SDR UALA2011041801890Battery Pack · dischargedLT UPPER DECK DOOR SLIDE ILLUMINATION LIGHTS INOP. INOPED DOOR PER MEL. REF WD & RELAMPED L2927 AND L2930, NO HELP. SUSPECT M7027 NEEDS NEW BATTERY. REPLACED LEFT BATTERY PACK M7027 REF WD, TEST OKAY.SDR UALA2011041801884Connector · not seatedLT EEL LIGHT INOP FROM SEATS 45 TO 53. TROUBLESHOT AND FOUND BAD CONNECTION AT B9129 CONNECTOR. RESEATED CONNECTOR AND OPS CHECKS FINE PER AMM.SDR UALA2011041801869Controller · faulty'APU' EICAS STATUS MSG DISPLAYED. APU AUTO FAULT SHUT DOWN WHILE SW IS IN ON POS, OR SW IN STOP POS AND NO FAULT INDICATION WITH RPM GREATER THAN 95% (APU AUTO EVENT) CREW COMMENTS: APU AUTO SHUTDOWN. REPLACED APU. AFTER APU REPLACEMENT, APU SURGES DURING SDR UALA2011041801866Cover · missing1LT JUMPSEAT EMERGENCY LIGHT SW COVER MISSING. RPL'D SWITCH COVER.SDR UALA2011041801867Charger · faultyAIRCRAFT FAILS DL3387, BATTERY CHARGES AT 27 AMPS. REPLACED CHARGER PER MM AND RERACKED BCU 1 PER MM.SDR UALA2011041801852Light · shortedEMERGENCY LIGHT ON SIDEWALL FWD AND SIDE OF MAIN GALLEY ALONG DR4L INOP. REPLACED SHORTED AND WET EEL.SDR UALA2011041801851Wire · corrodedEMERGENCY LIGHT ROW 45 THROUGH 53 INOP. REPLACED CORRODED AND WET WIRES AT LEFT SIDE ENTRANCE.SDR UALA2011041801849Connector · unsecureEMERGENCY LIGHT SEAT 55 RT INOP. RESECURED LIGHT CONNECTOR. OP CK NORMAL.SDR UALA2011041801848Unknown · odorBURNED ELECTRICAL SMELL IN 'E' ZONE. SET PACKS TO HIGH FLOW AND SMELL DISSIPATED. ACPD CHECK OF AFT CABIN WITH PACKS, RECIRC FANS AND GASPER ON AND WITH ALL OFF, NO SMELL NOTED AT ANY TIME.SDR UALA2011041801853Light · inoperativeOVERWING LT EMERGENCY LIGHT 2 BOTTOM INOP. REPLACED DEFECTIVE TOP LOWER LEFT OVERWING LIGHT ASSY.SDR UALA2011041801850Light · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 14 INOP. RELAMPED, OP CK NORMAL.SDR UALA2011041501835Light · missingEEL STRIP IS MISSING AT 36C. REPLACED LIGHT STRIP PER MM, OPS CHECKS OKAY.SDR UALA2011041501833Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP LOWER WALL ACROSS LAV 100. REPLACED LIGHT ASSY. OPS CKS NORMAL.SDR UALA2011041501832Light · inoperativeEMERGENCY EXIT LIGHT INOP UPPER DECK CEILING AT DOORS FWD LIGHT ASSY. RELAMPED, CKS NORMAL.SDR UALA2011041501831Light · inoperativeEMERGENCY EXIT LIGHT INOP UPPER DECK CEILING ROW 13. RELAMPED, CKS NORMAL.SDR UALA2011041501826Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP LOWER WALL ACROSS LAV 100. REPLACED LIGHT ASSY. OPS CKS NORMAL.SDR UALA2011041501825Light · inoperativeEMERGENCY EXIT LIGHT INOP UPPER DECK CEILING JUST AFT OF ROW 17. RELAMPED, CKS NORMAL.SDR UALA2011041501824Light · inoperativeEMERGENCY EXIT LIGHT INOP UPPER DECK CEILING AT DOORS FWD. LIGHT ASSY. RELAMPED, CKS NORMAL.SDR UALA2011041501823Light · inoperativeEMERGENCY EXIT LIGHT INOP UPPER DECK CEILING ROW 13. RELAMPED, CKS NORMAL.SDR UALA2011041501822Light · inoperativeEMERGENCY EXIT LIGHT INOP IN FLIGHT DECK. RELAMPED, CKS NORMAL.SDR