354Skin · ground damageAIRFRAME DAMAGE 65 INCHES FWD OF DOOR 2L AT PRODUCTION SPLICE. DAMAGE STARTS 65" INCHES FWD OF DOOR NR 2 LEFT. SKIN IS PUNCTURED AND STRINGER APPEARS TO BE BENT. REPAIRED FUSE SKIN AND DAMAGED STRINGER PER SRM 53-00-01 & 53-00-03. PERFORMED HFEC INSPECTION OJul 10, 2006 · N198UA · Boeing 747422 · Fuselage Main, Plate/SkinSDR 2006UALA01352Battery Pack · inoperativeEEL LIGHTS INOP AT EMERGENCY WALL AFT OF DOOR 1R ACROSS LAV, ALL SEAT MOUNTED FROM 6GH THROUGH 8GH, BELOW CLOSET JUST AFT OF ROW 8GH, AND AT DOOR 2R FWD GALLEY WALL. REPLACED BATTERY PACK. OPS CHECKS NORMAL.Jul 7, 2006 · N197UA · Boeing 747422 · Emergency LightingSDR 2006UALA01345Lamp · burned outFOUND EEL INOP AT ROW 41, ROW 3, ROW 61, SEAT 1A. RELAMPED. OP CK NORMAL.Jul 6, 2006 · N198UA · Boeing 747422 · Emergency LightingSDR 2006UALA01344Wire · damagedEEL INOP AT AFT GALLEY FLOOR LT CROSS AISLE. REPLACED CABLE. OP CHECKS NORMALLY.Jul 6, 2006 · N198UA · Boeing 747422 · Light System WiringSDR 2006UALA01343Light · inoperativeEMERGENCY WALL EEL INOP BY DOOR 4 LEFT GALLEY CROSS-AISLE. EMERGENCY WALL EEL INOPERATIVE AT DOOR 4 LEFT, GALLEY CROSS-AISLE. REPLACED LIGHT ASSY. OPS. NORMAL.Jul 6, 2006 · N198UA · Boeing 747422 · Emergency LightingSDR 2006UALA01342Light · inoperativeFOUND EEL INOP AT ROW 32 RT. REPLACED CABLE. OP CK NORMAL.Jul 6, 2006 · N198UA · Boeing 747422 · Emergency LightingSDR 2006UALA01340Lamp · burned outDOOR 5 OVERHEAD CREW REST FUSED AISLE EMERGENCY LIGHT INOP. REPLACED LIGHT ASSY AND OPS CHECKS GOOD.Jul 6, 2006 · N193UA · Boeing 747422 · Emergency LightingSDR 2006UALA01339Light · wrong partEEL LIGHTS INSTALLED WRONG AT SEATS 1A, 3A, 7A-B. REPLACED WITH NEW EMERGENCY LIGHTS. OPS CHECKS GOOD.Jul 6, 2006 · N193UA · Boeing 747422 · Emergency LightingSDR 2006UALA01338Wire · damagedCABIN ZONE C LT AFT EEL CABLE DAMAGED. INSTALLED NEW CABLE ASSY. OPS CHECK GOOD.Jul 6, 2006 · N193UA · Boeing 747422 · Light System WiringSDR 2006UALA01337Power Supply · inoperativeEMERGENCY PATH STAIRCASE LIGHTS FLICKERING ON AND OFF. REPLACED BATTERY PACK. EMERGENCY LIGHTS CHECK OK.Jul 5, 2006 · N199UA · Boeing 747422 · Emergency LightingSDR 2006UALA01323Lamp · burned outFOUND EMERGENCY EEL LIGHT INOP AT SEATS 4A FWD AND 5J AFT. REPLACED LAMP.Jul 5, 2006 · N128UA · Boeing 747422 · Emergency LightingSDR 2006UALA01322Wire · damagedFOUND EMERGENCY EEL LIGHT OP AT DOOR 2R WALL AISLE JUST FWD OF GALLEY. REPAIRED FEEDER WIRE. OP CHECKED OK.Jul 5, 2006 · N128UA · Boeing 747422 · Light System WiringSDR 2006UALA01321Lamp · burned outFOUND UPPER DECK CEILING EMERGENCY LIGHT INOP JUST AFT OF ROW 14. REPLACED LAMP.Jul 5, 2006 · N128UA · Boeing 747422 · Emergency Lighting
Back to Boeing 747-422