Boeing 747-422
Service difficulty reports · 9,801
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '747422' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011040501646Light · inoperativeEMERGENCY LIGHTS IN FLIGHT DECK INOPERATIVE. RELAMPED WITH NEW 1317 BULB PER MM. OPS CHECK GOOD.SDR UALA2011040401630Sleeve · damagedREPAIR HAS DEPARTED AIRCRAFT FROM NR 4 ENGINE ACOUSTIC LINER ON RT REVERSER SLEEVE BETWEEN 3 AND 4 O'CLOCK. DAMAGED AREA IS 5.0" LONG X 1.25" WIDE X 0.5" DEEP. INSTALLED NEW SLEEVE PER MM, OPS CHECKED GOOD.SDR UALA2011040401601Electronic Unit · malfunctionedLIGHT BALLAST SMELL NEAR ROW 1. ALSO SIDEWALL LIGHT AT 1A CAME ON UNCOMMANDED, WONT GO OFF. T-S FOUND TWO BALLAST (CEILING, SIDEWALL) ARE BAD AND DISCONNECTED PLUGS FROM AFFECTED BALLAST THAT LOCATED CEILING ABOVE 2A SEAT. SMELL IS GONE AND REMAINING LIGHTSDR UALA2011040401617Acoustic Panel · damagedON ARRIVAL INNER ACOUSTIC PANEL DAMAGED BETWEEN 3 AND 4 O'CLOCK POSITION 4"X 2"X .25" DENT-PUNCTURE. AREA REPAIRED PER MM 54-00-01 REPAIR 2 AND AREA TAPED.SDR UALA2011040401593Connector · damagedEEL SEAT 46ABC INOP. REPAIRED CONNECTOR ON EEL LIGHT, OPS NORMAL.SDR UALA2011040401592Light · inoperativeLWR AISLE DOOR 2 LT INOPERATIVE. RELAMPED, OPS NORMAL.SDR UALA2011040401591Light · inoperativeLAV EEL LIGHT DOOR 3 RT INOP. REPLACED EMERGENCY LIGHT PWR STRIP ON FLOOR, OPS CHECK OKAY.SDR UALA2011040401588Light · inoperativeDOOR 4 RIGHT SILL EMERGENCY LIGHT IS INOP. RELAMPED, CHECKS NORMAL.SDR UALA2011040401587Light · inoperativeMID GALLEY SIDEWALL EMERGENCY LIGHTS IS INOP. REPLACED EMERGENCY LIGHT ASSY, CHECKS NORMAL.SDR UALA2011040401612Control Unit · failed'ELEC UTIL BUS R' EICAS ADVISORY MESSAGE DISPLAYED. THE UTILITY BUS 3 (OR 4) OR GALLEY BUS 3 (OR 4) DOES NOT HAVE ELECTRICAL POWER ON IT. AIRPLANE IS NOT IN LOAD SHED CONDITION. CREW COMMENTS: HAPPENED AT GATE. MX RECYCLED SWITCH 3 TIMES. RE-APPEARED AFTSDR UALA2011040401585Fcu · faultyFLAPS PRIMARY MSG DISPLAYED ON RETRACTION DURING TAXI IN. FOUND MAINT MSG 27776, 27777 & 27602. REPLACED FCU-R. OPS CHECK FLAPS SEVERAL TIMES. GRND TEST OKAY.SDR UALA2011040101578Sensor · defectiveREPEAT WINDOW 2R HEAT FAULTS, MANEUVER WIRING AT S761 & S1028 ENSURE VOLTAGE READING DOES NOT FLUCT AND GND REMAINS STEADY. IF 115VAC NOT AT "B" CHK S1028 & S761 FOR OPEN. IF GND NOT AVAIL AT "A" SUSPECT R7338 DEFECTIVE. IF PWR & GND OK OPEN CB C69, DISC WIRSDR UALA2011040101575Window · faultyWINDOW 3R HEATER WIRE CONNECTION B MOUNTING STUD BURNT AND PULLED OUT OF WINDOW. UPPER FWD CORNER. COMPLETED 3 RIGHT WINDOW CHANGE THROUGH END OF TASK. REPLACED 3R WINDOW IAW MM AND TESTED. OPERATES NORMAL.SDR UALA2011033101559Windshield · delaminatedCREW REPORT: L1 WINDSHIELD CLOUDY DELAMS LEFT-TOP. SAMC TEXT: PICTURES ON RVI SITE, WINDOW DELAMINATED WITH EVIDENCE OF MOISTURE INGRESSION ON EDGES. REPLACED L1 