UALA2011041501819Light · inoperativeEMERGENCY LITES DOOR 4R INOP. RELAMPED EMERGENCY LITES AT DOOR 4R, OPS CHECK GOOD PER AMM ON PEMCO NR 2519N00008.SDR UALA2011041501818Light · inoperativeEMERGENCY LIGHT AT DOOR 4L INOP. RELAMPED EMERGENCY LIGHTS AT DOR 4L, OPS CHECK GOOD PER AMM ON PEMCO NR 2519N00007.SDR UALA2011041301791Cable · saturatedEMERGENCY EXIT EEL LIGHTS INOP. SEAT ROWS 45 THRU 53 LEFT, DOOR 4 LEFT FWD EXIT SIGN, DOOR 4 RIGHT AFT EXIT SIGN, LOWER WALL EEL ACROSS DOOR 4 LEFT AND DOOR 4 GALLEY AREA LOWER WALL EEL. FOUND GALLEY FLOOR WET IN LOCATION OF INSTALLED EMERGENCY RIBBON CABLE.SDR UALA2011041301790Wire Harness · defectiveEMERGENCY EXIT EEL LIGHT INOP. SEAT ROW 19 LEFT. REPLACED EEL SEAT LIGHT HARNESS, OPS CHK GOOD.SDR UALA2011041301789Light · inoperativeEMERGENCY EXIT LIGHT INOP DOOR 4 RIGHT SLIDE LIGHT. REPLACED LIGHT ASSY. OPS CKS NORMAL.SDR UALA2011041301788Light · inoperativeEMERGENCY EXIT EEL LIGHT INOP. SEAT ROW 40 RIGHT. RELAMPED EEL LIGHT AT SEAT 40 RT, OPS CHK GOOD.SDR UALA2011041301787Light · inoperativeEMERGENCY EXIT LIGHT INOP. UPPER DECK CEILING ROW 17. RELAMPED. OPS CKS NORMAL.SDR UALA2011041301786Light · inoperativeEMERGENCY EXIT LIGHTS INOP. DOOR 2 GALLEY AREA LOWER WALL CENTER AND RIGHT LIGHTS. RELAMPED LOWER CENTER AND RT EEL LIGHTS IN GALLEY NEAR DOOR 2, OPS CHK NORMAL.SDR UALA2011041101748Fuel/Oil Cooler · leakingON ARRIVAL TO SFO FLIGHT 870-10, NR 2 ENGINE IS STILL LEAKING FUEL ONTO THE RAMP FROM UNDER COWLING. DRY MOTORED NR 2 ENGINE, FOUND IDG AIR-OIL COOLER LEAKING FROM BETWEEN HEAT EXCHANGER AND VALVE BODY AT INBOARD AREA. REMOVED IDG AIR-OIL COOLER ASSEMBLY PERSDR UALA2011041201762Door · damagedRIGHT MAIN BODY, OUTBOARD LOWER LANDING GEAR DOOR DAMAGED. RMV'D MLG OUTBD BODY LOWER DOOR PER MM. REINSTALLED SERVICABLE DOOR. CHECKED DOOR ADJUSTMENT.SDR UALA2011041101745Charger · faultyRT OVERWING EMERGENCY LIGHT 2 TOP LIGHT INOP. REPLACED EMERGENCY LIGHT BATTERY CHARGER, CHECKS NORMAL.SDR UALA2011041101744Light · inoperativeEMERGNECY LIGHT SEAT 57AB INOPERATIVE. RELAMPED, CHECKS NORMAL.SDR UALA2011041101743Connector · saturatedEMERGENCY LIGHT ON FWD AND SIDE WALL OF MAIN GALLEY INOP. GALLEY FLOOR WET IN EMERGENCY ELECTRICAL RIBBON INSTALLED AREA.
DRIED WET AREA OF FLOOR. CLEANED PLUGS WITH CONTACT CLEANER. REINSTALLED ELECTRICAL CONNECTOR. CHECKS NORMAL.SDR UALA2011041101742Connector · saturatedEMERGENCY LIGHT ROW 45 THROUGH 53 INOP. FOUND GALLEY FLOOR WET WHERE THE ELECTRICAL WIRE UNDER THE FLOOR PADDING ARE INSTALLED. DRIED WET AREA OF FLOOR. CLEANED PLUGS WITH CONTACT CLEANER. RE-INSTALLED ELECTRICAL CONNECTOR. CHECKS NORMAL.SDR UALA2011041101734Oxygen Mask · corrodedOXY MASK DEFECTIVE - 1ST OBS. LEFT OBSERVERS MASK APPEARS TO HAVE CORROSION WHERE HOSE CONNECTS TO MASK. REPLACED O2 MASK PER MM, OPS CHECKED GOOD.SDR UALA2011041101732Connector · unsecureEMERGENCY LIGHT ON SEAT 54H AND 59C IS INOP. SECURED SEAT EMERGENCY LIGHT UNDERSEAT CONNECTOR