Boeing 747-422
Service difficulty reports · 9,801
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013031401557Light · inoperativeFLIGHT DECK EMERGENCY LIGHT INOP. RELAMPED, CHECKS OKAY.SDR UALA2013031401556Light · inoperativeCROSSAISLE LIGHT INOP BETWEEN DOOR SL AND 3R. RIGHT POSITION RELAMPED, OPS CHECK OK.SDR UALA2013031301490Cap · missingLEFT VHF ON F/O AUDIO PANEL HAS CAP MISSING. REPLACED F/O`S AUDIO PANEL CAP, CHECKED OK ON GROUND.SDR UALA2013031201466Lamp · inoperativeR5 DOOR SLIDE LIGHT INOPERATIVE. REPLACED LAMPS, OPS CHECKED OKAY.SDR UALA2013031101416Structure · gougedUPPER RUDDER CONTROL MODULE MOUNT TRUNNION LOWER RIGHT ATTACH BORE IS GOUGED AND SCORED. CHIPPED AREA DIMENSIONS, .250 X .150 WITH A DEPTH OF .140. BLENDED GOUGED AREA FROM BOLT THREADS OUT TO .015" OVER FROM .312", DEPTH INTO BORE .312". NEEDS EDDY CURRENTSDR UALA2013031101414Floorbeam · corrodedSTA 1020 LBL 45-RBL 25 UPPER DECK FLOORBEAM UPPER CHORD CORRODED. TEXT SHOULD READ "LBL 45-RBL 45". MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. FABRICATED AND INSTALLED REPAIR.SDR UALA2013031101413Floorbeam · corrodedSTA 1700 BL 0-RBL 24 FLOORBEAM UPPER CHORD CORRODED. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. FABRICATED AND INSTALLED REPAIR IAW SRM 53-60-51 REPAIR 2.SDR UALA2013031101436Wire · exposedAFT GALLEY PIGTAIL P56 WIRE EXPOSED. REPLACED CABLE, OPS NORMAL.SDR UALA2013031101415Light · damagedFOUND EEL ASSY AT LOWER LEFT CORNER OF LAV 101 DAMAGED. EEL LIGHT CHECKS OKAY. SECURED EEL LIGHT CONNECTOR, OPS CHECK OKAY. ACP RII INSPECTION.SDR UALA2013031101435Light · inoperativeEEL FLOOR AT FWD SIDE OF LAV 116 INOP. FOUND OPS NORMAL.SDR UALA2013031101434Light · inoperativeEEL FLOOR AT FWD SIDE OF LAV 117 INOP. OPS NORMAL.SDR UALA2013031101433Light · inoperativeEEL IN DOOR FRAME AT 4L MED (AFT BULB--L1858). RELAMPED, OPS NORMAL.SDR UALA2013031101432Light · inoperativeEEL FLOOR CROSS AISLE ON FWD UNIT OF GLY AT DOOR 2 -- LEFT & RIGHT SIDE EEL INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2013030701378Lamp · inoperativeCEILING EMERGENCY LIGHT AT 20ABC INOPERATIVE. REPLACED LAMPS PER MM.SDR UALA2013030701377Lamp · inoperativeCEILING EMERGENCY LIGHT AFT OF 10AB INOPERATIVE. REPLACED LAMPS.SDR UALA2013030701376Light · inoperativeEMERGENCY LIGHT R4 MED INOPERATIVE. REPLACED EMERGENCY LIGHT ASSY. OPS CHECKED GOOD.SDR UALA2013030701375Bulb · inoperativeEMERGENCY LIGHT R5 MED INOPERATIVE. REPLACED EMERGENCY LIGHT BULBS AND OP CHECKED GOOD.SDR UALA2013030701374Light · inoperativeIN-SEAT EMERGENCY LIGHT AT 48HJK INOPERATIVE. REPLACED SEAT LIGHT AND OPS CHECKED PER MM.SDR UALA2013030701373Light · inoperativeIN SEAT EMERGENCY LIGHT AT 56HJK INOPERATIVE. REPLACED SEAT LIGHT AND OPS CHECKED PER MM.SDR UALA2013030701372Lamp · inoperativeCEILING EMERGENCY LIGHTS BETWEEN ROW 16 & 17 INOPERATIVE. REPLACED LAMPS PER MM.SDR UALA2013030701371Lamp · inoperativeCEILING