WINDSHIELD PER MM AND CHECKS NORMAL.SDR UALA2011033001511Light · unsecureEMERGENCY EXIT LIGHT AFT OF DOOR 1L IS FALLING OFF THE WALL. SECURED LIGHT ASSY, OPS GOOD.SDR UALA2011032901506Starter · faultyNR 3 ENG NO LIGHT-OFF IN IGNITION 2, START NORMAL IN BOTH, FF AND MOTORING NORMAL. CREW COMMENTS: NO N2 DURING START. BAD STARTER, FUEL UPLOAD. REPLACED STARTER AND START VALVE PER MM. OPS NORMAL.SDR UALA2011032901505Brace · damagedNR 2 ENG CORE COWL STRUCTURAL BRACE IS CONTACTING OIL TUBE SUPPORT BRACKET ON BOTH LEFT AND RIGHT SIDES. AREA OF DAMAGE IS BELOW AFT HOLD OPEN ROD MOUNT BRACKET. REMOVED DOUBLER AT COWL HOLD OPEN ROD AT I/B AND O/B COWLS AND DUPLICATED PER BOEING DRAWING. NSDR UALA2011032801485Switch · unsecureSTAIRS GOING TO UPPER DECK, EMERGENCY LIGHT SWITCH CAME OFF AND IS TAPED TO STAIR RAIL. SECURED LIGHT SWITCH AND LIGHT STRIP. OPS OK.SDR UALA2011032801476Battery Pack · inoperativeEMERGENCY EXIT LIGHT INOP. DOOR 4 RIGHT AFT SILL LIGHT. REPLACED BATTERY ABOVE DOOR. OP CHECKED NORMAL.SDR UALA2011032801474Battery Pack · inoperativeEMERGENCY EXIT LIGHT INOP. DOOR 4 RIGHT FWD SILL LIGHT, EMERGENCY EXIT SIGN ABOVE DOOR 4 RIGHT AND EXIT SIGN UNDER VIDEO MONITOR AT DOOR 4 RIGHT. REPLACED BATTERY ABOVE DOOR 4R. OP CHECKED EMERGENCY LIGHTS SILL AND SIGNS ALL NORMAL.SDR UALA2011032801473Light · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE. DOOR 5 RIGHT SLIDE LIGHT. REPLACED LIGHT ASSY. OPS CHECKED NORMAL.SDR UALA2011032801472Lamp · inoperativeEMERGENCY EXIT LIGHT INOP. DOOR 2 GALLEY AREA LOWER LEFT WALL. RELAMPED, OPS CHECKS NORMAL.SDR UALA2011032501430Skin · crackedLT NR 5 MED AFT UPPER CUTOUT SKIN CRACK STA 2280, 3 INCHES DOWN FROM S16L. L=1.5 INCH. MAJOR REPAIR ACCOMPLISHED: SKIN AND BEARSTRAP REPAIRED IAW EN-53-0329.SDR UALA2011032501429Panel · crackedCANTED PRESSURE DECK CLOSE OUT PANEL CRACKED. LENGTH = 1". STA 1241 LBL 76. PANEL REPAIRED IAW 747EN53-0330. REPAIR IS TIME LIMITED FOR 24 MONTHS FROM MAR, 2011 AND PANEL MUST BE REPLACED AT NEXT C-CK, NTE 24 MONTHS. REPAIR ALSO REQ REPETITIVE INSP AT 100SDR UALA2011032501423Bulb · inoperativeUPPER DECK SEAT 13A IS INOP. RELAMPED BULBS.SDR UALA2011032501428Connector · damagedSEAT 43HJK EMERGENCY LIGHT IS INOPERATIVE. REPAIRED CONNECTOR, OPS CHECKED OK.SDR UALA2011032501427Lamp · inoperativeDOOR 1R SILL EMERGENCY LIGHT IS INOP. RELAMPED AFT UPPER SILL LIGHT, OPS CHECKED OK.SDR UALA2011032501426Lamp · inoperativeEMERGENCY LIGHT 3K IS INOPERATIVE. RELAMP SEAT EMERGENCY LIGHT LAMP, OPS CHECKED OK.SDR UALA2011032501425Lamp · inoperativeCEILING EMERGENCY LIGHT NEAR 6A IS INOPERATIVE. RELAMP CEILING LIGHT, OPS CHECKED OK.SDR UALA2011032501424Lamp · inoperativeCEILING EMERGENCY LIGHT NEAR 7AB INOP. RELAMPED CEILING LIGHT, OPS CHECKED OK.SDR UALA2011032501422Bulb · inoperativeCEILING EMERGENCY LIGHT NEAR 57A IS INOP. RELAMPED BULB.SDR