PER MM AND OPS TEST PER MM, TESTS OKAY.SDR UALA2011041101733Oxygen Mask · faultyOXY REGULATOR ABNORMAL OPERATION - CAPT CREW COMMENTS: MASK-REG DOES NOT ALLOW PILOT TO EXHALE. MASK TESTED OKAY. REPLACED O2 MASK PER MM. OPS CHECK GOOD.SDR UALA2011040801703Window · faultyFLIGHT DECK WINDOW 2L UPPER HALVE OF GLASS WILL NOT HEAT. REMOVED INTERIOR TRIM AND WINDOW PER MM. NEEDS PREP AND INSTALL. NEW WINDOW IN AREA. INSTALLED WINDOW UP TO STEP 3.I. (FASTENERS TIGHTENED AND SEALANT APPLIED). ADJ AND TEST PER MM. COMPLETED WINDOSDR UALA2011040801699Battery Pack · faultyEMERGENCY LIGHT IN DOOR 3R DIM NEARLY BURNT OUT. CHECKED AND REPLACED THE LIGHT BATTERY PER SSM. TESTED THE EMERGENCY LIGHT IN DOOR 3R PER TC8203E4567. TESTED GOOD.SDR UALA2011040801698Skin · damagedRIGHT WING, FIXED LEADING EDGE PANEL, AFT EDGE DIRECTLY ABOVE NUMBER THREE ENGINE, HAS 2 RIVETS SHEARED AND PROTRUDING. RIVETS ARE NEXT TO EACH OTHER. INSTALLED 2 EA BLIND RIVETS REF MM. REQUIRES RE-CHECK EVERY AK AND PERMANENT REPAIR AT CK MF6728 OPENED TOSDR UALA2011040801697Skin · damagedLEFT L/E PANEL, ILES 414.50 PANEL INBD AFT CORNER HAS 1 EA RIVET SHEARED. INSTALLED 1 EA ALUMINUM BLIND FASTENER,THIRD FASTENER FORWARD FROM FRONT SPAR L/E, PANEL 6 AT ILES 414.50 IAW AMM. REPLACED THE BLIND RIVET WITH A SOLID RIVET PER AMM.SDR UALA2011040801696Gate · corrodedDOOR 3L LOWER GATE CORRODED AT STOP PIN. REPLACED LOWER GATE ASSEMBLY REF CMM. ACCOMPLISHED ON GFS 0240782.SDR UALA2011040801695Gate · corrodedDOOR 3R LOWER GATE CORRODED AT STOP PIN. REPLACED LWR GATE ASSEMBLY. ACCOMPLISHED ON GFS 0240783.SDR UALA2011040601656Bulb · inoperativeEMERGENCY SILL LIGHTS AT DOORS L1, L2, L3, L5, R2, R3 AND R5 INOPERATIVE. RELAMPED WITH NEW 1317 BULBS IN ALL LOCATIONS. ALL OPS CHECK GOOD.SDR UALA2011040601655Connector · unsecureEMERGENCY LIGHTS ON LEFT SIDE AISLE FROM ROW 54 AFT INOP. RE-SECURED ELECTRICAL CONNECTOR EMERGENCY LIGHT AT AISLE 54 LEFT SIDE PER MM. OPS CHECKS GOOD.SDR UALA2011040601664Unknown · odorMID GALLEY OVEN AREA HAD BURNING ODOR BUT NO SMOKE OR HEAT. CAN'T ISOLATE SO TURNED ALL WARMING OVENS OFF AND ODOR IS GONE PER CREW. CHECKED ALL WARMING OVENS IN MID GALLEY AREA. CHECKED FOR DEBRIS INTERNALLY, NONE FOUND. NO EVIDENCE OF ELECTRICAL ODOR OR BUSDR UALA2011040501652Control Unit · faultedFUEL IMBALANCE BETWEEN NR 2 AND NR 3 TANKS. CONFIRMED UNWANTED FUEL TRANSFER TO NR 3 MAIN TANK. WITH CENTER PUMPS ON TRANSFER RATE 1000LB IN 10 MIN. WILL REQUIRE TANK ENTRY FOR INSP OF NR 3 MAIN TANK PLUMBING. FOUND NR 2 MAIN JETTINSON TRX VLV INOP AND NR 3 SDR UALA2011040501645Lamp · inoperativeEMERGENCY EXIT LIGHT INOP, DOOR 3 RIGHT SLIDE LIGHT. RELAMPED, OP CHECKED OKAY.SDR UALA2011040501648Bulb · inoperativeEMERGENCY LIGHTS AT DOOR 3 RT SIDE INOP. RELAMPED WITH NEW 1317 BULB PER MM. OPS CHECK GOOD.SDR UALA2011040501647Light · inoperativeEMERGENCY UPPER DECK CEILING LIGHTS INOPERATIVE. RELAMPED WITH NEW 1317 BULB PER MM. OPS CHECKS GOOD.