EMERGENCY LIGHTS AFT OF ROW 14 INOPERATIVE. REPLACED LAMPS PER MM.SDR UALA2013030701370Lamp · inoperativeEMERGENCY LIGHTS AT CEILING BETWEEN ROW 13 & 14 INOPERATIVE. REPLACED LAMPS PER MM.SDR UALA2013030701369Lamp · inoperativeEMERGENCY LIGHTS IN COCKPIT FACING AFT AT FLT DECK DOOR INOPERATIVE. REPLACED LAMPS PER MM.SDR UALA2013030601337Oxygen Bottle · low pressurePAX OXYGEN PRESSURE LOW ON EICAS - 1590 PSI. REPLACED PAX OXYGEN BOTTLE AND INDICATED 1640 PSI. LEAK CHECKED OKAY.SDR UALA2013030601333Door Frame · crackedLEFT NR 3 MED UPPER FRAME CRACKED AROUND GATE HINGE ATTACH HOLES (5 EA). MAJOR REPAIR ACCOMPLISHED. REMOVED FRAME. FABRICATED AND INSTALLED NEW FRAME.SDR UALA2013030701379Smoke Goggles · missingSMOKE GOGGLES FOR 2ND OBSERVER SEAT MISSING. REPLACED MISSING SMOKE GOGGLES FOR 2ND OBSERVER SEAT.SDR UALA2013030501310Valve · faultyRAN GEAR DOOR CHECKLIST AFTER TAKEOFF WITH HANDLE IN OFF POS TO CONCLUSION. LEFT HANDLE IN UP POS. AHM INDICATES R BODY GEAR DOOR ALT PROXIMITY SWITCH FAILED, AND RIGHT BODY GEAR DOOR PRI PROXIMITY FAIL. TROUBLESHOT PROXIMITY SENSOR REF PTT 1872020 AND RESDR UALA2013030401245Wire · broken40H EEL STRIP WIRES BROKEN. REPLACED 40H EEL STRIP, OPS OKAY.SDR UALA2013030401244Selector Valve · faultyHYDRAULIC QUANTITY SYSTEM 4 READS 0 WHEN SELECTED ON GAUGE IN LEFT MAIN LANDING GEAR WHEEL WELL. READING APPEARS TO JUMP BACKWARDS WHEN GOING FROM OFF TO SYSTEM 4. NO AMIS HIS, NO EXISTING FAULTS & FAULT HIS SHOWED SEVERAL HYDIM-4 CARD FAIL (INTERMITTENT). SDR UALA2013030101229Headset · faultyCREW UNABLE TO COMMUNICATE ON VHF. ISSUE STARTED WITH F/O POSITION, HOT MIC PROBLEM. ATTEMPTED RESETS OF AMU AND OTHER COMPONENTS AND PROBLEM SEEMED TO ALSO AFFECT CAPTAIN AND FIRST OBSERVER POSITION. REPLACED F/O HEADSET AND OPS CHECKED GOOD.SDR UALA2013022701192Cover · brokenDOOR 2L ARMING LEVER COVER BROKEN. INSTALLED NEW COVER.SDR UALA2013022701183Skin · damagedFUSELAGE SKIN FORWARD OF AFT CARGO DOOR DAMAGED BY DOOR OPENING STEP. AREA INSPECTED, DAMAGE LENGTH APPROX 8 INCHES LONG ACROSS STRINGER S44R BETWEEN BS 1780 - 1800, BELOW AND FWD OF CARGO DOOR SILL AREA. REPAIR CARRIED OUT IAW SRM 53-00-01 REPAIR 1 ANDSDR UALA2013022601152Structure · damagedDAMAGED AREA AT BS 1780-1800 S44R IAW SRM 53-00-01 PER 51-40-08. DOUBLER AND FILLER MANUFACTURED IAW SRM 53-00-01, TREATED WITH CHEMICAL CONVERSION AND PRIMED. MAJOR REPAIR.SDR UALA2013022601147Skin · damagedFUSELAGE SKIN DAMAGED AT BS 560-580 BELOW STRINGER 27L. CARRIED OUT REPAIR PER SRM 53-00-01 REPAIR 1. REPAIR CLASSIFIED AS CATEGORY 'C' IAW SRM 53-00-01 REPAIR 1 PG 203.SDR UALA2013022601149Skin · dentedLEFT SIDE OF FUSELAGE JUST AFT OF DOOR 1L. AREA INSPECTED 2" DENT FOUND BETWEEN STATION 560 AND 580 BELOW S28L WITH TWO SCRATCHES-GOUGE MARKS APPROX 1.5" AND .5" BETWEEN .030 AND .050 DEEP. REPAIR COMPLETED AS PER SRM 53-00-01 REPAIR 1 PG 202 BLIND FASTENER SDR UALA2013022601166Controller · failedINTERPHONES INOPERATIVE AT 4L, 4R AND 5L, 5R. REPLACED NR 3 LAC PER MM .SDR UALA2013022501130Sill · dirtyDOOR 1R WON`T ARM. CLEANED DEBRIS FROM DOOR SILL DOOR ARMING, OP CHECKS GOOD.SDR UALA2013022501104Doubler · crackedSTA 2517-2521 RIGHT UPPER LOBE DOUBLER CRACKED. MAJOR REPAIR ACCOMPLISHED. INSTALLED UPPER LOBE DOUBLER MODIFICATION PER COA 851103 TASK CARD 891104011.SDR UALA2013022401080Skin · bentDOOR 5L, LWR FWD CORNER FOUND BENT. INSP CARRIED OUT CRACKS RUNNING FROM FASTENER HOLE VERTICALLY UP AND DOWN. VISUAL INSP AND HFEC CARRIED OUT TO CONFIRM CRACKS. REPAIR TO BE CARRIED OUT IAW STRUCTURAL REPAIR MANUAL, REPAIR 9, DOOR OUTER SKIN NON FLUSH REPSDR UALA2013022201059Skin · corrodedEXT FUSELAGE SKIN CORRODED STA 1476 BETWEEN S1L-S2L AND BETWEEN S2R-S3R. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. HFEC FABRICATE AND INSTALL REPAIR PARTS IAW ECRA 5330-04419.SDR UALA2013022201058Skin · corrodedEXT FUSELAGE SKIN CORRODED STA 1476 S8L - S9L. ALSO BETWEEN S12L-S13L AND S16L-S17L. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. HFEC FABRICATE AND INSTALL REPAIR PARTS IAW ECRA 5330-04435.SDR UALA2013022201057Skin · corrodedEXT FUSELAGE SKIN CORRODED STA 1476 S13R - S14R. ALSO BETWEEN S4R-S5R. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE. HFEC FABRICATE AND INSTALL REPAIR PARTS IAW ECRA 5330-04436.SDR UALA2013022101053Light · brokenSEAT 47C SEAT SIDE MOUNT EMERGENCY LIGHT BROKEN. REPLACED SEAT 47C SIDE MOUNT EMERGENCY LIGHT ASSY, OP CHECK OKAY.SDR UALA2013022101043Frame · crackedTENSION TIE FAILSAFE CHORD CRACKED AT 2 FASTENER HOLES, BS 1140 LT. MAJOR REPAIR ACCOMPLISHED. CUT OUT DAMAGED AREA. SPLICED IN NEW SECTION OF FRAME SEGMENT PER SRM 53-40-07, REPAIR 2.SDR UALA2013021900994Light · unsecureEMERGENCY LIGHT LOOSE. SECURED EMERGENCY LIGHT ASSY AND TESTED.SDR UALA2013021901003Conduit · damagedRT BODY GEAR HAS DAMAGED METAL FLEX CONDUIT. COMES FROM JUNCTION BOX J5,CENTER INBOARD CONDUIT, 2ND FLEX CONDUIT. REPLACED DAMAGED SECTION OF CONDUIT.SDR UALA2013021800947Transmitter · failedHYDRAULIC OVERHEAT SYSTEM MESSAGE ILLUMINATED, RETURNED TO FIELD. REMOVED AND REPLACED THE NR 4 HYDRAULIC CASE DRAIN MODULE TEMPERATURE TRANSMITTER PER AM M 29-32-02. REMOVED AND REPLACED THE EDP AND TWO ADP CASE DRAIN FILTERS PER AMM 29-11-18. OPS TESTEDSDR UALA2013021800936Panel · crackedCRACK ON 4 ENGINE PYLON. CRACK IS 2.5 INCHES LONG. REPLACED WITH NEW PANEL PER AMM 54-50-99P801.SDR UALA2013021800925Unknown · malfunctionedHYDIM 4 REMOVED FOR TROUBLESHOOTING. ACCOMPLISHED WIRING CHECK FOR SHORTS PER WDM 29-32-11 AND FOUND NO DEFECTS. REPLACED HYDIM CARD SYS4 A23 PRECAUTIONARY PER MM.SDR UALA2013021800975Extinguisher · unserviceableCOCKPIT FIRE EXTINGUISHER NEEDS SAFETY PIN. SWAPPED FIRE BOTTLE FROM UPPER DECK L JUMPSEAT TO COCKPIT. STOWED INOP BOTTLE IN LOWER STORAGE AT SEAT 14A. REPLACED FIRE EXTINGUISHER.
Back to Boeing 747-422