UALA2011032501421Bulb · inoperativeCEILING EMERGENCY LIGHT NEAR 49HJK IS INOP. RELAMPED BULB.SDR UALA2011032501420Lamp · inoperativeDOOR 4R SILL EMERGENCY LIGHT IS INOP. REPLACED LAMP.SDR UALA2011032501419Bulb · inoperativeDOOR 3R SILL EMERGENCY LIGHT IS INOP. RELAMPED.SDR UALA2011032501418Lamp · inoperativeCEILING EMERGENCY LIGHT NEAR 4A IS INOP. RELAMPED.SDR UALA2011032501412Skin · damagedAREA OF FUSELAGE SKIN AT STA 154 BETWEEN STRINGERS 33R & 34R HAS BEEN BURNISHED & NEEDS RII MATERIAL LOST INSPECTION. ORIGINAL SKIN THICKNESS IS .062. MAJOR REPAIR ACCOMPLISHED: ACP'D SKIN THICKNESS CHECK. THICKNESS RANGED BETWEEN .0130" AND .050". MADE SDR UALA2011032501411Skin · damagedAPPROX STA 380 ABOVE STR 37R LIGHTNING STRIKE REQUIRES REPAIR. MAJOR REPAIR ACCOMPLISHED: REMOVED FASTENERS AND DAMAGED SKIN IN REPAIR AREA. MFG'D, DRILLED, COUNTERSUNK AND PRIMED DOUBLER. MFG'D FILLER AND PRIMED FUSELAGE. INSTALLED REPAIR DOUBLER, SEALED SDR UALA2011032301391Window · crackedNR 1L FLT DECK WINDOW SHOWS EVIDENCE OF CRACKS AND MOISTURE INGRESS ALONG INBD UPPER EDGE. ACCOMPLISHED EXAMINATION OF WINDOW 1L ALONG INBD & OTBD UPPER & LWR EDGES WITH OPTICAL MICROMETER & FOUND CRACKING TO BE IN THE OUTER URETHANE INTERLAYER. NO MOISTURE SDR UALA2011032201384Light · inoperativeEMERGENCY SILL LIGHT DOOR 4 LT AFT INOP. LIGHT FOUND DEFECTIVE. RELAMPED, OPS ARE GOOD.SDR UALA2011032201383Battery · dischargedDOOR 5 LT EXIT SIGN ABOVE DOOR INOP. BATTERY IS INOPERATIVE. REPLACED BATTERY. OPS ARE GOOD.SDR UALA2011032201382Light · inoperativeEMERGENCY LIGHT ABOVE STAIRS AFT CREW REST INOP. LAMP IS INOPERATIVE. RELAMPED, OPS OKAY.SDR UALA2011032201381Connector · unsecureEMERGENCY LIGHT LOCATED AT FWD GALLEY DOOR 1 LT EXIT SIGN AND WALL INOP. CLEANED AND RE-SECURED EEL CONNECTOR. OP CHECK NORMAL.SDR UALA2011032201380Light · inoperativeEMERGENCY CEILING LIGHT AFT ABOVE ROW 17 INOP. LIGHT FOUND FAULTY. RELAMPED, OP CHECK NORMAL.SDR UALA2011032201379Light · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 17 INOP. LIGHT NOT WORKING. RELAMPED, OP CHECK NORMAL.SDR UALA2011032201378Light · inoperativeEMERGENCY LIGHT ROW 16 LT INOP. LAMP NOT OPERABLE. RELAMPED, OP CHECK NORMAL.SDR UALA2011032201377Light · inoperativeEMERGENCY LIGHT ROW 15 LT INOP. LIGHT NOT WORKING. RELAMPED, OP CHECK NORMAL.SDR UALA2011032201376Light · inoperativeEMERGENCY CEILING LIGHT ABOVE ROW 15 INOP. LAMP INOP. RELAMPED, OP CHECK NORMAL.SDR UALA2011032201375Light · inoperativeEMERGENCY LIGHT ALONG GALLEY DOOR 2R INOP. LIGHT FOUND DEFECTIVE. RELAMPED, OP CHECK NORMAL.SDR UALA2011032201373Ballast · odorSTRONG ACRID ODOR NEAR 3K ON TAXIOUT. RETURN TO GATE. FLORESENT LIGHT ABOVE 3K STOW BIN INOP. DISCONNECTED BALLAST. REPLACED BALLAST.SDR UALA2011032101370Connector · unsecureEEL INOP SEAT 38 LT. SECURED UNDERSEAT CONNECTOR. OP CHECKED NORMAL.
Back to Boeing 747-422